EVALUATION REPORT
Polyglass USA, Inc. Evaluation Report P12060.02.09-1124
1112 West Newport Center Drive FL5259-R28
Deerfield Beach, Fl. 33442 Date of issuance: 02/24/2009
(954) 233-1230 Revision 24:01/24/2018
SCOPE:
This Evaluation Report Is issued under Rule 61620-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nleminen, P.E.
for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated foe compliance with the 6rh Edition (2017) Florida Building Code sections noted
herein.
DESCRIPTION: Polyglass Roof Underlayments;
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED ComPuANcE: This Evaluation Report Is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done In its entirety.
INSPEcTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for Inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages I through 14.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert Nlemlnen,
P.E. on 01/2412018. This does not senre as an electronically
signed document.
CER7111FICATION OF INDEPENDENCE
1. NEM01 etc. does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMOl etc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nlemlnen, P.E. does not have nor will acquire, a financial interest In any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither NEMO I etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
ONEMOjetc.
ROOFING COMPONENT EvALuATiON:
1. SCOPE:
Product Category, Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the
following sections of the Bth Edition (2017) Florida Building Code through testing in accordance with the following Standards.
Compliance is subjectto the Installation Requirements and Urnitations / Conditions of Use set forth herein.
2. STANDARDS.
Section
Property
Standard
Year
1504.3.1
Wind Uplift
FM "74
2011
1504.3.1
Wind Uplift
UL 1897
2012
1507.2.3/1507.1.1
Physical Properties
ASTM D226
2009
1507.2.4/1507.1,1,2507.2.9.2
Physical Properties
ASTM D1970
2015
1507.3.3
Physical Properties
FRSAITRI April 2012
2012
1507.11.2
Physical Properties
ASTM D6164
2011
2507.11.2
Physical Properties
ASTM D6222
2011
TAS11O
Accelerated Weathering
ASYM D4798
2011
3. REFERENCES:
i99W
Examination
Reference
Date
FM Approvals (TST 1867)
Wind Uplift
3004091
01/12/2000
PRI (TST 5878)
Physical Properties
PRI01111
04/08/2002
PRI (TST 5878)
Physical Properties
PUSA-005-02-01
01/31/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-M
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-02
12/23/2002
FRI (TST 5878)
Physical Properties
PUSA-013-02-03
12/23/2002
PRI (TST5878)
Physical Properties
PUSA-018-02-01
07/14/2003
PRI ITST 5878)
Physical Properties
PUSA-028-02-01
07/13/2005
PRI (TST 5878)
Physical Properties
PUSA-033-02-01
02/12/2006
PRI (TST 5878)
Physical Properties
PUSA-035-02-01
09/29/2006
PRI (TST 5878)
Physical Properties
PUSA-055-02-02
12/10/2007
PRI (TST 5978)
Physical Properties
PUSA-061-02-02
01/28/2008
PRI (TST 5878)
Physical Properties
PUSA-076-02-01
02/2212008
PRI (TSr 5878)
Physical Properties
PUSA-083-02-01
04/14/2008
PRI (TST 5878)
PhysIciii Properties
PUSA-088-02-01
07/29/2009
MTI (TST 2508)
Physical Properties
JX20H7A
04/01/2008
MTI (TST 2508)
Physical Properties
RX14EBA
01/29/2009
ERD OST 6049)
Physical Properties
11752.09.99-1
02/08/2000
ERD (TST 6049)
Wind Uplift
11757.08.01-1
08/13/2001
ERD CTST 6049)
Wind Uplift
11776.06.02
01/16/2003
ERD (TST 6049)
Physical Properties
02200,07.03
07/14/2003
ERD (TST 6049)
Wind Uplift
P1740.01.07
02/04/2007
ERD (TST 6049)
Physical Properties
P5110.04.07-1
04/11/2007
ERD (TST 6049)
Wind Uplift
P9260.03.08
03/22/2008
ERD (TST 6049)
Physical Properties
P13450.08.09
08/13/2009
ERD M 6049)
Wind Uplift
P30540.11.09-RI
11/30/2009
ERD (TST 6049)
Physical Properties
P11030.11.09-1
11/30/2009
ERD (TST 6049)
Wind Uplift
P11030.21.09-2
11/30/2009
ERD (TST 6049)
Physical Properties
P11030.11.09-3
11/30/2009
ERD (TST 6049)
Physical Properties
P33360.06.10
06/25/2010
ERD (TST 6049)
Physical Properties
P33370.03.11
03/02/2011
ERD (TST 6049)
Physical Properties
P33370.04.11
04/26/2011
ERD (TST 6049)
Physical Properties
P37300.20.21
10/19/2011
NEMO ETC, LLC.
Evaluation Report P12060.02.09-R24
Cedii%wte VfAutha�Von 032455
0 EDITION (ZO17) FEIC NON-HVHZ EVALUATION
FL5259-RZB
Revision 24:01/24/2018
Polyglass Roof Underlayments;
(954) 233-1230
Page 2 of 14
4.
ONEMOletc.
gntty
Examination
Reference
Date
ERD (TST6049)
Physical Properties
1340390 08 12-1
08/06/2012
ERD (TST 6G49)
Physical Properties
P40390.08.12-2
08/07/2012
ERD (TST 6049)
Physical Properties
C41420.09.12-3
09/11/2012
ERD (TST 6049)
Wind Uplift
P39680.03.13
03/04/2013
ERD (TST 6049)
Physical Properties
P45370.04.13
04/26/2013
ERD (TST 6049)
Wind Uplift
P1738.02.07-R2
04/29/2013
ERD (TST 6049)
Wind Uplift
11757.04.01-1-RI
04/30/2013
ERD W 6049)
Wind Uplift
P41630.08.13
08106/2013
ERD CrST 6049)
VLFInd Uplift
P11751.05.03-RI
11/26/2013
ERD (TST 6049)
Wind Uplift
P12781.11.03-RI
11/26/2013
ERD (TST 6049)
Physical Properties
P45270.05.24
05/12/2014
ERD (TST 6049)
Physical Properties
6020.07.14-1
09/CS/2014
ERD DST 6049)
Physical Properties
6020.09.14-2
09/08/2014
ERD W 6049)
Physical Properties
6020.09.14-3
09/08/2014
ERD (TST 6049)
Physical Properties
6020.09.14-4
09/08/2014
ERD (TST 6049)
Physical Properties
6020.09.14-5
09/08/2014
ERD W 6049)
Physical Properties
6020.09.14-6
09/08/2014
ERD M 6049)
Physical Properties
P46520.10.14
10/03/2014
ERD 0 S7 6049)
Physical Properties
P43290.10.14
10/17/2014
ERD ITST6049)
Physical Properties
PLYG-SC7550.03.15
03/24/2015
ERD ITST 6049)
Physical Properties
P40390.04.25
04/03/2015
ERD W 6049)
Physical Properties
P44360.20.24-RI
05/18/2015
ERD (TST6049)
Physical Properties
PLYG-SCSOBB.05.15-1
05/20/2015
ERD M 6049)
Wind Uplift
PLYG-SCS905.05.16-1
05/17/2016
ERD (TST 6049)
Physical Properties
PLYG-SC8080.07.16
07/16/2016
EIRD (TST 6049)
Wind Uplift
PLYG-SC12025.10.16
10/22/2016
ERD M 6049)
Physical Properties
PLYG-SC13040.12.16
22/27/2016
ERD M7 6049)
Physical Properties
PLYC3-SCII900.03.17
03/10/2017
ERD CFST 6049)
Physical Properties
PLYG-SC12115.08.17
08/08/2017
[CC -ES (EVIL 2395)
IBCCompliance
ESR-1697
11/01/2014
Miami -Dade (CER 1592)
HVHZCompllance
NOA 14-0717.08
01/22/2015
Polyglass USA
Manufacturing Affidavit
Products Current
02/18/2009
Polyglass USA
P/1-Afficlavit
Mule -Hide Cross Ltg
03/01/2008
Polyglass USA
Materials Affidavit
Polystick SA Compound
08/18/2011
UL, I.I.C. (QUA9625)
Quality Control
Service Confirmation
Exp. 10/05/2018
PROIDucr DEscitwrlom
4.1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet.
4.1.2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet.
4.1.3 Polyglass G2 Base is a fiberglass -reinforced, asphaltic base sheet.
4.1.4 Polyglass APP Base is a fiberglass -reinforced, APP modified bitumen base sheet.
4.2.1 Polystick IVITS or Polystick MITS PLUS is a nominal 60-mil thick rubberized asphalt
fiber reinforced, surfaced with polyolefinic film surface; meets FRSA/TRI April 2012.
glass
4.2.2 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an
aggregate surface; meets ASTM D1970.
4.2.3 Polystick TU Plus Is a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, wifth a
polyester fabric surface; meets ASTM D1970 and FRS"I April 2012.
NEMO ETC, LLC Evaluation Report P12060.02.09-R24
CeWftwu, cfAutho�tlan A32455 e EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R28
Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018
Page 3 of 14
ONEMOletc.
4.2.4 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester
reinforced, with a granular surface; meets FRSA/TRI April 2012.
4.2.5 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/m' polyester
ftbricsurface; meets ASTM D1970 and FRSA/rRI April 2012.
4.2.6 Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) are polyester
reinforced, APP modified bitumen cap sheets; meet FRSAITRI April 2012.
4.2.7 Polystick Dual Prom Is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyester fabric surface; meets ASTIVI D1970.
4.2.8 Polystick Tile Prom Is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyester fabric surface; meets ASTM D1970 and FRSA/rR1 April 2012.
4.2.9 Polystick MU-X is a nominal 54-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polypropylene film surface; meets AC188 and physical requirements of ASTM D1970 (See Section
5.8).
_77
4.3.1 Elastofiex 6 TU Is a polyester reinforced, modified bitumen tile underlayment composed of a sand -surfaced SBS
modified bitumen back-slde and granule -surfaced APP modified bitumen top -side. Elastaflex G TU Is for use as an
alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April
2012 (04-12) beneath mechanically fastened tile roof systems or Hot Asphalt applied "Cap Sheet" in the 'Two Ply
System" from FRSA/rRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems.
4.3.2 Elastaflex S6 6 and Elastoflex S6 G FR are polyester reinforced, SBS modified bitumen cap sheets; meet ASTIVI D6164.
Elastaflex S6 G and Elastoflex S6 6 FRI are for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380,
Class M) in the "Single Ply System" from FRSAfFRI April 2012 (G4-12) beneath mechanically fastened tile roof systems.
Elastoflex: S6 G is for use as an alternate to Hot Asphalt applied "Cap Sheet" in the �rwo Ply System" from FRSA/TRI
April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Elastoflex S6 6 FR is for use as an
alternate to Hot Asphalt applied "Cap Sheet" in the "I"wo Ply System" from FRSA/TRI April 2012 (04-12) beneath
mechanically fastened tile roof systems.
4.3.3 Polyflex G and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets; meet ASTIVI D6222.
Polyflex G is for use as an alternate to Heat Applied "Cap Sheet" in the —rwo Ply System" from FRSA/rRI April 2012
(04-12) beneath mechanically fastened or adhered tile roof systems. Polyflex G FR is for use as an alternate to Heat
Applied wCap Sheet" in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile
roof systems.
S. LimmAriciNs:
5.1 This is a building code evaluation. Neither NEMO]etc. nor Robert Nleminen, P.E. are, In any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use In the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product Is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
NEIVID M LLC. Evaluation Report P12060.02.09-R24
Gutiflote ofAuthor&otlan #324SS EV1110N (2017) FBC NON-HVHZ EVALUA'nON FL5259-RZB
Polyglass Roof Underlayments; 1954) 233-1230 RevIslon 24:02/24/2018
Page 4 of 24
ONEMOjetc.
5.5 Allowable Roof Covers:
Underlayment
Asphalt Shingles
Nall -On Tile
Foam -on Tile
Metal
Wood Shakes
Slate
& Shingles
Elastobase
Yes
Yes
Yes
Yes
Yes
Yes
(�aS�atla2-plyWuern)
(Sa.Sh.etJn2-PlyWna.)
Elastobase P
Yes
Yes
Yes
Yes
Yes
Yes
(Haa.sh.atlaZ-p1yWAera)
(BamShaat1n2-plyW�aa)
Polyglass G2 Base
No
Yes
Yes
No
No
No
(Basafteatin2-plyWAcra)
(Bs=Shealln2-p�ya,�rn)
PolyglassAPP Base
No
Yes
Yes
No
No
No
(BascStmetln2-ply��aa)
(Sam Shealin2-plysynera)
Polyslick NITS or MTS PLUS
Yes
Yes
No
Yes
Yes
Yes
Polystick IR-Xe
Yes
No
No
No
Yes
Yes
PolystickTU P
No
Yes
Yes (See 5.5.1)
No
No
No
PolystickTU Plus
Yes
Yes
Yes (See 5.5.1)
Yes
Yes
Yes
Polystick TU Max
No
Yes
Yes (See 5.5.1)
Yes
No
No
Polystlick Dual Pro
Yes
No
No
Yes
Yes
Yes
Polystick Tile Pro
Yes
Yes
Yes (Sees.5.1)
Yes
Yes
Yes
Polystick MU-X
Yes
No
No
Yes
Yes
Yes
Elastoflex S6 G
Yes
Yes
Yes (SeeS.5.2)
No
Yes
Yes
ElastoflexS6 G FR
Yes
Yes
No
No
Yes
Yes
Elastollex G TU
Yes
Yes
Yes (See S.5.1)
No
Yes
Yes
Polyflex 6
Yes
Yes
Yes (See 5-9.1)
No
Yes
Yes
Polyflex G FR
Yes
Yes
No
No
Yes
Yes
Polyflex SAP or SAP FR
Yes
Yes
Yes (SeeS.5.11
No
Yes
Yes
Mule -Hide SA-APP Ca p Sheet
Yes
Yes
Yes (See S.S.1)
No
Yes
Yes
orSA-APP Cap Sheet (FRI
5.5.1 "Foam -On Tile is limited to use of the following Approved He adhesives / underlayment combinations.
-.-1 .1 A
I- . I-
AUjDwJW T16
R,
Adhesive
Florida Product
Underlayments
Approval
DAP Foam Touch 'n S�l StornnEond Roof
FL14506
Polystick TU Plus, PolystickTU Max
TileAdhesive
Dow TileBond-
FL22525
Polyst"Ick TU P, Polystick TU Plus, Polyflex SAP orTile Pro
PolystickTU P, Polystick TU Plus, Polystick TU Max, Polystick'nle Pro,
ICP Adhesives PolysetO AH-16D
FL6332
Elastoflex G TU, ElaMffex S6 G, Polyflex 6, Polyflex SAP, Polyflex SA Cap FR,
Mule -Hide SA-APP Cap Sheet or Mule-Hicle SA-APP Cap Sheet (FR)
Polystick TU P, Polystick TU Plus, Polystllck TU Max, Polystick Tile Pro
ICP Adhesives PolysetO RTA-1
FL6276
Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA &p FR,
M ule-Hide SA -AP P Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR)
2 Refer to Tile Manufacturer's of Adhesive Manufacturer's Florida Product Approvalfor overturning Moment Resistance Performance.
NEMO ETC, U.C. Evaluation Report P12060.02.09-R24
Cerfffl� SfAuthadaath. #32455 r EDITION (2017) FBC NON-HVHZ EVALUATION FL525"28
Polyglass Roof Underlayments; (954) 233-U30 Revision 24:01/2412018
Page 5 of 14
ONEmo I etc.
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck:
Polystick (all variations), Dual Pro,'I'lle Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet
(FR) self -adhered to:
> New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTIVI D41 primed existing
plywood; New or existing, unprimed OSB; ASTM D41 primed CSB; Southern Yellow Pine; ASTM D41 primed
Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIP System" Panels
(designed and installed to meet wind loads for project).
Note." Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or
OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes.
Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to;
> ASTIVI D41 primed structural concrete.
Polyflex G or Polyflex G FR torch -applied to:
> AST M D41 primed structural concrete.
5.6.2 Bond -to -insulation;
Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered
to:
> ASTIVI C1289, Type 11, Class 1 polyisocVanu rate or Type V polyisoclianurate-composite Insulation; Dens Deck
DuraGuard; Dens Deck Prime; or SECUROCK Gypsum -Fiber Roof Board.
Elastoflex G TILI, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
> Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board.
Polyflex G or Polyflex G FR torch -applied to:
> ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum-Flber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile
systems, Insulation attachment shall be designed by a qualified design professional and Installed based an testing of
the insulation/underlayment system In accordance with FBC Section 1504.3.2.
5.6.3 Bond to Mechanically Attached Base Laver
Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or
Tile Pro self -adhered to:
> ASTM D226, Type I or 11 felt; Elastobase; Elastobase P or Mule -Hide Nall Base.
Elastoflex G TILI, Elastoflex S6 G or Elastoflex S6 G FR In hot asphalt to:
> ASTM D226, Type I or 11 felt; Elastobase; Elastabase P, Mule -Hide Nall Base or Polyglass G2 Base.
Polyflex G or Polyflex G FR torch -applied to:
> Elastobase; Elastobase P, Mule -Hide Nail Base, Polyglass G2 Base or Polyglass APP Base.
For Installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam -on tile systems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, Or as listed in Section 5.6.4 herein, or as tested In
accordance with FBC Section 1504.3.1.
NEMO ETC, LUC. Evaluation Report P12060.02.09-1124
Oeff,foXe VfAutha.�. 932455 E�H EDITION (2017) Flat NON-HVHZ EVALUATION FL5259-RZB
Polyglm Roof Underlayments, (9541233-1230 Rmision 24:01/24/2018
Page 6 of 14
ONEMOletc.
5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRl April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam -an tile systems, where the underlayment
forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA(TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the
result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure
divided by 2 (the 2 to I margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-
12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads.
#1 Maximum Design Pressure= -90 ;
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: None
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polysfick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule-Hicle SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), selfachered.
#2 Maximum Design Pre sure = -97.5 psf.*
Deck; Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional) Polystick WS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back-nalled within the selvedge -edge side laps using 12 ga. x
1Y" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch O.C.
#3 Maximum Design Pre ure=-205psf.,
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer; WB-3000
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, P13lyf1aK SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x
IX" ring shank nails through 32 ga., 1-5/8' diameter tin caps spaced 12-inch o.c.
#4 Maximum Design Pressure = -135 P
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional) PG100 or ASTM D41
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Joints: Min. 4-inch wide strips of Elastoflex SA-V over all plywood joints.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#5 Maximum Design Pressure = -315 p
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional) Polystick MIS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TIJ P, Polystick TU Plus, Polystick TU Max, 'File Pro, Polyflex SAP, Polyflm SAP FR, Mule -Hide SA-APP Cap
Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#6 Maximum Design Pressur��:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASrM D41
Underlayment: ElastoflexGTU or ElastoflexS6 G, applied in full mopping of hot asphalt or PolyflexG,tomh-applied.
#7 Maximum Design Pressure = -30.0 psf*:
Deck: Min. 15/32-inch OSB to meet project requirements to satisfaction of Authoflty Having.lurisdiction.
Base Sheet: Elastobase or Mule-Hicle Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.254nch long x I -Inch head diameter round metal cap nails
Spacing: 64nch o.c. at the 3minch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) PoWick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule-Hicle SA-APP Cap Sheet (FR), self -adhered.
NEMO ETC, LLC. Evaluation Report P12060.02.09-R24
Cero7wo, cfAutho�tlon 032455 e" EDITION (20171 FEIC NON-HVHZ EVALUATION FLS259-R28
Polyglass Roof Underlayments; (SIS41233-2230 Revision 24:01/24/2018
Page 7 of 14
ONEMOletc.
#8 Maximum Design Pressure = -37.5 i3sf*:
Deck: Min. 15/324nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nall Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch longx 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. atthe 3-inch wide side laps and 6-Inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS or Polystick MTS PWS, self -adhered.
Underlayment: PolystickTU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FIR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#9 Maximum Design Pressure = -37.5 psf*
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: one (1) or two (2) layers ASTM D226, Type 11 felt
Fasteners: 11 ga. x 1.254nch long x 1-inch head diameter round metal cap nails
Spacing: 6-Inch ci.� at the 3-Inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt
#10 Maximum Design Pressure = -45 psf*:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (1) layer ASTM D226, Type 11 felt
Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c. at the 2-Inch wide side laps and 44nch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional; for use with self -ad hering underlayment only) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FIR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered or Elastoflex G TU, applied in full mopping of hot asphalt.
#11 Maximum Design Pressure = -45 psf*:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Two (2) layers ASTM D226, Type It felt
Fasteners: 11 ga. x 1.25-Inch long x 3/8-Inch head diameter annular ring shank roofing nails at I-S/8-Inch diametertinceps
Spacing: 9-Inch o.c. at the 2-inch wide side laps and 9-Inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MIS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, PclysflckTU Plus, Ficilystick TU Max, Polyflex SAP, Polyflex SAP FRI, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cup Sheet (FR), self -adhered or Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot
asphalt.
#12 Maximum Design Pressure = -45 9)
Deck; Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top Surface for hot�sphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c. at the 2-inch wide side laps and 18-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastaflex G TU or Elastoflex 56 G, applied in full mapping of hot asphalt or Polyflex 6, torch -applied.
#13 Maximum Design Pressure = -52.5 p
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-Inch o.Q at the 2-Inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastaflex S6 6, applied In full mopping of hot asphalt or Polyflex 6, torch -applied.
#14 Maximum Design Pressure -- --52.5-Psf
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nall Base (poly -film top surface)
Fasteners; Simplex Original Cap Nails
Spacing: 6-inch o.c. atthe 3-inch wide Side laps and 6-Inch o.c. at four (4) equally spaced staggered center rows.
Base Ply; (Optional) Polystick MTS or Polystick NITS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FRI, Mule -Hide SA-APP Cap Sheet and
Mule�Hlcle SA-APP Cap Sheet (FR), seif-adhered.
NEMO ETC, I.I.C. Evaluation Report P12060.02.09-R24
CertWaimcfAutha�Van #32455 EDITION (2017) F13C NON-HVHZ EVALUATION FLSZS9-RU
Polyglass Roof Under[aVments; (954) 233-2230 Revision 24:01/24/2018
Page 8 of 14
ONEMOletc.
#15 Maximum Design Pressure � -52.5
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c at the 3-inch wide side laps and 6-Inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflu G TU or Elastoflioi S6 G, applied in full mopping of hot asphalt or Polyn" G, torch -applied,
#16 Maximum Design Pressure = -60 p
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: 11 ga. x 1.25-Inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 84rich o.c. at the 4-Inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mapping of hot asphalt or Polyflex G, torch -applied.
#17 Maximum Design Pressure = -60 13
Deck: Min. 19/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt ortorch-applied cap or poly -film surface for torch -applied cap)
Fasteners: 0MG #12 Standard Roofgrip with OMG Flat Bottom Metal Plates
Spacing: 12-Inch o.c. at the 4-inch wide side laps and 12-Inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mapping of hot asphalt or Palyfleii G, torch -applied.
#18 Maximum Design Pressure = -67.5 p
Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment)
Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c. at the 44nch wide side laps and 8-Inch ox. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex SIS G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -
applied.
#19 Maximum Design Pressure = -75 p
Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requines use of torch -applied underlayment)
Fasteners: Dekfast #14 with Dekfast H� plates, OMG #14 HD with OMG 3' Galvalume Steel Plates, OMG Roofgrip #14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trubst 3-inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing; 10,4nch o.c. at the 4-Inch wide side laps and 10-Inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflu G TU or Elastoflex S6 G, applied In full mapping of hot asphalt or torch -applied or Polyflex G, torch -
applied.
#20 Maximum Design Pressure= -90 P
Deck; Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simpl" MAXX Cap Fasteners
Spacing: &Inch o.c. at the 2-Inch wide side laps and 64nch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflu G TU or Elastoflm S6 G, applied in full mopping of hot asphalt or Polyflex 6, torch -applied.
#21 Maximum Design Pressure = -90 P
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having.luriscliction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG 022 Standard Roofgtip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing: 6-Inch o.c. at the 4-inch wide side laps and 6-Inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastcifi" G TU or Elastoflex S6 G, applied in full mapping of hot asphalt or Polyffm G, torch -applied.
#22 Maximum Design Pressure = -90 p
Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having.luriscliCtlDn.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates
Spacing: 6-Inch o.r— at the 4-inch wide side laps and 64nch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elast0fl" SIS G, applied In full mapping of hot asphalt
NEMO ETC, LLC. Evaluation Report P12060.02.09-R24
fAvfhcmzd.. #M455 GP EDIMON (20171 FBC NON-HVHZ EVALUA110N FLS259.R28
Polyglais Root Underlayments; (954) 233-1230 Revision 24: 02/24/2018
Page 9 of 24
ONEMOletc.
#23 MaAmurn Design Pressure= -90 p
Deck: Min. 15/32-inch plywood to meet project req ul rements to satisfaction of Authority Having Jurisdictl on.
Base Sheet: Polyglass G2 Base or Polyglass APP Base frequires use of torch -applied underloyment)
Fasteners: Deklast #14 with Deklast Heic plates, OMG #14 HD with OMG 3" Galvalume Steel Plates� OMG Roofgrip #14 with
CMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: SlAnch o.c. at the 44nch wide side laps and 9-inch o.c. atfour (4) equally spaced staggered center rows.
Underlayment: Elastaflex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt or torch�appllecl or Polyfleir G, torch -
applied.
#24 Maximum Design Pressure = -97.5 p
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/84rich diameter tin caps
Spacing: 4�inch o.c. at the 4-Inch wide side laps and 4-Inch o.c. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polynex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
$125 Ma)dmum Des[Rn Pressure= -105 P
Deck:
Min. 3.5/32-inch plywood to meet project requirements to satisfaction of Authority Having.lurlsdictlon.
Base Sheet:
Elastabase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners:
Simplex MAXX Cap Fasteners
Spacing:
64nch o.c. at the 2-Inch Wide side laps and 64nch o.c. atthree (3) equally spaced staggered center rows.
Underlayment;
Elastoflex G TU or Elastoflm 56 G, applied In full mopping of hot asphalt or Polyflex G, turch�pplied.
#26 Maximum Design Pressure = -112.5 ps
Deck:
Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners:
11 ga. x 1.254rich x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diametertincaps
Spacing:
6-Inch o.c. at the 4-inch Wide side laps and 6-Inch o.c. at four (4) equally spaced staggered center rows.
Primer:
PGIOO or ASTM D41 primer at all tin -caps
Base Ply:
Polystick M7S or Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, PolystickTU Plus, Polystick TU Max, Polyff" SAP, PolyflexSAP FR, Mule -Hide SA-APP Cap Sheet and
Mule-Hicle SA-APP Cap Sheet (FIR), self -adhered.
#27 Maximum Design Pressure = -120 p :
Deck:
Min. 15/324nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase (sanded top surface for hot-aspbalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners:
CMG #12 Standard Roolgrip, or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or CIMG Flat Bottom Metal
Plates
Spacing:
6-inch o.c. at the 4-inch wide side laps and 6-Inch o.c. at five (5) equally spaced staggered center rows.
Underlayment: Elastaflex � TU or Elastaflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#28 MeAmunn .. n Pressure = -120 DO;
Deck; Min. 35132-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast #12 DIP or Trufast #14 HID with Trufast 3" Metal Insulation Plates
Spacing: 6-inch mc at the 4-Inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S5 G, applied in full mopping of hot asphalt.
5.15A.1 All other direct -deck, adhered Polyglass underlayment systems beneath foam -on file systems carry a MaAmunn
Design Pressure of -45 psf.
NEMID ETCi LUC. Evaluation Report P12060.02.09-R24
Geraftxv� of Auftfizinion #M455 EDITION (2017) FBC NON.HVHZ EvALuA'm3N FLS259.Rza
Polyglass Roof Underlayments; (954) 233-V30 Rmlslon 24: 01/24/2018
Page 10 of 14
ONEMOjetc.
5.6.4.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed
that required under FRSAITRI April 2012 (04-12), Appendix A, Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone I design
pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density
designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are
ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked
with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January
2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30-days
after instal lation.
Polystick IR-Xe or Polystick MU-X shall not be left exposed for langerthan 90-days after installation.
Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max� Qual Pro, Tile Pro or Elastoflex G TU shall not be left exposed for
longerthan 180-days after installation.
Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure
limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure is 30
days.
Elastaflex SIS G or Elastoflex SIS G FR or Polyflex: G or Polyfiex G FR does not have an exposure limitation, unless the
prepared roof covering is to he adhesive -set tile (Elastoflex S6 G or Polyflex 6 only), in which case the maximum
exposure is 180 days.
5�8 Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226
roofing felt in a dry condlitlon, tested at standard laboratory conditions. Agreement between purchaser and seller, as
set forth in Section 4.3, Note I of ASTM D1970-25, should be established as to slip resistance.
5.9 Tile Slippage Limitations IFRSA/TRI April 2012 (04-12)):
When loading roof tiles on the underlayment In direct -deck tile assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
EINI
R'R §RpAq I M
oft,911
Underlayment
Tile Profile
Staging Method
Maximum Slope
Elastoflex G TU
Flat
10-tile stack
7:12
Lugged
8-tile stack (6 over 2)
6:12
Elastoflex S6 G or SG G FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polystick MTS or NITS PLLIS
Flat
6-tile stack (4 over 2)
5:12
Lugged
6-tile stack (4 over 2)
4:12
Polystick Tile Pro
Flat or Lugged
6-tile stack (4 over 2)
7:12
PolystickTU Max
Flat
6-tile stack (4 over 2) or 10-tile stack
7:12
Lugged
6.Ule stack (4 over 2)
7:12
Lugged
Mtile stack
6:12
PolystickTIJ P
Flat
6-tile stack (4 over 2)
6:12
Lugged
6-tile stack (4 over 2)
4:12
PolystickTU Plus
Flat or Lugged
&tile stack (4 over 2)
7:12
Flat or Lugged
10-tile stack
6:12
Polyflex G or G FR
Flat or Lugged
st L4 �jve�
E a�
4:22
Flat or Lugged
( v;r
15,tte st-2k 4 2))
4:12
NENIO ETC, LLC. Evaluation Repart P12060.02.09-1124
Geowtv ofAulhar&QUon #32455 EDITION (2027) FEIC NON-HVHZ EVALUATION FIL525941211
Potiffilan Roof Underlayments, (954) Z33-1230 RftIsIon 24: 01/24/2018
Page 11 of 14
I
6. WsTALLA'nom
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements
subject to the Ulmitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application, and prime the substrate (if applicable).
6.3.1 Non -Tile Applications:
Shall be installed In compliance with the codified requirements for ASTM D226, Type 11 undeflayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA
P FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered, Elastaflex G TU, Elastaflex SIS 6 or
Elastoflex S6 6 FR In hot asphalt or Polyflex 6 or Polyflex 6 FR, torch applied. Roof cover limitations are those are
those associated with the top -layer underlayment, as set forth in Table 2.
6.3.2 Tile Applications:
-Elastobase, Elastobase P or Mule -Hide Nail Base are limited to use as a mechanically allached base sheet in the "Two
Ply System" from FRSA/TRI April 2012 (04-1Z). Reference is made to Table I and Section 5.6.4 herein, coupled with
FRSA/TRI April 2012 (04-12) Installation Manual.
6.4.1 Shall be installed In compliance with the codified requirements for ASTM D1970 (except Polystick TU P) underlayment
6.4.2
in FBC Table 1507.1.1 for the type of prepared roof covering to be installed.
Direct -to -Deck with Mechanically Fastened Roof Covers:
All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA-APP
Cap Sheet orSA-APP Cap Sheet (FR) should be back -nailed in selvage edge seam in accordance with Polyglass / Mule -
Hide back nailing guidelines. Nails shall be corrosion resistant, 22 gauge ring -shank type with a minimum 14nch
diameter metal disk or Simplex-tVpe metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back -
nailed using the above noted fasteners and spacing, in area marked "nail area, area pare clavar' on the face of
membrane. The head lap membrane is to cover the area being back -nailed.
All seal -lap seams (selvage laps) must be
firmly rolled with a minimum 28 ib. hand
roller to ensure full contact and adhesion. r
For Dual Pro and Tile Pro, align the edge of
the top sheet to the end of the glue pattern
(the sheet will overlap the fabric).
View of ovelap Seam of Dwi Pro and Tile Pro
All over -fabric and over -granule end -laps shall have a 6-Inch wide, uniform layer of Polyplus So Premium Modified
Wet/Dry Cement or Polyglass PGSOO Modified Cement applied in between the application of the lap.
Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys,
or exposed roof to wall details
NEMOETC,LLC Evaluation Report P12060.02.0"24
Ceroftm� ofAuthorizatim #32455 157"IEDITION 12017) FBC NON-HVHZ EVALUATION FLS259-RZB
Polyglass Roof Underlaymenis; 19541233-1230 Revision 24; 01/24/2018
Page 12 of 14
ONEMOjetc.
Repair of Polysfick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or
Polyglass PGSOO Modified Cement to the area in need of repair, followed by a minimum 6 x 6 Inch patch of the
PolyWck material of like kind, set and hand rolled in place over the repair area. Patch laps, If needed, shall be
Installed in a water shedding manner.
AN Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a
minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied
for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min. 28 111 roller) or small areas of the
roof that are not accessible to a large roller or broom.
6.4.3 Tile Applications (not allowed for Polystick Dual Pro, iR-Xe orPolystick MU-X):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table I herein, using the instructions
noted above as a guideline.
For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base
Sheet fastening shall be not less than FRSA/TRl April 2012 (04-12), Table 2.
For adhesive -set tile applications, refer to Section 5.6.4 herein.
6.4.4 Two (2) Ply Underlayment Systems:
Polystick MTS or MTS PWS followed by Polystick MTS, MTS PLUIS, TLI P, TU Plus, TU Max, Tile Pro, MU-X or Polyflex
SAP is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with
the top -layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired.
Po[Wick IVITS or IVITS PLIJS followed by Polystick TLI P, TU Plus, TLI Max, Tile Pro or Polyflex SAP is allowable for use
under foam -an tile systems. Limits of use are those associated with the top -layer material. This is not a requirement,
but is allowable if a 2-ply underlayment system is desired.
6.5.1 Elastoflex G TLI, Elastaflex SIS G or Elastoflex S6 G FR shall be installed in compliance with current Polyglass published
installation requirements. For use In tile applications:
Elastoflex G TLI is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) In the "Single
Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" in the `rwo Ply System" from FRSAITRI April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
v` Elastoflex S6 6 is for use as an alternate to 'Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply
System" from FRSA/TRl April 2012 (04-22) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet' in the "Two Ply System" from FR5A/TRl April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
v' Elastaflex S6 6 FIR is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the 'Single
Ply System" from FRSA/TRl April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" In the 'rwo Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile
roof systems.
6.S.2 For hot -asphalt -applications, Elastaftex G TU, Elastaflex S6 G or Elastoflex S6 G FR shall be fully asphalt -applied to the
substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end -laps minimum 6-Inch wide, off -set
minimum 3 feet from course to course. Side and end laps shall be fully adhered In a complete mopping of hot asphalt
with asphalt extending approximately 3/8-inch beyond the lap edge.
6.6.1 Polyflex G or Polyflex G FR shall be installed In compliance with current Polyglass published installation requirements.
For use In tile applications:
Polyflex G is for use as an alternate to the Heat Applied "Cap Sheet" in the `rwo Ply System" from FRSA/TRI April
2012 (04-12) beneath mechanically fastened or adhered tile roof systems (Base Sheet Limited per 5.6.3).
Polyflex IS FR is for use as an alternate to the Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRl
April 2022 (04-12) beneath mechanically fastened tile roof systems (Base Sheet Limited per 5.6.3).
NEMO ETC4 LLC. EwItzation Report P12060.02.09-R24
Cerilkerte DfAdho�ati=M,155 e EDITION 120171 FBC NON-KVHZ EVALUATION FL5259-RZB
Polysiass Roof underlayments; (M) 233-IZ30 Revision 24:01/24/2018
Page 13 of 14
ONEMOjetc.
6.6.2 Polyflex G or Polyflex G FR shall be fully torch -applied to the substrates noted in Section 5.6. Side laps shall be
minimum 3-inch and end -laps minimum 6-Inch wide, off -set minimum 3 feet from course to course. Side and end
laps shall be fully heat -welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap
edge.
6.7 Tile StaRing:
6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Referto
Table 2 herein, and Polyglass published requirements for tile staging.
6.7.2 Battens and/or Counter -battens, as required by the file manufacturer and FRSA/TIU April 2012 (04-12) must be used
on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or nall-
boards, to prevent tile sliding and/or damage to the underlayment during the loading process.
6.7.3 Polyglass specifies the minimum cure time after Installation of self -adhering membranes and before loading of
roofing tiles Is forty-eight (48) hours.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to property evaluate the installation of this product.
9. MANUFACrURING PLANTS:
Contact the noted CIA agency for information on product locations covered for F.A.C. 6IGZO-3 CIA requirements. The following
plants have qualified products under their respective physical properties specifications.
4[i fit , __-I,
"I
'I - .1 - I , - ? - - I e�� . .1 - "T
Fernley, NV, Hazleton, PA & Winter Haven, FIL
ASTM M70
Polystick MIJ-X
Hazleton, PA
M-D 3.3-0004
Elastoflu G TU
Hazleton, PA & Winter Haven, Fl.
ASTM D1970
Polystick JR-Xe
ASTM D1970 & FRSA(TRI April 2012
PoWckTU Plus
ASTIVI D1970 & FRSAtTRI April 203.2
PolystickTU Max
Tuscaloosa, AL
ASTM D4601, Type 11
Polyglass G2 Base
Winter Haven, FL
ASTIVI D226 (physicals)
Elastabase, Elastobase P
ASTM D6509
Polyglass APP Base
FRSA/TRI April 2012
Polystick MTS, Polystick MTS PLUS
FRSA/TRI April 2012
Polvstick TU P
FRSA/TRI April 2012
Polyflex SAP, Polyflex SA P Fit
ASTM D1970
Polystick Dual Pro
ASTM D2970 & FRSA/TRI April 2012
Polystick Tile Pro
ASTM D6164
Elastun� S6, Elastoflex S6 G FR
ASTM D6222
Polyfim G, Polyfleit G FR
9. QUALITY ASSURANCE ENTITY:
UL, LLC — QUA9625; (314) 578-3406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT -