Loading...
HomeMy WebLinkAboutPRODUCT EVALUATION REPORT398 East Dania Beach Blvd. BUILDING DROPS Suite 338 A Perfect Solution in Every Drop I Dania Beach, FL 33004 954.399�8478 PH Certificate of Authorization: 29578 954.744.4738 FX contact@buildingdrops.com ProdtXtk Evaluation Report Of JELD-WEN, inc. Design Pro / Smooth Pro If Studio Fiberglass Impact Approved Opaque Doors For use in the High Velocity Hurricane Zone (HVHZ) for Florida Product Approval SCANNED BY R-Ienoril. No� 4663.1 St. Lucie County Current Florida Building Code Method: I - D (Engineering Evaluation) Category: Exterior Doors Sub - Category: Swinging Exterior Door Assemblies Product: Design Pro /Smooth Pro /Studio Fiberglass Impact Approved Opaque Doors For use in the High Velocity Hurricane Zone Material: Fiberglass Product Dimensions: XmO" X 6'-S" (Nominal) 3�-O"X 8'mO" (Nominal) Prepared For: it' W-WEN, inc� 3737 Lak-port BIV6, flainath Fall-, QR� 97601 Prepared by: Hc,nnes F� Norero, P.E. Florida Professional Engineer # 73778 Date: 11/15/2017 Contents: Evaluation Report Pages 1 - 4 Digitally signed by Hermes F. Norero, P.E, Reason: I am approving this document Date: 2017.11.17 10:34:29 .05*00' 0 0 7 41 0/0 Hermes P.E. Florida No. 73778 nBUILDING DROPS A Perfect Solution in Every Drop! Cert1ficate of Authorization: 29578 Manufacturer: Product Category: Product Sub -Category: Compliance Method: JELD-WEN, Inc. Exterior Doors Swinging Door Assemblies State Product Approval (1)(d) Product Name: Design Pro / Smooth Pro / Studio Fiberglass Impact Approved Opaque Doors For use in the High Velocity Hurricane Zone (HVHZ) 3'-G" X 6'-8" (Nominal) Y-0" X 8'-0" (Nominal) Date: 11/15/2017 Report No: 4663.1 Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) forJELD-WEN inc. based on Method ld of the Florida Department of Business and Professional Regulation - Florida Building Commission. Limits of Use; Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the current Florida Building Code. See Installation Instructions A010871, signed and sealed by Hermes F. Norero, P.E. (FL # 73778) for specific use parameters. 1. This product has been evaluated and is in compliance with the current Florida Building Code, including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Chapter 16 of the current Florida Building Code and does not require an impact resistant covering. 4. Site conditions that deviate from the details of drawing A010871 require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions A010871 for size and design pressure limitations. Hermes F. Norero, P.E. Florida No. 73778 Page 2 of 4 BUILDING DROPS A Perfect Solution in Every Drop! Date: 11/15/2017 certificate of Authorization: 29578 Report No: 4663.1 Quality Assurance Entity: The manufacturer has demonstrated compliance of products in accordance with the Florida Building Code for manufacturing under a Certification Agency through National Accreditation & Management Institute (FBC Organization #QUA1789). Performance Standards: The product described herein has been tested per: • TAS 201-94 • TAS 202-94 • TAS 203-94 Referenced Data: 1. Product Testing performed by National Certified Testing Laboratories (FBC Organization # TST1589) Report # Report Date: NCTL-210-3916-02 wl addendum 06/10/14 NCTL-210-3930-01 02/24/14 NCTL-210-3930-02 03/10/14 NCTL-210-3925-03 02/07/14 TAS Report Engineer of Record: Gerard J. Ferrara, P.E. Report # Report Date: SJW2013-194 w/ addendum 06/10/14 SJW2013-131-TAS 07/02/13 SJW2013-206-TAS 11/13/13 TAS Report Engineer of Record: Kevin P. Tyra, P.E. Report # Report Date: SJW2013-246 12/17/13 SJW2013-231 12/03/13 SJW2013-251 12/23/13 SJW2013-252 12/23/13 SJW2013-253 12/23/13 SJW2014-032 04/22/14 SIW2014-073 06/26/14 SJW2014-077 06/27/14 SJW2014-072 06/27/14 SJW2014-080 07/03/14 TAS Report Engineer of Record: Robert H. Zeiders, P.E. 2. Quality Assurance Entity National Accreditation & Management Institute (FBC Organization HQUA1789) Hermes F. Norero, P.E. Florida No. 73778 Page 3 of 4 BUILDING DROPS A Perfect Solution in Every Drop! Certificate of Authorization; 29578 Date: 11/15/2017 Report No: 4663.1 Component Material Testing of Dylite Expandable Polystyrene by Intertek Testing Services NA, Inc. ASTM E84 Report#: 3113726SAT-001 Rl Report Date: 03/13/09 4. Component Material Testing of Fiberglass SIVIC Skin Element Materials Technology ASTM D635, ASTM D638, ASTM D1929, ASTM D2843, ASTM G155 Report#: ESP010982P Report Date: 02/26/13 Installation: 1. Approved anchor types and substrates areas follows: Through Frame installation: A. For two by (2X) wood buck substrate (Min. S.G. = 0.55), use #10 Wood Screw type installation anchors of sufficient length to achieve a minimum embedment of 1.50" into B. For concrete (Min. f'c = 3000 psi) or masonry (Conforms to ASTM C90) substrate where one by (IX), non-structural, wood bucking is employed, use 3/16" diameter ITWTapcon orY4" Elco Ultracon type concrete screw anchors of sufficient length to achieve minimum embedment of 1.25" into concrete or masonry. C. For concrete (Min. Fc = 3000 psi) or masonry (Conforms to ASTM C90) substrate where wood bucking is NOT employed, use 3/16" diameter ITW Tapcon or Y." Elco Ultracon type concrete screw anchors of sufficient length to achieve minimum embedment of 1.25" into concrete or masonry. Refer to Installation Instructions (AO10871) for anchor spacing and more details of the installation requirements. Design Pressure: MAX. OVERALL NOMINALSIZE DESIGN PRESSURE (PSF) L415SILE CON11GURATION IMPACT RATING WIDTH HEIG14T F INSWING OUTSWING --POS---F— �is_ NEG. POS. r NEG.. X 3' 011 -0" 61.— .8. =_ : =65 6.5' 65 X Y-0" 4 81-01, 50, So SO- SO LMI&SMI �_j Hermes F. Norero, P.E. Florida No. 73778 Page 4 of 4