HomeMy WebLinkAboutSUBMITTALPrepared For. SGM Engineering SCANNED BY Sold TO: St. Lucie Courlty Airstrion Submittal Date: June 8, 2018 REV: June 28, 2018 Customer P.O. Number. Customer Project Number. Job Number. Job Name: SLC - Admin AHU Repi 0 REVIEWED El REVIEWED AS NOTED 0 REJECTED EI REVISE AND RESUBMIT corrections or comments made an equipment submittals or shop drawings during wis review do not relicrve con— tractor from compliance with requiremeato of the drav— ings, and specifications. This check is onV for review of general conformance with the design concept of the pro— ject Grid ger"d compiianca wa the information given in the contract documents. The contractor is responaime for. conforming and convIoUng all quantities and dcrum— ciams; selecting fabrication processes and technkiues of construction: coardmating We mark with W of all other trades, and perfonning his work in a ode and satisfactory manner. SGM ENGINEERING DATE7-2-2018 ey___IEmB Trane U.S. Inc. is pleased to provide the enclosed submittal for your review and approval. Product Summary Qty Product 2 Performance Climate Changer (AHU-2 & AHI 6M, Chris Cowling Trane 6965 Vista Parkway North, Suite 11 West Palm Beach, FL 33411 Phone: (561) 683-1521 Cell: (561) 683-1521 Fax: (561) 697-8714 , flu afracnera mrormarnm crescruses; me equipment we propose to furnish for this project, and is submitted for your approvat Productpetformance andsubmittal data is valid fare period of 6 months from the date ol'submittal generation. If six months armore has elapsed between submittal generation and equipment release, the product performance and submittal data.will need to be verified. ItIsthe customer's responsibility to obiain such verification. Response to Engineer's Comments dated 6/26/18: a Performance on previous submittal differed because UU coils were used in lie� of UW coils. UU coils are high performance, low water pressure drop coils. Also, Fan diameter on AHU-2 was different to provide an operating point further away for the stall line since a VAV system."'All �hhandes have been 'made to restore the AHU I . f selections back to their original performance specification per the engineer`s;a2UV.Lt. Original Notes: 0 Contractor to review submittal for accuracy before ordering. DA?E- ELEC: DATE. KUM DATE. rm�- �-a_fj J.-LIOBS146151551131REV Submittal- AHUs - SLCAdmin AHU Repil Table Of Contents Product Summary Field Installed Options - PartfOrder Number Summary Performance Climate Changer ...................................................... ................ I .... 3 ..................... 3 ..................... 5 .- ............ .... 7 ................... 11 ................... 27 ................... 29 ................... 34 ..... 35 SLC - Admin AHU Repi June 28, 2018 Tag Data - Performance Climate Chancier (Qtv: 2) 111tern JTa9(s) Q!X I Description I Model Number JAI JAHU-2 1 1 Performance Climate Changer (C AA) 1 CSAA030UA JA2 JAHU-4 11 1 Performance Climate Changer (C ) I CSAA021 UA Product Data - Performance Climate Changer Item: Al Qty: I Tag(s): AHU-2 Unit level options Indoor unit Unit size 30 6in. integral base frame UL listed unit Multiple composite handles/latches Warranty Standard 1 year Parts warranty only Air mixing section (Pos #1) Air mixing section Mixing box w1filter Door- right side Back damper - opposed blade Front full face opening Top damper - opposed blade 2in. filter frame MERV 8 Pleated media - 1 set (Fld) Coll section (Pos #2) Horizontal coil Medium Stainless steel drain pan Right side - drain connection Right side - coil supply Service panel coil connection side Unit coil height Cooling coil Chilled water Type "UW" coil 8 rows 123 fins per foot nominal fin spacing Aluminum fins Delta flo H (Hi efficient) .016" (0.406 mm) copper tubes 1/2in. tube diameter (12.7 mm) Galvanized steel coil casing Fan section (Pos #3) Fan section Supply fan Door- right side Outward swing 25in. diameterAF, M press Top -back discharge Right side drive Dual -belt sheaves NEMA premium compliant TEFC Voltage 460/3 20 HP 1800 RPM Inverter balance with shaft grounding ring Motor wiring conduit External junction box Item: A2 Qty: I Tag(s): AHU-4 Unit level options Indoor unit FLD = Fumished by Trane U.S. Inc. lInstalled by Equipment Submittal Page 3 of 36 Others SLC - Admin AKU Repi June 28, 2018 Unit size 21 6in. integral base frame UL listed unit Warranty Standard 1 year Parts warranty only Air mixing section (Pos #11) Air mixing section Mixing box w/filter Door- left side Back damper - opposed blade Front full face opening Top damper - opposed blade 2in. filter frame MERV 8 Pleated media - 1 set (FId) Coil section (Pos #2) Horizontal coil Medium Stainless steel drain pan Left side - drain connection Left side - coil supply Service panel coil connection side Unit coil height Cooling coil Chilled water Type "UW" coil 8 rows 137 fins per foot nominal fin spacing Aluminum fins Delta flo E (Energy efficient) .016" (0.406 mm) copper tubes 1/2in. tube diameter (12.7 mm) Galvanized steel coil casing Fan section (Pos #3) Fan section Supply fan Door- left side Outward swing 18in. diameter AF, H press Top -back discharge Left side drive Dual -belt sheaves NEMA premium compliant TEFC Voltage 460/3 15 HP 1800 RPM Inverter balance with shaft grounding ring Motor wiring conduit External junction box FLD = Fumished by Trane U.S. Inc. I Instaffed by Equipment Submillat Page 4 of 35 Others SLC - Admin AHU RepI June 28, 2018 Performance Data - Performance Climate Changer Tags AHU-2 AHU-4 Unit level options Position Length (in) 116.750 98.500 Width (in) 93.600 80.000 Height (in) 65.000 66.250 Rigging weight (1b) 3140.2 2347.1 Installed weight (1b) 3349.7 2496.5 Actual airflow (dm) 14430 9470 Shipping split 1 weight (1b) 678.1 478.4 Shipping split 2 weight (1b) 1005.3 776.9 Shipping split 3 weight (1b) 1666.4 1241.2 Fan section Position #3 #3 Fan airflow (cfm) 14430 9470 Overall ESP (in H20) 3.000 2.900 Total static pressure (in H20) 4.642 4.439 Fan pressure drop (in H20) 3.000 2.900 Fan outlet velocity (ftIrnin) 2078 3284 Speed (rpm) 1456 2327 Total brake horsepower (hp) 15.095 11.703 Unit static efficiency (%) 69.96 66.62 Outlet area (sq ft) 6.95 2.88 Motor hertz (Hz) 60 60 Coll section Position #2 #2 Coil performance airflow (cfm) 14430 9470 Coil face area (sq ft) 29.90 20.81 Coil face velocity (ft/min) 483 1455 Coil section air pressure drop (in H20) 0.971 0.841 Coil rigging weight (1b) 550.7 416.9 Coil installed weight (1b) 760.3 566.2 Top or single coil dry weight (1b) 550.7 416.9 Leaving dry bulb (F) 50.00 50.00 Leaving wet bulb (F) 49.90 49.90 Entering dry bulb (F) 80.00 81.30 Entering wet bulb (F) 67.00 168.20 Fluid type Water Water Coil fluid percentage (%) 100.00 100.00 Entering fluid temperature (F) 42.00 42.00 Leaving fluid temperature (F) 57.00 67.00 Fluid temperature rise (F) 15.00 15.00 Standard fluid flow rate (gpm) 97.10 69.17 Fluid pressure drop (ft H20) 14.76 10.35 Fluid velocity (ft1s) 4.06 3.49 Fluid volume (gal) 25.07 17.86 Sensible capacity (MBh) 477.19 327.09 Total capacity (MBh) 730.77 620.57 Air mixing section Position #1 #1 Opening I back - airflow (cfm) 14430 9470 Opening I front - airflow (cfm) .30 9470 Opening 1 top - airflow (cfm) 1 3 Vo 70 l9i- Opening 1 back - area (sq ft) 12. 04 �.64 Opening I front - area (sq ft) 34.18 124.41 Opening 1 top - area (sq ft) 12.04 18.64 FLO = Fumished by Trane U.S. Inc. linstalledby Equipment Submittal Page 5of35 Others SLC - Admin AHU Repi June 28, 2018 Tags AHU-2 AHU4 Opening 1 back - face velocity (ft/min) 1199 1096 Opening 1 top - face veloci!y (ft/min) 1199 1096 Opening 1 back - pressure drop (in H20) 0.113 0.130 Opening I top - pressure drop (in H20) 0.113 0.130 Back inlet type Ducted Ducted Top inlet type Ducted Ducted Greatest entry PD (in H20) 0.113 0.130 Filter condition Mid-life Mid-life Filter airflow (cfm) 14430 9470 Filter area (sq ft) 56.67 33.33 Filter face velocity (ft/min) 255 284 Filter pressure drop (in H20) 0.557 0.568 Total mixing section pressure drop (in H20) 0.671 0.698 FLD = Fumished by Trane U.S. Inc. I Installed by Equipment Submittal Page 6 of 35 Others SLC - Admin AHU Rep[ June 28, 2018 Mechanical Specifications - Performance Climate Changer Item: Al, A2 Qty: 2 Tag(s): AHU-2, AHU-4 GENERAL Per ASHRAE 62.1 recommendation, indoor air handling units will be shipped stretch -wrapped to protect unit from in -transit rain and debris. Installing contractor is responsible for long term storage in accordance with the Installation, Operation, and Maintenance manual (CLCH-SVX07B-EN). Unit shall be UL and C-UL Listed. Supply fans within the scope of AHRI Standard 430 shall be certified in accordance with AHRI Standard 430. Unit sound performance data shall be provided using AHRI Standard 260 test methods and reported as sound power. Trane, in providing this program and data, does not certify or warrant NC levels. These levels are affected by factors specific to each application and/or installation and therefore unable to be predicted or certified by Trans. Refer to product data for specific fan footnote references. Unit Construction All unit panels shall be 2" solid, double -wall construction to facilitate cleaning of unit interior. Unit panels shall be provided with a mid -span, no -through -metal, internal thermal break. Casing thermal performance shall be such that under 550F supply air temperature and design conditions on the exterior of the unit of 81 OF dry bulb and 730F wet bulb, condensation shall not form on the casing exterior. All exterior and interior indoor AHU panels will be made of galvanized steel. Casing Deflection The casing shall not exceed 0.0042 inch deflection per inch of panel span at 1.00 times design static pressure. Maximum design static shall not exceed +8 inches w.g. in all positive pressure sections and -8 inches w.g. in all negative pressure sections. Floor Construction The unit floor shall be of sufficient strength to support a 300.0 lb load during maintenance activities and shall deflect no more than 0.0042 inch per inch of panel span. Unit base Manufacturer to provide a full perimeter integral base frame for either ceiling suspension of units or to support and raise all sections of the unit for proper trapping. Indoor unit base frame will either be bolted construction or welded construction. All outdoor unit base frames shall be welded construction. For indoor units, refer to schedule for base height and construction type. Contractor will be responsible for providing a housekeeping pad when unit base frame is not of sufficient height to properly trap unit. Unit base frames not constructed of galvanized steel shall be chemically cleaned and coated with both a rust -inhibiting primer and finished coat of rust -inhibiting enamel. Unit base height to be included in total height required for proper trap height. Insulation Panel insulation shall provide a minimum thermal resistance (R) value of 13 ft2-h-OFIBtu throughout the entire unit Insulation shall completely fill the panel cavities in all directions so that no voids exist and settling of insulation is prevented. Panel insulation shall comply with NFPA 90A. Drain Pan In sections provided with a drain pan, the drain pan shall be designed in accordance with ASHRAE 62.1. To address indoor air quality (IAQ) the drain pan shall be sloped in two planes promoting positive drainage to eliminate stagnant water conditions. Drain pan shall be insulated, and of double wall construction. The outlef shall be the lowest point on the pan, and shall be of sufficient diameter to preclude drain pan overflow under normally expected operating conditions. All drain pans connections shall have a threaded connection, extending a minimum of 2-1/2" beyond the unit base, and shall be made from the same material as the drain pan. Drain pan located under a cooling coil shall be of sufficient size to collect all condensate produced from the coil. Refer to Product Data for specific information on which sections are supplied with a drain pan, the drain pan material and connection location. Access Door Construction Access doors shall be 2" double wall construction. Interior and exterior door panels shall be of the same construction as FLD = Fumished by Trane U.S. Inc. / Installed by Equipment Submittal Page 7 oF35 Others SLC - Admin AHU Repl June 28, 2018 the interior and exterior wall panels respectively. All doors shall be provided with a thermal break construction of door panel and door frame. Gasketing shall be provided around the full perimeter of the doors to prevent air leakage. Surface mounted handles shall be provided to allow quick access to the interior of the functional section and to prevent through cabinet penetrations that could likely weaken the casing leakage and thermal performance. Handle hardware shall be designed to prevent unintended closure. Access doors shall be hinged and removable for quick easy access. Hinges shall be interchangeable with the door handle hardware to allow for alternating door swing in the field to minimize access interference due to unforeseen job site obstructions. Door handle hardware shall be adjustable and Visually indicate locking position of door latch external to the section. Door hinges shall be stainless steel. All doors shall be a minimum of 60" high when sufficient height is available or the maximum height allowed by the unit height. Door handles shall be provided for each latching point of the door necessary to maintain the specified air leakage integrity of the unit. Optionally for indoor AHUs and as standard on outdoor AHUs, outward swing doors are provided with a single handle linked to multiple latching points. An optional shatterproof window shall be provided in access doors where indicated on the plans. Window shall either be single pane, or thermal dual pane, as defined on schedule. Window shall be capable of withstanding unit operating pressures and shall be safe for viewing UV-C lamps. Refer to Product Data for specific information on which sections are supplied with an access door, the door location, a single handle and a window. MIXING SECTION A mixing section shall be provided to support the damper assembly for outdoor, return, and/or exhaust air. Dampers Dampers shall modulate the volume of outdoor, return, or exhaust air. The dampers shall be of double -skin airfoil design with metal, compressible jamb seals and flexible blade -edge seals on all blades. The blades shall rotate on stainless -steel sleeve bearings. The dampers shall be rated for a maximum leakage rate of 3 cfmIft2 at I in. w.g. complying with ASHRAE 90.1 maximum damper leakage. All leakage testing and pressure ratings shall be based on AMCA Standard 500-D. Dampers may be arranged in a parallel or opposed -blade configuration. Dampers Dampers shall modulate the volume of outdoor, return, or exhaust air. The dampers shall be of double -skin airfoil design with metal, compressible jamb seals and flexible blade -edge seals on all blades. The blades shall rotate on stainless -steel sleeve bearings. The dampers shall be rated for a maximum leakage rate of 3 cfm/ft2at 1 in. w.g. complying with ASHRAE 90.1 maximum damper leakage. All leakage testing and pressure ratings shall be based on AMCA Standard 500-D. Dampers may be arranged in a parallel or opposed -blade configuration. The following specifications apply only to units with outside air and return air dampers, with actuators. The 5 year warranty applies only to these items. This unit contains Economizer that meets or exceeds all mandatory requirements prescribed by Title 24, including but not limited to: - 5 yr parts only warranty - Successfully tested to 60,000 Actuations - Less than 10 cfm/sq.ft. of damper leakage at 1 " WG per AMCA 500L Filters Mixing sections shall be provided with a filter rack as indicated in the Product Data and As -Built sections of the submittal. 2-inch pleated media filters made with 100% synthetic fibers that are continuously laminated to a supported steel -wire grid with water repellent adhesive shall be provided. Filters shall be capable of operating up to 625 fpm face velocity without loss of filter efficiency and holding capacity. The filters shall have a MERV 8 rating when tested in accordance with the ANSI/ASHRAE Standard 52.2. COIL SECTION WITH FACTORY INSTALLED COIL The coil section shall be provided complete with coil and coil holding frame. The coils shall be installed such t ' hat headers and return bends are enclosed by unit casings. If two or more cooling coils are stacked in the unit, an intermediate drain pan shall be installed between each coil and be of the same material as the primary drain pan. Like the primary drain pan, the intermediate drain pan shall be designed being of sufficient size to collect all condensation produced from the coil and sloped to promote positive drainage to eliminate stagnant water conditions. The intermediate pan shall begin at the leading face of the water -producing deVice and be of sufficient length extending downstream to prevent condensate from passing through the air stream of the lower coil. Intermediate drain pan shall include downspouts to direct condensate to the primary drain pan. The outlet shall be located at the lowest point of the pan and shall be sufficient diameter to preclude drain pan overflow under any normally expected operating condition. FLO= Furnished by Trane U.S. Inc. linstalled by Equipment Submittal Page 8 of 35 Others SLC -AdminAHU Repl June 28, 2018 In lieu of a door, an easily removable service panel shall be provided in sections as specified, to facilitate access to unit for periodic servicing, or for removal and replacement of coils. Removal of service panel will not impact the structural integrity of the unit. Hydronic coils shall be supplied with factory installed drain and vent piping to unit casing exterior. Piping is to facilitate field installation of automatic venting or drain valves on coils, which are not supplied with unit. Refer to the Product Data section of the submittal for the units andlor coils supplied with drain and vent piping. Water Coils (UP, WP, UW, UU, UA, 3W, 3U, W, SW, 5A, WD, 5D, D1, D2, P, or TT) The coils shall have aluminum fins and seamless copper tubes. Copper fins may be applied to coils with 5/8-inch tubes. Fins shall have collars drawn, belled, and firmly bonded to tubes by mechanical expansion of the tubes. The coil casing may be galvanized or stainless steel. Refer to the Product Data section of the submittal for the coil casing material. The coils shall be proof -tested to 300 psig and leak -tested under water to 200 psig. Coils containing water or ethylene glycol are certified in accordance with the AHRI Forced -Circulation Air -Cooling and Air -Heating Coils Certification Program which is based on AHRI Standard 410 within the Range of Standard Rating Conditions listed in Table I of the Standard. Certified units may be found in the AHRI Directory at www.anddirectory.org. Propylene glycol and calcium chloride, or mixtures thereof, are outside the scope of AHRI Standard 410 and, therefore, do not require AHRI 410 rating or certification. Coil connections are constructed of cast iron with female connections, steel block with female connections or steel pipe with male connections. Type P or TT coil connections do not extend out of unit casing. All other water coil types have connections that extend out beyond unit casing. Headers on downstream coil bank of staggered coil sections do not extend beyond the unit casing and must be completed by the on -site piping contractor. Tubes are 1/2" [13 mm] OD 0.016" [0.406 mm] thick copper. Fans that are selected with inverter balancing shall first be dynamically balanced at design RPM. The fans then will be checked in the factory from 26% to 100% of design RPM to insure they are operating within vibration tolerance specifications, and that there are no resonant frequency issues throughout this operating range. Inverter balancing that requires lockout frequencies inputted into a variable frequency drive to in order to bypass resonant frequencies shall not be acceptable. If supplied in this manner by the unit manufacturer, the contractor will be responsible for rebalancing in the field after unit installation. Fans selected with inverter balancing shall have a maintenance free grounding assembly installed on the fan motor to discharge both static and induced shaft currents to ground. AF FAN SECTION The fan type shall be provided as required for stable operation and optimum energy efficiency. The fan shall be a double -width, double -inlet, multiblade-type, airfoil (AF) fan. The fan shall be equipped with self -aligning, antifriction bearings with an L-50 life of 200,000 hours, as calculated per ANSI/AFBMA Standard 9. For any bearing requiring relubrication, the grease line shall be extended to the fan support bracket on the drive side. The fan shall be statically and dynamically balanced at the factory as a complete fan assembly (fan wheel, motor, drive, and belts). The fan shaft shall not exceed 75 percent of its first critical speed at any cataloged speed. Fan wheels shall be keyed to the fan shaft to prevent slipping. The fan shafts shall be solid steel. The fan section shall be provided with an access door on the drive side of the fan. Fan performance shall be certified as complying with AHRI Standard 430. Drive Service Factor The drives shall be constant speed with fixed -pitch sheaves. The drives shall be selected at a minimum 50 percent larger than the motor brake horsepower (1.5 service factor). Motor Frame The motor shall be mounted integral to the isolated fan assembly and furnished by the unit manufacturer. The motor is mounted inside the unit casing on an adjustable base to permit adjustment of drive belt tension (not applicable for direct drive plenum fans). The motor shall meet or exceed all NEMA Standards Publication MG 1 requirements and comply with NEMA Premium efficiency levels when applicable except for fractional horsepower motors which are not covered by the NEMA classification. The motor shall be T-frame, squirrel cage with size, type, and electrical characteristics as shown on the equipment schedule. Refer to the Product Data section for selected fan motors within each unit. Two-inch Spring Isolators The fan and motor assembly (on sizes 10 to 120) shall be internally isolated from the unit casing with 2-inch (50.8 mm) deflection spring isolators, furnished and installed by the unit manufacturer. The isolation system shall be designed to resist loads produced by external forces, such as earthquakes, and conform to the current IBC seismic requirements. FLD =Furnished by Trane U.S. Inc. I Installed by Equipment Submittal Page 9 of 35 Others The fan section with a belt -driven fan shag be provided with a multiple belt drive. Refer to the Product Data section of the submittal for selected fans with multiple belt drives. Motor Wiring Conduit The fan motor wiring shall be factoty-wired to the unit -mounted starterldisconnect, variable frequency drive, or external motorjunction box within flexible metal conduit of adequate length so that the fan vibration isolation, if applicable, will not be restricted. Refer to the Product Data section for fans with motor wiring conduit. Indoor Units with an External Motor Junction Box The fan section shag have motor leads extended to a factory -installed NEMA extemaijunction box to facilitate field supplied starter or VFD wiring and to maintain air leakage integrity of the casing. For units with a full -load amp rating less than or equal to 110 amps, the enclosure shag be a NEMA I enclosure. For units with a full -load amp rating greater than 110 amps, the enclosure shall be a NEMA 4 enclosure. Refer to the Product Data section fbr fans with an external motorjunction box. Lifting Instructions The air handling units must be rigged, lifted, and installed in strict accordance with the Installation, Operation, and Maintenance manual (CLCH-SVX07G-EN). The units are also to be installed in strict accordancewith the specifications. Units may be shipped fully assembled or disassembled to the minimum functional section size in accordance with shipping and job site requirements. Indoor units shall be shipped on an integral base frame (variable from the standard 2.5" to 8" height) for the purpose of mounting units to a housekeeping pad and providing additional height to properly trap condensate from the unit, The integral base frame may be used for ceiling suspension, external isolation, or as a housekeeping pad. Indoor sizes 3 to 30 will also be shipped with a shipping skid designed for forklift transport. Refer to the unit As -Built or Product Data section of the submittal for the base frame height of each unit. All units will be shipped with an integral base frame designed with the necessary number of lift points for safe installation. All lifting lugs are to be utilized during lift. The lift points will be designed to accept standard rigging devices and be removable after installation. Units shipped in sections will have a minimum of four points of lift. FLD = Fumished by Trane U.S. Inc. lInstalled by Equipment Submittal Page 10 of 35 Others 27- 31" IS It For maneuvering purposes, Include 1.125 Inches to "an ship split length for ovelapping panel flange. Flange will not add to overall Installed unit length shown. I E)demaljuncfionboxRH 2 TPSK discharge opening jo 31.750 x 31.750 3 Housed fan - 251n. diameter AF, M press Supply fan 20 hp 46013 4 Coolingcoll-B Colitype Ig UW 5 Damper top -apposed blade 28.500 x 71.000 > 6 Damper backopposed blado 26.500 x 71.000 7 In N.P.T.E 8 Angled filters Mors 27YAdthx55he h 31 width x 55 he:gh: P=F �Up: Indoor .,It Prop set Number. IV 7IRWO Integral base fmme� GIn. lntog:,:I�b.. �fmm, �ctualai��--ow. 14430 cfm P.�—.ahnt�cwer iPaint Unmaintedtfleld related Sales Office: R(aaInalinstalled Weiaht: 3140.2 IN 3349.8 to 1� SLC - Admin AHU Rapt June 28, 2018 As -Built - Performance Climate Changer Item : Al Qty: 1 Tag(s): AHILI-2 3, 21 IW33 �§_2j ji —1163/4— For rnaneuvering purposes, indude 1.125 Inches to each ship split lenath for overlapping pand flange. Flange will not add to ovarall Installed unit length s Pea # Module Length Weight 3 Fan section 56518 1666A0 2 Coll section 14118 1005.27 1 Air mWng secfion 46118 678.08 Installed Unit Weight 3349.75 lbs 23 Basic Overall Plan View: TOP - Measurements in Inches CP�KG MD DIMEWWNS MY VMY ffiON COWMCT 000WENrSIRErUM QFA�RO� DR4MNGS CONSTYrUMS AC�TANCE OF �ESE VA�CESIROT TO SCALE Unft size: 30 lob Name: [Unut Casing: 2in Double Wall Fown a E-M-C fln jProposal Number. Lmew P��..� fLF�slnt Unpainted/Field painted loalub ulflue; FLD = Furnished by Thane U.S. Inc. linstalled by Equipment Submittal Page 12 of 35 Others SLC -AdminAHU Repi June 28, 2018 As -Built - Performance Climate Changer Item: Al Qtv: I Tanis): AHU-2 R Right Side of Unit Detailed Plan View: Top - Measurements in inches E2] 6 Wa 14 -4 — ------ 46 vit 118 ft Side of Unit Detailed Plan View. Bottom - measurements in inch, �u�flffup: Indoor unit cfM Timm IntegW baso �me: ft. WOWW baw M Paint Unpaintedtfield painted jSales Office: 314UV FLD = Furnished by Trane U.S. Inc. lInstalled by Equipment Submittal Page 13 of 35 Others SLC - Admin AHU Repl June 28, 2018 As -Built - Performance Climate Changer Item : Al City: I Tag(s): AHU-2 7- I _V N.P.T. 21318 1/2' 7 TO -8 112-�- k-7--� -H-21/8 < ------ —26518 116314— D3 118 6518 6 Detailed Elevation View. Left - Measurements in Inches, OP�ING�Dl�SIONSMYVMYMOMM�CTDOCUM�IRM���PRO�DD�WNGSWNST�SACC�T�CEOP�CSEV�CESINOTMS� Unit size, 30 ob Name: �Nt CashW. 2in Doubl;Wall Foam VIEW. 14430 cfm osal Number. ERInt Unpainteciffield painted �S�aes'i3iice­: JRIO�edMgfit 314�W 3U91M FLD = Furnished by Tfane U.S. Inc. linstalled by Equipment Submittal Page 14 of 35 Others SLC - Admin AHU Repl June 28, 2018 As -Built - Performance Climate Changer Item: All Qty: 1 Tag(s): AHU-2 Detailed Elevation View: Back - Measurements in Inches 314D2W �.D% FLD = Furnished by Trane U.S. Inc. linstalled by Equipment Submittal Page 15 of 35 Others 14118 46118 32 E21 PTI) Ven 318" 7 k �NPTERelum 1�.5" 5. PT 2.5- (NPTE *Su i7 6318 I — L3 114 "0 5/8----; 3 1184::- NPTI National Pipe Thread Internal Connection NPTE National Pipe Thread External Connection OPENINGMDDIMENSIONSMYVMYFROMCOW�CT�CUM�Sl�URNOF�PROVEDO�MNGSCONSTITUTESA�m�OFTHESEV��SINOTMS� JnH size: 30 3 Name: A Cas[ng: 2[n Double Wall Foam ---------------- —po—s —I —N —Um—b—O R.— M�� Product gfoup: Indoor 'ntegral base frame: 61 — — — — FP r—o tual airflow: 14430 Gfm a r �alnt: Unpaintedfrield painted Sales Office: 0 > M m C? m 0 'n 46118 —14 118 66518 ; T ]A 16 Coil connection view L Measumments In Inches NPTI National Pipe Thread Internal Connection NPTE National Pipe Thread External Connection OR�ING AND DIMENSIONS MY VMY FROM CONTRACT DOCUMENTSI�RN OFARPROVED D)MWNGS CONSWUTES ACCEPrANCe OF MESE V�IANGES INOT TO SCALE Jng size: 30 b Name: jUnft CasIng: 21n Double Wall Foam tual airflow: 14430 cfm Pnoposal Number. F Sales Office: IRIggIngRastalled WeIght: 3140.2 W1 3q49 8 Ih 3roduct group: Indoor stagnal base frame: 61 �alnt UnpaIntediffeld paInted > M 1�3 CD Basic Service Clearanci --Plan In Inches - Measurements OPENINO AND DIMENSIONS MAY VMYFROM CONT�CT DOCUMENTSI�RN OF APPROVED GIMWNGS COMSTITLITES ACCEPTANCE OF THESE VARIANCES INOT TO S� Unft sIze: 30 Name: ising: 2ln Double Wall Foam Product group; Indoor tual airflow: 14430 cfm al Number �Rq,,'9'Z",'tI1',dVVm9ht Integral base fiame: 61 -::: PaInt; Unpainted/field painted lbales Office: 314�02W3349,81�b 0' ID q 4 1 FAemat junction box LH 2 TPSK discharge opening JD 19.000 x 22.130 3 Housed fan - 181n. diameterAF, H press Supply but 15 bp 46013 4 Coolingcoll-8 Colitype w Uw to 5 Damper top -opposed V blade 22.750 x 66.000 6 Damper back -opposed blade 22.760 x 66,000 1 1 ILI 11 7 Angled filters - Do rs o 7 22 OvAdth x 46 height 29 Wdli, x 46 height 14 518 1 19 ---j 1�22 314�� 5/8 22314 _418 56,114 t 6 603/8 14118 ,ship Spit hip Split 1241lbs 777lbs 341/8 �Shlp Spbl--- 478lbs 8112— For maneuvering purposes6 Include 1.125 inches to each ship split length for overlapping panel flanga. Flange will not add to overall Installed unit length shown. OPENINGMD�M�IONSMYVARYF�MCONT�CT�CUM�NT$IRETURNOPAPPRDV&UD�MNGS�NSTi�SAG��M�OFTHESEVAR��SINOTTOS� Unk size- 21 b Name: Unit Casing: 2m Double Wall Foarn Product �rouip: Indoor Propo a um or. Inlegral base frame, 61 tual airflow. 9470 cfm Faint: Unpaintedifield painted Sales Office: Rigginglinstalled Weight: 2347.2 IN 2496.5 lb SLC-AdminAHU 2018 As -Built - Performance Climate ( Item: A2 Qty: I Tag(s): AHU.4 13] For nuateuvefing purposes, Include 1.125 Inches to each ship split length for overtopping pand fiang� Flange will not add to overall Installed unit length Pos # Module Length Weight 3 Fan section 50318 1241.16 2 Coil section 14118 776.90 1 Air mixing section 341/8 478.42 Installed Unit Weight 2496.49 [bs FLD =Fumished by Trane U.S. Inc. I Installed by Equipment Submittal Page 20 of 35 Others SLC -Admin AHU Rep] June 28,2018 As -Built - Performance Climate Changer Item: A2 Qtv: 1 Teals): AHU-4 Ri ies 3, Side of Unit Detailed Plan View. 130tt0M - Measumments in inches n s e: �Iob Name: Unit Casing: 2in Double Wall Foam Pmduct gmup� Indo n Pmposal Number. Paint UnpaIntedifield painted 10aleS Office: A�� FLO = Fumished by Trane U.S. Inc. I Installed by Equipment Submittal Page 21 of 35 Others SLC AdmInAHU Repi June 28, 2018 As -Built - Performance Climate Changer Item: A2 Qtv: 1 Tag(s): AHU-4 V14-y 11LAd 717 19718 6 73/4 1."NPTE T 121/ 271 118 1 1/8� —7 353/4 <--14 90318— Detailed Elevation View: Left, Measurements in inches OP�ING AND UMENWONS MY VARYFROM CO�TRACTOOCUME=1REMW OFAPPRO� DRAWNGS CONST�S ACCEPTMCE OF �ESE VARMCESINOTM Sme Unft s1ze: 21 jUnit Caeng: 21n Double Wall F=n a Pmduct gmup: Indoor unit lnt�W b. ft.: ft. W�WW b.. ft cfm Office: PMPGSal NUMbeC Paint —lSales FLD = Fumishedby Trans U.S. Inc. lInstalledby Equipment Submittal Page 22 of 35 Others SLC - Admin AHU Rep] June 28, 2018 As -Built - Performance Climate Changer Item: A2 Qtv: I Tanis): AHU-4 Detailed Elevation View: Back - Measurements in inches I 7�9 P.W. .�C� FLD = Furnished by Trane U.S. Inc. Iffistalled by Equipment Submittal Page 23 of 35 Others -5D 318 141/8 —341/8 98112 NPTI :-National Pipe Thread Internal Connection NPTE : National Pipe Thread External Connection OPENING AND DIMENSIONS MY VMY FROM CONTRACT OOCUMENTSI�M OFAPPROVED DIRAMNGS CONSTITVTES ACCEPTANCE OF TVfESE VAMANCESINOT TO SCALE Unit size: 21 Name: Unit CasIng: 21n DoubTe Wall Foam Product group: Indoor Integml base frame: 01 :ual airflow., 9470 cfm _TR_1 Pmposal Number. PaInt UnpaInted/field paInted Sales Office: gg,.gj 1n'Nst","11,dW,19ht: 2347.2 IbI 2496.5 lb CD E P4 X C .s 0 0 Ila 14 1/8 50318 It VOK =.nt TE Return 2.5' NPTE /8* drain (NPTQ, 10 718 Coll connection view: Left - Measurements In Inches NPTI National Pipe Thread Internal Connection NPTE National Pipe Thread External Connection OP�ING AND DIMENSIONS MAY VMY FROM CONT�CT DOCUUENTSI�RN OF�PROVEV VfMWINGS CONSTITUTES ACCE�ANCE OF �ESE VARIANCES INOT TO S� Unit size: 21 1 lob Na Jun m �e,_ It Casing: 21n Double Wall Fee Irflo FrOposal Number. ua a vir. 9470 Cfm FRI-ggingfinstalled Welght 2347 Ilk' �Aft� 9 IN Product group: Indoor U...... Integral base fmme: Sin. Integral base frame Paint: Unpainted/field I 9 Q U3 (D 0 0 A) (D 0 y ) 7RAWO Pe MmvWaaW6mlyseJClmq« G` SLC - Admin AHU Repl June 28, 2018 Fan Curve - Performance Climate Changer Item: Al Qty: I Tag(s): AHU-2 C:) 5 7 - —6 5 4 co 3 - 2 Supply Size 30 Horizontal Draw-Thra 25 inch AF M Press - Single Fan 5000 10000 15000 20000 25000 30000 Aifflow (cfm) FLD = Furnished by Trane, U. S. Inc. / Installed by Equipment SubmIttat Page 27 of 35 Others SLC - Admin AHU Repl June 28, 2018 Fan Curve - Performance Climate Changer Item; A2 CIty: 1 Tag(s): AHU-4 C) 15 W 12.5 10.0 7.5 5.0 2.5 0.0 Supply Size 21 Horizontal Draw-Thra 18 inch AF H press - Single Fan B HP adjusted 5% for approsch ate drNe lose Unasize: IMB NEE. Motor Frequency: 60.0011z OperstingAuflow: 9470.OD der Opecalsag Static Pressure: 4.44 h H20 Operating RPM: 2327.00 Operating Brake Power. 11.70hp Attitude: 0.0D ft F Des�aTounp:70.00F M6- Max BHP: 12.41 bp 41 oAt Etllclorucy: 56.62 % 70 batw. 1428118 70 %W, 41T W, WME F4 hit 44 4V 0% 0" 0 0A F"05 hom I M-40 = , L-W�� " - I - NEW —�" - - ! Z�-a T! I d I W �qq N L MW -1 0 2500 5000 7500 10000 12500 15000 17500 Kirflow (cfm) FLD = Furnished by Tfane U.S. Inc. / Installed by Equipment SubmiM Page 28 of 35 Others EXAMPLE UNIT - NOT CONFIGURED AS SELECTED. X; > CD Service, Clearance 0 17 Filter mixing box 0 0 for Control Box (D > in ID (D C ra Fan Access go ov Q (D VFD Lights E > VFD G Fan C D D Gas heat E Access Note: At a minimum, these clearance dimensions am door Component All recommended on one side of the unit for regular Sizes service and maintenance. Refer to as -built submittal G (control box HV or for locations of items such as filter access doom, F coil, piping connections. motor locations, air box size large) 36 Sufficient clemrance must be provided on all aides of unit for removal of panels or section -to -section G (Box size small or 13 attachment. Clearance for starters, VFDs, or other high -voltage, devices must be provided per NEC medium) requirements. 21 25 30 35 40 so 57 Component 3 4 6 8 10 12 14 17 21 25 30 35 40 " 66 80 100 120 TALL TALL TALL TALL TALL TALL TALL A (filter) 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 52 56 58 58 B (coil, humidifier) 48 59 59 66 77 82 87 87 95 77 95 77 109 87 115 96 128 96 141 110 141 110 1 156 156 170 197 B (staggered coil) NIA N/A N/A N/A N/A N/A N/A WA 67 NIA 67 NIA 76 NIA 80 NIA 88 N/A 96 NZA 96 N/A 105 105 113 129 C (UV Lights) 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 52 56 58 58 C (TCAC) 43 59 59 1 63 175 1 81 83 83 68 75 58 75 1 83 83 75 59 83 1 83 83 83 83 83 83 63 75 1 83 D (Extemal Starter VFD, LV box or 61 61 61 61 61 61 61 61 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 64 Overiload box) 11=181, 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48] 4:8 48 48 48 48 48 48 48 VFD) I IT E (fan) 1 48 48 48 48 51 54 58 1 61 60 51 66 51 66 58 66 60 70 60 1 77 1 66 1 77 1 66 93 93 101 101 F (Gas Heat P� W—fiH.) I NIA I N/A 1 89 1 90 1 108 1 100 1 100 1 105 1 1151 N/A 1 115 1 N/A 1 118 1 NIA 1 136 1 NIA 1 140 1 NIA 1 156 1 NJA 1 156 1 NIA 1 170 1 179 1 180 1 NIA F (Gas Heat IntVastible) N/A I NIA 1 56 1 63 174 1 79 1 84 1 84 1 92 1 NIA 1 92 1 N/A 1 106 1 N/A 1 112 J.WA 1 125 1 N/A 1 138 1 N/A 1 138 1 N/A 1 1531 153 1 1671 194 Item: Al, A2 Qty: 2 Tag(s): AHU-2, AHU-4 Base Detail FLD = Fumished by Trane U.S. Inc. /Installed by Equipment Submittal Page 30 of 35 Others SLC - Admin AHU Repi June 28,2018 Accessory - Performance Climate Changer Item: Al, A2 City: 2 Tag(s): AHU-2, AHU4 EXPAND GRIDBACKIN STANDARD CONSTRUCTION 1. 100 % Synthetic White Un-Dyed Media 2. 10.0 Pleats Per Foot 3. Expanded Metal Pleat Supports 4. Moisture Resistant Beverage Board Frame 5. Double Wall Frame NOTES i. MERV B-A PerASHRAE 52.2-2007 Appendix J. 2. Final Resistance: 110"W.G. 3. Rated Velocitr. 600 FPM 4. Claw 2 Filter Per U.L. Standard 900 5. Maximum Operating Ternperatunx. 225 DE�G. F W, MODELNUMBER NOMINAL SIZE IN.WXHXD ACTUAL SIZE IN.W X HXD RATED AJRFLOW CFM INITIAL RESISTANCE IN.WG. MEDLAAREA 80. FT. MX40-STD2-217 I0X20X2 9-112 X 19-1/2 X 1-3/4 700 0.29 4.7 MX40-STD2-220 12X2OX2 I I A/2 X 19-1/2 X "14 840 0.29 5.5 MX40-STI)2-210 12X24X2 I I-W8 X 23.3ffl X 1-3/4 1000 0.29 6.2 MX40-STD2-239 14X20X2 13-1/2 X 19-1)2 X 1-3/4 980 0.29 5.7 MX40-21D2-241 14X25X2 13�W X 24-1 Q X "/4 1220 (129 7.1 MX40-STD2-245 15X20X2 14-112 X 1942 X "14 1050 0.29 62 MX40-STD2-201 16 X 20 X 2 15-1/2 X 19-112 X 1-3/4 1120 0.29 6.7 MX40-STD2-216 16X24X2 15-318 X 23-318 X 1-3/4 13,10 0.29 8.0 MX4G-STD2-202 16X24X2 16-112 X 24-1/2 X "14 1400 0.29 8.0 MX40-STD2-260 15X20X2 17-1/2 X 19-112 X "14 125D 0.29 7.8 MX40-STD2-212 I8X24X2 1 17-3/8 X 23-3/8 X "/4 1600 1 029 1 9.3 MX40-STD2-285 18X25X2 17-112 X 24-1/2 X 1-3/4 1570 0.29 9.7 MX40-ST02-203 20X2OX2 19�1/2 X 19-112 X 1-3/4 1400 0.29 8.3 MX40-STD2-211 20X24X2 19-M X 23-3/8 X 1-314 1670 0.29 9.9 MX4D-STD2-2G4 20X25X2 19-1/2 X 24-1/2 X "14 1750 0.29 10.3 MX40-STD2-205 24X24X2 23-M X 23-3ffl X 1-3/4 2000 0.29 11.7 MX40-STD2-225 25X25X2 24-1/2 X 24-1/2 X 1-3/4 2170 0.29 13.6 FLD = Furnished by Trane U. S. Inc, / Installed by Equipment Submittal Page 31 of 35 Others SLC - Admin AHU Repl June 28, 2018 Accessory - Performance Climate Changer Trap Schedule Item: Al, A2 Qty: 2 Tag(s): AHU-2, AHU-4 Drain pan trapping for section under negative pressure L = H + J + pipe diameter where: H = 1 inch for each inch of negative pressure (loaded filters) plus I inch J = J� H Drain pan trapping for section under positive pressure L = H + J + pipe diameter where: H = 112 inch (minimum) J = 3� inch plus the unit positive static pressure at coil discharge (loaded filters) Entering Discharge Recommended Trap Dimensions' E)d. Static Ext. Static Drain pan Selected Unit Unit Pressure Pressure Section H i L Baserail Tag(s) Size (in H20) (in H20) Location (in) (in) (in) Height (in)' AHU-22 Unit size 30 1.500 1.500 Coil sec on 4.584 2.292 7.876 6.000 121 AHU-42 Unit size 21 1.450 1.450 Coil section 4.421 2.211 7.632 6.000 121 I To ensure proper condensate trapping the field installed housekeeping pad height is the responsibility of the contractor. 2 The external static pressure used for fan selection was assumed to be divided 50% to entering duct external static pressure and 50% discharge external static pressure. Others SLC - Admin AHU Repi June 28, 2018 Accessory - Performance Climate Changer Filter Schedule Item: Al, A2 Qty: 2 Tag(s): AHU-2, AHU-4 Unit Unit Filter Filter Filter Filter MERV Filter Filter Tag( Size Location Arrangement Depth Type Ratinn Quantity Size AHU-2 Unit size 30 Air modng 2in. filterframe Pleated media MERV 8 18 16!n.x2Oin. section f1l -run set 6 16ln.x25jn. AHU-4 Unit size 21 Air mi)dng I 2in. filter frame Pleated media MERV 8 12 16in.x25!n. section 11] -run set FLD = Furnished by Thine U.S. Inc. linstalled by Equipment Submittal Page 33 of 35 Others MCA MOP Schedule Item: Al, A2 Qty: 2 Tag(s): AHU-2, AHU-4 Unit Tag(s) Circuit Circuit Description Voltage/ haselHz MCA (A) MOP (A) AHU-2 1, Supply fan 460/3/60 30.63 50.00 motor(s) AHU4 1 Supply fan 460/3/60 23.13 40.00 motor(s) FLD = Furnished by Trane U.S. Inc. /Installed by Equipment Submittal Page 34 of 35 Others SLC - Admin AHU Repi June 2B, 201B Field Installed Options - PartfOrder Number Summa!Y This is a report to help you locate field installed options that arrive at the jobsite. This report provides part or order numbers for each field installed option, and references it to a specific product tag. It is NOT intended as a bill of material for the job. Product Family - Performance Climate Changer Iltem ITag(s) —�Q I Description :�—_�Moclel Number IA1 JAHU-2 1 1 Perrormance Climate Changer (CSAA) ICSAA03OUA JA2 JAHU-4 11 1 Performance Climate Changer CSAA) I CSAA021 UA Field Installed O�tion Description I PartlOrder!nA Nu Pleated media - 1 set I FLD = Fumished by Tiane U.S. Inc. linstalled by Equipment Submittal Page 35 of 35 Others