HomeMy WebLinkAboutMISC LETTERSCANNED
August 7, 2018 BY
St- Lucie County
Saint Lucie County
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982
, "-W
a
E N G IN E E R ING G R 0 UP
Subject: Special Inspection Letter of Intent
AT&T Site: JENBEACH [FA# 10016793]
Site Address: 10680 South Ocean Drive, Jensen Beach, FIL 34957
APX Project: 18-0163.16
Dear Sir or Madam:
APX Engineering Group, LLC (APX) understands that Saint Lucie County requires that, as special inspector
for the subject construction project, APX supplies specifications setting forth the procedures to be taken for
the required inspections. The purpose of these inspections Will be to determine if the installation of the
antenna equipment is in substantial accordance with the approved construction drawings prepared by APX
dated August 7, 2018. Such special inspections will be performed in accordance With Section 110.10.1.1
of the Florida Building Code and will include, but not be limited to, the following:
1. Inspect mounting of proposed remote radio units (RRUs) and proposed peripheral equipment to
the existing mounts.
Copies of the inspections shall be sent to the Building Department on a weekly basis, and the final letter of
completion will be provided at the completion of the final inspection.
This letter has been prepared for the purpose of fulfilling the requirements of Saint Lucie Countywith respect
to the specific installation described. It is intended for the exclusive use of Saint Lucie County and AT&T.
The information, assumptions and recommendations contained in this letter should not be used by others
for any purpose without express written authorization from APX
Should you have any questions orwish to discuss any aspect of this letter, please do not hesitate to contact
the undersigned.
Sincerely,
APX Engineering Group, LLC
Michael A. Phillips, P.E.
Chief Engineer
Florida License #68312
at&t
March 20, 2018
Dennis Demarco
MasTec Network Solutions, LLC
6100 Broken Sound Parkway, Suite 6
Boca Raton, FL 33487
Subject: Structural Analysis - Antenna Mount
Carrier Designation: AT&T: JENBEACH [FA# 10016793]
APX Project: 18-0163.16
a
E N G IN E E R ING G R 0 UP
Site Information: 10680 South Ocean Drive
Jensen Beach, Saint Lucie County, FL 34957
Latitude 27.2715000 N, Longitude 80.2043060 W
Existing Tripod Antenna Mount
Dear Mr. Demarco:
APX Engineering Group, LLC (APX) is pleased to submit this Structural Analysis to determine whether the
subject existing antenna mount is able to support certain proposed loads.
It is our understanding that AT&T, who retained MasTec Network Solutions (MNS), desires to install new
telecommunication equipment on the subject mount. This analysis was based on the supporting information
listed in Table 2. Our services were performed in accordance with the terms and conditions of the master
service agreement between APX and MNS. This report summarizes the results of our findings.
The purpose of this analysis is to determine the suitability of the aforementioned structure to support the
loading indicated in the attached calculations. This analysis has been performed in accordance with the
Florida Building Code based upon an ultimate 3-second gust wind speed of 164 mph using RISA-3D
structural software. Based on our analysis, subject to the assumptions and recommendations noted, it is
our opinion that the subject structure will support the proposed loading.
=Exist-ing Members: Pass at 76.4%, Existing Connections: Pass at 72.3%
This report has been prepared for the purpose of providing a structural evaluation of the subject structure
for the loading conditions indicated. It is intended for the exclusive use of AT&T and MNS. The information,
assumptions, and recommendations contained in this report should not be used by others for any purpose
without express written authorization from APX We appreciate the opportunity to provide our professional
services to you and look forward to continuing our relationship. If we can be of any further assistance,
please do not hesitate to contact us. ttL1151111121i I?
Sincerely,
APX Engineering Group, LLC
Eliezer Diaz, E.I. Michael A. Phillips, P.E.
Project Engineer Chief Engineer
Florida License #68312
N
Fi I S�
,4�0/VAL
"IeII111111"I",
AT&T: JENBEACH JFA# 100167931
Structural Analysis Report
Table 1: Anaivsis Criteria
Criterion
Building Code
Description
Florida Building Code, 6th Edition (2017)
Standard - Loads
ASCE 7-10 Minimum Design Loads for Building and Other Structures
(FBC 1609.1.1)
Standard - Steel
AISC LRFD 14th Edition
Risk Category
11
Ultimate Wind Speed
164 mph, 3-Second Gust (FBC Figure 1609.3(l))
Nominal Wind Speed
127 mph, 3-Second Gust (FBC 1609.3.1)
Exposure Category
D
Live Load
N/A
Dead Load
Self -Weight
Table 2: SuoDortina Information
March 5, 2018 1 Radio Frequency Data Sheet (RFDS) AT&T
September 20, 2017 1 Antenna Mount Analysis APX
September 14, 2017 Site Visit/investigation APX
Various Miscellaneous Information AT&T/MNS
Analysis Assumptions and Limitations
1. Information in the supporting documentation that could not be verified by APX personnel is
assumed to be correct.
2. All structural components are assumed to be in adequate condition to carry their full design
capacity.
3. The configuration of equipment/appurtenances is assumed to be as specified in this report.
4. Emergency/essential communication equipment will not be supported by this assembly.
If any of the above assumptions are not valid or have been made in error, these calculations may be
affected, and APX should be allowed to review any new information to determine its effect on the structural
integrity of the subject structure.
Recommendations
1. Check all bolts for proper tightening in accordance with AISC "Snug -Tight" method prior to
installation of proposed equipment.
2. Replace any rusted/corroded hardware with new galvanized hardware.
APX Engineering Group, LLG
A
Inspection Date: March 14, 2019 a
Saint Lucie County
Planning & Development Services E H G IN E E R ING G R 0 UP
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982
Subject: SpecjW,�WMeSt.Lon Report I of 1 (Final) 15C]
Permit: SLC tW8
AT&T Site: JENBEACH 1FA# 10016793]
Site Address: 10680 South Ocean Drive, Jensen Beach, FL 34957
APX Project: 18-0163.16
Dear Building Official:
APX Engineering Group, LLC (APX) performed observations of the AT&T telecommunication facility
located at the above -referenced site. The purpose of these observations was to inspect the following in
accordance with the Florida Building Code, 61h Edition (2017) and the National Electric Code (NEC), 2014
Edition:
1. Installation of six proposed Remote Radio Units (RRUs).
2. Installation of proposed power cables.
3. Installation of proposed fiber cables.
4. Installation of proposed grounding system.
The -installation -of the above -mentioned items was visually inspected and compared with the approved
construction-Arawings by APX Engineering Group, LLC dated August 7, 2018. Based on these
observations -and to -the best of my knowledge and belief, the above -described construction of all
structural load -bearing components complies with the permitted documents.
Should you have any questions or wish to discuss any aspect of this letter, please do not hesitate to
contact the undersigned.
Sincerely,
APX Engineering Group, LLC
Michael A. Phillips, P.E.
Chief Engineer
Florida License #68312
Inspection Date: March 14, 2019
Saint Lucie County
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982
a
E N G IN E E R ING G R 0 UP
Subject: Special Inspection Report I of I (Final) [5C]
Permit: SLC 1808-0659
AT&T Site: JENBEACH [FA# 100167931
Site Address: 10680 South Ocean Drive, Jensen Beach, FIL 34957
APX Project: 18-0163.16
Dear Building Official:
APX Engineering Group, LLC (APX) performed observations of the AT&T telecommunication facility
located at the above -referenced site. The purpose of these observations was to inspect the following in
accordance with the Florida Building Code, 6th Edition (2017) and the National Electric Code (NEC), 2014
Edition:
1. Installation of six proposed Remote Radio Units (RRUs).
2. Installation of proposed power cables.
3. Installation of proposed fiber cables.
4. Installation of proposed grounding system.
The installation of the above -mentioned items was visually inspected and compared with the approved
construction drawings by APX Engineering Group, LLC dated August 7, 2018. Based on these
observations and to the best -of my knowledge and belief, the above -described construction of all
structural load -bearing components complies with the permitted documents.
Should you have any questions or wish to discuss any aspect of this letter, please do not hesitate to
contact the undersigned.
Sincerely,
APX Engineering Group, LLC
Michael A. Phillips, P.E.
Chief Engineer
Florida License #68312
Lydia Galbraith I I I
From: RomyWanliss �Romey.Wanliss@mastec.ccrm�
Sent: Monday, August 27, 2018 9.42 AM
To: Lydia Galbraith
Subject:- RE: Report-FL_ReVieW_Comment�_Noncompliantjrf.pdf, PERMIT 1808-0659
Attachments: SKMBT�C364eI8O827084g0,pcff,, SKMBT_C364e18OS2708120.pcff:, 09109188 bond.pdf
Lydia
Thank you for your prompt response. My apologies for not paying enough attention to the permit application. My permit runner printed a copy of the
application from my previous project. AT&T is only adding 3 RRU next to the antennas. All other work is confined to the equipment room.
Please let me know if I need to drop off a new application.
Roney E Wariliss
Site Acquisition Project Alartager SF`L
6100 Broken Sound Pkwy Suite 61 Boca hand, FIL 33487
Cell — 954 3014949
NGTICE� Tire informorairm contained m this email ond my document, ansifteri Income is intended only for the mail resiphort(s). If,out ma not the intended recipient, Par the employee or agent
.spoinsibl, for ckliveri., this triesso, in cordidance to the intended recipicist(s), you som hereby dofified that you have inceived this in moor, end an, resims, dissemination, distribution or
copying of this marrommurd or its morclImends, is all prohibited. Ifyrm I. inereived this arammill andta, in drom, Please ineddly rom immediately by rd,ly �drvril add their delcom this
amom,, irmimlio, any itimhroonts
From: Lydia Galbraith (malito:galbralthl@st[uCteco.orgI
Sent: M onday, August 27, 2018 8:43 AM
To: Foray Wanliss <RoreyWanfiss@nhastec.cr
Cc: 'DT2108@ATT.COM'�DT2108 @ATr.COM>
Subject: [Externail Report FL Review —Comments Noncom plia nt_jrf.pdf, PERMIT 1808-0659
Attention: This email was sent from someone outside of MasTec. Please use caution when opening attachments or clicking on links In entails which are
unexpected or arrive from unknown senders.
Roney,
Attached please find the Zoning review comments and list of missing documents. If you have any questions, please let me know.
Thankyou,
Lydia Gaffiraith.
Zoning Specialist
Building and Code Regulation
(772) 462-1555
galbraithfidststlucieco.or