EVALUATION REPORT
Polyglass USA, Inc. Evaluation Report P12060.02.09-R24
1111 West Newport Center Drive FL5259-R28
Deerfield Beach, FL 33442 Date of Issuance: 02/24/2009
(954) 233-1230 Revision 24:01/24/2023
SCOPE:
This Evaluation Report is issued under Rule 6IG20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nleminen, P.E.
for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 6" Edition (2017) Florida Building Code sections noted
herein.
DESCRIPTION: Polyglass Roof UnderlaVments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nleminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words uNEMOJ etc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECFION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at thejob site at the request of the Building Official.
This Evaluation Report consists of pages I through 14.
Prepared by:
Robert J.M. Niemlnen, P.E.
Florida Registration No. 59166, Florida DCA ANEI-983
The facsimile seal appearinams authorized by Robert Nlernlnen,
P.E. an 01/24/2018. This does not serve as an electronically
signed document.
CERTIFICATION OF INDEPENDENCE:
1, NEMOJetr- does not have, nor does It intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO I etc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial Interest In any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither NEMO I etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
ONEMOletc.
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category. Underlayment
Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the
following sections of the e Edition (2017) Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1504.3.1
Wind Uplift
FM "74
2011
1504.3.1
Wind Upitit
UL 1897
2012
1507.2.3/1507.1.1
Physical Properties
ASTM D226
2009
1507.2.4 / 1507.1.1, 1507.2.9.2
Physical Properties
ASTM D1970
2015
1507.3.3
Physical Properties
FRSAJTRl April 2012
2012
1507.11.2
Physical Properties
ASTM D6164
2011
1507.11.2
Physical Properties
ASTM D6222
2011
TAS110
Accelerated Weathering
ASTM D4798
2011
3. REFERENCES:
ingint
Examination
Reference
Date
FM Approvals (TST 1867)
Wind Uplift
3004091
01/12/2000
PRI (TST 5878)
Physical Properties
PRI01121
04/08/2002
FRI (TST 5878)
Physical Properties
PUSA-005-02-01
01/31/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-01
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-02
12/23/2002
PRI (TST S878)
Physical Properties
PUSA-013-02-03
12/23/2002
PRI (TST5878)
Physical Properties
PUSA-018-02-01
07/14/2003
PRI (TST 5878)
Physical Properties
PUSA-028-02-01
07/13/2005
PRI (TST 5878)
Physical Properties
PUSA-033-02-01
01/12/2006
PRI (TST 5878)
Physical Properties
PUSA-035-02-01
0912912005
PRI (TST 5878)
Physical Properties
PUSA-055-02-02
12110/2007
FRI (TST 5878)
Physical Properties
PUSA-061-02-02
01/28/2008
PRI (TST 5878)
Physical Properties
PUSA-075-02-01
02/2212008
PRI (TST 5878)
Physical Properties
PUSA-083-02-M
04/14/2008
PRI M 5878)
Physical Properties
PUSA-088-02-01
07/29/2009
IVITI (TST 2508)
Physical Properties
JX201-17A
04/01/2008
MTI (TST 2508)
Physical Properties
RX14E8A
01/29/2009
ERD (TST 6049)
Physical Properties
11752.09.99-1
02/08/2000
ERD (TST 5049)
Wind Uplift
11757.08.01-1
08/13/2002
ERD (TST 6049)
Wind Uplift
11776.06.112
01/16/2003
ERD (TST 6049)
Physical Properties
02200.07.03
07/14/2003
ERD (TST 6049)
Wind Uplift
P1740.01.07
DI/D4/2007
ERD (TST 6049)
Physical Properties
P5110.04.07-1
04/11/2007
ERD (TST 6049)
Wind Uplift
P9260.03.08
03/21/2008
ERD (TST 6049)
Physical Properties
P13450.08.09
08/13/2009
ERD (TST 6049)
Wind Uplift
P30540.11.09-Rl
11/30/2009
ERD (TST 6049)
Physical Properties
P11030.11.09-1
11nO12009
ERD (TST 6049)
Wind Uplift
PlIG30.11.09-2
11/30/2009
ERD (TST 6049)
Physical Properties
P11030.12.09-3
11/30/2009
ERD (TST 6049)
Physical Properties
P33350.06.10
06/25/2010
ERD W 6049)
Physical Properties
P33370.03.11
03/02/2011
ERD OW 6049)
Physical Properties
P33370.04.11
04/26/2011
ERD M 6049)
Physical Properties
P37300.10.11
10/19/2011
NEMO FTC, UIC. Evaluation Report P12060.02-09-R24
Certijkate afAuthonzaGon #32455 e EDITION (ZO17) FEIC NON-HVHZ EVALUATION FL5259-R28
Polyglass Rwf underlayments, (954) 233-1230 Revision 24:01124/2018
Page 2 of 14
4.
ONEMOjetc.
kaft
Examination
Reference
Date
ERD OW 6049)
Physical Properties
P40390.08.12-1
08/06/2012
ERD (TST 6049)
Physical Properties
P40390.08.12-2
08/07/2012
ERD (TST 6049)
Physical Properties
C41420.09.12-3
09/11/2012
ERD (TST 6049)
Wind Uplift
P39680.03.13
03/04/2013
ERD CW 6049)
Physical Properties
P45370.04.13
04/26/2013
ERD W 6049)
Wind Uplift
P1738.02.07-R2
04/29/2013
ERD (TST 6049)
Wind Uplift
11757.04.01-1-111
04/30/2013
ERD (TST 6049)
Wind Uplift
P41630.08.13
08/06/2013
ERD W 6049)
Wind Uplift
P22751.05.03-111
11/26/2013
ERD (TST 6049)
Wind Uplift
P11781.11.03-Rl
11/26/2013
ERD W 6049)
Physical Properties
P45270.05.14
05/12/2014
ERD (TST 6049)
Physical Properties
6020.07.14-1
09/08/2014
ERD (TST GD49)
Physical Properties
6020.09.14-2
09/08/2014
ERD (TST 6049)
Physical Properties
6020.09.14-3
09/08/2014
ERD CTST 6049)
Physical Properties
6020.09.14-4
09/08/2014
ERD (TST 6049)
Physical Properties
6020.09.14-S
09/08/2014
ERD W 6049)
Physical Properties
6020.09.14-6
09/08/2014
ERD (TST 6049)
Physical Properties
P46520.10.14
10/03/2014
ERD [TST 6049)
Physical Properties
P43290.10.14
10/17/2014
ERD (TST 6049)
Physical Properties
PLYC-50SSO.03.15
03/24/2015
EIRD (TST 6049)
Physical Properties
P40390.04.15
04/03/2015
ERD CM 6049)
Physical Properties
P44360.10.14-Rl
05/18/2015
ERD (TST 6049)
Physical Properties
PLYG-SC8080.05.15-1
05/20/2015
ERD (M 6D49)
Wind Uplift
PLYG-SC8905.05.16-1
05/17/2016
ERD (TST 6049)
Physical Properties
PLYG-SC8080.07.16
07/16/2016
ERD (TST 6049)
Wind Uplift
PLYG-SC12025.10.16
10/12/2016
ERD [175T 6049)
Physical Properties
PLYG-SC13040.12.16
12/27/2016
ERD (TST 6049)
Physical Properties
PLYG-SC11900.03.17
03/10/2017
ERD (TST 6049)
Physical Properties
PLYG-SC12115.08.17
08/08/2017
ICC-ES (EVL 2396)
IBC Compliance
ESR-1697
11/01/2014
Miami -Dade (CER 1592)
HVHZ Compliance
NCIA 14-0717.08
01/22/2015
Polyglass USA
Manufacturing Affidavit
Products Current
02/18/2009
Polyglass USA
P/1-Afficlavit
Mule,Hide Cross Ltg
03/01/2008
Polyglass USA
Materials Affidavit
Polystick SA Compound
08/18/2011
UL, U.C. (QUA9625)
Quality Control
Service Confirmation
Exp. 10/05/2018
PRODUCT DESCRIPTION;
4.1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet.
4.1.2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet
4.1.3 Polyglass G2 Base is a fiberglass -reinforced, asphaltic base sheet.
4.1.4 Polyglass APP Base is a fiberglass -reinforced, APP modified bitumen base sheet.
4.2.1 Polystick IVITS or Polystick IVITS PLUS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass
fiber reinforced, surfaced with polyalefinic film surface; meets FRSA/TRI April 2012.
4.2.2 PolVstick IRXe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an
aggregate surface; meets ASTM D1970.
4.2.3 Pohrstick TU Plus Is a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a
polyester fabric surface; meets ASTIVI D1970 and FRS / AfrRI April 2012.
NEMO ETC, LLC. Evaluation Report P12060.02.09-R24
Uru7wW qfAuthorka�n #32455 dr' EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-RZB
Po[Wglm Roof Underlayments; (9S4)233-1230 Revision 24: 01/24/2018
Page 3 of 14
ONEMOletc.
4.2.4 PoWick TU P Is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester
reinforced, with a granular surface; meets FRSA/TRI April 2012.
4.2.5 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/M2 polyester
fabric surface; meets ASTM D1970 and FRSA/TRI April 2012.
4.2.6 Polyflex: SAP, Polyflex: SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) are polyester
reinforced, APP modified bitumen cap sheets; meet FRSA/TRI April 2012.
4.2.7 Polystick Dual Pro� Is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyester fabric surface; meets ASTM D1970.
4.2.8 Polystick rile Prom is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2012.
4.2.9 Polystick MIJ-X is a nominal 54-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polypropylene film surface; meets AC188 and physical requirements of ASTM D1970 (See Section
5.8).
4.3.1 Elastoflex G IIJ is a polyester reinforced, modified bitumen tile underlayment composed of a sand -surfaced SIBS
modified bitumen back -side and grantife-surfaced APP modified bitumen top -side. Elastoflex G TU Is for use as an
alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April
2012 (04-12) beneath mechanically fastened tile roof systems or Hot Asphalt applied 'Cap Sheet" in the 'Two Ply
System" from FRSA/TRI April 2012 (04-3.2) beneath mechanically fastened or adhered tile roof systems.
4.3.2 Elastaflex SS 6 and Elastoflex S6 G FR are polyester reinforced, SBS modified bitumen cap sheets; meet ASTM D6164.
Elastoflex SIS G and Elastoflex S6 6 FR are for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380,
Class M) in the "Single Ply System" from FRSAITRI April 2012 (04-12) beneath mechanically fastened tile roof systems.
Elastoflex S6 G is for use as an alternate to Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI
April 2012 (04-2.2) beneath mechanically fastened or adhered tile roof systems. Elastoflex: SS 6 FIR is for use as an
alternate to Hot Asphalt applied "Cap Sheer in the "Two Ply System" from FRSA1TRI April 2012 (04-12) beneath
mechanically fastened tile roof systems.
4.3.3 Polyflex 6 and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets; meet ASTM D6222.
Polyflex G is for use as an alternate to Heat Applied "Cap Sheer in the "Two Ply System" from FRSA/TRI April 2012
(04-3.2) beneath mechanically fastened or adhered tile roof systems. Polyflex G FR Is for use as an alternate to Heat
Applied "Cap Sheet' in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile
roof systems.
S. LlivinrAtioNS:
5.1 This is a building code evaluation. Neither NEMOj etc. nor Robert Nlemlnen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically forthat purpose.
5.2 This Evaluation Report Is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval bas6d on this evaluation combined with supporting data for the prepared roof covering.
NEMO ETC, U.C. Evaluatlon Report P12060.02.00�R24
aMftW!e fAuth.&.t1..#3245S OEDMON (ZO17) FBC NON-HUNZEVALUATION FL5259-R28
Polygian Roof Underlayments; (954) 233-1230 RL-Asion 24:01/24/2018
Page 4 of 24
ONEMOjetc.
5.5 Allowable Roof Covers:
R,
Underlayment
AsphaltShlogles;
Nall -On Tile
Foam -On TIle
Metal
Wood Shakes
&Shmgles
Slate
Elastobase
Yes
Yes
(Ban5heetln2-ply�oernj
Yes
(Bane Sheat In 2-ply SVMM)
Yes
Yes
Yes
Elastobase P
Yes
Yes
(senesbeetIn2-plystertem)
Yes
(aans Sheet In 2-ply Wnent)
Yes
Yes
Yes
PolyElass G2 Base
No
Yes
(Bn,eSb.etIn2,Iyqnern)
Yes
(MnSheettn2-pty�nem)
No
No
No
Polyglass APP Base
No
Yes
(8n,eSheetIn2.p1ys,Wmj
Yes
(Ban Sheet In �ply qZern)
No
No
No
Polystick Mrs or MTS PLUS
Yes
Yes
No
Yes
Yes
Yes
Polystick IR-Xe
Yes
No
No
No
Yes
Yes
Polystick TU P
No
Yes
Yes (See 5.5.1�
No
No
No
Polystick TU Plus
Yes
Yes
Yes (See S.S.1)
Yes
Yes
Yes
Polystick TU Max
No
Yes
Yes (See S.S.1)
Yes
No
No
Polystick Dual Pro
Yes
N a
No
Yes
Yes
Yes
Polystick Tile Pro
Yes
Yes
Yes (See 5.5.1)
Yes
Yes
Yes
Polystick mu-x
No
No
Yes
Yes
Yes
Elastuflex 56 G
-Yes
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Elastollex S6 G FR
Yes
Yes
No
No
Yes
Yes
Elastollex G TU
Yes
Yes
Yes (SeeS.5.1)
No
Yes
Yes
Polyflex G
Yes
Yes
Yes (SeeS.5.11
No
Yes
Yes
Polyflex G FR
Yes
Yes
No
No
Yes
Yes
PolyflexSAP orSAP FR
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Mule -Hide SA-APP Cap Sheet
1 orSA-APPCapSheet(FR)
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
— I
5.5.1 "Foam-On'flle" is limited to use of the following Approved tile adhesives / underlayment combinations.
y",
Adhesive
Florida Product
Underlayments
Approval
DAP Foam Touch'n Seal Stomraond Roof
FL14506
PolystickILl Plus, PolystickTU Max
TileAdheslve
Dow'nieBond—
FL22525
PolystickTU P, PalystickTU Plus, Polyfl"SAP crTlIe Pro
Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro,
ICP Adhesives Polyset- AH-160
FL6332
Elastaflex G TU, Elastoflex S6 G, Polyflex G. Polyflex SAP, Polyflex SA Cap FR,
M ule-Hide SA-APP Cap Sheet or M ule-Hide SA-APP Ca p Sheet (FR)
Polystick TU P, Polystick TU Plus, Polystick TILI Max, Polystick Tile Pro,
ICP Adhesives Polyset's RTA-1
FL6276
Elastoflex G TU, Elastoflex S6 G, PolVflex G, Polyflex SAP, Polyfi ex SA Cap FR,
Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR)
1 Reftr to Tile Manufacturees orAdhesive Manufacturer's Florida ProductApprovalfor Overturning MDmentResLstance Performance.
NEMO ETC, I.I.C. Eviiluation Report P12060.02.09-R24
Gentlfwte ofAutharboven #32455 67" EDITION (2017) FBC NON-HVHZ EVALUATION FLS259-RZB
PolVglan Roof UndeflaVments; (954) 233-1230 Revision 24:01/24/2018
Page 5 of 14
ONEMO I etc.
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Dec :
Polystick (all variations), Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet
(FR) self -adhered to:
> New untreated plywood; ASTIVI D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing
plywood; New or existing, unprimed CISB; ASTM D41 primed CISB; Southern Yellow Pine; ASTM D41 primed
Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods '21P System" Panels
(designed and installed to meet wind loads for project).
Note. Polyglass does not require priming of new or existing plywood or CISB sheathing. New or existing plywood or
CISB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes.
Elastaflex G TU, Elastoflex S6 G or Elastollex SIS G FR in hot asphalt to:
> ASTIVI D41 primed structural concrete.
Polyflex G or Polyflex G FR torch -applied to:
> ASTM D41 primed structural concrete.
5.6.2 Bond -to -insulation;
Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered
to:
> ASTM C1289, Type 11, Class I polylsocVanurate or Type V poMsocyanurate-composite Insulation; Dens Deck
DuraGuard; Dens Deck Prime; orSECUROCK Gypsum -Fiber Roof Board.
El astaflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in h at asph a It to:
> Dens Deck Prime or SECURCICK Gypsum -Fiber Roof Board.
Polyflex G or Polyflex G FIR torch -applied to:
> ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum-FIber Roof Board.
For installation under mechanically attached prepared roof coverings, Insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile
systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of
the insulationjunderlayment system in accordance with FBC Section 2504.3.1.
5.6.3 Bond to Mechanically Attached Base Laver:
Polystick (all variations), Polyflex SAP or SAP FIR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or
Tile Pro self -adhered to:
> ASTM D226, Type I or 11 felt; Elastobase; Elastobase P or Mule -Hide Nail Base.
Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FIR In hot asphalt to:
> ASTM D226, Type I or H felt; Elastabase; Elastobase P, Mule -Hide Nail Base or Polyglass G2 Base.
Polyflex G or Polyflex G FIR torch -applied to:
> Elastobase; Elastobase P, Mule -Hide Nail Base, Polyglass 62 Base or Polyglass APP Base.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For Installations under foam -on tile systems, base layer shall be attached per minimum
requirements of FRS" April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in
accordance with FBC Section 1504.3.1.
NEMO ETC, LLC Entuation Report P12060.02.09-R24
EDITION (2017) FBC NON-HVHZ EVALUATION FLSZ59-RZ8
PoIygI= Roof Underlayments; (954) Z33-2230 Revision 24:01/24/2018
Page 6 of 14
ONEMOIetc.
5.6A Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI Apfil 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment
forms part of the load -path. The follovding wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the
result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure
divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-
12), Appendix A, Table IA or FBC 1609 for determination of design wind loads.
#1 Maximum Design Pressure � -90 p
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: None
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Pclyfl� SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#2 Maximum Design Pressure = -97.5 pst.
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PGIG0 or ASTM D41
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x
1%" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 22-Inch c.c.
#3 Maximum Design Pressure = -205 ast
Deck: Min. IS/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: WB-3000
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Potystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (ER), self -adhered and back -nailed within the selvedge -edge side laps using 22 ga. x
1X" ring shank nails through 32 ga., 1-5/8" diameter fin caps spaced 12-inch o.c.
#4 Maximum Design Pressure = -135 psf
Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional) PG100 or ASTIVI D41
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Joints: Min. 4-inch vificle strips of Elastoflex SA-V over all plywood joints.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, PolyfleX SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#5 Maximum Design Pressure � -315 v :
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, 'Ille Pro, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap
Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#6 Maximum Design Pressure -- -622.5 psf
Deck; Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PGI0D or ASTM D41
Underlayment: Elastoflex G TU or ElastoflexS6 G, applied in full mapping of hot asphalt or Polyflex G, torch -applied.
#7 Maximum Design Pressure = -30.0 psf*:
Deck: Min. IS/32-inch OSB to meet project requirements to satisfacrion of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hicle Nall Base (poly -film top surface)
Fasteners: 11 ga. x 1.254nch longx I -inch head diameter round metal cap nails
Spacing: 6winch o.c. at the 3-incb wide side laps and 6-Inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
NEMO Err, LLC. Eviiiiiation Report P12060.02.09-1124
Cefflfi� cfAufho��n #32455 e" EDMON (2027) FBC NON4iVHZ EVALUA'nGN FLSZS9-RZR
Polyglass Roof Underlayments; (9541233-2230 ReWsion 24: 01/24/2018
Page 7 of 14
ONEMOletc.
#8 Maximum Design Pressure= -37.5 psf*
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 13. ga. x 1.25-Inch long x 1-inch head diameter round metal up nails
Spacing: 6-Inch o.r at the 3-Inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Poly5tick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflac SAP FIR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#9 Maxlmurri Design Pressure = -37.5 psf*
Deck: Min. 19/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (1) or two (2) layers ASTM D226, Type 11 felt
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 124nch c.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastaflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
#10 Maximum Design Priassure = -45 psf*:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (1) layer ASTM D226, Type 11 felt
Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank noofing nails at 1-5/8-Inch diametertincaps
Spacing: 4-inch o.c. at the 2-Inch wide side laps and 4-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional; for use with self�adhering underlayment only) PoW!ck MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule,Hide SA-APP Cap Sheet (FR), self -adhered or Elastoflex G TU, applied in full mopping of hot asphalt
#11 Maximum Design Pressure = -45 psf*;
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Two (2) layers ASTM D226, Type 11 felt
Fasteners: 11 ga. x 1.25-Incb long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-Inch diametertincaps
Spacing: 9-Inch o.c. at the 2-Inch wide side laps and 9-Inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional; for use with self -adhering underlaymerit only) Polystick MTS or Polystick MT5 PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule-Hicle SA-APP Cap Sheet (FR), self -adhered or Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot
asphalt.
#12 Maximum Design Pressure = -45 vsf:
Deck:
Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase (sanded top surface for hotasphaft or torch -applied cap or poly -film surface for torch -applied up)
Fasteners:
Simplex MAXX Cap Fasteners
Spacing:
9-inch o.c. at the 2-inch wide side laps and 18-Inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastaflex G TU or Elastoflex SIS G, applied in full mapping of hot asphalt or Polyflex G, torch -applied.
#13 Maximum Design Pressure = -52.5 p
Deck:
Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase (sanded top surface for hot -asphalt or torch -applied up or poly -film surface for torch -applied cap)
Fasteners:
Simplex MAXX Cap Fasteners
Spacing:
9-inch o.c. at the 2-Inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastaflex 56 G, applied in full mopping of hot asphalt or PoWex 6, torch -applied.
#14 Maximum Design Pressure —�_-�52.5 sf
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elambase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: Simplex Original Cap Nails
Spacing: 6-Inch o.c. atthe 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
NEMO ETC, I.I.C. Evaluation Report P12060.02.09-1124
�rtlj7wte of Autharizition #32455 EDITION (2017) FBC NON-HVHZ EVALUATION FL52S9-R28
Polyglass Roof Underlayments; (934) Z33-1MO Revision 24: 01/24/2018
Page 8 of 14
ONEMOletc.
#15 Maximum Design Pressure = -52.5 p
Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet; Elastobase (sanded top surface for hot-asphait ortorch-applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c at the 3-Inch Wide side lops and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastaflex G TU or Elastaflex S6 G, applied in full mapping of hot asphalt or Polyfleit G, torch -applied.
#16 MaAmurn Design Pressure = -60 P
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hat -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin ups
Spacing: B-Inch o.c. at the 4-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastaflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#17 Maximum Design Pressure = -60 a
Deck: Min. 19/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied up)
Fasteners: OMG #12 Standard Rooflirlp with CIMG Flat Bottom Metal Plates
Spacing: 12-inch o.c. at the 4-Inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastofleii 6 TU or Elastoflex SIS G, applied in full mopping of hot asphalt or Polyfl" G, torch -applied.
#18 Maximum Design Pressure = -67.5 p :
Deck; Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment)
Fasteners: 12 ga. x 1.25-inch longx 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin ups
Spacing: 8-inch o.c. at the 4-Inch wide silde laps and 8-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastofl" G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or torch -applied or Polyflu G, torch -
applied.
#19 Maximum Design Pressure = -75 p
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch�ppfted underlayment)
Fasteners: Dekfast #14 with Deklast Heii plates, OMG #14 HD with OMG 3' Galvalume Steel Plates, CMG Roofgrip #14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-Inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: 10-Inch a.c. atthe 4-Inchwide side laps and 10-Inch o.c. atthree (3) equally spaced staggered center rows.
Underlayment: Elastoff" G TU or Elastciflm S5 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -
applied.
#20 Maxim urn Design Pressure= -90 A
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastabase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simpim MA)O(Cap Fasteners
Spacing: 6-inch o.c. at the 2-inch wide side laps and 6�lnch a.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflax S6 G, applied in full mopping of hot asphalt or Polyflex 6, torch -applied.
#22 Maximum Design Pressure = -90 p
Deck: Min. 15132-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastabase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface fortorch-applied cap)
Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with CMG 3" Round Metal Plates or CMG Flat Bottom Metal
Plates
Spacing; &inch o.c. at the 4-Incb wide side laps and 6-Inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastall" S6 G, applied in full mopping of hot asphalt or Polyflaic G, torch -applied.
#22 Maximum Design Pressure = -90 p
Deck: Min. 15132-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast #12 DP or Trufast #14 HO with Trufast 3" Metal Insulation Plates
Spacing: 6-inch o.c. at the 4-Inch wide side laps and 64nch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastotlex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt
NEMOETC,LLC. Ewluatlan Report P12060.02.09-1124
UM)WW ofAuthorhitiffan #32455 EDmori (20171 FBC NON-HVHZEVALUA71ON FL5259-RZB
Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018
Page 9of24
ONEMOletc.
#23 Maximum Design Pressure = -90 to
Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having.lurisdictlon.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underloyment)
Fasteners: Deldiast #14 with Delchist Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roafgrip #14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-Inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastaflex G TU or Elastoflex SS G, applied In full mopping of hot asphalt or torch -applied or Polyflex G, torch -
applied.
#24 Maximum Design Pressure= -97.5p
Deck: Min. 3.9/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nall Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch x 3/8-Inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-Inch o.c. at the 4-Inch wide side laps and 4-Inch o.c. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystlick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#25 Maximum Design—P—re—ss—ur—e—=--I—OS-Ps—f-.
Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastabase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXXCap Fasteners
Spacing: 64nch o.c. at the 2-Inch Wide side laps and 64nch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastollex 6 TU or Elastailex S6 G, applied In full mopping of hot asphalt or Polyflex 6, torch -applied.
#26 Maximum Design Pressure = -112.5 p
Deck: Min. 19/324nch plywood to meet project requirements to satisfactlan of Authority Having Jurisdiction.
Base Sheet: Elastabase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch x 3/8-Inch head diameter annular ring shank roofing nails at 1-5/8-Inch diameter tin caps
Spacing: 6-Inch mc at the 4-inch wide side laps and 6-Inch o.c. at four (4) equally spaced staggered center rows.
Primer: PGIGO or ASTM D41 primer at all tin -caps
Base Ply: Polystick MTS or Polystick MTS PLUS, self -adhered
Underlayment: Poiystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, PolyflexSAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#27 Maximum Design Pressure = -120 p
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet; Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roafgrj*p or OMG #14 Heavy Duty with OMG 3' Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing: 6-Inch o.c. at theVinch wide side laps*and 6-Inch o.c. at five (5) equally spaced staggered center rows.
Underlayment: Elastaflex 6 TU or Elastaflex 56 G, applied In full mapping of hot asphalt or Polyflioi G, torch -applied.
#28 Maximum Design Pressure = -120 A
Deck; Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet; Elastobase (sanded top surface)
Fasteners: Trufast #12 DP or Trufast #14 H D with Trufast 3" Metal Insulatio n Plates
Spacing: G-Inch o.c. at the 4-Inch wide sf de laps a nd 6-inch o.c. at five (5) eq ual ly spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastaflex S6 G, app lied in full m opping of hot aspha It.
5.6A.1 All other direct -deck, adhered Polyglass undeflayment systems beneath foam -on tile systems carry a Maximum
Design Pressure of -45 psf.
NEMOETC,U.C. Ewluation Report P12060-02.09-R24
Gerrific,te of Avdw�an 032455 e EDITION (ZO17) FBC NON-HVHZ EVALUATION FL5259-RZS
Polyglass Roof Underlayments; (954) 233-1730 RevIslon 24: 01/24/2028
Page 10 of 14
ONEMOjetc.
5.6.4.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed
that required under FRSAjTRI April 2012 (04-12), Appendix A, Table IA.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone I design
pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density
designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are
ANSI/SPRI WDI, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked
with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January
2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30-days
after installation.
Polystick IR-Xe or Polystick MU-X shall not be left exposed for longer than 90-days after installation-
Polystick IVITS, MTS PLUS, TU P, TU Plus, TU Max, Qual Pro, Tile Pro or Elastoflex G TU shall not be left exposed for
longerthan 3.80-days after installation.
Polyflex: SAP or SAP FIR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure
limitation, unless the prepared roof covering is to be adhesive -set file, in which case the maximum exposure is 30
days.
Elastoflex S6 G or Elastoflex SIS G FR or Polyflex G or Polyflex G FR does not have an exposure limitation, unless the
prepared roof covering is to be adhesive -set tile (Elastaflex S6 6 or Polyflex 6 only), in which case the maximum
exposure is 180 days.
5.8 PoWick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226
roofing felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller, as
set forth in Section 4.3, Note 1 of ASTM D1970-15, should be established as to slip resistance.
5.9 Tile Slippage Limitations (FRSA/TRI April 2012 (04-12)):
When loading roof tiles on the underlayment In direct -deck tile assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
Underlayment
Tile Profile
Staging Method
Maximum Slope
Elastoflex G TU
Flat
10-tile stack
7:12
Lugged
8-tile stack (15 over 2)
6:12
Elastoflex S6 G or S6 6 FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polystick MTS or MTS PWS
Flat
G-tile stack (4 over 2)
5:12
Lugged
6-tile stack (4 over 2)
4:12
Polystick Tile Pro
Flat or Lugged
6-tile stack (4 over 2)
7:12
Polystick TU Max
Flat
6-tile stack (4 over 2) or 10-tile stack
7:12
Lugged
6-tile stack (4 over 2)
7:12
Lugged
10-tile stack
6:12
PolystickTU P
Flat
6-tile stack (4 over 2)
6:12
Lugged
&tile stack (4 over 2)
4:12
PolystickTU Plus
Flat or Lugged
6-tile stack (4 over 2)
7:12
Flat or Lugged
10-tile stack
6:12
Polyflex G or G FIR
Flat or Lugged
6-tfle stack (4 over 2)
Polyflex SA P or SA P FIR
Flat or Lugged
6-tile stack (4 over 2)
4:112
NEMO ETC, U.C. Evaluation Report P12060.02.09-R24
Ceniftcote ofAuthorkatbn #32455 15�"EDITION (ZO271 FBC N ON-HVHZ EVALUATION FLSZS9-RZB
Pobalan Roof Underlayinents; (954) 233-2230 Revision 24: 01/2412018
Page 11 of 14
ONEMOletc.
6. INSTALLATION:
6.1 Polyglass Roof UnderlaVrnents; shall be installed in accordance with Polyglass published installation requirements
subject to the Urnitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any ]case decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application, and prime the substrate (if applicable).
6.3.1 Non -Tile Applications:
Shall be installed In compliance with the codified requirements for ASTM D226, Type 11 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA
P FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (Flit), self -adhered, Elastaflex 6 TU, Elastaflex S6 6 or
Elastoflex SIS 6 FR in hot asphalt or Palyflex 6 or Polyflex G FR, torch applied. Roof cover limitations are those are
those associated with the top -layer underlayment, as set forth in Table 1.
6.3.2 Tile Applications:
-Elastobase, Elastobase P or Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the rwo
Ply System" from FRSA/TR1 April 2012 (04-12). Reference is made to Table I and Section S.6.4 herein, coupled with
FRSAfTRI April 2012 (04-12) Installation Manual.
V
&4_1 Shall he installed In comnilance with the codified reauirements for ASTM D1970 (except PoIvstickTU P) underlayment
6.4.2
In FBC Table 1507.1.1 for the type of prepared roof coveringto be installed.
Dinect-to-Deck with Mechanically Fastened Roof Coven:
All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA-APP
Cap Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage edge seam in accordance with Polyglass / Mule -
Hide back nailing guidelines. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 14nch
diameter metal disk or SImplex-tVpe metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back -
nailed using the above noted fasteners and spacing, in area marked 'nail area, area pare clever" on the face of
membrane. The head lap membrane is to coverthe area being back -nailed.
All seal -lap seams (selvage laps) must be
firmly rolled with a minimum 28 lb. hand
railer to ensure full contact and adhesion.
For Dual Pro and Tile Pro, align the edge of
the top sheet to the end of the glue pattern
(the sheetwill overlap the fabric).
view of ovelap S�rn of Owl Pro and Tile Poo
All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyplus; 50 Premium Modified
Wet/Dry Cement or Palyglass PGSOO Modified Cement applied in between the application of the lap.
Polystick TLI Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys,
or exposed roof to wall details
IYENIOETCpI.I.C. Evaluation Report P12060.02.09-RZ4
�ftorte offtth.�Vo. 932455 e EDITON 12017) FBC N0N-HVHZ EVALUATION FL5259-RZE
PolyglaW Roof Underlayinerio; 1954) 233-1Z30 Revision 24:01124/2018
Page 12 of 14
NNEMOjetc
Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or
Polyglass PGSOG Modified Cement to the area in need of repair, followed by a minimum 6 x 6 inch patch of the
Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be
installed in a water shedding manner.
All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a
minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied
for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min. 28 111 roller) or small areas of the
roof that are not accessible to a large roller or broom.
6.4.3 Tile Applications thot allowed for Polystick Dual Pro, IR-Xe or Pblystick MUXJ:
Reference is made to FRSA/TR1 April 2022 (04-12) Installation Manual and Table 1 herein, using the instructions
noted above as a.guldellne.
For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base
Sheet fastening shall be not less than FRSA/TR1 April 2012 (04-12), Table 2.
For adhesive -set tile applications, refer to Section 5.6.4 herein.
6.4.4 Two (2) Ply Underlayment Systems:
Polyslick MTS or MTS PLUS followed by PolVsfick MTS, MTS PLUS, TILI P, TU Plus, TU Max, Tile Pro, MU-X or Polyflex
SAP is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with
the top -layer material. This Is not a requirement, but is allowable if a 2-ply underlayment system is desired.
Polyistick NITS or MTS PLUS followed by Polystick TLI P, TLI Plus, TLI Max, Tile Pro or Polyflex SAP is allowable for use
under foam -on tile systems. Limits of use are those associated with the top -layer material. This is not a requirement,
but is allowable if a 2-ply underlayment system is desired.
6.5.1 Elastoflex IS TU, Elastaflex SG G or Elastaflex SS G FR shall be installed in compliance with current Polyglass published
installation requirements. For use in tile applications:
V Elastoflex 6 TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the �Single
Ply System" from FRSA/TRl April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" in the "rwo Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
Elastoflex S6 6 is for use as an alternate to 'Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply
Systemn from FRSA/TRl April 2012 (04-22) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet7 in the "rwo Ply System" from FRSAJTRI April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
v' Elastoflex S6 G Fit is for use as an alternate to "Mineral Surface Roll Roofing' (ASTM D6380, Class M) in the 'Single
Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" In the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile
roof systems.
6.5.2 For hot -asphalt -applications, Elastoflex G TU, Elastoflex SIS 6 or Elastaflex S6 6 FIR shall be fully asphalt -applied to the
substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, off -set
minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hat asphalt
with asphalt extending approximately 3/8-inch beyond the lap edge.
6.6.1 Polyflex G or PoWex G Fit shall be installed in compliance with current Polyglass published installation requirements.
For use in tile applications:
V Polyflex 6 is for use as an alternate to the Heat Applied "Cap Sheet" In the `rwo Ply, System" from FRSA/TRI April
2012 (04-12) beneath mechanically fastened or adhered tile roof systems (Base Sheet Limited per 5.6.3).
Polyflex G Fit is for use as an alternate to the Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TR1
April 2012 (04-12) beneath mechanically fastened tile roof systems (Base Sheet Limited per 5.6.3).
NENIO ETC, I.I.C. Evaluation Report P12060.02.09-1124
cawflcate of Authortwthn #32455 0 E017ION (2017) FBC NON-KVHZ EVALUATION FL5259-RZB
Pulyglaw Roof UndeflaymerdS; (934) 233-1Z30 RevWun 24:01/24/2018
Page 13 of 14
ONEMOletc.
6.6.2 Polyflex G or Polyflex 6 FR shall be fully torch -applied to the substrates noted In Section 5.6. Side laps shall be
minimum 3-inch and end -laps minimum 6-Inch wide, off -set minimum 3 feet from course to course. Side and end
laps shall be fully heat -welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap
edge.
6.7 Tile staging:
6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to
Table 2 herein, and Polyglass published requirements for tile staging.
6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TR1 April 2012 (04-12) must be used
an all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or nall-
boards, to prevent tile sliding and/or damage to the underlayment during the loading process.
6.7.3 Polyglass specifies the minimum cure time after installation of self -adhering membranes and before loading of
roofing tiles is forty-eight (48) hours.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8. MANUFACIURING PLANTS:
Contact the noted QA agency for Information on product locations covered for F.A.C. 61G20-3 CIA requirements. The following
plants have qualified products under their respective physical properties specifications.
Fernley, NV, Hazleton, PA & Winter Haven, FL
ASTM D1970
Polystick MU-X
Hazleton, PA
M-D 13-0004
Elastoflex G TU
Hazleton, PA & Winter Haven, FL
ASTIVI D1970
Polystick IR-Xe
ASTM D1970 & FRSA/TRl April 2012
Polystick TU Plus
ASTM D1970 & FRSAITRI April 2012
Polystick TU Max
Tuscaloosa, AL
ASTM D4601, Type 11
Polyglass 62 Base
Winter Haven, FL
ASTM D226 (physimls)
Elastobase, Elastobase P
ASTM D6509
Po]Vgla� APP Base
FRSA/TRI April 2012
Polystick MTS, Polystick MTS PLUS
FRSAITRI April 2012
Polystick TU P
FRSA/TRl April 2012
PolVflex SAP, Polyflex SA P FR
ASTM D1970
Polystick Dual Pro
ASTM D1970 & FRSA/TR1 April 2012
Polystick Tile Pro
ASTM D6164
Elastaflex S6. Elastoflex S6 G FR
ASTM D6222
PolVflex G. Polyflex G FR
9. QUAuTYASsuRANcE ENTITY:
UL, LLC — QUA9625; (314) 578-3406; k.chancellor@us.ul.com
-END OF EVALUATION REPORT -