EVALUATION REPORT
NEMO I etc.
Gerdflaxie qfAuthudearlon #3245S
353 Christian Street, Unit #13
OxFord, CT 06478
(203) 262-9245
CONSULT I CERTIFY
Polyglass USA, Inc. Evaluation Report P12060.02.09-R24
1111 West Newport Center Drive FLS2S9-R28
Deerfield Beach, FL 33442 Date of Issuance: 02/24/2009
(954)233-1230 Revision 24:02/24/Z018
SCOPE:
This Evaluation Report is Issued under Rule GIG20-3 and the applicable rules and regulations governing the use of
construction materials In the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E.
for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the e Edition (2017) Florida Building Code sections noted
herein.
DEsauvrioN. Pollyglass Roof Underlayments
UISELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. �
CONIIINUED COMPLIANCE: This Evaluation Report Is valid until such time as the named product(s) changes, the referenc I ad
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance Of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility lodation(s). NEMO I etc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMEur The Evaluation Report number preceded by the words "NEMOIL-tc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then It shall be done in its entirety. '
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for Inspection at thejoti site at the request of the Building Official.
This Evaluation Report consists of pages 3. through 14.
Prepared by:
S41i
Robert J.M. Nlemlnen, P.E. The famirnflesealappearing,vas authorized by Robert Nierninen,
10
.6
Florida Registration Na. 59166, Florida DCA ANF1 98 P.E. an oV24/2018. This does not same as an eleamnically
sIgneddocurnent.'
CEIDIFICAMON OF INDEPENDENCE:
1. N EMO I etc. does not have, nor does it Intend to acquire or will it acquire, a fi nanclal interest In any company man ufacturing, or
distributing products It evaluates.
2. NEMO I etc. Is not owned, operated or controlled by any company manufacturing or distributing products It evaluates.
3. Robert Nlerninen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing produ cts for
which the evaluation reports are being issued.
4. Robert Nleminen, P.E. does not have, nor will acquire, a financial Interest In any other entity Involved In the approval process of the
product.
S. This is a building code evaluation. Neither NEMOletc. nor Robert Nlemlnen, P.E. are, In any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specificallyfor that purpose.
ONEMOletc.
ROOFING COMPONMT EVALUATION:
1. SCOPE:
Product Category., Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Uncleylayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the
following sections of the & Edition (2017) Florida Building Code through testing in accordance with the following Standards.
Compliance Is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. SrANDARDS:
Section
Proper
Standard
year
1504.3.1
Wind Uplift
FM 4474
2011
15043.1
WindUplift
UL 1897
2012
1507.2.3/1507.Ll
Physical Properties
ASTM D226
20D9
1507.2A / 2507.3.1,1507.2-9.2
Physical Properties
ASTM D1970
201S
1507.3.3
Physical Properties
FRSA/TRI April 2012
2012
1507.11.2
Physical Properties
ASTM D6154
2011
1507.11.2
Physical Properties
ASTM D6222
2021
TAS110
Accelerated Weathering
ASTM 04798
2011
3. REFERENCES:
Entity
Examination
Reference
Date
FM Approvals (TST 1867)
Wind Uplift
3004091
01/12/2000
Pill M75878)
Physical Properties
PRIOMI
04/08/2002
PRI (MS878)
Physical Properties
PUSA-005-02-01
03AI/2002
PRI(TSTSHIS)
Physical Properties
PUSA-93-02-01
22/23/2002
FRI (TST 5978)
Physical Properties
PUSA-013-02-02
12/23/2002
PRI tTST 5878)
Physical Properties
PUSA-013-02-03
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-018-02-01
07114/2003
PRI W 5978)
Physical Properties
FUSA-028-02-01
07/13/20(15
PRI iT!rr5878)
Physical Properties
PUSA-033-02-02
01/12/2005
PRI (TST 5878)
Physical Properties
PUSA-035-02-01
09/29/2005
PRI rM 51378)
Physical Properties
FUSAASS-02-02
12/10/2007
PRI (TST 5878)
Physical Properties
PUSA-061-02-02
01/28/2008
PRI M7 5978)
Physical Properties
PUSA-076-02-02
02/22/2DOS
PRI (TST 5878)
Physical Properties
PUSA-083-02-M
04/14/2008
PRI (TST S878)
Physical Properties
PUSA-DR-02-01
07/29/2009
MTI M 2509)
Physical Properties
JX20H7A
04/01/2008
MTI (TST 2508)
Physical Properties
RX14EBA
alpg/2009
ERD (TST 6D49)
Physical Properties
11752.09.99-1
02/08/2000
ERD (TST 6049)
Wind Uplift
11757.08.01-1
09/23/2001
ERD (TST 6049)
Wind Uplift
11776.06.02
01/16/2003
ERD 6049)
Physical Properties
02200.07.03
07A4/2003
ERD 6049)
Wind Uplift
P1740.01.0
01/04/2007
ERD (TST GD49)
Physical Properties
PS120.04.07-1
04IIIA007
ERD CTST 6049)
Wind Uplift
P9260.03.09
03/21POOB
ERD (TST 6D49)
Physical Properties
1,13450M.09
08/13/2009
ERD (TST 6049)
Wind Uplift
P30M.11.09-113.
IWO/2009
ERD (TST 6049)
Physical Properties
P:11030.12.03�1
12/30/2009
ERD W 6049)
Wind Uplift
P12030.21.09-2
W30/2009
ERD (TST 6949)
Physical Properties
P12030.11�,09-3
IM012009
ERD (TST 6049)
Physical Properties
P33360.06.10
06/25/2010
ERD W 6049)
Physical Properties
P33370.03.11
03/02/2022
ERD(IST6049)
Physical Properties
P33370.04.11
04/26/2021
ERB W 6049)
Physical Properties
P373DO.20.12
ID119/2011
NEMO err, uc. Evaluation Report P12050.OZ09-R24
MQkoW CfAuMarantron #324S5 dr- EDITION (2017) FBC NON,-HVHZ EVALUATION FL52594US
Polvglasa RoGfUndedayrMantS, (954) 233-1230 Revision 24:01/24/2018
Page 2 of 14
Entft
ERDCW6049)
ERD ffSr 6049)
ERD (W 6049)
ERD fW 6049)
ERDfIV6049)
ERD (TST 6049)
ERD (TSr 6049)
ERD M 5049)
ERD (TST 6049)
ERD (TS7 6049)
ERD (TST 6049)
ERD (TSr 6049)
ERD (M 6049)
ERDCW6049)
ERD(W6049)
ERD (W 6049)
ERD CM 6049)
ERD UST 60491
ERD(TSr6G49)
ERD (TSr 60491
ERD (TST 60491
ERD (T5r 6049)
ERD W 6049)
ERD (W 5049)
ERD(IST6049)
ERD(I'ST6049)
ERD (TST 6049)
ERD (W 6049)
ERD (TST 6049)
]CC-ES(EVL2396)
Miami -Dade (CER 1592)
Polyglass USA
Polyglass USA
Polyglass USA
UL, U.C. (QUA96251
Examination
Physical Properties
Physical Properties
Physical Properties
Wnd Uplift
Physical Properties
Wnd Uplift
Wind Uplift
Wind Uplift
Wind Uplift
)VInd Uplift
Physical ProperUes
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
physical Properties
Physical Properties
Physical Properties
Physical Properties
Wind Uplift
Physical Properties
Wind Uplift
Physical Properties
Physloal Properties
Physical Properties
IBC Compliance
HVI4ZCompliance
ManufacturingAffidavit
P/L Affidavit
Materials Affidavit
ClualityControl
Reference
P40390.08.22-1
P4039MOS.n-2
C41420.09.12-3
P3968MO3.23
P45370.04.13
P1738.02.07-R2
31757.04.01-1-Rl
P41630.08.13
P11751.05.03-RI
P217BL11.03-RI
P4527MG5.14
6020.07.14-1
6020.09.14-2
6020.09.14-3
6020.09.IA-4
6020.09.14-5
602D.09.14-6
P46520.10.24
P43290.10.14
PLYG-SC7550.03.25
P40390.04.15
P44360.10.24-RI
PLYG-SC8080.0&15-1
PLYG-SC8905.05,16-1
PLYG-SC8080.07.16
PLYG-SC120nlO.26
PLYG-SC13040.12.16
PLYG-SCII900.03.17
PLYG-SC1221S.08.17
ESR-1697
NOA 24-0717.08
Products Current
MuIeHlde Cross I%
PolystIck SA Compound
Service Confirmation
4. PRODUCT DESCRIPTION:
picat IV Fa
4.1.2 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet.
4.L2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet
4.1.3 Polyglass 62 Base Is a fiberglass-reinfomed, asphaltic base sheet.
4.2.4 PolVglass APIP Base is a fiberglass -reinforced, APP modified bitumen base sheet
ONEW[Ojilift.
11ate
5_/o_r,/2o12
08IU712012
09/11/2012
03/04/2013
04/26/2013
04/29/2013
04/30/2013
08/06/2013
1:V26/2013
11/26/203.3
05/12/2014
09/08/2014
03/08/2014
09/0812014
09/08/2014
09/08/2014
D9/0812014
10/03/2014
10/17/2014
03/24/2015
04/03/2015
05/18/2015
05/20/201S
0!5/17/2016
CY711612016
20/12/2011.6
22/27/2016
OBAD/2017
08/08/2027
21/01AG24
Oln2/2015
02/18/2009
03/0212008
08/2W2012
Exp. 10/05/2018
i- , __ .- .." ofIng membrane, glass
4.2.1 Pollystick MTS or Polystick MTS PUU5 Is a nominal 60-mll thick rubberized asphalt waterPrO
fiber reinforced, surfaced with polyclefinic film surface; meets FRSA/rRI April 2012.
4.2.2 Polystick IR-Xe Is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an
aggregate surface; meets ASTIVI C1970.
4.2.3 Polystick TU Plus is a nominal 80-mll thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a
polyester fabric surface, meets ASTM D1970 and FRSAITRI April 2012.
Evaluation Report P12060.02.09-M
NEMO EM Uc. FL5ZS54W
Q,t&�,fAWWk0W-#3ZM eH EDITION (2017) FHC NoN_HVHZ EVALUATION
PoWj= Raul Underlaymenta. (954) L33-IM R�vlslon 24-.02/24/2US
Page 3 of Z4
ONEMOJetc.
4.2.4 PoWck TU P Is a nominal 230-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester
reinforced, with a granular surface; meets FIRSA/TRI April 2012.
4.2.5 Polystick TU Max Is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 gfM2 polyester
fabric surface; meets ASTM D1970 and FRSAfTRI April 2012.
4,2.6 Poleax SAP, Polyflex SAP FR, mule -Hide SA-APP Cap Sheet and Mule-Hlde SA-APP Cap Sheet (FR) are polyester
reinforced, APP modified bitumen cap sheets, meet FRSA/TRI April 2012.
4.2.7 Polystick Dual Prc� Is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyester fabric surface; meets ASTM D1970.
4.2.8 Polystick Tile Prdm Is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyester fabric surface; meets ASTIVI D 1970 and FRSAfrRI April 2012.
4.2.9 Poliistick MU-X is a nominal 54-rioll thick. dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polypropylene film surface; meets AC289 and physical requirements of ASTM D1970 (See Section
5.8).
4.3.2 Elestaflex G TU is a polyester reinforced, modified bitumen tile underlayment composed of a sand -surfaced SBS
modified bitumen back -side and granule -surfaced APP modified bitumen topside. Elastollex G TU is for use as an
alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the 'Single Ply System" from FRSAfrRI April
2012 (04-12) beneath mechanically fastened tile roof systems or Hot Asphalt applied "Cap Sheet' In the 'Two, Ply
System"from FRSA[rRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems.
4.3.2 Elastoflex S6 G and Elastoflex S6 6 FR are polyester reinforced, SBS modified bitumen cap sheets� meetASTM D6264.
Elastoflex S6 G and Elastaflex S6 6 FIR are for use as an alternate to 'Mineral Surface Roll Roofing" (ASTM DG380,
Class M) In the "Single Ply System" from FRSA/TR1 April 2012 (04-12) beneath mechanically fastened tile roof systems.
Elastaflex S6 G Is for use as an alternate to Hot Asphalt applied "Cap Sheer in the 'Two Ply Systencr from FRSA/rRI
April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Elastoflex 56 G FR Is for use as an
alternate to Hot Asphalt applied "Cap Sheer In the 'Two Ply System" from FRSA/TR1 April, 2012 (04-12) beneath
mechanically fastened tile roof systems.
4.3.3 Polyflex G and Polyflex: 6 FR are polyester reinforced, APP modified bitumen cap sheets; meet ASTM D6222.
Polyflex: G Is for use as an alternate to Heat Applied "Cap Sheer In the "Two Ply System" from FRSA/TRI April 2012
(0442) beneath mechanically fastened or adhered tile roof systems. Polyflex: 6 FR is for use as an alternate to Heat
Applied mCap Sheer in the qWo Ply Systerno from FRSA/rRI April 2012 (04-12) beneath mechanically fastened tile
roof systems.
S. LIMTrATIONS.
5.2 -Fhis Is a building code evaluation. Neither NEM01 etc. nor Robert Nieminen, P.E. are, In any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically forthat Purpose.
5.2 -rhis Evaluation Report Is not for use In the HVH7_
5.3 Rre Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
NEMO ETC. LLr_ Eval uatlon Report P12060-02-09-VA
ongiinne, of A W a dwtlan #32455 EDM ON (21317) FBC NON-RVHZ EVAWATIGN FL5259-M
P,Ngfm Roof undseloymenion, (954) 233-1230 Revision 24:01/2412018
I Page 4 of 14
I-,
5.5 Aflowable Roof Covers:
OONEMOjetc.
'TA
Underlayment
AsphaltShinglas
Nall -On Ylle
Foa�Onflle
Metal
1
WoodShakes
95 n es
Slate
Elastobase
Yes
Yes
Yes
Yes
Yes
Yes
Elastobase P
Yes
Yes
Yes
Yes
Yes
Yes
polvillass G2 Base
No
Yes
Yes
No
No
No
Polyglass APP Base
No
Yes
(�e5mnin2.ply�aq
Yes
(amshenln24V�M)
No
No
No
Folystick Mrs or MTS PLUS
Yes
Yes-
No
Yes
Yes
Yes
Polystick IR-Xe
Yes
No
NO
No
Yes
Yes
PolystIckTU P
No
Yes
Yes (Sees.5.1)
No
No
No
Polystick TU Plus
Yes
Yes
Yes (sees.5.1)
Yes
Yes
Yes
Polystickyu Max
No
Yes
Yes (Seess.%)—
Yes
No
No
FojVStlCk Dual Pro
Yes
No
No
Yes
Yes
Yes
PolystickTilePm
Yes
Yes
Yes (SMS.5.1)
Yes
Yes
Yes
PoWckMU-X
Yes
No
No
Yes
Yes
Yes
Elastuff"SfiG
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes I
ElaftflexS6 G FR
Yes
Yes
No
yes
Yes
Elastoftex G TU
Yes
Yes
Yes (See Ss.1)—
yes
Yes
Polyflex G
Yes
Yes (See 5-9.1)
No
yes
Yes
Polyflex G FR
Yes
Yes
No
No
Yes
Yes
Polyflax SAP orSAP FR
Yes
Yes
Yes (See S.S.2)
No
Yes
Yes
Mut&Hlde SA-APP Cap Sheet
I orSA-APP Cap Sheet (FR)
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
5.5.1 OFoam-On Tile" Is limited to use of the follovAng Approved tile adhesives / underlayment combinations.
yE
Adhesive
Florida Product
Underlayments
Approind
DAP Foam Touch 'n Seal Stormlland Roof
FL14506
Polystick TU Plus, Polystirk TU Max
TlleAdhefive
DowTileliond�
FL22525
PolystickTU F, Polystick TU Plus, Polyflex SAP or Tile Pro
Polystick TU P, PoWck TU Plus, Polystick TU Max, Polystick Tile Pro,
1CP Adhesives PolysetO AH-160
FL6332
Elastoflex G TU, Elastaflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR,
Mule -Hide SA-APP Cap Sheet or Mule,Hlde SA-APP Cap Sheet (FR)
kTi
PolystickTI) P, PolystickTU Plus, PolystickTU M2x, Polystic HePro,
FICP Adh:�W,, Plyet- RTA-1
FI.6776
Elastoflex G TU, Elastaflex S5 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR,
Mu le-HIde SA�APP Ca p Sheet or Mule-Hlde SA-APP Cap Sheet (FRI
Refer to Tile manufacturer's of Adhesive manufacturer's Florida product Approvalfor Overturning Mom ant Resistance Parftrnzanc�
Evaluation Report P12060.02.09-R24
NEMOETr,LLC. FL5259-R28
naro7anc of Authvrft� 03VZ Sn' EDITION (2017) FEC NON41VHZ EVALUATION
Polyglass Roof Underlaynterds; (954) 233-1230 RevIslon 24; 01/24/2018
Page 5 of 14
ON-EMO I etc.
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck.,
Polystick (all variations), Dual Pro, Tile Pro, Palyflex SAP or SAP FR, Mule-HIdeSA-APP Cap Sheet or SA-APP Cap Sheet
(FR) self -adhered to:
> New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing
plywood; New or exlstln& unprimed OSB; ASTM 041 primed OSS; Southern Yellow Pine, ASTMI D41 primed
Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods 'ZIP System" Panels
(designed and Installed to meet wind loads for project).
Note: Polyglass does not require priming of new or existing plywood or QSB sheathing. New or existing plywood or
OSS sheathing should hi cleaned of all dirt and debris prior to appikation of Polystick membranes.
Elastaflex G TU� Elastoilex S6 G or Elastoflex S6 G FR In hot asphalt to:
> ASTM D41 primed structural concrete.
Palyflex G or Polyflex G FR torch -applied to:
> ASTM D41 primed structural concrete.
5.6.2 Bord-tia-Insulation
Polystick (all vadations), Polyflex SAP or SAP FR. Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered
to:
> ASTM C1299, Type 11, Class I polylsocyanurate or Type V polylsocyanurate-composite Insulation; Dens Deck
DuraGuard; Dens Deck Prime, or SECUROCK Gypsum -Fiber Roof Board.
Elastaflex G TU, Elastoflex S6 G or Elastaflex S6 G FR in hut asphalt to:
> Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board.
Polyflex G or Polyflex G FR tDrch-applied to:
> ASTM D41 primed structural concrete, Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board.
For Installation under mechanically attached prepared roof coverings, Insulation shall be attached per minimum
requirements of the prepared roof covering manufacturees Product Approval. For installations under foam -on tile
systems, insulation attachment shall be designed by a qualified design professional and installed based an testing of
the Insulation/underlayment system In accordance with FBC Section 1504-3.1.
5.6-3 Bond to Mechanically Attached Base Lave :
Poiystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or
Tile Pro self -adhered to:
> ASTM D226, Type I or 11 felt; Elastabase; Elastobase P or Mule -Hide Nall Base.
Elastaflex G TU, Elastoflex 56 G or Elastitiflex S6 6 FR In hot asphalt to;
> ASTM D226, Type I or 11 felt; Elastobase; Elastobase P, Mule -Hide Nall Base or Polyalass G2 Base.
Polyflex G or Polyflex G FR torch -applied to:
> Elastobase, Elastobase P, Mule -Hide Nall Base, Polyglass G2 Base or Palyglass APP Base.
For Installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For Installations under foam -on tile systems, base layer shall be attached per minimum
requirements of FRSA(TRI April 2012 (04-12), Appendix A, Table 1, or as listed In Section 5.6.4 herein, or as tested In
accordance with FBC Section 1504.3.1.
NEMO ETCp U.C. Enlustion Report P120150.02119-1124
en EDMON p=7) FOC NCI%-HVHZ EVAWATION FLW594tz8
Polygan Roof Underlayments; (954) 233-1230 ReVISIM 24.' OV2412018
Page6of24
ONEMOletc.
5.6A Wind Resistance for Under'layment Systems In Foam -On Tile Applications: FRSA/TR1 Apdl 2012 (04-22) does not
address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment
forms part of the load -path. : The following wind uplift limitations apply to underlayment systems that are not
addressed In FRSAJTRI April 2012 (04-12) and are used In foam -on file applications. Maximum Design Pressure Is the
result of testing for wind load resistance based on allowable wlind loads, and reflects the ultimate passing pressure
divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TR1 April 2012 (64-
12), Appendlic A, Table 1A or FEC 1609 for determination of design wind loads.
#1 Maximum Design Pressure = -90 v
Decka Min. 15/32-inch plywood to meet project requirements to satisfaction afAuthority Having Jurisdiction.
Primer: None
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Potystick TU Plus, Polystick TU Max, Poyflex SAP, Polyflex SAP FR, Mule -Hide SAAPP Cap Sheet and
Mule -Hide SA�APP Cap Sheet (FRI, self -adhered.
#2 Maximum Deslan Pressure = -97.5 psf
Derla- Min. 15/32-inch plywood to meet priiject requirements to satisfaction of Authority Having Jurisdiction.
Primer: PGIGO at ASYM D41
Base Ply: (Optional) Polystick MTS or Poly5dck MTS PLUS, self -adhered.
Undedaymeft Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x
IN' ring shank nails through 32 ga., 1-5/8' diameter tin cap s spaced 12-Inch o.c.
#3 Maid in um Design Pressu re = -105 psl�
Deck., Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: wB_a0G0 -
Base Ply: (Optional) Po[Mck NITS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Po"ickTU Max, Polyflex SAP, Polyflex SAP FR. Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), saff-adhered and back -nailed within the selvedge -edge side laps using 12 ga. x
IYO ringshank nails through 32 ga., 1-5/9" diametertin caps spaced 12-inch o.c.
#4 Maximum Design Pressure= -135
Deck: Min. 15/324nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer (Optional) PG100 or ASTM DQL
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self-adhened.
JoInts: Min. 4-inch wide strips of Elastoflex SAV over all plywood Joints.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU May, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), salf-ad heriel.
#5 Maximum Design Pressure = -315
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having J urisdiction.
Primer: PG100 or ASTM D41
Base ply'. (Optional) Polystick MTS or PolystIck MTS PLUS, seif-adhered.
Underlayment: Polystick TU P, Polystick TU Plus, polystick TU Max� Tile Pro, Polyllex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap
Sheet and Mule-Hilde SA-APP Cap Sheet (FR), self�dhered
#6 Maximum Design Pressure= -622.5 a
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer. PG1GGorASTM D41
Underlayment: Elastaflex G TU or Elastallex SIS G, applied In full mopping of hot asphalt or Polyflex G, torch-appled.
#7 Maximum Design Pressure w -30.0 Psf*
Decla, Min. 15/324nch OSB to meet project requirements to satisfaction of Authority HavingJurisdiction.
Base Sheet: Elastobase or Mule -Hide Nall Base (pololm top surface)
Fasteners: 11 Be. x IjS-Inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply; (Optional) Polystick MTS or Polystick NITS PLUS, self -adhered.
Underlaymem: Polystick TU P, PolystickTU Plus, Polystick TU May, PoWex SAP, Polyflax SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
NEMO ETC, UJC. Enluatton Report P12060.02.09-1124
en EDMON (ZU7) FOC NON-HVHZ EvALuAnoN FLWS9-R28
Potiglass Roof Undarlayments, (SS4) 233-1230 Rmlelon 24; 01/2412018
Page7 of 14
ONEMOJetc.
#8 Maximum Design Pressure = -37.5 psf*
Deck: Min. 25/32-inch plywood to meet project requirements to satisfaction of Authority HavinfiJurlsdiction.
Base Sheet Elastobase Dr Mule-Hice Nall Base (poly -film top surface)
Fasteners: 11 Be. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: G-Inch oc. at the 3-Inch wide side laps and 6-Inch o.c. at two (2) equally spaced staggered center raw&
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyffm SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
M ule-Hide SA-APP Cap Sheet (Flij, self-achered.
#9 Maximum Design Pressure= -37.5 psf*
Deck: Min. 19/32-lnch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (1) ortwo (2) layers ASTM D226, Type 11 felt
Fasteners: 11 ga. x 1.25-inch long x 1-Inch head diameter round metal cap nails
Spacing: 6-inch ox. at the 3-inch wide side laps and 22-Inch. o.Q at two (2) equally spaced staggered center romis.
Underlayment: Elastaflex 6 TU or Elastollex S6 6, applied In full mapping of hot asphalt
#10 Maximum Design Pressure = -45 psf*
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Hwing J urisclIction.
Base Sheet: One (1) layer ASTM D226, Type 11 felt
Fasteners: 11 Be. x 3.254nch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/9-Inch diameter tin caps
Spacing: 4Anch o.c. at the 24nch wide side laps and 44nch c.c. at two (2) equally spaced staggered center ram.
Base Ply: (Optional; for use with self -ad hering underlayment only) Polystick MTS or Polystick MTS PLUS, seIII-adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Maut, Polyflex SAP, Polyfim SAP FR, Mul"Ide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), saff-adhered or Elastoflex G TU, applied In full mopping of hot asp halt
#11 Maximum Design Pressure = -4S PSP
Deck: Min. 19/32-Inch plywood to meet project requirements to satisfaction of Authority HavIng.luriscilt-tion.
Base Sheet: Two (2) layers ASTM D226, Type I I felt
Fasteners: 11 ga. x 1.25-Inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-Inch diameter tin caps
Spacing: 9-inch c.c. at the 2-Inch wide side laps and 94nch c.c. at two (2) equally spaced staggered center ram.
Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS or Polystick MTS PLUS, selfadhered.
Underlaymerrh Polystick TU P, Polystid: TU Plus, Polystick TU May, Polyllm SAP, Polyll" SAP FR, Mule-HIde SAAPP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self-adfiered or Elastoflu 6 TU or Elastolleii: S6 G, applied In full mapping of hat
asphalt.
#12 Mindmurn Design Pressure= -45
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Havingiurisdiction.
Base Sheet: Elastabase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface fo r torch -applied cap)
Fasteners: Sunpleii MAXX Cap Fasteners
Spacing,. 94nch o.c. at the 2-inch wide side laps and 18-Inch ci.� attwo (2) equally spaced staggered center rows.
Underlayment Elastaflex G TU or ElaStoflex S6 G, applied in full mopping of hot asphalt or Polyfi� G, torch-applIed.
#13 Maximum Design Pressure = -S2.5 Ps
Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority HaVing Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hat�asphalt or torch -applied cap or polVAInn surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch D.C. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally Spaced staggered center ram.
Underlayment: Elastallex G TU or ElastcAl" S6 G, applied In fu 11 mopping afhat asphalt or POlyflaX G, torch-applled.
#14 Maximum Design Pressure = -52.S P
Deck: Min. 25/32-inch plywood to meet project requIrementsto satisfaction of Authority Havingludsdiction.
BaseSheet: Elastoba� " Mule -Hide Nall Base (pol"Im top surface)
Fasteners: Simplex Original Cap Nails
Spacing: 6-Inch mc. at the 3-inch wide side laps and liminch D.C. at four (4) equally spaced staggered center rows.
Base Ply., (Optional) Potystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, PoWck'(U Max, Polyflex SAP, PoWex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule-Hicle SA-APP Cap Sheet (FR), self -adhered.
NEMO ETCv LLC. Ewluatlon Report P12060.02.09-1124
Urt*M CfAUthadnitbn 032455 EDIMON (20171 FBC NON-MVHZ EVALUATION FL5299-R28
Polyglass Roof Underlayments; (9S4) ZMAMO Revision 24: 01/2412018
Page 8 of 14
ONEMOletc.
#15 Maximum Design Pressure= -52.5 p
Deck: Min. 15/324nch plywood to met project requirementsto satisfaction of Authority HavingJurisdiction.
Sam Sheet., Efastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface fortorch-applied cap)
Fasteners: Simpilm Original Cap Nails
Spacing: 6-Inch o.c. at the 3-Incti wide side laps and Vnch cic. at four (4) equally spaced staggered center rows.
Underlaymenn Elastoflex G TU or Elestaftex S6 G, applied in full mopping of hot asphalt or POW" 6, torch-appued.
#16 Maximum Design Pressure = .60
Deck: Min. 29/32-Inch plywood to meet project req uIrements to milsfactlon of Authority Having Jurisdiction.
Base Sheet; Elastobase (sanded top surface for hat -asphalt or torich-applied cap or poly -film surface for torchapplied cap)
Fasteners: 11 Be. x 1.25-Inch long x 3/8-Inch head dianneter annular ring shank roofing nalls at I-S/8-Inch diameter tin caps
SpadW. 8-Inch o.c. at the 4-inch wide side laps and B-Tnch ci.c. at three (3) equally spaced staggered center rows.
Undarlayment: Elastofiex G TU or Elastaflex 56 G, applied In full mopping of hat asphalt or Polyflex G, torch -applied.
#27 Maximum Design Pressure = -60 p
Deck. Min. 19/32-inch plywood to meet project requirementsto satisfaction of Authority Having Jurisdiction.
Base Sheet: Elambase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Rocifidip with OMG Flat Bottom Metal Plates
Spacing: 22-Inch oc. at the 4-Inch wide side laps and 12-Inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex 6 TU or Elastaflex 56 6, applied In full moppil ng of hot asphalt or Polyflex Gtorch-appiled.
#28 Maximum Design Pressure = -67.5
Decla Min. 15/32-inch plywood to meet project req uIrements to satisfaction of Authority Having J urlsdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requim me of torcli-qpplied undadayment)
Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: B-Inch oc. at the 4�lrich wl de side laps and 84nch or- at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex IS TU or Elastafflex S6 G, applied in full mapping of hat asphalt or torch -applied or Polyflex 6, torch -
applied.
#19 Maximum Design Pressure = -75 P
Deda Min. 25/32-Inch plywood to meet project requirements to satisfaction of Authority Having.lurlsdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Sue frequires use of tonch-applied undedsYment)
Fasteners: Delifast #14 with Delclast Hex Plates, OMG #14 HD with DIVIG r Galvalume Steel Plates, OMG Rociftrip #14 with
OIVIG Flat Bottom Plates (AccuTmc), Trufast HD with Trufast 3-Inch Insulation Plates or Simplex MA)O( Cap
Fasteners
Spacing: 204nch a.c. at the 44nch wide side laps and 104nch o.c. atthree (3) equally spaced staggered cerder raw&
Underlayment: Elastaflex G TO or Elastofim S6 G, applied in full mopping of hat asphalt or torch -applied or Polyflex G, torch -
applied.
#20 Maximum Design Pressure = -90 0
Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastabase (sanded top surface for hat -asphalt or torch-appiled cap or poly -film surface for tDrch-upplied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-Inch a.c. at the 2-Inch wide side laps and GaInch o.c. at two (2) equally spaced staggered center rows.
Underlaymem: Elastciflex G TU or Elastaflex S6 G, applied In fu 11 mopping of hat asphalt or Polyflex G, torch -applied.
#21 Maximum Design Pressure = -90
Deck: Min. IS/BZ-Inch plywood.to meet pirciJeCtreqUirennentSt011athifaction of Authority Hwingiurisdiction.
Base Sheet: Elastabase (sanded top surface for hot -asphalt or torch -applied cap or polohn surface for torch -applied cap)
Fasteners: DMG #12 Standard Roofilrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing: &inch a.c. atthe 4-Inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Unclerlayment:- Elastoffax G TU or Elastaflex S6 G, applied In full mapping of hat asphalt or Polyflex G, torch -applied.
#22 Maximum Design Pressure = -90 P
Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sancledtop surface)
Fasteners: Trufast #12 DP orTrubst#14 HD with Trufast 3' Metal InsuMan Plates
Spacing: 6-Inch a.c. at the 44nch Vida side laps and 6-lnch o.c. at three (3) equally spaced staggered center rOw&
Underlayment: Elastoflex IS TU or Elastoflex S6 G, applied In full mopping of hat asphalt
NEMOEMLLC. Evaluation Report P12060.02.09-1124
Certftte qfAudwrWilan #3240 e EDIMON PU7) FBC NGN4KVMZ EVALUATION FL=59-HZB
Polygbss Rod Underlayinents, 1954) 233-IM Revision 24-.02124/2019
Page9ofldl
ONEMOJetc�
#23 Maximum Design Pressure= -90
Deck: Min. 25/32-Inch plywood to meet project requirements to 5atisfactl6n of Authority Having Jurisdiction.
Base Sheet Polyglass G2 Base or Polyglass APP Base (requires use of torch-iippiled undedayment)
Fasteners. Deldast #14 with Dekfast Hex plates, OMG #14 HD with OMG 30 Galvalume Steel Plates, OMG RociliBrip #14 with
OMG Flat Bottom Plates (Accurrac), Trufast HD with Trufast 3-Inch Insulation Plates or Simplex MA)(X Cap
Fasteners
Spacing; 9-Inch mc. at the 4-Inch wide side laps and 9-Inch o.c. at four (4) equally spaced staggered center rows.
underlayment: Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hat asphalt or ttirch-applied or Polyflex G, torch -
applied.
#24 Maximum Design Pressu re = -97.5 v
Deck: Min. 29/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet; Elastobase or Mule�Hlde Nail Base (poly -film top surface)
Fasteners: 11 go. x =54nch x 3/8-Inch head diameter annular ring shank roofing nails at 1-5/8-Inch diameter tin caps
Spacing: 44nch o.c. at the 4-Inch wide side laps and 4-Inch o.c. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polysdck MTS or Polystick MTS PWS, self -adhered.
Underlayment: PoWck TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule-HWe SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#25 Maxiimu in Design Pressure = -105 p
Deck: Min. 15/32-Inch plywood to meet project requireme nts to satisfaction of Authority Having Jurisdiction.
Base Sheet: Ele3tobase (sanded top so rface for hotasphalt or torch -applied cap or poly -film surface for torch -a pplied cap)
Fasteners: Simplex IMAXX Ca p Fasteners
Spacing: i5-Inch o.c. at the 2-Inch wide side laps and Vinch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastollex 6 TU or Elastoflex 56 G, applied in full mopping of hat asphalt or Polyflex G, torch-appiled.
#26 Maximum Design Pressure = -112.5 p
Deck: Min. 19/82-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-HIde Nail Base (poly -film top surface)
Fasteners: 11 Ca. x 1.25-inch x 3/8-Inch head diameter annular ring shank roafing nails at I-5/8-Inch diametertincaps
Spacing: 6-Inch oc at the 4-Inch wide side laps and 6-Inch oc. at four (4) equally spaced staggered center mws�
Primer. PG100 or ASTM D41 primer at all tin -caps
Base Ply: Polystick MYS or PolystIck MTS PWS, self -adhered
Underlayment: Polystick TU P, PolystickrU Plus, Polystick TU May, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self�dhered.
#27 Maximum Design Presisure = -120
Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot-asphaft or torch -applied cap or pGly-film surface fortorch-applied cap)
Fasteners: OMG #12 Standard RcofgrIp or OMG #14 Heavy Duty with OMG 30 Round Metal Plates or OMS Flat Bottom Metal
plates
Spacing* 64nch o.c. at the 4-Inch wide side laps and 6-Inch o.c. at five (S) equally spaced staggered center rows.
Underlayment: Elastaflex G TU or Elastollex SS G, applied In full mopping of hat asphalt or Polyflex G, torcWpplled.
#28 Maximum Design Pressure = -120 PsE
Deck: Min. 25/32-inch plywood to meet project requirementsto satisfaction of Authority HavingJurisdiction.
BaseSheet; Elestobase (sanded top surface)
Fasteners: Trufast #12 DP or Truiast#14 HD with Trufast 3' Metal [mutation Plates
Spacing. 6-Inch o.c. at thet-inch wide side laps and G-Inch o.c. at five (5) equally spaced staggered center rows.
Underlayment: Elastoflex 6 TU or Elastoflex S6 G, applied in full mopping of hat asphalt
5.6.4.1 All other dlrect-cleck� adhered Polyglass underlayment systems beneath foam -on tIle systems carry a Maximum
Design Pressure of -45 jisf.
NEMOEMLLC- Ewluation Report P12060.02.09-R24
Q,UftCM OfA uftd=VM 0M EDMON (2027) FOC WON-HVHZEVAWATION R525"28
po[V&ss Roof Underfaipments, (954) 233-2230 Revision 24-.01/24/201B
Page 10 of 14
ONEMOjetc.
5.6.4.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed
that required under FRSA/TRl April 2022 (04-12), Appendix A, Table IA.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design
pressure date rmined In accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment densitty
designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are
ANSI/SPRI WDI, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 3.17. Assemblies marked
with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January
2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30-days
after installation.
PoWick IR-Xe or Polystick MU-X shall not be left exposed for longer than 90-days after Installation.
Polystlick MTS, MTS PLUS, TIJ P. TU Plus, TU Max, Dual Pro, Tile Pro or Elastaflex: G TU shall not he left exposed for
longerthan 180-days after Installation.
Polyflex SAP or SAP FR, or Mule-Hlde SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure
limitation, unless the prepared roof covering Is to be adhesive -set tile, In which case the maximum exposure Is 30
days.
Elastoflex S6 G or Elastoflex S6 G FR or Polyflex G or Polyflex G FR does not have an exposure limitation, unless the
prepared roof covering Is to be adhesive -set tile (Elastoflex S6 G or Polyflex G only), In which case the mindmum
exposure is 180 days.
5.8 Polystildc MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226
roofing felt In a cry condition, tested at standard laboratory conditions. Agreement between purchaser and seller, as
set forth In Section 4.3, Note 1 of ASTM D3.970-2$, should be established as to slip resistance.
5.9 Tile Sllppaae Limitations (FRSA/TRI April 2012 (04-121):
When loading roof tiles on the iinderlayment In direct -deck fife assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
*WPAISA
Underfainnent
'rile Profile
Staging Method
Maximum Slope
EIastoflexGTU
Flat
2"lle stack
7:12
Lugged
&-tile stack IS over 2)
6:12
Elasioflex� G or SG 6 Fit
Flat or Lugged
&tile stack (4 over 2)
4:12
Powck MTS or MTS PLUS
Flat
&tHe stack (4 over 2)
5:12
Lugged
6-tile stack (4over 2)
4:12
PolystickTile Pro
Flat or Lugged
6-tile stack (4 over 2)
7:12
PolystickTU Max
Flat
6-tile suck (4 over 2) or 3Z-tile stack
7:12
Lugged
6-tile suck (4over2)
7:22
Lugged
10-tile stack
6:12
PalystickTU P
Flat
6-tile stack (4 over 2)
6;22
Lugged
6-dle stack (4 over 2)
4:12
PolystickTU Plus
flat or Lugged
Ftfle stack (4 over 2)
7:12
Flat or Lugged
10-tile stack
6:22
!j1,,V,1MGOr 2 1
Flat or Lugged
6-tile stack (4 over 2)
4:12
Po exi P YSA P FR
Flat or Lugged
I &tile stack (41 over 2)
1 4:12 1
NEMO M LLC- e%mluatlon Repartft=60.02.09-R24
EDITION (2017) FOC NONMVHZ EVALUAMON FLSM-R28
PoVgI= Roaf Undmlaymentr (954) 233-U30 ReAsIon 24:01124/2018
Page 22 of 14
ONEMOjeft.
6. INSIALLAnow
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published Installation requirements
subjecittothe Limitations setforth in Section 5 herein and the specifies noted below.
6.2 Re -fasten any loose decking panels, and checkfor protruding nail heads. Sweep the substrate thoroughlyto remove
any dust and debris prior to application, and prime the substrate (If applicable).
Shall be Installed in compliance with the codified requirements for ASTM D226, Type 11 underlayment hi FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
Elastabase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Pailystick, Polyflex: SAP, Polyflex SA
P FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FIR), selfadhered, Elastollex G TU, Mastoflex S6 G, or
Elastoflex S6 6 FR in hot asphalt or Polyflex: 6 or Polyflex 6 FR, torch applied. Roof cover limitations are those are
those associated with the top -layer underlayment as set forth in Table 1,
6.3.2 Tile Applications:
Elastobase, Elastobase P or Mule-Hlde Nail Base are limited to use as a mechanically attached base sheet in theTwo
Ply System" from FRSA/TRI April 2012 (04-12). Reference Is made to Table I and Section SAA herein, coupled with
FRS" April 2012 (04-1Z) Installation Manual.
&4 DW 0 AV or: pcil� 'A ekS'AP 1W SAP Fit
TU TV M*. To
""W
�'fJA 440SA-APPOpr5be� z t' -:77
ku" ule z,, .' .,
6.4.1 Shall be Installed In compliance with the codified requirements for ASTIVI D1970 (except Polystick TU P) underlayment
6.4.2
In FBC Table 1507.1.1 for the type of prepared roof covering to be installed.
Direct -to -Deck with Mechanically Fastened Roof Covers:
All self -adhering materials, with the exception of Polvstick TLI Plus, Polyflex SAP or SAP FIR and MuIL-Hide SA-APP
Cap Sheet or SA-APP Cap Sheet (FR) should be badc-nalled in selvage edge seam In accordance with Polyglass / Mule -
Hide back nailing guidelines. Nails shall be corrosion resistant, 22 gauge ring -shank type with a minimum 2-Inch
diameter metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TLI Plus should be back -
,nailed using the above noted fasteners and spacing, In area marked "nail area, area Para clavar" on the face of
membrane. The head lap membrane Is to cover the area being back -nailed.
All sea[4ap seams (selvage lops) must be
firmly railed with a minimum 28 lb. hand
roller to ensure full contact and adhesion.
For Dual Pro and Tile Pro, align the edge of
the top sheet to the end of the glue pattern
(the sheet will overlap the fabric). LM
View at Ovelap Seam of awl Pro and 7118 Im
All over -fabric and over -granule end -laps shall have a 64nch wide, uniform layer of Palyplus SO Premium Modified
Wet/Dry Cement or Polyglass P6500 Modified Cement applied In between the application of the lap.
Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys,
or exposed roof to wall details
NEMOETr,LLr, Ewluation Repon P12060.02.09-1124
EDITION (=7) FSC NON4MHZ EVALUATION FLS239-R28
Polinglass Roof Underlaymentse (51S41233-V30 ReV4*laft 24:01/2412018
Page 12 of 14
ONEMOletc.
Repair of Pollystick membranes is to be accomplished by applying Polyplus SO Premium Modified Wet/Dry Cement or
Polyglass P6500 Modified Cement to the area In need of repair, followed by a minimum 6 x 6 inch patch of the
Polystick material of like kind, set and hand rolled In place over the repair area. Patch laps, If needed, sheff be
Installed In a water shedding manner.
All Polystick membranes shall be Installed to ensure full contact with approved substrates. Polyglass requires a
minimum of 404b weighted -roller or, on steep slopes, use of it stiff broom with approximately.40-lbs of load applied
for the field membrane. Hand rcille� are acceptable for rolling of patches, laps (min. 28 lb roller) or small areas of the
roof that are not accessible to a large roller or broom.
6.4.3 Tile Applications (not allowed for Pblystick Dual Pro, IR-Xe or Pahartick W"):
Reference Is made to FRSA/TRi April Z012 (04-12) Installation Manual and Table I herein, using the Instructions
noted above as a guideline.
For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base
Sheet fastening shall be not less than FRSA/TRl April 2012 (04-12), Table L
Far adh esive-set tile applications, refer to Section 3.6.4 herein.
6.4A Two (2) Ply Underlayment Systems:
Polystick MYS or MTS PLUS followed by PoWck MTS, M73 PLILIS, TU P, TU Plus, TU Max, Tile Pro, MLI-X or Polyflex
.SAP Is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with
the top -layer material. This Is not a requirement but is allowable if a 2-ply underlayment system is desired.
Palystick MTS or MTS PLUS followed by Polystick TU P, TU Plus, TU Max, Tile Pro or Polyflex SAP Is allowable for use
under foam -on tile systems. Limits of use are those associated with the top -layer material. This is not a requirement,
but Is allowable If a 2-ply underlaVment system is desired.
6.5.1 Elastuflex 6 TU, Elastaflex SS G or Elastuflex S6 6 FR shall be installed In compliance with current PolUlass published
Installation requirements. For,use In tile applications:
• Elastoflex 6 TU is for use as an alternate to "Mineral Surface Roll Roofing' (ASTM D6380, Class M) In the 'Single
Ply System" from FRSAITRI April 2012 (04-12) beneath mechanically fastened tile roof systems orthe Hot Asphalt
applied "Cap Sheer in the 'rwo Ply Systerrr from FRSA/TRl April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
• Mastuflex: S5 6 is for use as an alternate to 'Mineral Surface Roll Roofine(ASTM D6380, Class M) In the �Slngle Ply
System" from FRWTRl April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied ftCap Sheer In the �Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
• Eastoillex S6 G FR Is for use as an alternate to "Mineral Surface Roll Roofing' (ASTM D6380, Class M) in the "Single
Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheer in the 'rwo Ply System' from FRSA/TFU April 2012 (04-22) beneath mechanically fastened tile
roof systems.
6.5.2 For hot -asphalt -applications, Elastaflex G TU, Elastoflex SIS 6 or Elastaflex SS G FR shall be fully asphalt -applied to the
substrates noted In Section 5.6. Side laps shall be minimum 3-Inch and end4aps minimum 6-Inch wide, aff-set
minimum 3 feet from course to course. Side and end laps shall be fully adhered In a complete mopping of hot asphalt
with asphalt extending approximately 3/8-inch beyond the lap edge.
Polyflex G or Palyflex G FR shall be Installed In compliance with current Polyglass published Installation requirements.
For use In Via applications:
v� Polyflex G Is for use as an alternate to the, Heat Applied 'Cap Sheer In the "Two Ply System" from FRSA/TRI April
2032 (04-12) beneath mechanically fastened or adhered tile roof systems (Base Sheet limited per 5.6-3).
0' Polyflex G FR Is for use as an alternate to the Heat Applied "Cap Sheet' In the 'Two Ply System' from FRSA/TRI
April 2012 (04-3.2) beneath mechanically fastened tile roof systems (Base Sheet Limited per 5.6.3).
NEW M LLC. Ewluation Report P12060.02A39-R24
ceptlikoft CfAUWo*abnA32455 IEDMON CM27) FBC NON-KVKZ EVALUAMON FLS25!6R28
PoVsiaw R90 Underlaymenb; (954) 233-1230 Reyislan 24:01/24/2018
Page 23 of 14
ONEMOjetc.
6.6.2 Polyflex 6 or Polyfilex 6 FR shall he fully torch -applied to the substrates noted In Section 5.6. Side laps shall be
minimum 34nch and end -laps minimum 6-Inch wide, off -set minimum 3 feet from course to course. Side and end
laps shall be fully heat -welded and inspected to ensure minimum 3/8-Inch flow of modified compound beyond the lap
edge.
6.7 Tile Stagink,
6.7.1 Tile shall be loaded and staged Ina manner that prevents tile slippage and/or damage to the underiayment Referto
Table 2 herein, and Polyglass published requirements for tile staging.
6.7.2 Battens and/or Counter�battens, as required by the tile manufacturer and FRSA/TRJ April 2012 (04-12) must be used
on all roof slopes greater then 7:12. Precautions should be taken as needed, such as the use of battens or nall-
boards, to prevent tile sliding and/or damage to the underlayment during the loading process.
6.7.3 Polyglass specifies the minimum cure time after Installation of self -adhering membranes and before loading of
rotifing tiles Is forty-eight (48) hours.
7. BUILDING PERMIT REQUIREMENTS!
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. 61620-3 GA requirements. The following
plants have qualified products under their respective physical properties specifications.
77777777
_i�rnley, NV, Hazleton, PA & Writer Haven, FL
ASTM D1970
Palystick MU-X
Hazleton, PA
M-D 13-0004
Elastoilex G TU
Hazleton, PA & Winter Haven, FL
ASTM D1970
Polvstick IR-)(e
ASTM D2970 & FRSAtrRI April 2032
Po[Vst1ckTU Plus
ASTM D1970 & FRWMI April 2022
PoilystIck TU Max
Tuscaloosa, AL
ASTM D4601, Type 11
Polyglass G2 Base
Yfinter Haven, FL
ASTM D226 (physicals)
Elastobase, Elastobase P
ASTM D6509
Polynla� APP Bai;e
FRSA/Ml April 2012
Polystck MTS, Polvsfl k MTS PLUS
FRSA/TR1 April 2012
PolystckTU P
FRSAITRI April 2012
Polyfleoc SAP, PoWex SAP Fit
ASTM D1970
Polystick Dual Pro
ASTM D1970 & FRSA)TRI April 2012
PoIvsUck.Tle Pro
ASTM D6164
Elastoftex SIS, Elastofiex S6 G Fit
ASTM D6222
PoWex G, Poilyflex G FR
9. QUALITY ASSURANCE ENTiTY:
LIL, LLC — QUA9625; (314) 578-3406, k.chancellor@us.ul.com
- END OF EVALUATION REPORT -