Manufacturer:
Profiles:
Code:
Wind Speed:
Exposure:
Risk Category:
Mean Roof Height:
Pitch:
Required Design Pressure:
Maximum Uplift Pressure:
Base:
Ply Sheet:
Cap:
Roof Decking:
Polyglass USA
Modified Bitumen Roof System, FL#1654.1
FBC 2017
160 MPH; Ultimate Design Wind Speeds
B
30'Maximum
X /12
Zonel: -26 Zone 2: -41 Zone3:-57
-90 psf, System # W-140
SB5-SA
(Optional) SBS-SA, SBS-TA, APP-TA
SBS-AA, APP-SA, SBS-TA, APP-TA
Existing 5/8" plywood sheathing to be nailed w/8d x 2" ring shank @ 6"
O,C. thru out Zone 1, 4" O.C. perimeter, and 6: O.C. field zone 2, and 4"
O.C. thru out Zone 3 or 1 x 4 planks w/2 nails per plank per member
The above approved, as per Florida Building Code Compliance acceptances, 2017 Florida Building Code,