HomeMy WebLinkAboutPRODUCT EVALUATION REPORTBMFFAV ALW
Product Evaluation Report
Date:
March 9, 2015
Report #:
2088
Report Revision No.:
1
SCANNED
BY
Project #:
414-0315
St. Lucie County
Product Mfg.:
Jeld-Wen Inc.
355 Center Court
Venice, Florida 34286
Product Description:
Premium Atlantic Aluminum Non -Impact Steel Reinforced Sliding Patio Door
Product Category:
Exterior Doors
Product Sub -Category:
Sliding Exterior Door Assemblies
Compliance Method:
Product Approval Rule 61G20-3.005 (1)(a)
— Certification Mark or Listing
Prepared By:
Robert J. Amoruso, P.E.
Florida P.E. No. 49752
PTC Product Design Group, LLC, PO Box 520775, Longwood, FL 32752-0775
Florida C of A No. 25935
CERTIFICATE OF INDEPENDENCE
PTC Product Design Group, LLC and RobertJ. Amoruso,
P.E. do not have, nor will acquire, any financial interest
in the company manufacturing or distributing
product(s) covered by this Product Evaluation Report.
PTC Product Design Group, LLC and Robert J. Amoruso,
P.E. do not have, nor will acquire any financial interest
in any other entity involved in the approval process or
testing of the product(s) covered by this Product
Evaluation Report.
PTC Product Design Group, LLC
P.O. Box 520775 — Longwood, Florida 37252
Phone:321-690-1788 Fax:321-690-1789
FBPE Certification of Authorization No. 25935
Digitally signed by Robert
J. Amoruso, P.E.
DN: cn=Robert J.
Amoruso, P.E., o=PTC
Product Design Group,
LLC, ou=FL P.E. No. 49752,
FBPE Cent. of Auth. No.
25935, email=robert@ptc-
corp.com, c=US
Date: 2015.03.09 09:31:02
-04'00'
Evaluated by:
RobertJ. Amoruso, P.E.
FL No. 49752
Project No. 414-0315 Robert J. Amoruso, P.E.
Product Evaluation Report FL No 49752
No. 2088, Rev. 1 Page 1 of 4
SCOPE
Evaluate Jeld-Wen Inc. Premium Atlantic Aluminum Non -Impact Steel Reinforced Sliding Patio Door for
conformance to the current edition of the Florida Building Code — Building and Residential Volumes including the
High Velocity Hurricane Zone (HVHZ).
The engineering analysis (Reference 3.a) determines the anchorage of the product to the supporting substrate
and the product evaluation report (this document) summarizes Florida Building Code compliance verification
and appropriate Limitations and Conditions of Use.
DESCRIPTION OF PRODUCT- INSTALLATION REQUIREMENTS
See Reference 1 for a description of the product, its installation and other pertinent data related to its approved
use.
CODE CONFORMANCE
This product is designed to comply with the current edition of the Florida Building Code (FBC) requirements
including the High Velocity Hurricane Zone (HVHZ).
LIMITATIONS AND CONDITIONS OF USE
This product evaluation contains or makes reference to specifications, technical details and installation details
and/or methods that pertain to the proper use and/or installation of the product specified herein. Specific
limitations and conditions of its use including but not limited to the following are contained in Reference 1 and
are the subject of Product Approval in accordance with the State of Florida Product Approval Rule 61G20-3.005.
• Design Pressure Rating (psf) • Installation restrictions.
• Installation substrate requirements. • Product description.
• Installation anchor requirements. • Product components.
QUALITY ASSURANCE
This product is manufactured under a quality assurance program audited by an approved Certification and
Quality Assurance Entity National Accreditation & Management Institute (NAMI) as required in Rule 61G20-
3.005. See FBC Organization No. CER1773 and QUA1789 for approval under Rule 61G20-3.005.
PTC Product Design Group, LLC Project No. 414-0315 Robert 1. Amoruso, P.E.
P.O. Box 520775 — Longwood, Florida 37252 Product Evaluation Report FL No 49752
Phone: 321-690-1788 Fax: 321-690-1789 No. 2088, Rev.1 Page 2 of 4
FBPE Certification of Authorization No. 25935
APPLICATIONS/INSTALLATIONS OUTSIDE THE LIMITATIONS AND
CONDITIONS OF USE
Rule 61G20-3.005 states "Rational engineering analysis cannot be used in lieu of a standard test required by the
Code for approval of products within the scope of the standard, except that project specific approval by the local
authorities having jurisdiction in accordance with alternate methods and materials authorized in the Code."
Any modification to this product as evaluated in this report and approved by the Florida Building Commission is
outside the scope of this evaluation and will be the responsibility of others. As allowed in Rule 61G20-3.005,a
project specific approval by the local authorities having jurisdiction may be used given an appropriate rational
analysis is conducted and deemed acceptable to the local authorities having jurisdiction.
PERFORMANCE AND TESTING STANDARDS
Reference 2 conducted testing to the following standard.
1. TAS202-94, Criteria for Testing Impact & Non -Impact Resistant Building Envelope Components Using
Uniform Static Air Pressure.
REFERENCES & SUPPORTING DOCUMENTS
1. Drawings:
a. JELD0096 Rev. A, dated March 9, 2015, signed and sealed by Roberti. Amoruso, Jeld-Wen Inc.
Premium Atlantic Aluminum Non -Impact Steel Reinforced Sliding Patio Door— Installation
Anchorage Details.
2. Test Reports by National Certified Testing Laboratories:
a. NCTL-210-3382-2, dated March 14, 2007 with Addendum, dated August 28, 2007
b. NCTL-210-3360-2, dated December 8, 2006 with Addendum, dated August 28, 2007
c. NCTL-210-3382-3, dated March 14, 2007 (TAS 202 test of impact product verifies 3-track system).
SGD verification as follows:
i. NCTL 210-3382-2 covered a 2-track system with five (5) 48" wide panel 237.25" x 96" XXXXX
door with all utilized XXXXX stiles conditions, therefore door widths greater than the tested
size are allowed. Pocket door configurations also covered by this testing. Multiple door
configurations shown on Reference l.a covered in testing.
ii. NCTL-210-3360-2 covered a 2-track system with six (6) 48" wide panel 283.5" x 96" OXXXXX
door with all utilized OXXXXX stiles conditions, therefore door widths greater than the
tested size are allowed. Multiple door configurations shown on Reference l.a covered in
testing.
iii. NCTL 210-3382-3 covered a 3-track system with a three (3) 48" wide panel 142.75" x 96"
XXX door. This test verifies 3-track systems. This impact glazed door is used to verify 3-track
system for non -impact applications. Multiple door configurations shown on Reference 1.8
covered in testing.
PTC Product Design Group, LLC Project No. 414-0325 Robert J. Amoruso, P.E.
P.O. Box 520775 — Longwood, Florida 37252 Product Evaluation Report FL No 49752
Phone: 321-690-1788 Fax: 321-690-1789 No. 2088, Rev. 1 Page 3 of 4
FBPE Certification of Authorization No. 25935
ArWFN
3. Reports:
a. PTC Report No. 1911, Rev. 1, Anchorage Engineering, for Jeld-Wen Inc. Premium Atlantic Aluminum
Reinforced Non -Impact Sliding Patio Door, dated May 7, 2012, signed and sealed by Robert J.
Amoruso.
b. PTC Report No. 2088-EER, Rev. 1, Equivalency of Standards Evaluation for Jeld-Wen Inc. Premium
Atlantic Aluminum Reinforced Non -Impact Sliding Patio Door, dated March 9, 2015, signed and
sealed by Robert J. Amoruso.
4. Current Edition of the Florida Building Code
PTC Product Design Group, LLC Project No. 414.0315 Robert J. Amoruso, P.E.
P.O. Box 520775 — Longwood, Florida 37252 Product Evaluation Report FL No 49752
Phone:321-690-1789 Fax:321-690-1789 No.2088,Rev.1 Page 4 of
FBPE Certification of Authorization No. 25935