Loading...
HomeMy WebLinkAboutDESIGN CALCULATIONS�♦If..3/ 6/I i o Easy'Seats easyseals.com DESIGN CALCULATIONS FOR RAMEN HANG & WINGS WALL -MOUNTED SIGNS 6935 Heritage Drive — Port St Lucie SCANNED By GENERAL NOTES: Lucie County St. 1. Design is in accordance with the Florida Building Code 6th Edition(2017) for use within and outside the High Velocity Hurricane Zone (HVHZ). 2. Wind loads have been calculated per the requirements of ASCE 7-10 as shown herein. 3. These engineering calculations pertain only to the structural integrity of those systems, components, and/or other construction explicitly specified herein and/or in accompanying engineering drawings. The Index: existing host structure (if any) is assumed to be in good condition, Pg 1 Cover capable of supporting the loaded system, subject to building department Pg 2 Wind Loads approval. No warranty, either expressed or implied, is contained herein. Pg 3 ' Anchor Design 4. System components shall be as noted herein. All references to named components and installation shall conform to manufacturer's or industry specifications as summarized herein. 5. Where site conditions deviate from those noted herein, revisions may be y required or a separate site -specific engineering evaluation performed. Engi�e� t�iir °ahf� seal valid ���,� 6. Aluminum components in contact with steel or embedded in concrete •• � shall be protected as prescribed in the 2015 Aluminum Design Manual, `: No. 67 8 Part 1. Steel components in contact with, but not encased in, concrete shall be coated, painted, or otherwise protected against corrosion. - - -G • - 7. Engineer seal affixed hereto validates structural design as shown only. T C O �� :0�; . Oct Use of this specification by contractor, et. Al, indemnifies and saves harmless for & damages including legal fees Chrisjfafi ` R��# 67382 this engineer all costs & ., ♦► (, .s apellate fees resulting from deviation from this design. Ea : ' uth # 31124 Federal Hwy, g200 Ear Seals .com Page 1 Bocaoca Raton, ton, FL33432 7 E'asySeals CALCULATIII , S FOR WALL -MOUNTED SIGNS easysealzmm Yt ASCE 7-10 Design Wind Loads WALL -MOUNTED SIGNS Building Specs V = 160 mph Basic wind speed Exposure C Calculations a = 9.5 3-sec gust speed power low exponent zg = 900' Nominal ht. of atmos. boundary layer Gcpi = 0 Internal pressure coeff ASD Load Combo Coeff: 0.6 Kd = 0.85 Directionality factor Kzt = 1.0 Topographic factor A = 10 sq ft Tributary area 160 mph - Exp "C" WALL -MOUNTED SIGNS ASD WIND PRESSURES SIGN CENTER CORNER HEIGHT (Zone 4) (Zone 5) Y qz a U v a U ,;, Y 15 ft 31.2 psf 39.7 psf 0.85 47.3 -1.10 -1.40 20 ft 33.2 psf 42.2 psf 0.90 50.2 -1.10 -1.40 25 ft 34.8 psf 44.2 psf 0.95 52.7 -1.10 -1.40 30 ft 36.1 psf 46.0 psf _ 0.98 54.7 -1.10 -1.40 35 ft 37.3 psf 47.5 psf 1.01 56.5 -1.10 -1.40 40 ft 38.4 psf 48.8 psf 1.04 58.1 -1.10 -1.40 45 ft 39.3 psf 50.1 psf 1.07 59.6 -1.10 -1.40 50 ft 40.2 psf 51.2 psf 1.09 60.9 -1.10 -1.40 55 ft 41.0 psf 52.2 psf 1.12 62.2 -1.10 -1.40 60 ft 41.8 psf 53.2 psf 1.14 63.3 -1.10 -1.40 70 ft 35.3 psf 70.6 psf 1.17 65.4 -0.90 -1.80 80 ft 36.3 psf 72.6 psf 1.21 67.3 -0.90 -1.80 90 ft 37.2 psf 74.5 psf 1.24 69.0 -0.90 -1.80 100 ft 38.1 psf 76.1 psf 1.27 70.5 -0.90 -1.80 110 ft 38.8 psf 77.7 psf 1.29 71.9 -0.90 -1.80 120 ft 39.6 psf 79.1 psf 1.32 73.3 -0.90 -1.80 130 ft 40.2 psf 80.5 psf 1.34 74.5 -0.90 -1.80 140 ft 40.9 psf 81.7 psf 1.36 75.7 -0.90 -1.80 150 ft 41.5 psf 82.9 psf 1.38 76.8 -0.90 -1.80 175 ft 42.8 psf 85.7 psf 1.42 79.3 -0.90 -1.80 200 ft 44.1 psf 88.1 psf 1.46 81.6 -0.90 -1.80 250 ft 46.2 osf 92.3 osf 1.53 85.5 -0.90 -1.80 Page 2 CALCULATI. :IS FOR WALL -MOUNTED SIGNS ' Wall Sign Anchor Design Structure Dimensions & Loading Design wind pressure: Sign type: Sign size: Wall material: Anchor type/size: P = 46.0 psf Cabinet A= 24.0 sgft (entire cabinet) Masonry (ASTM C90, 1,500 psi min) 1/4" Tapcon Ref: ITW Tapcon, NOA 07-1126.10 Min Embedment: 1.25" Min edge dist: 2.5" Min Spacing: 3" Anchor tensile capacity: Tcap = 195.0 lb (per anchor) Check Anchors for Pullout Total Reaction: Rt = 1103 lb ... = P•A (entire cabinet) No. of anchors req'd: n = 5.7 total anchors ... = Rt/cap Total anchors required: 6 total anchors balanced over cabinet OK, critical anchor option shown. Limit to min (8) total. Ref anchor schedule for other anchor options. Page 3