Table
Deck
Application
Type
Description
Page _
1A
Wood
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
5
1B-1
Wood
New or Reroof (Tear -Off)
A-2
M ech. Attached Ancho r Sheet, Bonded I nsulatio n, Bonded Roof Cover
5-9
113-2
Wood
New, Rercof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
10-11
1C
Wood
New, Rercof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
11 —
1D
Wood
New, Renoof (Tear -OM or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
12-13
1E
Wood
New, Reroof(Tear-Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
14-15
IF-1
Wood
New or Reroof (Tear -Off)
E
Non -insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover
16-18
1F-2
Wood
New, Reroof (Tear -Off) or Recover
E
Non-In5ulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover
19-21
W�gea,4_
l(N`o?71—nsuTat—ed� BMonded:R-0ofCuvr
pteo'o rStructuml concrete
_ fflT
N Mew-, —R eir —oo f(fe a —ro fQ a r R e cc v e r
B
�MMEMWR—Acrecftiase —JnsulaFii3r�sancled Top Insulation, Bonded Roof Cover
2 2§27P
2B
Steel or Structural concrete
N ew, Reroof (Tear -Off) o r Recover
C
Mech. Attached Insulation, Bonded Roof Cover
25-28
2C
Steel or Stru ctu ra I cc ncrete
N ew, Reroof (Tear-Dff) a r Recover
D
P re lim. Attach ed I nsulatio n, Mech. Atta ch 2d Base Sheet, Bonded Ro of Cove r
29-31
3A
Structural Concrete
New or Rercof (Tear -Off)
A-1
Bonded Insulation, Bonded RoofCover
32-40
3B
Structural concrete
New or Rercof (Tear -Off)
F
Non -insulated, Bonded RoofCover
40
4A
LWIC
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded RDDfCover
41-42
4B
LWIC
New or Reroof (Tear -Off)
A-2
Mech, Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
43
4C
LWIC
New or Rer0DfF (Tear -Off)
E
Non -insulated, Mech. Attached Base Sheet, Bonded RoofCover
44-46
5A
CWF
New or Rercof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
47
5B
CWF
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded RoofCover
48
5C
CWF
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
49
51)
CWF
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
49
5E
CWF
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded RoofCover
49
6A
Gypsum
Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
50-52_
6B
Gypsum
Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
52
6C
Gypsum
Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
53
6D
Gypsum
Remof (Tear -Off) or Recover
E
Non -insulated, Mech. Attached Base Sheet, Bonded Roof Cover
53
7A
Various
Recover
A-1
Bonded Insulation, Bonded RoofCover
54-58
7B
Various
Recover
F
Non -insulated, Bonded Base Sheet, Bonded Roof Cover
58
The following notes apply to the systems outlined herein:
1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be In accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement:
> Wood: Minimum 0.75-inch penetration.
> Steel: Minimum 0.75-inch penetration and engagethetop flute ofthesteel deck.
> Structural concrete: Minimum 1-Inch embedment into pilot hole in accordancewith fastener manufacturer's published installation instructions.
3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum -based roof board or mineral -wool roof board that meets the QA
requirements ofF.A.C. Rule 61G20-3 and is documented as meeting FBC1505.1 and,forfoam plastic, FBC Chapter 26, when installed withthe roofcover.
Exteriorlinesearch and Design, U.C. d/b/a Trinity I ERD Evaluation Report P9290.02.08-R20 for FL1654-RZ2
Certificate ofAuthorization #9503 EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20:09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 394-1730 Appendix 1, Page I of58
r_\."�
VT�INITYJ ERD
4. Minimum 200 psi, minimum 2-Inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base
sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. RDof decks and
structural members shall be in accordance with FEC requirements to the satisfaction of the Authority Havfng Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC
Approval documentation.
5. Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016).
6. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published instructions.
> Hot asphalt [HA):
Full coverage at 25-30 lbs/square.
> Dow INSTA STIK Quilk Set Insulation Adhesive (D-IS):
Continuous 0.75 to 1-Inch wide ribbons, 12-Inch o.c.
> Millennium One Step Foarnable Adhesive (M-OSFA):
Continuous 0.25 to 0.5-Inch wide ribbons, 12-Inch o.c.
> Millennium PG-1 Pump Grade Adhesive (M-PGI):
Continuous 0.25 to 0.5-inch wide ribbons, 12-Inch o.c.
> OMG OlyBond 500 (OB500):
Continuous 0.75 to 1-Inch wide ribbons, 12-inch o.c. (PaceCart orSpotShot). Note: OlyBond Green maybe used where OlyBond5OOis referenced.
> OlyBond Classic (OB Classic):
Fulf coverage at 1 gal/square.
> ICP Adhesive & Sealants CR-20:
Continuous 2.5-3.5-inch wide ribbons, 12-inch o.c.
> Note; When multiple loyers(s) of insulation andlor coverboard
are installed in ribbon -applied adhesive, boardjoints shall be staggered.
> Note: The maximum edge distancefrom the adhesive
ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing.
7. Unless otherwise noted, all insulations are flat -stock or taper board of the minimum thickness noted. Tapered polylsocyanurate at the following thickness limitations maybe substituted with the following Maximum
Design Pressure (MDP) limitations. In no case shall these values be used to 'Increa5e' the MDP listings in the tables; rather if MDP listing below meets orexceeds that listed for a particular system in the tables, then
the thinner board listed below maybe used as a drop-Infor the equivalent thicker material listed in the table:
> Millennium One Step Foamable Adhesive (M-DSFA): MDP -157.5 psf
(Min. 0.5-Inch thick)
> Millennium PG-1 Pump Grade Adhesive (M-PG1): MDP -157.5 psf
(Min. 0.5-Inch thick)
> DMG DlyBond 500 (OB500): MDP -45.0 psf
(Min. O.S-Inch thick Multi -Max FA-3)
> OMG OlyBond SOD (OB500): MDP -187.5 psf
(Min. 0.5-Inch thick ISO 95+ GQ
> OMG OlyBond SOD (CBSCO): MDP -315.0 psf
(Min. 0.5-inch thick ENRGY 3)
> DMG OlyBond 50D (OBSOD): MDP -487.5 psf
(Min. 0.5-inch thickACFoam 11)
> ICP Adhesives & Sealants CR-20: MOP -117.5 psf
(Min. 1.0-inch thick)
8. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft.
9. For mechanically attached Components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone I design pressure determined in accordance with FBC
Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss
Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk- carry the limitations set forth in Section 2.2.10.1 of FM Loss
Prevention Data Sheet 1-29 (January 2016) forZone 2/3 enhancements.
10. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted.
11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the
minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105.
12. For existing substrates in a bonded recover or re -roof installation, the existing roaf5urfaCe or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing
roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with
ANSI/SPRI IA-1, A5TM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124.
13. For Recover Applications using System Type D, the insulation is optional; however, the existing roof system shall be suitable for a recover application.
14. Lightweight Insulating Concrete (LWC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC Is referenced, refer to current LWC
Product Approve[ for specific deck construction and limitations. For systems where specific LWC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum tDip-coat thickness is 2-inches.
For LWC ever structural concrete, reference is made to FBC Section 1917.4.1, Point 1.
Exterior Research and Design, Ur d/b/a Trinity I ERD Evaluation Report P9290.02.08-R20 for FL16S4-R22
Certificate of Authorization #9503 6� EDITION (2017) FBC N ON-HVHZ EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen,PE-59166 Poiyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 2 of 58
JIM
'\�TRINITYJERD
15. Unless otherwise noted, refer to the following references for bonded base, ply or caps heet app I! cations.
TABLE 1: PoLYGLAss ROOF COVERS
Reference
Layer
Material
Application
SP-AA
Base Ply
One or more plies Polyglass G2 Base, FEC Approved ASTM D4601, Type 11
Hot Asphalt at 20-40
(Base and Ply sheets, Asphalt-
Ply
One or more plies Polyglass Ply IV, Polyglass PlyVI, FBC Approved ASTM D2178, Type IV orVl
Applied)
Note:
Asphalt -applied sheets or insulation shall not be applied to poly -film surfaced membranes.
lbs/square
Base Ply
One ply Elastobase (sand/sand), Elastoflex V, Elastoflex S6, Elastoflex S6 Type 11, Polyglass HT Base 650 -
PG350 at 1.5-2.0
5BS-CA1
Cap Ply
Elastoflex VG, ElaStDflex VG FR, Elastoflex S6, Elastoflex S6 Type 11, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, ElaStDShleld
gal/square
TS-G FR, Polyfresko G SBS (sand -backed), Polyrfresko G SBS FR (sand -backed)
Base Ply
One ply Elastobase (sand/sand), Elastoflex V, Elastoflex S6, Elastoflex SIS Type 11
Polyplus 35 at 1.5-2.0
SBS-CA2
Cap Ply
Elastoflex VG, Elastoflex VG FR, Elastoflex 56, Elastoflex 56 Type 11, Elastoflex S6 G, Elastoflex S6 G FIR, Elastoshield TS-G, Elastoshield
gal/square
TS-G FR, Polyfresko G SBS (sand -backed), Polyfiresko G SBS FR (sand -backed)
Base Ply or Ply
One or more plies Elastobase (sand/sand or poly/sand), Elastobase P (sand/sand or poly/sand), Elastoflex V, Elastoflex S6, Elastoflex
SBS-AA
S6 Type 11, Polyglass HT Base 650
Hot Asphalt at 20-40
(SBS, Aspha It-App lied)
Cap Ply
astoflexVG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6 Type 11, ElastoflexS6 G, ElastoflexS6 G FR, Elastoshield Ti
Elastoflex V, E _G'
lbs/square
Elastoshleld TS-G FR, Polyfiresko G SBS (sand -backed), Polyfiresko G SBS FR (sand -backed)
Note:
Asphalt -applied sheets or insulation shall not be applied to poly -film surfaced membranes.
Base Ply or Ply
One or more plies Elastobase (sand/poly), Elastobase (poly/poly), Elastoflex V, Elastoflex S6, Elastoflex S6 Type 11, Pohyglass HT Base
SBS-TA
650
Torch -Applied
(SBS, Torch -Applied)
Cap Ply
Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex S6, ElastoflexS6 Type 11, Elastoflex SG G, Elastoflex S6 G FR, ElaStDshield TS-G,
Elastoshleld TS_ " lol Y'reko 13 SBI ty-film backed), Polyfiresko G SBS FR (poly -film backed)
BTs IV
One or more pheE� Z A%' Elastoflex SA V FR Base, Elastoflex SA V Plus, Elastoflex SA V Pius FR
'ntip"Fir
00istofie" �VA-DEla—st6ft-R's-XP'FR,'P6l�reffect
Note:
Unless othemise noted, permissible membrane substratesfor SBS-SA are limited to the SBS-SA Base Ply options herein,
Self -Adhering
Elastobase (p olylsond) or Elastobase (p olylpoly).
APP-CA1
Cap Ply
Polyflex G F
PG350 at 1.5-2.0
ga square
APP-TA
Base Ply or Ply
One or more plies Polyglass APP Base, Polyflex, Polybond
(APP, Torch -Applied)
Cap Ply
Polyflex, Polyflex G, Polyflex G FR, Polybond, Polybond G, Polyfiresko G, Polyfiresko G FR
Torch-Apphed
Cap Ply
Polyflex SA P, Polyflex SA P FR, Polyfresko G SA, Polylkool
APP-SA
(APP, Self -Adhering)
Note:
Unless othe�ise noted, permissible membrane substratesforAPP-SA are limited to the 5BS-5A Base Ply options herein,
Self -Adhering
Elastabase (polylsiand) or Elastaluarse (polylpally).
16. Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance.
associated with coating usage.
PG200 Non Fibered Roof Coating;
PG300 Fibered Roof Coating;
PG600 Non-Fibered Alurnlnum Roof Coating;
PG650 Fibered Aluminum Roof C.adra;
PG700 High Quality Elastcmeric Roof Coating or KM Acryl 25;
PG700QS (Qulck Set) High Quality Elastomeric Roof Coating or KM Acryl 25-QS (forgranuie-surfaced APP or SBS only);
PG800 Asphalt Emulsion Roof Coating;
Polyplus 60 Premium Non-Fiberad Aluminum Roof Coating;
Polypius 65 Premium Fibered Aluminum Roof Coating;
Pclybrite 70 Premium Grade Elastomeric Roof Coating or KM Acyl 15;
Polybrite 70QS (Quick Set) Premium Grade Elastomeric Roof Coating or KM Acryl 15-QS (for granule -surfaced APP or SBS only);
Polybrite 90 High Solids Silicone Roof Coating or Polybrite 95 Silicone Beef Coating.
Exterior Research and Design, I.I.C. d/b/3 Trinitill ERD
Certificate of Authorization #9503 IS'n EDITION (2D17j FBC NON-HVHZ EVALUATION
Preparedby: RobenNieminen,PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230
Refer to current Roofing Materials Directory for fire ratings
Evaluation Report P9290.02.08-R20 for FLIS54-R22
Revision 20; 09/12/2017
Appendix 1, Page 3 of 58
1,,NT INITY I ERD
TABLEIF-2: WOOD DECKS— NEW CONSTRUCTION; REk0OF (TEAR -OFF) OR1RECOVBR
SYSTENITYPEP NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS& PLATES), BONDED ROOF COVER
System
BaseSheet
���
Roof Do ye�� �otel%p
DIP
No
DeckNotel)
Type
Fasten
Attach
D. o �_
ly
SELF-ADHOUNG BASE PLY:
W-136
Min. 19/32-
Elastobase, Elastobase P
Dekfast Hex (aka, Dekfas.t PLT-H-2-7/8) with Dekfast #14
12-inch o.c. in 4-inch lap and 12-Inch o,c. in two
SBS-SA
SBS-SA, APP-SA, SBS-
-52.5-
inch plywood
(poly -film top)
or Trufast 3" Metal Insulation Plate with Trufast HD
(2), equally spaced, staggered center rows
TA, APP-TA
W-137
Min. 19132-
Elastobase, Elastobase P
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14
12-inch o.c. In 4-Inch lap and 12-inch o.c. in two
Polyflex SA Base
APP-TA
-52.5-
inch plywood
(poly -film top)
or Trufast 3" Metal Insulation Plate with Trufast HD
(2), equally spaced, staggered center rows
W-138
Min. 19/32-
Elastobase, Elastobase P
OMG Flat Bottom Plates (square) with Roo I fgrip #12
12-Inch o.c. in 4-Inch lap and 12-Inch o.c. in two
SBS-SA
SBS-SA, APP-SA, SBS-
.60.01
inch plywood
(poly -film top)
(2), equally spaced, staggered center rows
TA, APP-TA
W-139
Min. 19/32-
Elastobase, Elastobase P
CIVIC Flat Bottom Plates (square) with Roofgrip 412
12-inch o.c. In 4-inch lap and 12-Inch o.c. in two
Polyflex SA Base
APP-TA
-60.0-
inch plywood
(poly -film top)
(2), equally spaced, staggered center rows
'TABLE IG: WOOD DECKS— NEW CONSTRUCTION ORREROOF(TEAR�04)
SYSTEM TYPE F: NOWINSULATEP, BONDED ROOF COVER
System
Roof Cover (Note 15)
Deck (Note 1)
Primer
MOP psJ
Joint Treatment
Base Ply
Ply
Cap 11
No.
None
None
(Optional) SBS-SA, SBS-
�APP SA�SBS_
Lnch'pIywoiO4,jF
TA, APP-TA
TA, APP-TA
W-141
Min 15/32-
(Optional) PG100
None
Polyflex SA Base
(Optional) APP-TA
APP-TA
-90.0
inch plywood
W-142
Min. 15/32-
PG100
None
SBS-SA
(Optional) SB5-SA, SBS-
SBS-SA, APP-SA, SBS-
-97.5
inch plywood
TA, APP-TA
TA, APP-TA
W-143
. Min. 15/32-
(Optional) PG100
Plywood joints are covered with 4-inch wide strips of Elast.flex SA V Plus, rolled into
Elastoflex SA V Base or
(Optional) SBS-SA, SBS-
SBS-SA, APP-SA, SBS-
-97.5
nch plywood
place to create continuous bond.
ElastoflexSAV FIR Base
TA, APP-TA
TA, APP-TA
WB-3000
None
SBS-SA
(Optional)
SBS-SA, APP-SA ' SBS-
-105.0
TA, APP-TA
(Optional) PG100
Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled into
ElastoflexSA V Plus or
(Optional) SBS-SA, SBS-
SBS-SA, APP-SA, SBS-
-135.0
place to create continuous bond.
ElastoflexSA V Plus FR
TA, APP-TA
TA, APP-TA
(Optional) PG20O
Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled into
Polyflex SA Base
(Optional) APP-TA
�APP-TA
-135.0
place to create continuous bond.
ExterharResearch and Design, LLC. d/b/a TrinitylERD Evaluation Report P9290.02.08-R20 for FILISS41-1122
Certificate ofAuthorization M9503 En" EDITION (2017) FBC NON-HVHZ EVALLIATION Revision ZO: 09/12/2017
Prepared by: Robert Nienninen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 394-1230 App endix 1, Page 21 of 59