HomeMy WebLinkAboutMISC LETTER0 0�45r kSUMMIT ,N��k DESIGN & FORENSICS, INC. June 19,2018 Dade Service Corporation Mr. OJ Perryman 700A Fentress Boulevard Daytona Beach, Florida 32114 RJE: Roof Framing Review Natalie's Orchid Island Juice Company 1650 Digiorgio Road Fort Pierce, Florida 34982 Dear Mr. Perryman, SCANNED BY 9t Lucie County As requested, Summit Design & Forensics, Inc. (Summit) has reviewed the existing roof framing at the above captioned address to verify if the framing is structurally adequate to support an insulated panel system attached to the existing purlins. It is our understanding that this system will add an additional dead load of 3 psf to the existing framing. Further, based on field measurements provided by Dade Service Corporation, the existing roof zee-purlins are 8 inch depth by 12 gage and are spaced at five feet on -center. Based on our review, the existing roof framing for the above captioned project will be structurally adequate to support the proposed insulated panel system load which weighs 3 psf. The attachments for this insulated panel system to the purlins shall be per details 4 and 5 on sheet A5 prepared by Dade Service Corporation and sealed by Anthony Lepore Architect dated June 19, 2018. The rods will be located at the butt joints of the ceiling panels and at each roof purlin. If you should have any questions, please call me at 772-285-0572. Respectfully Submitted, 0. Brian J. Maskol, P.E. Summit Design & Forensics, Inc. State of Florida License No. 66080 0.(,Cs, Summit Design & Forensics, Inc., 725 SE Port St. Lucie Blvd., Port St. Lucie, Florida 34984 Phone: 772-285-0572 - FL COA No. 30881