HomeMy WebLinkAboutMISC LETTERz
Architectonic Inc
St. Lucie County
Planning & Development Services RECEIVED
Building & Code Regulation Division
2300 Virginia Ave, OCT 2 5 2018
Fort Pierce, FL 34982 SCANNED ST. Lucie county, Permitting
October 23, 2018 BY
St. Lucie County
RE: 702 S. Market Avenue
To Whom It May Concern:
Our office has performed design pressure calculations for the above referenced project and herby certify
that the proposed garage doors are in compliance with the 2017 Florida Building Code, 160 mph wind
zone, exposure "B", risk category II.
From Table 1609.3.1: V it= 160mph
V.d= 124mph
From Table 1609,7(1): (1) 30' x 10', 160 mph=+24.31/-27.3
(1) 12' x 10', 160 mph=+23.81/-26.4
From Table 1609,7(2): 20' mean roof height, exposure B=1.0
Required Design Pressures: -27.3
Product: Janus International Corp 26 ga. Series 3100 Door Assembly FL # 12765.3
Product Pressures: +36.0 & -41.0
806 Delaware Avenue
Fort Pierce, Florida 34950
Tel: 772 460 7751
Fax: 772 460 4244
www.architectonicinc.com