HomeMy WebLinkAboutWIND LOAD DESIGN PRESSURE CALCULATIONSWsENGINEERIr `G
EXPRESS
Order (Ref) #: 44206 (043326-7269097222)
Contractor: J&G CARPENTRY, INC.
Project Details: JENSEN CONDO DOOR REPLACEMENT
7030 S.W. 16TH COURT PEMBROKE
PINES, FL
9490 S. OCEAN DRIVE, UNIT 811
JENSEN BEACH, ST. LUCIE COUNTY, FL
Subject: Wind Load Design Pressure Calculations (Components & Cladding)
Site Information
Building Classification:
enclosed
Wind Speed (V It):
170 mph
Exposure Category:
d
Roof Type:
monoslope
Roof Slope (0):
1.2 deg
Mean Roof Height (h):
90.0 ft
Min. Building Dimension (L):
54.0 ft
Parapet>_ 3 feet?
No
0
Z �
Z }
n'
6
General Calculation
Directionality Factor (Kd):
0.85
Gust -Effect Factor (G):
0.85
Internal Pressure
Coefficient (GC pi):
±0.18
Topographical Factor (Kt):
1.0
Velocity Pressure Exposure
Coefficient K
1.41
Velocity Pressure (qh):
88.48 psf
End Zone (a):
5.4 ft
ASD Method:
P = 0.6w
NOTES: Design is in accordance with ASCE 7-10 (ASD method) and the Florida Building Code Sixth Edition (2017). Results [ �'
Vllr Qnllyyvith.
are not valid fog use unless approved via original signature and raised engineer seal of a PE from Engineering Express. "v
Results are based on contractor -supplied data and shall be field verified by others prior to use. Selection & installatioq'�f
9ised Engineer
\v ,.....U���
products shall be approved using these dimensions and pressures as verified by others. \ �O(�'
• �LOENSF •' /,0'�%
Note: For openings to be properly rated in Zone 4, no part of the opening shall be within 5.4 feet of any buildinLtorne : •
Nd M 1. O 018
This engineer has not field visited this locatlon and if this cannot be clearly identified by others, the opening sha-0 b*re:-
GOr9n i attista> R.E.evaluated
prior to installation of any fenestration. All other information provided above Including mean roof heigpb
'•,
-
232$
bullding minimum dimensions, opening sizes, & other supporting data was provided by others. For definitions of tk�
t `
above terms, visit EngineeringExpress.com/Wiki "
i
STACEKbIAuth-'9885F
'
G
;S/ONAL EN `
�f rlllt,l „
160 SW 12TH AVENUE, SUITE 106, DEERFIELD BEACH, FLORIDA 33442
44206(043326-7269097222) PHONE: (954) 354-0660 —FAX: (954) 354-0443
AutoPrint ENGINEERINGEXPRESS.COM PAGE 10F 1