Loading...
HomeMy WebLinkAboutSIGN SET UPF- z 0 I)z LL w 0 J J INDIVIDUAL INTERNALLY LED ILLUMINATED CHANNEL LETTER5 ON RA j N Fy GV LLI G�1 3 LLJ U w CD JA (11:STOIANTE ITALIAHO 72 in 25' FRONTAGE SCANNED BY St. Lucie County I I ,lilt IqH EACK F C)NT Glu. syr MCI, F-4FA� ALLOWABLE 516N AREA 5TOREFRONT = 25' X 15' = 525 5.F. 525 X 20% = 65 5.F. I/ 516N = 28" X 72" = 14 5.F. t/ "ONUALED FASTENERS ORA11ACHMENTS "E THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD T Fr8E PLANS A140 ALL PROPOSED "'101,:% ST. LUCIE C L._:: dUR JECT IQ ANY CORMC7IONS BUILDING C hLQUIREDBYFIELD ItSPECIO"S IHAT FORCOMN [.W UE NEC'ESUIV IN ORDER TO REVIEWED BY I6ilipLywirdALLAPPLIWUCODES. DATE_Illalts PLANS AND JOB TITLE CDKLEONES ADDRE55 FORTSTLUC,E OAPFIR VED r 4444 S.E. COMMERCE AVE. E� �p aau.�r...p.pptflum�e NOTE: ALL ARTWORK 6 COLORS MUST BE SIGNED OFF BEFORE ANY WORK 15 TO BEGW OAPPROVEDW/CHANGES 1 � STUART,FL.34997 772.220.7768 BgnalVtlmgnmin.lowntauwwnan areoryoM an opxtl.tne tl n Mo p.nk.xon IF EXACT COLORS ARE REQUIRED OR MORE DETAILS PLEASE NOTE. CUSTOMER 15 O NOT APPROVED flamingosiOns®aol.cam xprpnr tpanprpauaain •nryy a..�w. wrn mwi eN rM upn.uE wmhnaa u.m RESPON510LE FOR ANY CHANGES ONCE WORK BEGINS. RESUBMIT W/ CHANGES INDIV]DUAL'INTERNALLY LED ILLUMINATED CHANNEL LETTER5 ON RACEWAY Letters to be fabricated of .063 aluminum backs with .040 black returns. Interior of letters to be gloss white. Faces to be 3116" 7328 white acrylic with 1" black Gemini 2025 trimcaps. Lighting to be bright white Hanley led modules attached with 3M VHB tape. Power supples to be Hanley 120 / 12 v. 1.1a premium power supplies. Letters mounted to EMS aluminum extruded raceway minimum 4 per letter #8 tech screws. Raceway fabricated of .125 aluminum to meet UL standards. Backs have Inset track to accept 2' mounting clips. Clips to be spaced no more than 48" max. 1 top & 1 bottom with minimum 2 pair per raceway. Raceway painted to match wall section. UL Rated disconnect mounted to end of raceway Primary electrical feed in UL conduit connected to existing power supply to be provided. Wall section: Concrete Block MOUNTING METHOD TO BE 318' HARDWARE EMBEDMENT OF 2.6' (1) 20 amp 120V Circuit Req This sign is to be Installed in accordance with the requirements of Article 600 of the National Electrical Code. 1) Grounded and bonded per NEC 600.7/NEC 250 2) Existing branch circuit In compliance with NEC 600.5, not to exceed 20 amps 3) Sign is to be UL listed per NEC 600.3 4) UL disconnect switch per NEC 600.6- required per sign component before leaving manufacturer' 'For multiple signs, a disconnect is permitted but not required for each section 510N TO BE IN5TALLEO ACCORDING TO 2014 NEC (N.F.P.A. 70) 000.3 ULTIMATE WIND VELOCITY = 170 MPH RISK CATEGORY II EXP05URE "C" 4-.r-� 6th EDITION "2017 F13C" JOB TITLECORLEONE5 ADDRESS P51- 10H 44445.E.COMMERCE AVE JAME5 E. PAIT, P.E. PEG#25497 NOTE: ALL ARTWORK & COLORS MUST BE 51ONED OFF BEFORE ANY WORK 15 TO BEGIN 5TUARL FL.34997 122015.E. COLEY AVE. HOSE SOUND, FL 33455 IF EXACT COLORS ARE REQUIRED OR MORE DETAILS PLEASE NOTE. CUSTOMER L57722207377 PEBPON5113LE FOR ANY CHANGES ONCE WORK 13EGIN5. FAX 772 22 0 7768 PHONE 545 9553 FAX 545 9279