September 24, 2018
SCANNED
Re: Shutter Installation RECEIVED BY
9900 S. Ocean Dr. (#906) St. Lucie County
Jensen Beach, FL 34957 SEP 2 6 2018
ST. LUGIQ county, ParmittjnQ
To Whom It May Concern:
Our office has calculated the required design pressures in accordance with ASCE 7- 10
and Florida Building Code 2017 for the installation of accordion shutters at the above
referenced address.
Wind speed: Vuit: 165 mph, V�d: 128 mph
Exposure: D
Enclosure Type: Enclosed
Shutter Size: 96" Maximum Height
Shutter Location: Covered Porch (See Attached Sketch)
Required Design Pressure: +51.3 / -68.7 PSF
Shutters to be installed shall be equal to, or exceed the required design pressures as listed
above "Required Design Pressure'.
Accordion Shutters shall be installed in accordance with the shutter manufacturer's
installation instructions and Florida Product Approval and Florida Building Code 2017.
Accordion Shutters shall be FL# 389. 1.
Thank you for your attention to this matter.
SubmPed by:
PAUArLCH INC.
1-1�
Paul'jelcli, P.E.
Reg. N� �9945