INDIVIDUAL INTERNALLY LED ILLUMINATED CHANNEL LETTER5 ON RA
j N
Fy GV
LLI G�1 3
LLJ U w
CD
JA (11:STOIANTE ITALIAHO
72 in
25' FRONTAGE
SCANNED
BY
St. Lucie County
I I ,lilt IqH EACK
F C)NT
Glu. syr
MCI,
F-4FA�
ALLOWABLE 516N AREA
5TOREFRONT = 25' X 15' =
525 5.F.
525 X 20% = 65 5.F. I/
516N = 28" X 72" = 14 5.F.
t/
"ONUALED FASTENERS ORA11ACHMENTS
"E THE RESPONSIBILITY OF THE
CONTRACTOR OF RECORD
T Fr8E PLANS A140 ALL PROPOSED "'101,:%
ST. LUCIE C
L._:: dUR JECT IQ ANY CORMC7IONS
BUILDING C
hLQUIREDBYFIELD ItSPECIO"S IHAT
FORCOMN
[.W UE NEC'ESUIV IN ORDER TO REVIEWED
BY
I6ilipLywirdALLAPPLIWUCODES. DATE_Illalts
PLANS AND
JOB TITLE CDKLEONES ADDRE55 FORTSTLUC,E
OAPFIR VED
r
4444 S.E. COMMERCE
AVE. E�
�p aau.�r...p.pptflum�e
NOTE: ALL ARTWORK 6 COLORS MUST BE SIGNED OFF BEFORE ANY WORK 15 TO BEGW
OAPPROVEDW/CHANGES
1 �
STUART,FL.34997
772.220.7768
BgnalVtlmgnmin.lowntauwwnan
areoryoM an opxtl.tne tl n Mo p.nk.xon
IF EXACT COLORS ARE REQUIRED OR MORE DETAILS PLEASE NOTE. CUSTOMER 15
O NOT APPROVED
flamingosiOns®aol.cam
xprpnr tpanprpauaain •nryy a..�w.
wrn mwi eN rM upn.uE wmhnaa u.m
RESPON510LE FOR ANY CHANGES ONCE WORK BEGINS.
RESUBMIT W/ CHANGES
INDIV]DUAL'INTERNALLY LED ILLUMINATED CHANNEL LETTER5 ON RACEWAY
Letters to be fabricated of .063 aluminum backs
with .040 black returns. Interior of letters to be
gloss white.
Faces to be 3116" 7328 white acrylic with 1"
black Gemini 2025 trimcaps.
Lighting to be bright white Hanley led modules
attached with 3M VHB tape. Power supples to be
Hanley 120 / 12 v. 1.1a premium power supplies.
Letters mounted to EMS aluminum extruded
raceway minimum 4 per letter #8 tech screws.
Raceway fabricated of .125 aluminum to meet
UL standards. Backs have Inset track to accept
2' mounting clips. Clips to be spaced no more
than 48" max. 1 top & 1 bottom with minimum 2
pair per raceway.
Raceway painted to match wall section.
UL Rated disconnect mounted to end of raceway
Primary electrical feed in UL conduit connected to
existing power supply to be provided.
Wall section: Concrete Block
MOUNTING METHOD TO BE 318' HARDWARE
EMBEDMENT OF 2.6'
(1) 20 amp 120V Circuit Req
This sign is to be Installed in accordance with
the requirements of Article 600 of the National
Electrical Code.
1) Grounded and bonded per NEC 600.7/NEC 250
2) Existing branch circuit In compliance with
NEC 600.5, not to exceed 20 amps
3) Sign is to be UL listed per NEC 600.3
4) UL disconnect switch per NEC 600.6- required per
sign component before leaving manufacturer'
'For multiple signs, a disconnect is permitted but
not required for each section
510N TO BE IN5TALLEO ACCORDING TO 2014 NEC (N.F.P.A. 70) 000.3
ULTIMATE WIND VELOCITY = 170 MPH
RISK CATEGORY II EXP05URE "C"
4-.r-� 6th EDITION "2017 F13C"
JOB TITLECORLEONE5 ADDRESS P51- 10H
44445.E.COMMERCE AVE JAME5 E. PAIT, P.E. PEG#25497
NOTE: ALL ARTWORK & COLORS MUST BE 51ONED OFF BEFORE ANY WORK 15 TO BEGIN 5TUARL FL.34997 122015.E. COLEY AVE. HOSE SOUND, FL 33455
IF EXACT COLORS ARE REQUIRED OR MORE DETAILS PLEASE NOTE. CUSTOMER L57722207377
PEBPON5113LE FOR ANY CHANGES ONCE WORK 13EGIN5. FAX 772 22 0 7768 PHONE 545 9553 FAX 545 9279