Product Evaluation Report
ADVANCED ALUMINUM
Aluminum Permadle Roof Panel over Plywood
Florida Product Approval # 1763.3 R3
Florida Building Code 2017
Per Rule 61620.3
Method: 1—D
Category: Roofing
Subcategory. Metal Roofing
Compliance Method: 61620.3.005(1)(d)
HVHZ
Product Manufacturer.
Advanced Aluminum
2941 Parkway Street
Lakeland, Florida 331
Engineer Evaluator:
Terrence E. Wolfe, P.E. #44923
Florida. Evaluation ANE ID:1920
Validator•
Brian JaksP.E #70159
'Contents:
Evaluation Report Pages 1-4
,11 e':YO,�i
��.
w��V10ENSFSq�:
Je
STATE OF
acr�rta� c"k A= O 3L19
cns �i�SS•. GS,�.
FL# 17633 R3 '
September 5, 2017
Force Engineering &Testing Inc
19530 Ttunble."uud Dri"c
Finmblr=77338
Compliance Statement:
The product as described in this report has demonstrated compliance with the
Florida Building Code 2017, Sections 1504.3.2, 3518.9,1523.6.5.2.4_
Product Description:
Aluminum Pennatlle Roof Panel, 0.030" Aluminum, 28" Coverage, through
fastened roof panel over APA Plywood decking. Non -Structural Application.
Panel Material/Standards:
Material: 0.030" Aluminum, ASTM B209 conforming to Florida Building Code
2017 Section 1507.4.3.
Panel Coating (Optional): Fluropono Coating byValsparCorp.
Yield Strength; Min. 25.0ksi
Corrosion Resistance: Panel Material shall comply with Florida Building Code
2017, Section 1S07.4.3
Panel Dimension(s):
Thickness: 0.030" min.
Coverage: 28' maximum coverage
Rib Height: 1 %" tall major rib at 7" O.C.
Panel Fastener:
#9-15x2-1/2'WoodbinderHSS304SSwith sealin washin
g ngorapprovedequal
Ye minimum penetration through plywood
Corrosion Resistance: Per Florida Building Code 2017, Section 1517.6.
Substrate Description:
1) For HVHZ construction, use 19/32" or greater APA Rated plywood or wood '
plank In reroofing applications where the deck is less than 19/32" thick (min.
15/32") the attachment of the decking in no case shall be less than 80 annual
ring shank nails at 6" O.C. Design of plywood and plywood supports are outside
the scope of this evaluation. Substrate must be designed in accordancew/
Florida Building Code 2017.
2) For Non-HVHZ applications, use min. 15/32" thick, APA Rated plywood over
supports at maximum 24" O.C. Design of plywood and plywood supports are
outside the scope of this evaluation_ Substrate must be designed in accordance
w/ Florida Building Code 2017.
FT.# 17613 R3
1r1 *'e
"O STATE OF
Fz pRI S7A %••t`�'•
a C04 ,rs Gj %
own ,'h�OrNALtlttt�N�`%
September 5, 2017
Allowable Design Uplift Pressures:
Force Engineernmng &Testing Tna
19530 Rambteww,d Drive
Humble= 77338
Table -a-
Maximum-Total Uplift Design PrcKsure:
VX.8 psf 2535 psf
Fastener Pattem:
24c14•
FastenerSpadng:
12.O.G 1
'Design Pressure indudes a Safety Factor =2.0.
Code Compliance: The product described herein has demonstrated compliance with
The Flodda.Building Code 2017, Section 15D43.2, 1518.9,1523.65.2A.
Evaluation Report Scope: The product evaluation Is limited to compliance with the structural wind load
requirements of the Florida Building Code 2017, as relates to Rule 61G20-3.
Performance Standards: The product described herein has demonstrated compliance with:
• TAS 125-03
• UL580-06- Test for Uplift Resistance ofRoof Assemblies
• UL 1897-32- Uplift Test for Roof Covering Systems
• TAS 500-95 -Test Procedure for Wind and Wind Driven Rain Resistance
of Discontinuous Roof Systems
TAS 110-00 - Accelerated Weathering/Salt Spray
Reference Data: L TAS 125-03: UL SBO-06 / 1897-D4 Uplift Test
Force Engineering & Testing, Inc (FBC Organization #TSi-5328)
Report No. 343-0150T-13A-C
2. TAS 100-95
Farabaugh Engineering &Testing, Inc (FBC Organization # TST-1654)
Report No. T225-13
3. TAS 110-0O:Fluropon°coating byValsparCorporation
A) ASTM G 155 by PRl Asphalt Technologies
B) ASTM B 117 by PRI Asphalt Technologies
A Certificate of Independence
By Terrence E. Wolfe, P.E. (No.44923) @ Force Engineering &Testing, Inc.
(FBC Organization #ANE ID: 1920)
Test Standard Equivalency: L The UL1M7-04test standard isequivalent tothe UL1897-12test standard.
J,
suu�rsve.
ona
FL# 17633 R3
5TA
5Pp•, A
�7O11
September 5, 2017
Force Rjnlgineerhkg &Testing Tnc.
19330'ft=b1c, u d Rive
$umbk,T%T7338
Quality Assurance Entity:
The manufacturer has established compliance of roof panel products in
accordance with the Florida Building Code and Rule 6113203.005 (3) for
manufacturing under a quality assurance program audited by an approved
quality assurance entity.
Minimum Slope Range:
2:12. Minimum Slope shall comply with Florida BuildingCode 2017, including
Section 1515.2.2 and in accordance with Manufacturers recommendations. For
slopes less than 3:12, lap sealant must be used in the panel side laps.
Installation:
Install per manufacturers recommended details and RAS 133.
Underlayment
per Manufacturer's Installation guidelines per Florida Building Code 2017 Section
1518.2, 1518.3, 1518.4.
Fire Barrier.
Any approved fire barrier having a current NOA. Refer to a current fire directory
listing for fire. ratings of this roofing system assembly as well as the location of
the fire barrier within the assembly. Fire classification is not part of this
acceptance.
Shear Diaphragm:
Shear diaphragm values are outsidethe scope of this report
Design procedure:
Based on the dimensions of the structure, appropriate wind loads are
determined using Chapter 16 of the Florida Building Code 2017for roof cladding
wind loads. These component wind loads for roof cladding are compared to the
allowable pressure listed above. Support framing must be in compliance with
Florida Building Code 2017 chapter 22for steel, Chapter 23 for wood and
Chapter 16 for structural loading.
FU 17633 R3
,4`E3 NtC [E f iy
No. 4499
a•. STATEOP
sa.�rimx �i P O R i D.
September 5, 2017
FASTENER PATON TYPE A. ATy2 0 C
14. 14"
#9-15 x 2-1/2" WOODBINDER HSS 304 SS W/ WASHER _
FASTENER PATTERN TYPE B,&T 12' 0 C J
�E r < r r afE r 'I
#9-15 x 2-1/2" WOODSINDER HSS 304 SS W/ WASHER
�'O.anN.ao,xto
I "SEP Or 5 2017
-32" OVERALL PANEL WIDTH
7"
1�314'1
��-Cwvt�� SMS
2811 COVERAGEWDtH
0 20M
P-ermdT
: Lle Profile
No.44923
Alt STATE OF
NOTE: ALWAYS INSTALL PANELS FROM RIGHT
TO LEFT ttaoWna uo at ridge tYom save) '
Note: Above is the general saew.pattem for Permatife.
For HVH2 zones or wind speed restPieted areas, please
see. the Permatila Load TCabje.r plywood testing
paper for proper fastehing'In your area.
FASTENERS 2-1/2, #9 304 SMINLESS
HEX HEAD SELF -DRILLING WITH
rnnn a ........__
sbis W Prod
cs
0
S�•,lm
No.4
923
a� STAT
OF 'd
0o
-•_
..* �e
,GPI'
SEP 0 5 2097
FASTENING