HomeMy WebLinkAboutREVIEW COMMENTSPlanning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462.2172 Fax:(772)462.6443 PROPERTY INFORMATION Address: 8000 S Us Hwy 1 - Td Bank City I State I Zip: Port St Lucie, FI 34952 Parcel#: 3414-501-1701-000/9 Zoning: CIS APPLICATION INFORMATION Permit Number: 1810-0465 Permit Type: COMMERCIAL RENOVATION CONTRACTOR INFORMATION Contractor Name: Edward F O'rourke Business Name: Ics Builders Inc Business Addr: 108 W 39Th St 14Th FI City / State / Zip: New York, Ny 10018 REVIEWS AND COMMENTS REVIEW COMMENTS Page 1 SCANNED Owner(s): BY Wynne Building Corp St. Lucie County Jurisdiction: SAINT LUCIE COUNTY Lot#: Block: 1 Stories: Automatic Sprinkler System? No Fax Number: 212-633-9427 Email: Eorourkk@lcsbuilders.Com Review Tvoe Status Reviewed By Date Started Date Comoleted Date Released DOCUMENTS MISSING PENDING Lydia Galbraith 11/5/2018 Comment: PLUMBING AND ELECTRICALSUB AGREEMENT. FRONT COUNTER REVIEW COMPLETE Audrey Humphrey 10/2212018 1012212018 Comment: PLANS EXAMINER ELECTRIC COMPLETE Walter Pride 11/912018 11/9/2018 111912018 Comment: - PLANS EXAMINER MECHANICAL COMPLETE Carl Peterson 11/1312018 12/1812018 12118/2018 Comment: PLANS EXAMINER PLUMBING COMPLETE Andy Wentz 11/9/2018 1211312018 1211312018 Comment: PLANS EXAMINER REVIEW COMPLETE William Durden 11/812018 12113/2018 1211312018 Comment: PLANS EXAMINER REVIEW INCOMPLETE William Durden 12/1812018 12/19/2018 Comment: PLEASE SUBMIT THE FIRE SPRINKLER PLAN SHOWING THE RELOCATION AND INSTALLATION OF THE FIRE SPRINKLERS. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. 12119/2018 Comment: TWO C/D'S OF THE PLANS ARE REQUIRED TO BE SUBMITTED. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Planning & Development Services Building & Code Regulation Division 2300 Vtrglnia Avenue Fort Pierce, FL 34982 Phone:(772(462.2172 Fax:(772)462.6443 REVIEW COMMENTS cvnuw ncnc�� �VIYIYLC 1 C Lyaia uamfdlth 11/5/2018 11/5/2018 1115/2018 Comment: Planning& Development Services Building & Code Regulation Division 2300 Virginla Avenue Fort Pierce, FL 34982 Phone:(772)462-2172 Fax:(772(462-6443 PROPERTY INFORMATION Address: 8000 S Us Hwy 1 - Td Bank City / State / Zip: Port St Lucie, FI 34952 Parcel#: 3414-501-1701-000/9 Zoning: CG APPLICATION INFORMATION Permit Number: 1810-0465 Permit Type: COMMERCIAL CONTRACTOR INFORMATION Contractor Name: Edward F O'rourke Business Name: Ics Builders Inc Business Addr: 108 W 39Th St 14Th City / State / Zip: New York, Ny 10018 REVIEW COMMENTS 1 Owner(s): Wynne Building Corp Jurisdiction: SAINT LUCIE COUNTY Lot#: Black: 1 Stories: Automatic Sprinkler System? No RECEIVED DEC - g Zpig Fax Number: 212-633-9427 Permitting Department Email: Eorourkk@lcsbuilders.Com St. Lucie County, FL Review Type S atus Reviewed By Date Started Date Completed Date Released DOCUMENTS MISSING PENDING Lydia Galbraith 111512018 Comment: PLUMBING AND ELECTRICAL SUB AGREEMENT. FRONT COUNTER REVIEW COMPLETE Audrey Humphrey 1012212018 10/2212018 Comment: PLANS EXAMINER ELECTRIC INCOMPLETE Walter Pride Comment: PLANS EXAMINER MECHANICAL INCOMPLETE Carl Peterson 1111312018 11/13/2018 Comment: PLEASE SHOW VENTILATION IN TOILET ROOMS IN ACCORDANCE WITH TABLE 403.3.1. OF THE FLORIDA MECHANCIAL CODE. PLANS EXAMINER PLUMBING I COt�_ MPLEUL Andy Wentz 11/912018 11/13/2018 Comment: NEED A HIGH/LOW DRINKING FOUNTAIN PER TABLE 403.1 FLORIDA PLUMBING CODE 6TH EDITION 11/13/2018 Comment: NEED A SERVICE SINK PER TABLE 403.1 FLORIDA PLUMBING CODE 6TH EDITION 11/1312018 Comment: BATHROOMS ARE REQUIRED TO HAVE HOT WATER PER 607.1 FLORIDA PLUMBING CODE 6TH EDITION PLANS EXAMINER REVIEW I GOM(_J P___ ,LETE� William Durden 11/8/2018 Comment: PLEASE SUBMIT A DETAIL FOR THE INSTALLATION OF THE NEW CONCRETE BOXES TO BE INSTALLED. 11/9/2018 WITH A DETAIL FOR THE CONCRETE REPAIR. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Comment: ROOM 117 DOES NOT MEET THE ACCESSIBILITY REQUIREMENTS OF CHAPTER 3, SECTION 3D4. PLEASE 11/9/2018 CORRECT AND RESUBMIT. 111912018 Comment: PLEASE NOTE ALL EXTERIOR SIGNAGE WILL NEED TO BE PERMITTED SEPARATELY. Planning & Development Services Building S Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462.2172 Fax:(772)462.6443 ZONING REVIEW Comment: REVIEW COMMENTS Page 2 COMPLETE Lydia Galbraith 11/512018 11/512018 11/512018 LU DEC, 0 6 ^018 ST. Lucie County, Permitting Planning 8 Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462.2172 Fax:(772(462.6443 PROPERTY INFORMATION Address: 8000 S Us Hwy 1 - Td Bank City I State / Zip: Port St Lucie, FI 34952 Parcel #: . 3414-501-1701-00019 REVIEW COMMENTS u Owner(s): Wynne Building Corp Jurisdiction: SAINT LUCIE COUNTY Zoning: CG Lot#: APPLICATION INFORMATION Permit Number: 1810-0465 Stories: Permit Type: COMMERCIAL RENOVATION CONTRACTOR INFORMATION Contractor Name: Edward F O'rourke Block: 1 Automatic Sprinkler System? No Fax Number: 212-633-9427 Business Name: Ics Builders Inc Business Addr: 108 W Email: Eorourkk@lcsbuilders.Com 39Th St 14Th FI City / State / Zip: New York, Ny 10018 REVIEWS AND COMMENTS Review Tvpe Status Reviewed By Date Started Date Completed Date Released DOCUMENTS MISSING PENDING - Lydia Galbraith 11/512018 Comment: PLUMBING AND ELECTRICAL SUB AGREEMENT. FRONT COUNTER REVIEW COMPLETE Audrey Humphrey 10/2212018 10/22/2018 Comment: PLANS EXAMINER ELECTRIC INCOMPLETE Walter Pride Comment: PLANS EXAMINER MECHANICAL INCOMPLETE Carl Peterson 11M3/2018 11/1312018 Comment: PLEASE SHOW VENTILATION IN TOILET ROOMS IN ACCORDANCE WITH TABLE 403.3.1. OF THE FLORIDA MECHANCIAL CODE. . _.PLANS EXAMINER PLUMBING INCOMPLETE Andy Wentz 11/912018 1111312018' Comment: NEED A HIGH/LOW DRINKING FOUNTAIN PER TABLE 403.1 FLORIDA PLUMBING CODE 6TH EDITION 11/1312018 Comment: NEED A SERVICE SINK PER TABLE 403.1 FLORIDA PLUMBING CODE 6TH EDITION 11/13I20'I8 Comment: BATHROOMS ARE REQUIRED TO HAVE HOT WATER PER 607.1 FLORIDA PLUMBING CODE 6TH EDITION PLANS EXAMINER REVIEW INCOMPLETE William Durden 111812018 11/9/2018 Comment: PLEASE SUBMIT A DETAIL FOR THE INSTALLATION OF THE NEW CONCRETE BOXES TO BE INSTALLED. WITH A DETAIL FOR THE CONCRETE REPAIR. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. 1119/2018 Comment: ROOM 117 DOES NOT MEET THE ACCESSIBILITY REQUIREMENTS OF CHAPTER 3, SECTION 304. PLEASE CORRECT AND RESUBMIT. 1119/2018 Comment: PLEASE NOTE ALL EXTERIOR SIGNAGE WILL NEED TO BE PERMITTED SEPARATELY. Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772(462.2172 Fax:(772)462-6443 REVIEW COMMENTS ZONING REVIEW COMPLETE Lydia Galbraith 11/512018 11/5/2018 11/612018 Comment: