EVALUATION REPORT
SCANNED
ERD BY
St. Lucie County
TRI-BUILT Materials Group, LLC
PO Box 70
Rutherford, NJ 07070
(800) 516-1485
EXTERIOR RESEARCH & DESIGN, U.C.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT 1!13
OXFORD, CT 06478
(203) 262-9245
Evaluation Report A42960.10.12-R6
Date of issuance: 10/25/2012
Revision 6: 09/25/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with tl�IesewN!Zd tion-(2017)-,FIorId"uiIdifi—g Cddee]
sections noted herein.
DESCRIPTION: TRI-BUILT Roof Underlayments
LABEUNG: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPUANcE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinityl ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVEFMSEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6
Prepared by:
'011111111" --
.'A
3 21� S
Robert J.M. Nieminen, P.E.
. . ..
Florida Registration No. 59166, Florida DCA ANE1983
ci..e�L
CERTIFICATION OF INDEPENDENCE:
1. TrInItylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This'is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any my, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
FILE COPY
1tqL'fi
ST. LUCIE COUNTY
�NG DIV )N
REVIEWED 0
FOR Cc
REVIEWED BY
DATE
PLANS AND PERMITVUST BE KEPT ON JOB
SITE OR NO INSPECTION(S) WILL Be MADE
A
, k,-
r_\K__),
"T NITYJ ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: TRI-BUILT Roof Underlayments, as produced by TRI-BUILT Materials Group, LLC, have
demonstrated compliance with the following sections of the 6" Edition (2017) Florida Building Code through testing
in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations
Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1504.3.1
Wind Resistance
FM 4474
2011
1504.3.1
Wind Uplift
UL 1897
2012
1504.6
Accelerated Weathering
ASTM G155
2005
1507.2.4 / 1507.1.1, 1507.2.9.2
Physical Properties
ASTM D1970
2015
1507.3.3
Physical Properties
FRSA/TRI April 2012 (04-12)
2012
3. REFERENCES:
Entity
Examination
Reference
Date
ERD (TST6049)
Physical Properties
S40540.02.13-1
02/19/2013
ERD (TST6049)
Physical Properties
S40540.11.13
11/19/2013
ERD (TST6049)
Physical Properties
S40540.03.14
03/2612014
ERD (TST6049)
Physical Properties
S44870.04.14-2
04/02/2014
ERD (TST6049)
Physical Properties
544870.04.14-3
04/02/2014
ERD (TST6049)
Physical Properties
S44870.04.14-1
04/10/2014
ERD (TST6049)
Physical Properties
S44870.04.14-4
04/10/2014
ERD (TST6049)
Physical Properties
S43530.02.14-1-Rl
05/14/2014
ERD (TST6049)
Physical Properties
S43530.05.14
05/28/2014
ERD (TST6049)
Physical Properties
S40540.10.14
10/31/2014
ERD (TST6049)
Physical Properties
SC7645.02.15
02/13/2015
ERD (TST6G49)
Accelerated Weathering
SC8520.04.15
05/27/2015
ERD (TST6049)
Wind Resistance
SC14045.05.17-RI
06/07/2017
UL, LLC. (QUA9625)
Quality Control
Multiple -Listing R16814
12/10/2015
UL, U.C. (QUA9625)
Quality Control
Service Confirmation
Exp. 07/18/2020
4. PRODUCT DESCRIPTION:
4.1 C::I�!:BFjilt-SWn-d-R�-9-A-Sfiig-91FUn-dirl5yM—en is a self -adhering, glass -mat reinforced, sand -surfaced, SBS
modified bitumen roof underlayment, with a 36-inch sheet width; meets ASTM D1970.
4.2 Tri-Built S/A HT TU Underfayment is a self -adhering, non -woven polyester fabric surfaced, SBS modified
bitumen roof underlayment; meets ASTM D1970 and FRSA/TRI April 2012.
4.3 Tri-Built Smooth HT S/A Underlayment is a self -adhering, glass -mat reinforced, film -surfaced, SBS
modified bitumen roof underlayment; meets ASTM D1970.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nienninen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Reportzoir previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
Exterior Research and Design, U.C. Evaluation Report A42960.10.12-R6
CertrTicate of Authorization #9SO3 EDITION (2017) FBC NON-HVHZ EVALUATION FL16G48-R6
TRI-BUILT Roof Underlayments, (900) 516-1485 Revision 6; 09/25/2017
Page 2 of 6
r_\/'�
��TRINITYJERD
5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product is
specifically referenced within FBC approval documents. If not listed, a request may be made to the
Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the
prepared roof covering.
5.5 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
Underlayment
Asphalt
Nail -On Tile
Foam -On Tile
Metal
Wood Shakes
Slate
Shingles
& Shingles
a.i 1 --B-6 i I t S an dz R'S X S h I h jfe__�
I,UQnderlayrnen
i=1 29R,
No
No
No
Yes
Yes
Tri-Built S/A HT TU
Yes
Underlayment
Yes
Yes
See 5.5.1
Yes
Yes
Yes
Tri-Built Smooth HT S/A
Underlayment
Yes
No
No
Yes
Yes
Yes
S.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations.
TABLE 1A. ALLowABLETjLE ADHESIVE / UNDERLAYMENT COMBINAnONSI
Adhesive
Florida Product Approval
I Underlayments
ICP Adhesives PolysetO AH-160
FL6332
Tri-Built S/A HT TU Underlayment
DowTlleBond�
FL22525
Tri-Built S/A HT TU Underlayment
5.6 Allowable Substrates:
-7 - ------
5.6.1 X!_'DirjcVB6fi_d_'toTDeck?
V---Tri7�B�ilt-SandTR.SA.S'hinglEi�Unde—Fli@!eLn:lt, Tri-Built S/A HTTU Underlayment arTri-Built Smooth HT S/A
Underlayment applied to:
> Plywood; ASTIVI D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41
primed Southern Yellow Pine; ASTIVI D41 primed structural concrete.
While not required over plywood, OSB or Southern Yellow Pine substrates, TRI-BUILT Materials Group, LLC
recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Note:
TRI-BUILT Materials Group, LLC requires tongue -and -groove board decking be covered with plywood or
OSB prior to installation of the self -adhering underlayment.
5.6.2 Bond -to -Insulation:
Tri-Bullt Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
> Dens Deck Prime; SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam -on tile systems (Tri-Built S/A FIT TU Underlayment only), insulation attachment shall be
designed by a qualified design professional and installed based on testing of the insulation/underlayment
system in accordance with FM 4474, Appendix D orTAS 114, Appenclix.l.
I Refer to rile Manufacturer's orAdhesive Manufacturer's Florida ProductApprovalforOvertuming Moment Resistance Performance.
Exterior Research and Design, I.I.C. Evaluation Report A42960.10.12-R6
Certificate of Authorization #9503 0 EDITION (20171 FBC NON-HVHZ EVALUATION FL16048-R6
TRI-BUILT Roof Underlayments; (800) 5115-1485 Revision 6: 09/25/2017
Page 3 of 6
"� rTRINITY I ERD
S.6.3 Bond to Mechanically Attached Base Layer:
Tri-Built Sand-11 SA Shingle Underlayment, Tri-Built S/A HT TIJ Underlayment or Trii-Buift Smooth HT S/A
Underlayment applied to:
> ASTM D226, Type I or 11 felt.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam -on tile systems (Tri-Built S/A HT TIJ
Underlayment only), base layer shall be attached per minimum requirements of FRSA/TRl April 2012 (04-
12).
5.6.4 Wind Resistance for UnderlaVment SVstems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where
the underlayment forms part of the load -path. The following wind uplift limitations apply to direct -deck
underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile
applications. Maximum Design Pressure is the result of testing for wind load resistance based on
allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety
per FBC 1504.9 has already been applied). Refer to FRSA/TRl April 2012 (04-12), Appendix A, Table 1A or
FBC 1609 for determination of design wind pressures.
#1 Maximum Design Pressure =-45.0 p :
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional) ASTM D41 or RESISTO EXTERIOR PRIMER
Underlayment: Tri-Built S/A HT TIJ Underlayment, self -adhered.
#2 Maximum Design Pressure = -67.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: Soprema Elastocol 600c
Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered.
#3 Maximum Desien Pressure =-150.0 Dsf
Deck:
Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project
requirements to satisfaction of Authority Having Jurisdiction.
Deck Preparation:
Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit
adhesion. All sheathing fasteners shall he driven flush with the surface. All sharp
splinters and wood projections shall be removed/sanded.
Primer:
(Optional) RESISTO EXTERIOR PRIMER
Underlayment:
Tri-Built S/A HT TU Underlayment, self -adhered, shall be thoroughly roll using hand
roller and/or weighted roller to ensure there are no voids, and ensure there are no
voids/bridging at side and end -laps.
#4 Maximum Design Pressure =-60.0 psf:
Deck:
Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet:
Soprema Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1)
and tin caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three,
equally spaced rows in the center of the sheet.
Underlayment:
Tri-Built S/A HT TU Underlayment, self -adhered.
Exterior Research and Design, I.I.C.
Cenufloate of Authorization #9503 6m EDITION 12017) FBC NON-HVHZ EVALUATION
TRI-BUILT Roof Underlayments; (800) 516-1485
Evaluation Report A42960.10.12-RG
FL16048-R6
Revision 6:09/25/2017
Page 4 of 6
r-�'�
'N,,, rTRINIW I ERD
5.6.4.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet
or exceed that required under FRSA/TRl April 2012 (04-12), Appendix A, Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1
design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an
attachment density designed by a qualified design professional to resist the elevated pressure criteria.
Commonly used methods are ANSI/SPRJ WDI, FM Loss Prevention Data Sheet 1-29 and Roofing
Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in
Section 2.2.20.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Tri-Built Sand-R SA Shingle Underlayment or Trii-Built Smooth HT S/A Underlayment shall not be left
exposed for longer than 30-days after installation
Tri-Built S/A HT TU Underlayment shall not be left exposed for longer than 18G-days after installation.
5.8 'rile Slippage Limitations (TAS 103 per FRSA/TRI April 2012 (04-12)1:
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall
be as follows. These slope limitations can only be exceeded by using battens during loading of the roof
tiles.
TABLE 2: TILE SLIPPAGE LIMITATIONS FOR DIREcr-DEcK TILE INSTALLATIONS
Maximum
Underlayment
Tile Profile
Staging Method
Slope
Flat
Max. 10-tile stack
6:12
Lugged
Max. 10-tile stack
5:12
Max. 10-tile stack (bottom 2-tile stack
shall be inverted, followed by 8 tiles high 6:12
on slope, as shown below)
Tri-Built S/A HT TU
Underlayment
Lugged
I
Exterior Research and Design, U.C. Evalisation Report A42960.10.12-R6
Ceroftcate ofAuthorizabon #9503 6P EDITION (2017) FBC NON-HVHZ EVALUATION FL16048-R6
TRI-BUILT Roof Underlayments; (900) 516-1485 Revision 6:09/25/2017
Page 5 of 6
, �1'1
��TPJNITYJERD
6. INSTALLATION:
6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT Materials Group, ILLC
published installation requirements subject to the Limitations set forth in Section 5 herein and the
specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application, and prime the substrate (if applicable).
6.3 Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
6.3.2 Non -Tile applications
While priming is optional, TRI-BUILT Materials Group, LLC recommends priming the deck if the final roof
cover is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3
ft of release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel -off the release film diagonally while holding the
membrane tight. Firmly roll, broom or hand -press the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams in the course below, sealed in accordance with
TRI-BUILT Materials Group, LLC requirements.
When installing at slopes above 8:12, TRI-BUILT Materials Group, LLC recommends back -nailing in the
overlap area at the top of the sheet at 12-inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in
eachdirection. For valleys, apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Applications [Tri-BuiltS/A HTTU Underlayment only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table I herein, using the
instructions noted above as a guideline.
For foam -on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that
fall outside the scope of FRSA/TRI April 2012 (04-12).
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment. See Table 2 herein, and TRI-BUILT Materials Group, LLC published requirements for tile
staging.
BUILDING PERmtr REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACrURING PLANTS:
Gulfport, MS
9. QUALITY ASSURANCE ENTITY:
UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
END OF EVALUATION REPORT -
Exterior Research and Design, I.I.C. Evaluation Report A42960.10.12-H6
certificate of Authorization #9503 e EDITION 12017) FBC NON-HVHZ EVALUATION FL16048-RG
TRI-BUILT Roof Underlayments, (800) 516-1485 Revision 6:09/25/2017
Page 6 of 6
SCANNED
'Y
��TPJNIW � ERD st- Lucie county
EVALUATION REPORT
GAF
I Campus Drive
Parsippany, NJ 07054
(800) 766-3411
EXTERIOR RESEARCH & DESIGN, U.C.
Certfficate ofAuthorization #9503
353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
(203) 262-9245
Evaluation Report 01506.01.09-1122
e-ffift-Z�00
Date of Issuance: 01/03/2008
Revision 22:09/20/2017
SCOPE:
This Evaluation Report is issued under Rule 6IG2G-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product Under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with t"- th dE
_1"qLn-J.2D --F _S§_ I
sections noted herein.
DESCRIPMON: GAF Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1/ R905.2-6.1.
CoNnNUED CompuANcE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. TrinitVIERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVEWnSEMENT: The Evaluation Report number preceded by the words 'Trinityl ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECriON: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
� �k �1 app�M � a�� bV ko� Nkmimn,
P-LonWIM/2017. Wm�n�wanele�n!�Slysig�
�ent
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity[ ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any Company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not haw, nor will acquire, a financial interest in any other entity involved in the approval process of the
producL
S. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/ms used for permitting or design guidance unless retained
specifimily for that purpose.
��TRINITYJERD
ROORNG SysTEms EVALUATION:
1. SCOPE:
Product Category. Roofing
Sub -Category: AsphaltShingles
Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the
following sections of the 6h Edition (2017) Florida Building Code and Florida Building Code, Residential Volume
through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements
and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section Prope Standard Year
1507.2.4/1507.1.1, Physical Properties ASTM D1970 2015
R905.2-3 / R905.1.1
1507.2.5, R905.2.4 Physical Properties ASTM D3462 2010
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2016
1507.17.1, R90�1.6.1 Wind Resistance ASTM D7158 2011
1507.2.7.1, R905.2.6.1 Wind Resistance TAS107 1995
3. REFERENCES:
En Examination Reference Date
GAF (PDM 1915) Letter of Equivalency Seal -A -Ridge Impact Resistant IR 01/13/2012
PRI (TST 5878) Physical Properties GAF-025-02-01 03/27/2002
PRI (TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004
PRI (TST 5878) ASTM D3462 GAF-080-02-01 OS/25/2005
PRI (TST 5878) Physical Properties GAF-324-02-01 12/01/2011
PRI (TST 5878) Wind Driven Rain GAF-407-02-01 01/21/2013
ULW1740) ASTM D3462 93NK6295 11/29/1993
UL(TST1740) ASTM D3462 99NK43935 01/12/2000
UL (TST 1740) TAS107 94NK9632 03/29/2000
UL (TST 1740) ASTM D3462 DINK06632 02/02/2001
UL (TST 1740) ASTM D3161, TAS 107 OINK9226 05/21/2001
UL(TST1740) ASTM D3161 OINK37122 12/18/2001
UL(M 1740) ASTM D3462 01NK37122 12/19/2001
UL(TST1740) ASTM D3161, TAS 107 02NK12980 04/10/2002
UL (TST 1740) ASTM D3161, TAS 107 02NK30871 09/09/2002
UL (TST 1740) ASTM D3161 03CA5367 03/11/2003
UL (TST 1740) ASTM D3462 03NK26444 10/17/2003
UL(TST174O) ASTM D3462 04NK13850 06/07/2004
UL (TST 1740) ASTM D3161 04NK13850 06/23/2004
UL(TST1740) ASTM D3161 04NK30546 03/10/2005
UL (TST 1740) ASTM D3462 04NK22009 05/06/2005
UL (TST 1740) ASTM D3161 04NK22009 05/09/2005
UL M 1740) ASTM D3462 05NK27924 02/10/2006
UL (TST 1740) ASTM D3161 05NK27924 02/11/2006
UL(TST1740) ASTM D3161, D3462 06CA18077 06/05/2006
UL(TST1740) ASTM D3161, D3462 06CA18074 06/16/2006
UL (TST 1740) ASTM D3161, D3462 06CA35251 10/18/2006
UL 0 ST 1740) ASTM D3462 06CA31603 12/01/2006
UL (TST 1740) ASTM D3161,D3462 06CA41095 12/27/2006
UL (TST 1740) ASTM D3161 07NK05228 03/13/2007
UL (TST 1740) ASTM D3161 06CA31611 04/04/2007
UL M 1740) ASTM D3161 06CA61148 04/09/2007
UL (TST 1740) ASTM D3161, D3462 07CA31742 11/08/2007
UL (TST 1740) ASTM D3161, D7158, D3462 08CA06100 03/13/�008
Exterior Research and Design, I.I.C. Evaluation Report 01506.01.08-R22
Certiff� ofAuthoInvDan #9sa3 EDITION (20171 FBC NON-HVHZ EvALuA-nON FL10124-R20
GAF Asphalt Roof shingles Revision 22.09/20/2017
Page 2 of 6
r-�'�
I T INITY I ERD
111"N
Entity
Examination
Reference
Date
UL(TST1740)
ASTM D3161, D3462
07CA55908
04/01/2008
UL(TST1740)
ASTM D3161,D3462
09CA10592
03/26/2009
UL (TST 1740)
ASTM D3161,D3462
09CA06856
05/15/2009
UL (TST 1740)
ASTM D3161,D7158,D3462
09NK06647
08/01/2009
UL (TST 1740)
ASTM D3161,D7158,D3462
09CA27281
08/27/2009
UL (TST 1740)
ASTM D3161, D7158, D3462
10CA35554
03/OS/2010
UL (TST 1740)
ASTM D3161, D7158, D3462
10CA13696
05/15/2010
UL (TST 1740)
ASTM D3462
10CA07264
05/27/2610
UL(TST1740)
ASTM D3462
10CA11953
10/29/2010
YL (TST 1740)
ASTM D3161, D7158, D3462
IONK11951
'IONK12670
10/30/2010
UL (TST 1740)
A.-�TM D37161, D�158, 63462
-Z: -
-�1/04/2010
UL (TST 1740)
ASTM D3161,D7158,D3462
08CA05100
01/30/2010
UL (TST 1740)
ASTM D3161,D7158,D3462
1OCA53934
03/31/2011
UL (TST 1740)
ASTM D3161,D7158,D3462
11CA48924
10/22/2011
UL (TST 1740)
ASTM D3161,D7158,D3462
11CA47919
12/03/2011
UL (TSr 1740)
ASTM D3161, D7158, D3462
11CA48408
12/08/2 Z011
UL (TST 1740)
ASTM D3161,D7158,D3462
11CA48725 09
092/2012
UL, ULC (TST 9628)
ASTM D3462
12CA34891
UL, U-C- (TST 9628)
ASTM D3161,D7158,D3462
12CA58151 I-r--02/15/2013
UL, LLC. (TST 9628)
ASTM D3161
12CA38083
02/26/2013
UL, U.C. (TST 9628)
ASTM D3161
13CA32332
06/18/2013
UL, LLC (TST 9628)
ASTM D3161
13CA37934
08/02/2013
UL, U.C. (TST 9628)
ASTM D3161,D7158,D3462
4786875675
07/17/2015
UL, U.C. (TST 9628)
ASTM D3161,D7158,D3462
4787434542
05/17/2016
UL, LLC. (QUA 9625)
Quality Control
Inspection Report, R21, Mobile, At
10/25/2016
UL, LLC. (QUA 9625)
Quality Control
Inspection Report R21, Myerstown, PA
10/20/2016
UL, LLC- (QUA 9625)
Quality Control
Inspection Report, R21, Tuscaloosa, At
11/11/2016
UL, LLC. (QUA 9625)
Quality Control
Inspection Report, R21, Michigan Cty, IN
11/01/2016
UL, LLC. (QUA 9625)
QualityControl
Inspection Report, R21, Shafter, CA
11/17/2016
UL, LLC- (QUA 9625)
Quiility Control
Inspection Report, ft2l,'Savanfiah, GA
11/11/2016
UL, U-C- (QUA 9625)
Quality Control
Inspection Report, R21, Minneapolis, MN
10/25/2016
UL, U.C. (QUA 9625)
Quality Control
Inspection Report, R21, Mt. Vernon, IN
10/25/2016
UIL, LLC. (QUA 9625)
Quality Control
Inspection Report, R21, Baltimore, MD
10/21/2016
UL, LLC. (QUA 9625)
Quality Control
Inspection Report, R21, Tampa, FL
11/17/2016
UL, U.C. (QUA 9625)
Quality Control
Inspection Report, R21, Dallas, TX
11/04/2016
UL, U-C- (QUA 9625)
QualityControl
Inspection Report, R21, Ennis, TX
11/03/2016
UL, L.I.C. (QUA 9625)
QualitVControl
Inspectiati.Repoft, P2�, Fontana, CA
11/0112016
4. PRODUCT DESCRip'now
4.1 Asphatt Shingles:
4.1.1 MarquisO WeatherMaxO, Royal SovereignQ and
SentinelO are a fiberglass reinforced 3-tab asphalt roof
shingles.
4.1.2 CamelotO, CamelotO 11, -Fortitude, Glenwoodm,
Grand CanyonO, Grand SequoiaO, Grand SequolaO IR,
Grand SequoiaO
ArmorShieldm, MonacoO, SiennaO, TimberlineO American HarvestO, TimberlineO
ArmorShielcl� 11, TimberlineO Natural ShadowO, Timberline
HD; 2,ffibe me Cool SeriesO. Timberline Ultra
HDO and WondlandO are fiberglass reinforced, laminated asphalt roof shingles.
..-d
4.1.3 SlatelineO is a fiberglass reinforced 5-tab asphalt roof shingle.
4.2 Hip & Ridge Shingles
4.2.1— Seal-A-RidgeO Ridge Cap Shingles, Seal-A-RidgeO IR Impact -Resistant Ridge Cap Shingles,- Seal-A-RidgeO
ArmorShieldm Ridge Cap Shingles and TimbertexO
Premium Ridge Cap Shingles
are fiberglass reinforced, hip
and ridge asphalt
roof shingles.
GO
AiINI'*d-L
Exterior Research and Design, LLC.
I valuation Report so .01.
C�fl�OfAutho=Von"503
6m EDITION (2017) FBC NON-HVHZ EVAWATION
FI-10124-1120
GAF Asphalt Roof Shingles Revision 22-.09/20/2017
Page 3 of 6
911-st'0911A NoiLvnivA3 ZHAH-NON 393 (LICZ) NO[11(13 M9
-JTAINFTY�RD
4.3 Accessory Starter Strips:
4.3.1 Pro-StartO Eave/Rake Starter Strip Shingles and Weatherillocker' Premium Eave/Rake Starter Strip Shingles
are starter strips for asphalt roof shingles.
4.3.2 QuickStartO Peel & Stick Starter Roll is a is a mineral -surfaced, fiberglass -reinforced, self -adhering SBS
modified ' bitumen starter strip, nominal 9-inch x 33 ft roll, for use with asphalt shingles with exposure of 6-
inchorless.
4.3.3 Starterlvlatch� Starter Strip Shingles are color -coordinated starter strips for use with Grand Canyon" and
Grand Sequoias series asphalt shingles. StarterMatch� are installed as the second starter for Grand
CanyonO and Grand Sequoias series installations.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trmityj ERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any projed on which this Evaluation Repoirt,_or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is notfor use in FBC HVHZjuriscfictitons�
5.3 Fire Classification is not part of this Evaluation Report, refer to current Approved Roofing Materials
Directory for fire ratings of this product.
SA Wind Classification:
5.4.1 The GAF asphalt shingles noted in Section 4.1 are Classified in accordance with FBC Tables 1507.23A and
R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are.acceptable for
use in all wind zones up to V.,d = 150 mph (V�ft = 194 mph). Refer to Section 6 for installation requirements
to meet this wind rating.
SA.2 The GAF hip& ridge shingles noted in Section -4.2 are Uassified in accordance with-FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up
toV,,d=150 mph (Vult=194mph). Refer to Section 6 for installation requirements to meet this wind rating.
5A.3 Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609A.3, and a
mean roof height of 60 feet or less. Calculations by a qualified design professional are required for
conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with FJLC. Rule 61G20-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewitcle Product Approval, or be
Locally Approved per Rule 614320-3, per FBC 1507.2.3, 1507.2.4 or R905.2.3.
6.2 Starter Shingles or Starter Strip:
6.2.r Installation of Pro -Start Eave/Rake Starter Strip Shingles, WeatherBlocker Premium Eave/Rake Starter Strip
Shingles and QuickStart Peel & Stick Starter Roll shall comply with the GAF current published instructions.
6.3 Asphalt Shingles:
6.3.1 Installation of asphalt shingles shall comply with the GAF current published instructions, using minimum four
(4) nails per shingle in accordance with FHC 1507.2.7 or R905.2.6, with the following exceptions:
• Camelot, Camelot 11, Grand Canyon, Grand Sequoia, Grand Sequoia IR, Grand Sequoia ArnnorShleld,
and Woodland require minimo'm five (5) nails per shingle.
• Slatefine requires minimum six (6) nails per shingle.
6.3.2 Fasteners shall be in accordance with manufacturer's published -requirements, but not -less than FBC 1507.2.6
or R905.2.5. Staples are not permitted.
6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. Contact the GAF for details.
Evaluation Report 01506.01.08-RZZ
e EDITION (2027) FBC NON-HVHZ EVAWAT10N FL10124-FL20
GAF Asphalt Roof Shingles Revision 22:09/20/2017
Page 4 of 6
911-8t,09TIA
NoLLvn1VA3ZHAH-NON:)9:I UTOZ) NOIIIC13 m9
"J�Tu- s R1 r4 J�T�Y JERD
6A Hip & Ridge Shingles:
6.4.1 Installation of Seal -A -Ridge Ridge Cap Shingles, Seal -A -Ridge IR Impact -Resistant Ridge Cap Shingles and
Seal -A -Ridge ArmorShield Ridge Cap Shingles shall comply with the GAF current published instructions with
a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and nominal 0.25-inch diameter
beads of Henkel "Loctite Pl. S30 Roof & Flashing Sealant".
seuante
Endu'd d6tanch6iW
12,
(305 MM)
Nail
Clove
6 518- - 7 d5.18' Clouer
(168 -194 mm)
12'
6A.2 Installation of Turibertex Premium Ridge *Cap Shingles shall comply with GAF current published instructions
with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and beads of Sonnebom NPI
Gun Grade Polyurethane Sealant or Henkel PL Roofing and Flashing Sealant.
Its, Sealant
MM) Sellmho
(2M5
End6iit ddtzrzh&ti
I
71
ir
-(3C5 Wo
6.4.3 Fasteners shall be in accordance with GAF published requirements, but not less than FBC 1507.2.6 or
R905.2.5. Staples are not permitted.
e EDITION (2017) FBC NON-HVMZ EVALUATION
GAF Asphalt Roof Shingles
Evaluation Report 01506.01.08-1122
FL10124-R20
Revision 22.09/20/2017
Page 5 of 6
9u-gtpc)9TIA Noi1.vmvA3 ZHAH-NON 383 (ITOZ) N0111133 M9 ��TRINrryj�RD
7. LABELING: -311 lugisaa pue qDjeasoN joIjajx3
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1 / R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority �aving Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFAcTuRING PLANTS:
Contact the named QA entity for information on which plants produce liroducts; covered by Florida Rule 61G20-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
LIL LLC—QUA9625; (847) 664-3281
rl* " ' .'
Exterfor Research and Design, LLr—
.. Wit f "n 03
GO
n
- END OF EVALUATION REPORT-