Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PROJECT INFORMATION
BXUV.U443 - Fire Resistance R-tings - ANSI/UL 263 Page 1 of 3 Page Bottom Design No. U443 SXUV.U443 Fire Resistance Ratings - ANSI/UL 263 Design/system/Construction/Assembly Usage Disclaimer • Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials. • Authorities Having Jurisdiction should be consulted before construction. • Fire resistance assemblies and products are developed by the design submitter and have been Investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. • When field Issues arise, it Is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information Includes specifics concerning alternate materials and alternate methods of construction. • Only products which bear UL's Mark are considered Certified. BXUV - Fire Resistance Ratings - ANSI/UL 263 Certified for United States SXUV7 - Fire Resistance Ratings - CAN/ULC-S101 Certified for Canada See General Information r Fire -resistance Ratincis - ANSIIUL 263 Certified for United States Desion Criteria and Allowable Variances See General information r Fire Resistance Ratings - CAN/ULC-SIOI Certified for Canada SCANNED Desion Criteria and Allowable Variances BY Design No. U443 St. Lucie County August IS, 2018 Nonbearing Wall Rating — 2 HR. * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. 4.L 1 it t •a, r http://database.ul.comlcgi-binIXYVItemplatelLISEXT/1 FRAMElshowpage.html?name=B... 11 /5/2018 BXUV.U443 - Fire Resistanc ` Aings - ANSI/UL 263 Page 2 of 3 ALTERNATE CONSTRUCTION (SEE. ITEMS T 1. Studs — Channel shaped, 3-5/8 in. wide by 1-1/4 in. deep with 5/16 in. folded back return Flange legs. Fabricated from No. 20 MSG (0.0329 in., min. bare metal thickness) galvanized steel. Max stud spacing 24 in. OC. Studs to be cut 1 in. less than assembly height. 2. Floor and Ceiling Runners — (Not shown) — Channel shaped runners, 3-5/8 in. wide by 1-1/4 in. deep, fabricated from No. 20 MSG (0.0329 in., min. bare metal thickness) galvanized steel. Attached to Floor and ceiling with fasteners, 24 in. OC, max. 3. Cementitious Backer Units* — Board 1/2 or 5/8 in. thick, square edge, attached to studs with 1-5/8 in. long, Type S-12, corrosion -resistant wafer -head steel screws spaced 8 in. OC, joints covered with glass fiber mesh tape. UNITED STATES GYPSUM CO — Type DCB 4. Batts and Blankets* — Placed to fill interior of stud cavity, 3 in. min thickness. INDUSTRIAL INSULATION GROUP L L C — Type SAFB 3OHNS MANVILLE — Type SAFB ROCKWOOL — Type AFB THERMAFIBER INC — Type SAFB, SAFB FF 5. Bond Coat for Setting Tile — Latex modified Portland cement mortar or ANSI A136.1 Type I organic adhesive applied with a 1/4 in. square notched trowel. 6. Ceramic Tile — Tile, 1/4 in. thick, joints filled with grout. 7. Gypsum Board* — Base layer, 1/2 in. thick, applied vertically and attached with 1 in. long, Type S-12 steel screw, spaced 24 in. OC at joints and in field. Face layer, 1/2 in. thick, applied vertically with joints offset from base layer joints. Attached to studs with 1-5/8 in. long, Type S-12 steel screws, spaced 12 In. OC at the joint edges and in the field. ACADIA DRYWALL SUPPLIES LTD — Type C AMERICAN GYPSUM CO — Types AG-C. CERTAINTEED GYPSUM INC — Type C. CGC INC — Type C, IP-X2, IPC-AR or WRC. CONTINENTAL BUILDING PRODUCTS OPERATING CO, L L C — Type LGFC-C/A. GEORGIA-PACIFIC GYPSUM L L C — Types 5, DAPC, TG-C. http://database.ul.com/cgi-binIXYVItemplatelLISEXT/1 FRAMElshowpage.html?name--B... 11 /5/2018 BXUV.U443 - Fire Resistance Drtings - ANSI/UL 263 1, Page 3 of 3 NATIONAL GYPSUM CO — Types eXP-C, FSK-C, FSW-C, FSMR-C. PABCO BUILDING PRODUCTS L L C, DBA PABCO GYPSUM —Type PG-C. PANEL REY S A — Type PRC SAINT-GOBAIN GYPROC MIDDLE EAST FZE — Type Gyproc FireStop, Gyproc FireStop MR, Gyproc FireStop M2TECH, Gyproc FireStop ACTIV'Air, Gyproc RreStop MR ACTIV'Air, Gyproc FireStop 142TECH ACn%TAir THAI GYPSUM PRODUCTS PCL — Type C. UNITED STATES GYPSUM CO — Type C, IP-X2, IPC-AR or WRC. USG BORAL DRYWALL SFZ LLC — Type C USG MEXICO S A DE C V — Type C, IP-X2, IPC-AR or WRC. 7A. Gypsum Board* — (As an alternate to Item 7) — 5/8 in. thick. Installed as described in Item 7. NATIONAL GYPSUM CO —Type FSMR-C. UNITED STATES GYPSUM CO — Type ULIX 8. Joint Tape and Compound — Vinyl, dry or premixed joint compound, applied in two coats to joints and screw heads; paper tape, 21n. wide, embedded in first layer of compound over all joints. As an alternate, nominal 3/32 in. thick gypsum veneer plaster may be applied to the entire surface of Classifed veneer baseboard. Joints reinforced. 9. Vapor Permeable Water Barrier Sheathing Material — (Optional) — As required. 10. Water Barrier — (Optional — Not shown) — Commercial asphalt saturated and/or coated felt. * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. Last Updated on 2018-08-15 Ouestions7 Print this can Terms of Use Pane Too ©2018 UL LLC The appearance of a company's name or product In this database does not in itself assure that products so identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow -Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained In the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (flies) must be presented in their entirety and in a non -misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must Include a copyright notice in the following format: "© 2018 UL LLC". http://database.ul.com/cgi-binIXYVItemplatelLISEXT/1 FRAMElshowpage.html?name=B... 11/5/2018