HomeMy WebLinkAboutDESIGN CALCULATIONSti EasySeals easyseals.com DE51GN CALCULATION5 FOR MAVERICK BOAT GROUP WALL -MOUNTED SIGNS 4551 St Lucie Blvd — Port St Lucie GENERAL NOTES: 1, Design is in accordance with the Florida Building Code 61h Edition(2017) for use within and outside the High Velocity Hurricane Zone (HVHZI. 2. Wind loads have been calculated per the requirements ofASCE 7-10 as shown herein. 3. These engineering alculations pertain only to the structural integrity of those systems, components, and/or other construction explicitly specified herein and/or in accompanying engineering drawings. The existing host structure (if any) is assumed to be in good condition, capable of supporting the loaded system, subject to building department approval. No warranty, either expressed or implied, is contained herein. 4. System components shall be as noted herein. All references to named components and installation shall conform to manufacturer's or industry specifications as summarized herein. 5. Where site conditions deviate from those noted herein, revisions may be required or a separate site -specific engineering evaluation performed. 6. Aluminum components in contact with steel or embedded in concrete shall be protected as prescribed in the 2015 Aluminum Design Manual, Part 1. Steel components in contact with, but not encased in, concrete shall be mated, painted, or otherwise protected against corrosion. 7. Engineer seal affixed hereto validates structural design as shown only. Use of this specification by contractor, at. AI, indemnifies and saves harmless this engineer for all costs & damages including legal fees & apellate fees resulting from deviation from this design. 3200 N Federal Hwy, 42M Borg Ram., FL33432 Easy Seals .com Index: Pit 1 Cover Pg2 Wind Loads Pg3 AnchometLogo Pg4 Anchors at Letters EngiVeL i lbeal valid No.6 1812 2 �sft: i'r CTAT :.14:088� •'. ' ,; ChrisjleS t et! •RE t15382 Easy Se31s,.,,,H„tGe Auth N 31124 Page 1 EaWSeals CALCULATIONS FOR WALL -MOUNTED SIGNS ASCE 7-10 Design Wind Loads WALL -MOUNTED SIGNS Building Specs V= 160mph Baskwindspeed Exposure C Calculations a=9.5 3-secgustspeedpowerlaweponent S = 9D0' Nominal ht. of otmos. boundary layer Gcpi c 0 internol pressure coeff ASD Load Combo Coeff: 0.6 Kd= 0.85 Directionalityfacmr Krt= 1.0 Topographkfactor Tributary area A= SOsgk SIGN (EIGHT CENTER I (Zone 4) CORNER (Zone S) n x % 35 it 31.2 psf 39.7 psf 0.85 47.3 -1.10 -1.40 20 ft 33.2 psf 42.2 psf 0.90 50.2 -1.10 -1.40 25 ft 34.8 psf 44.2 psf 095 52.7 -1.10 -1.40 30ft 36.2 psf 0.98 54.7 -1.10 -1.40 .0ptf 47.5 psf 35 ft 37.3 psf 1.01 56.5 -1.10 -1A0 40 ft 39A psf 48.8 psf 1.04 58.1 -1.10 -1.40 4511 39.3 psf 50.1 psf 1.07 59.6 -1.10 -1.40 'Soft 40.2 psf 51.2 psf 1.09 60.9 -1.10 -1.40 55 it 41.0 psf 52.2 psf 1.12 62.2 -1.10 -1.40 60ft, 41.8 psf 53.2 psf 1.14 633 -1.10 -1.40 70 ft 35.3 psf 70.6 psf 1-17 65.4 -090' -1.80 soft 36.3 psf 72.6 psf 1.21 67.3 -0.90 -1.80 90ft 37.2 psf 74.5 psf 124 69.0 -0.90 -1.80 100 ft. 38.1 psf 76.1 psf 1.27 70.5 -0.90 -1.90 110ft 38.8 psf 77.7 psf 1.29 71.9 -0.90 -1.80 120ft 39.6 psf 79.1 psf 1.32 73.3 -0.90 -1.80 130 ft 40.2 psf 80.5 psf 1.34 74.5 -0.90 -1.80 140 ft 40.9 psf 81.7 psf 1.36 75.7 -0.90 -1-80 150 ft 41.5 psf 82.9 psf 138 76.8 -0.90 -1.80 175 ft' 42.8 psf 85.7 psf 1.42 79.3 -0.90 -1.90 200ft 44.2 psf 88.1 psf 1A6 81.6 -0.90 -1.80 250it 46.2 asf 92.3 psf 153 85.5 -090 -1.80 Page 2 .� EiC1WSea�ls CALCULATIONS FOR WALL -MOUNTED SIGNS Wall Sign Anchor Design Structure Dimensions & Loading Design wind pressure: P= 46.0 psi Sign type: Cabinet Sign size: A= _ 115.6 sgft (entirecabinet) Wall material: Metal Steel studs arestrusions/shapes Anchor type/size: 1 #8 SMS Ref: Min 18ga studs (gird 33) or 0.090" 6063-T6 Min Embedment: Full Minedgedist: 0.75" Min Spacing: 0.5" Anchor tensile capacity: Tcap= 99.9 lb (per anchor) Check Anchors for Pullout Total Reaction: Rt= 5314 lb ...=P•A (entireobinet) No. of anchors req'd: n= 53.2 total anchors _=Rt/mp Total anchors required: 54 total anchors balanced over cabinet OK, critical anchor option at logo shown. Use min (11) per stringer= (55) screws total. Fasten stringers to wall with (5) 3/8" thrubolts each = (25) total. Page 3 - i '`' EEd� SeQ[s CALCULATIONS FOR WALL -MOUNTED SIGNS �/ Wall Sign Anchor Design Structure Dimensions & Loading Design wind pressure: P = 46.0 psf Sign type: FChannel Letter Sign size: A= 36.0 sgft (per letter, critical) Wall material: Metal steel studs or extrusions/shapes Anchor type/size: 48-32 Bolt Ref: AAMA TIR-A9-1991, min 3/16" alum Min Embedment: Full Minedgedist: 1" Min Spacing: 1" Anchor tensile capacity: Tcap= 215.0 lb (peranchor) Check Anchors for Pullout Total Reaction: Fit = 1655 lb ...=P"A (per letter) No. of anchors req'd: n = 7.7 anchors per letter—=Rtlrap Total anchors required: 8 anchors per letter OK, critical letter size shown. Limit to min (6) studs per letter, bal.. Paged