Loading...
HomeMy WebLinkAboutENGINEERINGTexas Republic Signs # Columns: 1 ME Job: 42331 A Height: Varies Width: Varies Structural Variables and 100w Overall Height: 100'-0" Table of Contents Sean M. McFarland, NEW STRUCTURE Content: Page EXISTING SUPPORTS & FOOTINGS Design Loads ........................ I ULTIMATE LOADS Support Design ....................... 1-2 42 KSI STEEL PIPE General Notes ....................... 3 CabinetType: Structural Section: Number of Zones: Misc Miscellaneous ESteel Pipe - 42000psi 18 Sign Sections: Cabinet Wt. Weight Transition Zone Per Sq. Ft. (Y or N) 1 2 3 4 5 6 7 8 20 'w 70.6 #IFT y 221.6 #IFT 221.6 #/FT 221.6 #IFT 221.6 #IFT y 356.6 #IFT y 474.6 #/FT y 522.7 #IFT y 0 25 0 20 o 0 0 God 2017FBCGthEd.-- Wind Spee� 170 Wind Exposur� C Loads Per ASCE 7-1 C 41 C) L 0 A License: Florida - Top *Approx. Width Approx. Zone Elevation Height Width Pressure Force Weight 1 100.00 FT 20.33 FT 24.00 FT 68.47 PSF 33.41 K 11,193# 2 79.67 FT 2.00 FT 3.50 FT 28.74 PSF 0.20 K 443 # 3 77.67 FT 7.50 PT 30.00 FT 63.21 PSF 14.22 K 7,287 # 4 70.17 FT 2.00 FT 3.50 FT 27.83 PSF 0.19,K 443 # 5 68.17 FT 5.00 FT 20.00 FT 59.23 PSF 5.92 K 3,108 # 6 63.17 FT 25.17 FT 4.50 FT 27.17 PSF 3.08 K 8,975 # 7 38.00 FT 29.00 FT 5.00 FT 24.44 PSF 3.54 K 13,763 # 8 9.00 FT 9.00 FT 5.50 FT 20.21 PSF 1.00 K 4,704 # Total Wind Force 61 57 K 499179 SCANNED BY St. Lude COUnty cc, A 3 IM Texas Republic Signs Overall Height: 100'-0" Sean M. McFarland, W Kings Hwy ME Job: 42331 A Moments at Transitions: Zone Lateral Force 8 Mom. Arm 7 Mom. Arm 6 Mom. Arm 5 1 Mom. Arm Mom. Arm 1 33.41 K 89.84 FT 80.84 FT 51.84 FT 26.67 FT 10.17 FT 2 0.20 K 78.67 FT 69.67 FT 40.67 FT 15.50 FT 3 14.22 K 73.92 FT 64.92 FT 35.92 FT 10.75 FT 4 0.19 K 69.17 FT 60.17 FT 31.17 FT 6.00 FT 5 5 92 K 65.67 FT 56.67 FT 27.67 FT 2.50 FT 6 3.08 K 50.59 FT 41.59 FT 12.59 FT 7 3.54 K 23.50 FT 14.50 FT 81 1.00 K 4.50 FT 4,714.19 K-FT 4,164.56 K-FT 2,459 K-FT 1,063 K-FT 340 K-FT Section Properties: 2040.77 INA3 1802.84 INA3 1064.68 INA3 460.09 INA3 73.50 INA3 Structural Sections to be used: Zone Option Pipe (NEW) Dim. Wall t. Weight SXX dit Sxx Req'd 8 Pipe (NEW) 66.00 IN 0.750 IN 522.7 #/FT 2,331.56 INA3 88.00 2,040.77 INA3 7 Pipe (NEW) 60.00 IN 0.750 IN 474.6 #/FT 1,920.28 INA3 80.00 1,802.84 INA3 6 Pipe (NEW) 54.00 IN 0.625 IN 356.6 #IFT 1,299.85 INA3 86.40 1,064.68 INA3 5 Pipe (NEW) 42.00 IN 0.500 IN 221.6 #/FT 628.43 INA3 84.00 460.09 INA3 1 Pipe (NEW) 18.00 IN 0.375 IN 70.6 #fFT 84.24 1 NA3 48.00 73.50 INA3 (DENNY'S CABINET) Structure wall Size Thickness 1 66.00 IN 0.750 IN 1 60.00 IN 0.750 IN 1 64.00 IN 0.625 IN I - -42.00 IN 0.500 IN 1 18.00 IN 0.375 IN Texas Republic Signs Overall Height: 100'-0" Sean M. McFarland, ME Job: 42331 A Pier Footing (NEW) Pier Footing Design: Select the footing and soil type: d = A t 2 * (I + (I + (4.36 h) / A)AI/2)) Footing: I Round where A = (2.34 P) / (SI * b) Vert. Soil Bearing (psD* 11500 Lat. Soil Bearing (psf): 1150 Mmax = 4,714,188 #-FT Pmax (Lateral) = 61,670 # LSBP = 160 PCF S1 = 1,200 PCF X d d = 8.000 FT For use with Round Footing A = 15.01 FT A 2 h = 76.566 FT d = 43.681 FT USE: 8.00 FT. RND. X 44.25 FT DEEP PIER Soil Bearing Check: DI -max = 49,917 LES Area of Footing = 50.27 FTA2 Actural SBP = 993 PSF Allowable SBP 4,600 PSF (includes code allowed 20% increase for every foot of footing below 12" into natural grade.) 993 PSF < 4,50OPSF THEREFOREOK General Notes 1 Contractor shall verify all dimensions and conditions on job site 2 Structural steel pipe shall conform to ASTIVI A53 grade B type E or S, Fy--36 ksi min. 3 Structural steel tube shall conform to ASTM A500 grade B, Fy--46 ksi min. 4 Structural steel shapes and plates shall conform to ASTM A36. 5 Welding shall conform to AISC specs or local codes and performed by certified welder using arc process E70XX electrodes. 6 Isolate Aluminum from Steel 7 All bolt holes to be drilled or punched. 8 2500 psi (min) 28-day Concrete Compressive Strength 9 All electrical work to conform to the requirements of UL48 and section 600 of NEC. 10 UL and Data labels required 11 Sign to be a minimum of " horizontal & 12-ft vertical from high voltage wires. 12 If there is no stub pipe to be used in the top cabinet, the supporting member immediately below the stub pipe shown can be extended to the top of the uppermost cabinet. 13 All Pipe sizes shown are minimum sizes. Pipe with a larger diameter and/or greater Sx� may be substituted 14 All structural lengths required are approximations only. Actual length may vary slightly depending on sign cabinet conditions. Texas Republic Signs Overall Height: 25'-7" Sean M. McFarland, P # Columns: 2 IREVIEWED & REVISED DWG lContent: Page ME Job: 42331 B NEW CABINET Design Loads ......................... I MATCHYLATES Support Design ................ ...... 1-2 Height: Varies EXISTING SUPPORTS & FOOTINGS General Notes ...................... � 3 Width: Varies ULTIMATE LOADS Structural Variables and Code Loading Specifications Cabinet Type: Structural Section: Nur Sections: Miscellaneous Tube Steel - 46000psi Cabinet Wt. Weight ne Per Sq. Ft. Transition (Y or N) 1 2 3 4 5 6 7 8 20 1 � 39.4 #IFT 39.4 #IFT 39.4 #IFT 39.4 #1FT 1 Y Y 0 25 0 0 0 jo �,w 10 IVI Uccle: 2017 FBC Gth Ed. Wind Speed: 170 Wind Ex Wind Loads Per ASCET, 10 "A f-, I- A oa Z License: Florida - Top Elevation Height Approx. Width Width Pressure Force Approx. Weight 1 25.58 FT 4.33 FT 10.00 FT * 64.98 PSF 2.81 K 1,207 # 2 21.25 FT 2.50 FT 10.00 FT * 60.64 PSF 1.52 K 197 # 3 18.75 FT 3.75 FT 10.00 FT * 57.23 PSF 2.15 K 1,233 # 4 15.00 FT 16.00 FT 2.00 FT * 43.85 PSF 1.32 K 1,183 # Total Wind Force = 7.79 K 3,821 # OCT 13 2019 lent e Republic Signs Overall Height: 25'-7" Sean M. McFarland, P.E. J #622 Wind Speed 170 mph McFarland Engineering IlSign. F I y iars; 100 W Kings Hwy ME Job: 42331 B Moments at Transitions: Lateral 4 3 1 Zone Force Mom. Arm Mom. Arm Mom. Arm 1 2.81 K 23.42 FT 8.42 FT 2.17 FT 2 1.52 K 20.00 FT 5.00 FT 3 2.15 K 16.88 FT 1.88 FT 4 1.32 K 7.50 FT 142.29 K-FT 35.28 K-FT 6 K-FT Section Properties: 28.12 IN A 3 6.97 IN A 3 1.20 IN A 3 Structural Sections to be used: Tubes (VIF) Zone Option Dim. Wall t. Weight Sxx dit Sxx Req'd I Structure Tubes (VIF) 12.00 IN 0.250 IN 39 #IFT 41.45 INA3 48.00 28.12 INA3 Tubes (New) 12.00 IN 0.250 IN 39 #/FT 41.45 INA3 48.00 6.97 INA3 Tubes(New) 3.00 IN 0.250 IN 9 #/FT 1.97 INA3 12.00 1.20 INA3 Wall Size Thickness 12.00 IN 0.250 IN 12.00 IN 0.250 IN 3.00 IN 0,250 IN Date: 10/10/18 City, State: Ft. Pierce, FL SHEET: 3 OF 3 Client: Texas Republic Signs Overall Height: 25'-7" Sean M. McFarland, P.E. Sign: Flyinq J #622 Wind Speed 170 mph McFarland Engineerin 100 W Kings Hwy ME job: 42331 B Pier Footings (VIF) Pier Footing Design: Select the footing and soil type: d = A / 2 * (1 + (1 + (4.36 * h) / A)41/2)) Footing: Round where A=(2.34*P)l(S1*b) Vert. Soil Bearing (psq: 1500 Lat. Soil Bearing (psq., I Mmax = Pmax (Lateral) = LSBP = S1 = d= A h d USE: Soil Bearing Check: Dl-max = Area of Footing = Actural SBP = Allowable SBP = Matchplate Design - D = 12.00 IN a = -1.00 IN b = 12.00 IN d = 12.00 IN plate t = 0.63 IN 71,144 #-FT 3,896 # 150 PCF 960 PCIF X d 3.000 FT 3.17 FTA 2 18.262 FT 9.677 FT 3.00 FT. RND. X 10.00 FT DEEP PIERS 3,821 LBS 7.07 FTA2 641 PSF 2,700 PSF (Includes code allowed 20% increase for every foot of footing below 12" into natural grade.) 641 PSF < 2,700 PSF THEREFORE OK A36 Steel Fy= 36ksi E70 Electrodes Fw-- 928 #/in/16th A307 A.B.'s Ft=20 ksi # of Bolts = 4 Dia. Bolt 0.625 Column Mom = 6,092 #-FT P Bolt= M * 12 (in/ft) 2 bolts (D + e + Q t req'd [(6*P*e*2 bolts)/(.75 * Fy (D+2*t))] A1/2 Weld M * 12 (in/ft) Fw (b*d + D A 2/3) 3,144 # < 6,100 # .325 IN , < 0.63 IN 0.41 16th's < 3.00 16th's USE: (4) 5/8" Die. Bolts wl 518" Matchplate. Weld to Support with (1) 3/16" Fillet Welds