HomeMy WebLinkAboutBUILDING SCHEMATICBWOM'S PEAK ROOF HEIGHT vs DESIGN WIND PRESSURE FOR COMPONENTS&CL.ADDM (,&ZF,) FOR ASCE7-10 - PEAK ROOF HEIGHT LESS MAN OR EQUAL TO 60 FEET at BASIC WIND SPEED = 170 mph RISK CATEGORY l/ BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, WHOLESALE) PEAK ROOF L" LESS THAN 7'-9' L" GREATER OR EQUAL THAN 7'-9' AND LESS THAN 12'-J' L' GREATER OR EQUAL THAN 12'-3' HEIGHT POSITIVE NEGATIVE POSITIVE NEGATIVE POSITIVE NEGATIVE (h) ULTIMATE A.S.D. UL17MMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. 0' - 15' 76.4 45.8 102.4 61.4 73.0 43.8 95.5 573 68.5 41.1 86.4 51.8 > 15'-20' 80.4 48.2 107.6 64.6 76.8 46.1 100.4 60.2 72.0 4J.2 90.8 54.5 > 20'-25' 83.6 50.2 111.9 671 79.8 47.9 104.4 62.6 74.8 44.9 94.4 56.6 > 25'-30' 86.2 51.7 115.5 69.3 82.4 49.4 107.7 64.6 773 46.4 974 58.4 > 30-40' 90.7 54.4 121.4 72.8 86.6 52.0 113.3 68.0 81.2 48.7 102.4 61.4 > 4D'-5o' 94.3 56.6 12 75.7 90.0 54.0 1177 70.6 84.4 50.6 106.5 63.9 > 50'-60' 973 58.4 1326.0.3 78.2 92.9 1 55.7 1 121.5 72.9 87.2 1 52.3 109.9 1 65.9 SCANNED BY St. Lucie County INDICATED DESIGN WIND PRESSURES CORRESPOND TO THE MAXIMUM END ZONE AND INTERIOR ZONE CONDITIONS AND FOR ALL ROOF SLOPES. L = STORM PANEL LENGTH, ACCORDION SHUTTER BLADE LENGTH OR BAHAMA SHUTTER HEIGHT. * PRODUCTS WHICH BEAR A MI4M7-DARE COUNTY OR A STATE OF FLOR104 APPROVAL BUILDING'S PEAK ROOF HEIGHT vs DESIGN WIND PRESSURE FOR COMPONENTS & CLADDING (P S F) FOR ASCE 7 10 PEAK ROOF HEIGHT GREATER THAN 60 rrrT �r BASIC WIND SPEED = 170 mph RISK CATEGORY ll BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, WHOLESALE) PEAK ROOF I- LESS THAN 12-3' L- GREATER OR EQUAL THAN 12'-3' HEIGHT POSITIVE NEGATIVE POSITIVE NEGATIVE (h) ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. > 60' - 70' 91.5 54.9 1677 100.6 84.3 50.6 148.4 89.0 > 70' - 80' 93.6 56.2 171.6 103.0 86.2 51.7 151.9 91.1 > Bo' - 90' 95.6 57.4 175.2 105.1 88.0 52.8 155.0 93.0 > 90' - Too' 1 97.3 58.4 178.4 107.4 1 89.7 53.8 157.9 94.7 100.5 J'b`On3; : 184.2 @At101 .rJ 1 92.5 55.5 163.0 97.8 5 nw' - C46' 103.2 67.9 1 789.2 173.5 - 95.1 571 1674 100.4 > 140' - 160' 105.6 63.4 193.6 116.2 97.3 58.4 171.3 102.8 > 160' - 180' 107.8 64.7 1976 118.6 99.3 59.6 174.9 104.9 > 180' - 200' 109.8 65.9 201.3 120.8 101.1 60.7 178.1 106.9 > 200' - 250' 114.1 68.5 209.2 125.5 705.2 63.1 185.1 1 11.1 > 250, - JOo' 1778 70.1 216.0 129.6 108.5 65.1 191.1 114.7 > 300' - 350, 121.0 72.6 221.9 133.1 111.5 66.9 196.3 117.8 > :50' - a0o' 123.9 74.3 227.1 136.J 114. 1 68.5 200.9 120.5 > 4Do' - a5o' 126.4 75.8 231.8 139.1 116.5 69.9 205.1 123.1 > 450' - 5oo'l 128.8 1 773 1 236.1 141.7 118.6 71.2 208.9 125.3 g 1.) THIS CERTIFIED SIGNED AND SEALED WIND LOAD CHART, PREPARED BY THIS ENGINEER, BASED ON ASCE 7-10. FOR A BASIC WIND SPEED OF 170 MPH, AND APPLICABLE RISK CATEGORY BUILDING & EXPOSURES, IS COMPLETELY GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT. 2.) THIS WIND LOAD CHART MUST BE SIGNED. SEALED AND DATED BY THIS ENGINEER /F USED TO OBTAIN A ONE RME BUILDING PERMIT. S) CONTRACTOR OR PERMIT HOLDER 70 BE RESPONSIBLE FOR THE SELECTION OF DESIGN WIND PRESSURE BASED ON THIS GENERIC WIND LOAD CHART. WINO PRESSURES ARE ULTIMATE AND ASD. PRESSURES. 4.) THIS WIND LOAD CHART SHALL BE CONSIDERED INVALID IF ALTERED BY ANY MEWS 5.) DESIGN WIND LOAD SELECTED BY THE CONTRACTOR OR PERMIT HOLDER FROM THIS WIND LOAD CHART SHALL BE INDICATED ON A SEPARATE DOCUMENT PREPARED BY THE CONTRACTOR OR PERMIT HOLDER (e.g.. SPREADSHEET, OPENING SCHEDULE/TAKE OFF SHEET, ETC). A. NO.44167 0 3. 7R i •o g STA1� OF � • PEP0F (� 0 Go 2017 (6th EDI77ON) FLORIDA BUILDING CODE - BROWARD, PALM BEACH, MARTIN, ST. LUCIE & INDIAN RWER COUNTIES BUILDING'S PEAK ROOF HEIGHT vs DESIGN WIND PRESSURE FOR COMPONENTS A CLADDING (PSF,) FOR ASZE 7 10 PEAK ROOF HEIGHT LESS MAN OR EQUAL To an iTCT BASIC WIND SPEED = 170 mph RISK CATEGORY I/ BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, WHOLESALE) PEAK ROOF I'• LESS THAN 7'-9' L" GREATER OR EQUAL THAN 7'-9' AND LESS THAN 12'-3' L" GREATER OR EQUAL THAN 12'-3' HEIGHT POSITIVE NEGATIVE POSmVT NEGATIVE POSITIVE NEGATIVE (h) ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE ASO. ULTIMATE A.S.G. ULTIMATE AS.D. 0' - 15, 76.4 45.8 102.4 61.4 73.0 43.8 95.5 573 68.5 41.1 86.4 51.8 > 15'-20' 80.4 48.2 1076 64.6 76.8 46.1 100.4 60.2 72.0 43.2 90.8 54.5 > 20'-25' 83.6 50.2 111.9 67.1 79.8 479 104.4 62.6 74.8 44.9 94.4 56.6 > 25'-30' 86.2 51.7 115.5 69.3 82.4 49.4 107.7 04.6 1 77.3 46.4 974 58.4 30'-40' ' 90.7 54.4 121.4 72.8 86.6 52.0 113.3 68.0 81.2 48.7 102.4 61.4 40'-50' 94.3 56.6 126.2 75.7 90.0 54.0 1177 70.6 84.4 50.6 f06.5 63.9 50'-60' 973 58.4 730.3 78.2 92.9 55.7 121.5 72.9 872 52.3 709.9 65.9 * INDIC47ED DESIGN WIND PRESSURES CORRESPOND TO THE MAXIMUM END ZONE AND INTERIOR ZONE CONDITIONS AND FOR ALL ROOF SLOPES. L = STORM PANEL LENGTH. ACCORDION SHUTTER BLADE LENGTH OR SAHAMA SHUTTER HEIGHT. AY* PRODUCTS WHICH BEAR A M14M1-DADS COUNTY OR A STATE OF FLORIDA APPROVAL -�♦ _ :�� .l � a �a/ �: � '� aL• _ LIB •; • ;•• _. •� .� BASIC WIND SPEED = 170 mph RISK CATEGORY If BUILDINGS R£SIDENTL4L, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, WHOLESALE) PEAK ROOF L" LESS THAN 12-3' 1' GREATER OR EQUAL 710N 12'-3' HEIGHT POSITIVE NEGATIVE POSITIVE NEGATIVE (h) ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.O. > 60' - 70' 91.5 54.9 1677 100.6 84.3 50.6 148.4 89.0 > 70' - 80' 93.6 56.2 171.6 103.0 86.2 51.7 151.9 91.1 > 80' - 90' 95.6 57.4 175.2 105.1 88.0 52.8 155.0 93.0 > 90' - 100' 97.3 58.4 178.4 1074 1 89.7 53.8 157.9 94.7 0,12q' 100.5 184.2 TTO.!5 92.5 55.5 163.0 978 > 120' - 140' 103.2 61.9 189.2 113.5 95.1 57. 1 167.4 100.4 > 140' - 160' 105.6 63.4 193.6 116.2 97.3 58.4 171.3 102.8 > 160' - 180' 1078 64.7 1976 118.6 99.3 59.6 174.9 164.9 > 180' - 200' 109.8 65.9 201.3 120.8 101.1 60.7 178.1 706.9 > 200' - 250' 114.1 68.5 209.2 125.5 105.2 63.1 185.1 111.1 > 250' - 300' 7778 70.1 216.0 129.6 108.5 65.1 191.1 114.7 > 300' - 350' 121.0 72.6 221.9 133.1 111.5 66.9 196.3 117.8 > 350' - 400' 1239 74.3 2271 136.3 114.1 68.5 200.9 120.5 * 400' - 450' 126.4 75.8 231.8 139.1 116.5 69.9 205.1 123. 1 * 450' - 500' 128.8 77.3 1 236.1 1 141.7 1 118.E 1 71.2 208.9 1 125.3 No -_ 1.) THIS CERTIFIED SIGNED AND SEALED WIND LOAD CHART, PREPARED BY THIS ENGINEER, BASED ON ASCE 7-10, FOR A BASIC WIND SPEED OF 170 MPH, AND APPLICABLE RISK CATEGORY BUILDING & EXPOSURES IS COMPLETELY GENERIC AND DOES NOT PROVIDE INFORM47YON FOR A SITE SPECIFIC PROJECT. 2.) THIS WIND LCAD CHART MUST BE SIGNED, SEALED AND DATED BY THIS ENGINEER /F USED TO OBTAIN A ONE TIME BUILDING PERMIT. 3) CONTRACTOR OR PERMIT HOLDER TO BE RESPONSIBLE FOR THE SELECTION OF DESIGN WIND PRESSURE 84SED ON THIS GENERIC WIND LOAD CHART. WIND PRESSURES ARE ULTIMATE AND ASO. PRESSURES. 4.) THIS WIND LOAD CHART SHALL BE CONSIDERED /NVAUD IF ALTERED BY ANY MEANS 5.) DESIGN WIND LOAD SELECTED BY THE CONTRACTOR OR PERMIT HOLDER FROM THIS WIND LOAD CHART SHALL BE INDICATED ON A SEPARATE DOCUMENT PREPARED BY THE CONTRACTOR OR PERMIT HOLDER (e.g., SPREADSHEET, OPENING SC14EDULEITAKE OFF SHEET, ETC). ncu71 No.44161 *S * Z 0 .o'; STA1E 0� r ANn _ .•....•. l;.1C1. eRoo' l� 2077 (6th EDITION) FLORIDA BUILDING CODE - BROWARD, PALM BEACH, MARTIN, ST. LUCIE & IND14N RIVER COUNTIES