HomeMy WebLinkAboutWIND LOAD DESIGN PRESSURE CALCULATIONS�-FENGINEII I N G EXPRE Order (Ref) #: (43398-4517245370) Project Details: URBAN CONDO DOOR REPLACEMENT Contractor: J&G CARPENTRY, INC. 9600 S. OCEAN DRIVE, UNIT 1104 7030 S.W. 16TH COURT PEMBROKE JENSEN BEACH, ST LUCIE COUNTY, FL PINES, FL Subject: Wind Load Design Pressure Calculations (Components & Cladding) Site Information Building Classification: enclosed Wind Speed (V lt): 170 mph Exposure Category: d Roof Type: monoslope Roof Slope (0): 1.2 deg Mean Roof Height (h): 127.0 ft Min. Building Dimension (L): 94.0 ft Parapet 2: 3 feet? No General Calculation Directionality Factor (Kd): 0.85 Gust -Effect Factor (G): 0.85 Internal Pressure Coefficient (GCPi )' ±0.18 Topographical Factor (Kt): 1.0 Velocity Pressure Exposure Coefficient K 1.49 Velocity Pressure (qh): 93.94 psf End Zone (a): 9.4 ft ASD Method: P = 0.6w Mark Qt Y Elev,(/ft t _) Size', W x H' in ( �... Zone Shutter? Area`ft2 (.. ) K `(K'; z . A q 4z1(4.h).,, fGC P+. UGC, ,.,.:.P ��Pryre's`sures (psf MXe ,.-_..Qa.a. 1 (1) 96.0 36.0 x 80.0 4 No 20.0 1.42 89.47 0.90 -0.90 +58.5 / —60.9 ZSCA�Npn ( count 1. LUcl e LoUnty, Pgrmlttlnq NOTES: Design is In accordance with ASCE 7-10 (ASD method) and the Florida Building Code Sixth Edition (2017). Results \\ t' ' ' . " / // are not valid for use unless approved via original signature and raised engineer seal of a PE from Engineering Express. \\\ V�' {hTy 4 iSgd Engineer Results are based on contractor-supplled data and shall be field verified by others prior to use. Selection & installatlp o . •''SE •S i products shall be approved using these dimensions and pressures as verified by others: Note: For openings to be properly rated in Zone 4, no part of the opening shall be within 9.4 feet of any buildingcoiLt:r•'. Tt� Oct b r 25 8 This engineer has not field visited this location and if this cannot be clearly identified by others, the opening shall bQe: �GOrd n D' LLISLtFEE. evaluated prior to installation of any fenestration. All other information provided above Including mean roof he�ght' $ Ur building minimum dimensions, opening sizes, & other supporting data was provided by others. For definitions of�he above terms, visit EngineeringExpress.com/Wiki" A �� 160 SW 12TH AVENUE, SUITE 106, DEERFIELD BEACH, FLORIDA 33442 (43398-4517245370) PHONE: (954) 354-0660 — FAX: (954) 354-0443 AutoPrint ENGINEERING EXPRESS.COM PAGE 1 OF