HomeMy WebLinkAboutDOOR REPLACEMENT PLANf - ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR COMPLIANCZ DATE MUST BE KEPT ON JOE NO INSPECTION WILL BE THESE PLANS AND ALL PROPOSED WQRI-'% ARE SUBJECT TO ANY CORAM IONS REQUIRED BY MW IN19PE-CTORS THAT L14Y BE NECESSARY IN ORDER TO COMPLYWITH ALL APPLICAME CODES. CONCEALED FASTENERS OR A17ACHMENTS ARE THE RESPONSIBILMY OF THE CONTRACTOR OF RECORD DO Will Oil yj A a I PLACE DOOR IN I OPENING ONLY.. W DOOR TO BE IMPACT RESISTANT- RRICANE SHUTTERS NOT REQUIRED OPENING PRODUCT DESIGN OPENING SQ.. I WIND I PRESSURES APPROVAL PRESSURES I COMMENTS NO. WDTH. HGT. FTG ZONE POS. NEG. (N.O.A. #) POS. NEG. 36 1 80 20.01 4 54.5 1 -55.1 FI-16708.1 65.0 1 -65.0 FRONT ENTRY - LSMI REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS. NOCHANGEINSIZE. NO MODIFICATION TO OPENINGS. ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 1/41, TAPCON SCREWS INTO CONCRETE WITH A MINIMUM 1 1/4" PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS. LESS THAN 30% OF STRUCTURE'S VALUE. NOT A RENOVATED BUILDING. EXEMPT FROM 2017 ENERGY CONSERVATION CODE. SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES MEAN ROOF HEIGHT= 71 FT 6 IN ALBANESE CONDO UNIT 5151 N. HIGHWAY AlA, UNIT 81 1-A FORT PIERCE, FLORIDA DOOR REPLACEMENT PLAN