HomeMy WebLinkAboutEVALUATION REPORTSCANNED By St. Lucie County ENGINEER EVAUJATE TEST EVALUATION REPORT NEMO I etc. Gerdflaxie qfAuthudearlon #3245S 353 Christian Street, Unit #13 OxFord, CT 06478 (203) 262-9245 CONSULT I CERTIFY Polyglass USA, Inc. Evaluation Report P12060.02.09-R24 1111 West Newport Center Drive FLS2S9-R28 Deerfield Beach, FL 33442 Date of Issuance: 02/24/2009 (954)233-1230 Revision 24:02/24/Z018 SCOPE: This Evaluation Report is Issued under Rule GIG20-3 and the applicable rules and regulations governing the use of construction materials In the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the e Edition (2017) Florida Building Code sections noted herein. DEsauvrioN. Pollyglass Roof Underlayments UISELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. � CONIIINUED COMPLIANCE: This Evaluation Report Is valid until such time as the named product(s) changes, the referenc I ad Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance Of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility lodation(s). NEMO I etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMEur The Evaluation Report number preceded by the words "NEMOIL-tc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then It shall be done in its entirety. ' INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for Inspection at thejoti site at the request of the Building Official. This Evaluation Report consists of pages 3. through 14. Prepared by: S41i Robert J.M. Nlemlnen, P.E. The famirnflesealappearing,vas authorized by Robert Nierninen, 10 .6 Florida Registration Na. 59166, Florida DCA ANF1 98 P.E. an oV24/2018. This does not same as an eleamnically sIgneddocurnent.' CEIDIFICAMON OF INDEPENDENCE: 1. N EMO I etc. does not have, nor does it Intend to acquire or will it acquire, a fi nanclal interest In any company man ufacturing, or distributing products It evaluates. 2. NEMO I etc. Is not owned, operated or controlled by any company manufacturing or distributing products It evaluates. 3. Robert Nlerninen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing produ cts for which the evaluation reports are being issued. 4. Robert Nleminen, P.E. does not have, nor will acquire, a financial Interest In any other entity Involved In the approval process of the product. S. This is a building code evaluation. Neither NEMOletc. nor Robert Nlemlnen, P.E. are, In any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specificallyfor that purpose. ONEMOletc. ROOFING COMPONMT EVALUATION: 1. SCOPE: Product Category., Roofing Sub -Category: Underlayment Compliance Statement: Roof Uncleylayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the & Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance Is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. SrANDARDS: Section Proper Standard year 1504.3.1 Wind Uplift FM 4474 2011 15043.1 WindUplift UL 1897 2012 1507.2.3/1507.Ll Physical Properties ASTM D226 20D9 1507.2A / 2507.3.1,1507.2-9.2 Physical Properties ASTM D1970 201S 1507.3.3 Physical Properties FRSA/TRI April 2012 2012 1507.11.2 Physical Properties ASTM D6154 2011 1507.11.2 Physical Properties ASTM D6222 2021 TAS110 Accelerated Weathering ASTM 04798 2011 3. REFERENCES: Entity Examination Reference Date FM Approvals (TST 1867) Wind Uplift 3004091 01/12/2000 Pill M75878) Physical Properties PRIOMI 04/08/2002 PRI (MS878) Physical Properties PUSA-005-02-01 03AI/2002 PRI(TSTSHIS) Physical Properties PUSA-93-02-01 22/23/2002 FRI (TST 5978) Physical Properties PUSA-013-02-02 12/23/2002 PRI tTST 5878) Physical Properties PUSA-013-02-03 12/23/2002 PRI (TST 5878) Physical Properties PUSA-018-02-01 07114/2003 PRI W 5978) Physical Properties FUSA-028-02-01 07/13/20(15 PRI iT!rr5878) Physical Properties PUSA-033-02-02 01/12/2005 PRI (TST 5878) Physical Properties PUSA-035-02-01 09/29/2005 PRI rM 51378) Physical Properties FUSAASS-02-02 12/10/2007 PRI (TST 5878) Physical Properties PUSA-061-02-02 01/28/2008 PRI M7 5978) Physical Properties PUSA-076-02-02 02/22/2DOS PRI (TST 5878) Physical Properties PUSA-083-02-M 04/14/2008 PRI (TST S878) Physical Properties PUSA-DR-02-01 07/29/2009 MTI M 2509) Physical Properties JX20H7A 04/01/2008 MTI (TST 2508) Physical Properties RX14EBA alpg/2009 ERD (TST 6D49) Physical Properties 11752.09.99-1 02/08/2000 ERD (TST 6049) Wind Uplift 11757.08.01-1 09/23/2001 ERD (TST 6049) Wind Uplift 11776.06.02 01/16/2003 ERD 6049) Physical Properties 02200.07.03 07A4/2003 ERD 6049) Wind Uplift P1740.01.0 01/04/2007 ERD (TST GD49) Physical Properties PS120.04.07-1 04IIIA007 ERD CTST 6049) Wind Uplift P9260.03.09 03/21POOB ERD (TST 6D49) Physical Properties 1,13450M.09 08/13/2009 ERD (TST 6049) Wind Uplift P30M.11.09-113. IWO/2009 ERD (TST 6049) Physical Properties P:11030.12.03�1 12/30/2009 ERD W 6049) Wind Uplift P12030.21.09-2 W30/2009 ERD (TST 6949) Physical Properties P12030.11�,09-3 IM012009 ERD (TST 6049) Physical Properties P33360.06.10 06/25/2010 ERD W 6049) Physical Properties P33370.03.11 03/02/2022 ERD(IST6049) Physical Properties P33370.04.11 04/26/2021 ERB W 6049) Physical Properties P373DO.20.12 ID119/2011 NEMO err, uc. Evaluation Report P12050.OZ09-R24 MQkoW CfAuMarantron #324S5 dr- EDITION (2017) FBC NON,-HVHZ EVALUATION FL52594US Polvglasa RoGfUndedayrMantS, (954) 233-1230 Revision 24:01/24/2018 Page 2 of 14 Entft ERDCW6049) ERD ffSr 6049) ERD (W 6049) ERD fW 6049) ERDfIV6049) ERD (TST 6049) ERD (TSr 6049) ERD M 5049) ERD (TST 6049) ERD (TS7 6049) ERD (TST 6049) ERD (TSr 6049) ERD (M 6049) ERDCW6049) ERD(W6049) ERD (W 6049) ERD CM 6049) ERD UST 60491 ERD(TSr6G49) ERD (TSr 60491 ERD (TST 60491 ERD (T5r 6049) ERD W 6049) ERD (W 5049) ERD(IST6049) ERD(I'ST6049) ERD (TST 6049) ERD (W 6049) ERD (TST 6049) ]CC-ES(EVL2396) Miami -Dade (CER 1592) Polyglass USA Polyglass USA Polyglass USA UL, U.C. (QUA96251 Examination Physical Properties Physical Properties Physical Properties Wnd Uplift Physical Properties Wnd Uplift Wind Uplift Wind Uplift Wind Uplift )VInd Uplift Physical ProperUes Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties physical Properties Physical Properties Physical Properties Physical Properties Wind Uplift Physical Properties Wind Uplift Physical Properties Physloal Properties Physical Properties IBC Compliance HVI4ZCompliance ManufacturingAffidavit P/L Affidavit Materials Affidavit ClualityControl Reference P40390.08.22-1 P4039MOS.n-2 C41420.09.12-3 P3968MO3.23 P45370.04.13 P1738.02.07-R2 31757.04.01-1-Rl P41630.08.13 P11751.05.03-RI P217BL11.03-RI P4527MG5.14 6020.07.14-1 6020.09.14-2 6020.09.14-3 6020.09.IA-4 6020.09.14-5 602D.09.14-6 P46520.10.24 P43290.10.14 PLYG-SC7550.03.25 P40390.04.15 P44360.10.24-RI PLYG-SC8080.0&15-1 PLYG-SC8905.05,16-1 PLYG-SC8080.07.16 PLYG-SC120nlO.26 PLYG-SC13040.12.16 PLYG-SCII900.03.17 PLYG-SC1221S.08.17 ESR-1697 NOA 24-0717.08 Products Current MuIe­Hlde Cross I% PolystIck SA Compound Service Confirmation 4. PRODUCT DESCRIPTION: picat IV Fa 4.1.2 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet. 4.L2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet 4.1.3 Polyglass 62 Base Is a fiberglass-reinfomed, asphaltic base sheet. 4.2.4 PolVglass APIP Base is a fiberglass -reinforced, APP modified bitumen base sheet ONEW[Ojilift. 11ate 5_/o_r,/2o12 08IU712012 09/11/2012 03/04/2013 04/26/2013 04/29/2013 04/30/2013 08/06/2013 1:V26/2013 11/26/203.3 05/12/2014 09/08/2014 03/08/2014 09/0812014 09/08/2014 09/08/2014 D9/0812014 10/03/2014 10/17/2014 03/24/2015 04/03/2015 05/18/2015 05/20/201S 0!5/17/2016 CY711612016 20/12/2011.6 22/27/2016 OBAD/2017 08/08/2027 21/01AG24 Oln2/2015 02/18/2009 03/0212008 08/2W2012 Exp. 10/05/2018 i- , __ .- .." ofIng membrane, glass 4.2.1 Pollystick MTS or Polystick MTS PUU5 Is a nominal 60-mll thick rubberized asphalt waterPrO fiber reinforced, surfaced with polyclefinic film surface; meets FRSA/rRI April 2012. 4.2.2 Polystick IR-Xe Is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an aggregate surface; meets ASTIVI C1970. 4.2.3 Polystick TU Plus is a nominal 80-mll thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a polyester fabric surface, meets ASTM D1970 and FRSAITRI April 2012. Evaluation Report P12060.02.09-M NEMO EM Uc. FL5ZS54W Q,t&�,fAWWk0W-#3ZM eH EDITION (2017) FHC NoN_HVHZ EVALUATION PoWj= Raul Underlaymenta. (954) L33-IM R�vlslon 24-.02/24/2US Page 3 of Z4 ONEMOJetc. 4.2.4 PoWck TU P Is a nominal 230-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester reinforced, with a granular surface; meets FIRSA/TRI April 2012. 4.2.5 Polystick TU Max Is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 gfM2 polyester fabric surface; meets ASTM D1970 and FRSAfTRI April 2012. 4,2.6 Poleax SAP, Polyflex SAP FR, mule -Hide SA-APP Cap Sheet and Mule-Hlde SA-APP Cap Sheet (FR) are polyester reinforced, APP modified bitumen cap sheets, meet FRSA/TRI April 2012. 4.2.7 Polystick Dual Prc� Is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface; meets ASTM D1970. 4.2.8 Polystick Tile Prdm Is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface; meets ASTIVI D 1970 and FRSAfrRI April 2012. 4.2.9 Poliistick MU-X is a nominal 54-rioll thick. dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polypropylene film surface; meets AC289 and physical requirements of ASTM D1970 (See Section 5.8). 4.3.2 Elestaflex G TU is a polyester reinforced, modified bitumen tile underlayment composed of a sand -surfaced SBS modified bitumen back -side and granule -surfaced APP modified bitumen topside. Elastollex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the 'Single Ply System" from FRSAfrRI April 2012 (04-12) beneath mechanically fastened tile roof systems or Hot Asphalt applied "Cap Sheet' In the 'Two, Ply System"from FRSA[rRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. 4.3.2 Elastoflex S6 G and Elastoflex S6 6 FR are polyester reinforced, SBS modified bitumen cap sheets� meetASTM D6264. Elastoflex S6 G and Elastaflex S6 6 FIR are for use as an alternate to 'Mineral Surface Roll Roofing" (ASTM DG380, Class M) In the "Single Ply System" from FRSA/TR1 April 2012 (04-12) beneath mechanically fastened tile roof systems. Elastaflex S6 G Is for use as an alternate to Hot Asphalt applied "Cap Sheer in the 'Two Ply Systencr from FRSA/rRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Elastoflex 56 G FR Is for use as an alternate to Hot Asphalt applied "Cap Sheer In the 'Two Ply System" from FRSA/TR1 April, 2012 (04-12) beneath mechanically fastened tile roof systems. 4.3.3 Polyflex G and Polyflex: 6 FR are polyester reinforced, APP modified bitumen cap sheets; meet ASTM D6222. Polyflex: G Is for use as an alternate to Heat Applied "Cap Sheer In the "Two Ply System" from FRSA/TRI April 2012 (0442) beneath mechanically fastened or adhered tile roof systems. Polyflex: 6 FR is for use as an alternate to Heat Applied mCap Sheer in the qWo Ply Systerno from FRSA/rRI April 2012 (04-12) beneath mechanically fastened tile roof systems. S. LIMTrATIONS. 5.2 -Fhis Is a building code evaluation. Neither NEM01 etc. nor Robert Nieminen, P.E. are, In any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically forthat Purpose. 5.2 -rhis Evaluation Report Is not for use In the HVH7_ 5.3 Rre Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. NEMO ETC. LLr_ Eval uatlon Report P12060-02-09-VA ongiinne, of A W a dwtlan #32455 EDM ON (21317) FBC NON-RVHZ EVAWATIGN FL5259-M P,Ngfm Roof undseloymenion, (954) 233-1230 Revision 24:01/2412018 I Page 4 of 14 I-, 5.5 Aflowable Roof Covers: OONEMOjetc. 'TA Underlayment AsphaltShinglas Nall -On Ylle Foa�Onflle Metal 1 WoodShakes 95 n es Slate Elastobase Yes Yes Yes Yes Yes Yes Elastobase P Yes Yes Yes Yes Yes Yes polvillass G2 Base No Yes Yes No No No Polyglass APP Base No Yes (�e5mnin2.ply�aq Yes (amshenln24V�M) No No No Folystick Mrs or MTS PLUS Yes Yes- No Yes Yes Yes Polystick IR-Xe Yes No NO No Yes Yes PolystIckTU P No Yes Yes (Sees.5.1) No No No Polystick TU Plus Yes Yes Yes (sees.5.1) Yes Yes Yes Polystickyu Max No Yes Yes (Seess.%)— Yes No No FojVStlCk Dual Pro Yes No No Yes Yes Yes PolystickTilePm Yes Yes Yes (SMS.5.1) Yes Yes Yes PoWckMU-X Yes No No Yes Yes Yes Elastuff"SfiG Yes Yes Yes (See 5.5.1) No Yes Yes I ElaftflexS6 G FR Yes Yes No yes Yes Elastoftex G TU Yes Yes Yes (See Ss.1)— yes Yes Polyflex G Yes Yes (See 5-9.1) No yes Yes Polyflex G FR Yes Yes No No Yes Yes Polyflax SAP orSAP FR Yes Yes Yes (See S.S.2) No Yes Yes Mut&Hlde SA-APP Cap Sheet I orSA-APP Cap Sheet (FR) Yes Yes Yes (See 5.5.1) No Yes Yes 5.5.1 OFoam-On Tile" Is limited to use of the follovAng Approved tile adhesives / underlayment combinations. yE Adhesive Florida Product Underlayments Approind DAP Foam Touch 'n Seal Stormlland Roof FL14506 Polystick TU Plus, Polystirk TU Max TlleAdhefive DowTileliond� FL22525 PolystickTU F, Polystick TU Plus, Polyflex SAP or Tile Pro Polystick TU P, PoWck TU Plus, Polystick TU Max, Polystick Tile Pro, 1CP Adhesives PolysetO AH-160 FL6332 Elastoflex G TU, Elastaflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule,Hlde SA-APP Cap Sheet (FR) kTi PolystickTI) P, PolystickTU Plus, PolystickTU M2x, Polystic HePro, FICP Adh:�W,, Plyet- RTA-1 FI.6776 Elastoflex G TU, Elastaflex S5 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mu le-HIde SA�APP Ca p Sheet or Mule-Hlde SA-APP Cap Sheet (FRI Refer to Tile manufacturer's of Adhesive manufacturer's Florida product Approvalfor Overturning Mom ant Resistance Parftrnzanc� Evaluation Report P12060.02.09-R24 NEMOETr,LLC. FL5259-R28 naro7anc of Authvrft� 03VZ Sn' EDITION (2017) FEC NON41VHZ EVALUATION Polyglass Roof Underlaynterds; (954) 233-1230 RevIslon 24; 01/24/2018 Page 5 of 14 ON-EMO I etc. 5.6 Allowable Substrates: 5.6.1 Direct -Bond to Deck., Polystick (all variations), Dual Pro, Tile Pro, Palyflex SAP or SAP FR, Mule-HIdeSA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: > New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing plywood; New or exlstln& unprimed OSB; ASTM 041 primed OSS; Southern Yellow Pine, ASTMI D41 primed Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods 'ZIP System" Panels (designed and Installed to meet wind loads for project). Note: Polyglass does not require priming of new or existing plywood or QSB sheathing. New or existing plywood or OSS sheathing should hi cleaned of all dirt and debris prior to appikation of Polystick membranes. Elastaflex G TU� Elastoilex S6 G or Elastoflex S6 G FR In hot asphalt to: > ASTM D41 primed structural concrete. Palyflex G or Polyflex G FR torch -applied to: > ASTM D41 primed structural concrete. 5.6.2 Bord-tia-Insulation Polystick (all vadations), Polyflex SAP or SAP FR. Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: > ASTM C1299, Type 11, Class I polylsocyanurate or Type V polylsocyanurate-composite Insulation; Dens Deck DuraGuard; Dens Deck Prime, or SECUROCK Gypsum -Fiber Roof Board. Elastaflex G TU, Elastoflex S6 G or Elastaflex S6 G FR in hut asphalt to: > Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board. Polyflex G or Polyflex G FR tDrch-applied to: > ASTM D41 primed structural concrete, Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board. For Installation under mechanically attached prepared roof coverings, Insulation shall be attached per minimum requirements of the prepared roof covering manufacturees Product Approval. For installations under foam -on tile systems, insulation attachment shall be designed by a qualified design professional and installed based an testing of the Insulation/underlayment system In accordance with FBC Section 1504-3.1. 5.6-3 Bond to Mechanically Attached Base Lave : Poiystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or Tile Pro self -adhered to: > ASTM D226, Type I or 11 felt; Elastabase; Elastobase P or Mule -Hide Nall Base. Elastaflex G TU, Elastoflex 56 G or Elastitiflex S6 6 FR In hot asphalt to; > ASTM D226, Type I or 11 felt; Elastobase; Elastobase P, Mule -Hide Nall Base or Polyalass G2 Base. Polyflex G or Polyflex G FR torch -applied to: > Elastobase, Elastobase P, Mule -Hide Nall Base, Polyglass G2 Base or Palyglass APP Base. For Installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For Installations under foam -on tile systems, base layer shall be attached per minimum requirements of FRSA(TRI April 2012 (04-12), Appendix A, Table 1, or as listed In Section 5.6.4 herein, or as tested In accordance with FBC Section 1504.3.1. NEMO ETCp U.C. Enlustion Report P120150.02119-1124 en EDMON p=7) FOC NCI%-HVHZ EVAWATION FLW594tz8 Polygan Roof Underlayments; (954) 233-1230 ReVISIM 24.' OV2412018 Page6of24 ONEMOletc. 5.6A Wind Resistance for Under'layment Systems In Foam -On Tile Applications: FRSA/TR1 Apdl 2012 (04-22) does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. : The following wind uplift limitations apply to underlayment systems that are not addressed In FRSAJTRI April 2012 (04-12) and are used In foam -on file applications. Maximum Design Pressure Is the result of testing for wind load resistance based on allowable wlind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TR1 April 2012 (64- 12), Appendlic A, Table 1A or FEC 1609 for determination of design wind loads. #1 Maximum Design Pressure = -90 v Decka Min. 15/32-inch plywood to meet project requirements to satisfaction afAuthority Having Jurisdiction. Primer: None Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Potystick TU Plus, Polystick TU Max, Poyflex SAP, Polyflex SAP FR, Mule -Hide SAAPP Cap Sheet and Mule -Hide SA�APP Cap Sheet (FRI, self -adhered. #2 Maximum Deslan Pressure = -97.5 psf Derla- Min. 15/32-inch plywood to meet priiject requirements to satisfaction of Authority Having Jurisdiction. Primer: PGIGO at ASYM D41 Base Ply: (Optional) Polystick MTS or Poly5dck MTS PLUS, self -adhered. Undedaymeft Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x IN' ring shank nails through 32 ga., 1-5/8' diameter tin cap s spaced 12-Inch o.c. #3 Maid in um Design Pressu re = -105 psl� Deck., Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: wB_a0G0 - Base Ply: (Optional) Po[Mck NITS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Po"ickTU Max, Polyflex SAP, Polyflex SAP FR. Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), saff-adhered and back -nailed within the selvedge -edge side laps using 12 ga. x IYO ringshank nails through 32 ga., 1-5/9" diametertin caps spaced 12-inch o.c. #4 Maximum Design Pressure= -135 Deck: Min. 15/324nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer (Optional) PG100 or ASTM DQL Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self-adhened. JoInts: Min. 4-inch wide strips of Elastoflex SAV over all plywood Joints. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU May, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), salf-ad heriel. #5 Maximum Design Pressure = -315 Deck: Structural concrete to meet project requirements to satisfaction of Authority Having J urisdiction. Primer: PG100 or ASTM D41 Base ply'. (Optional) Polystick MTS or PolystIck MTS PLUS, seif-adhered. Underlayment: Polystick TU P, Polystick TU Plus, polystick TU Max� Tile Pro, Polyllex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule-Hilde SA-APP Cap Sheet (FR), self�dhered #6 Maximum Design Pressure= -622.5 a Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer. PG1GGorASTM D41 Underlayment: Elastaflex G TU or Elastallex SIS G, applied In full mopping of hot asphalt or Polyflex G, torch-appled. #7 Maximum Design Pressure w -30.0 Psf* Decla, Min. 15/324nch OSB to meet project requirements to satisfaction of Authority HavingJurisdiction. Base Sheet: Elastobase or Mule -Hide Nall Base (pololm top surface) Fasteners: 11 Be. x IjS-Inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows. Base Ply; (Optional) Polystick MTS or Polystick NITS PLUS, self -adhered. Underlaymem: Polystick TU P, PolystickTU Plus, Polystick TU May, PoWex SAP, Polyflax SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. NEMO ETC, UJC. Enluatton Report P12060.02.09-1124 en EDMON (ZU7) FOC NON-HVHZ EvALuAnoN FLWS9-R28 Potiglass Roof Undarlayments, (SS4) 233-1230 Rmlelon 24; 01/2412018 Page7 of 14 ONEMOJetc. #8 Maximum Design Pressure = -37.5 psf* Deck: Min. 25/32-inch plywood to meet project requirements to satisfaction of Authority HavinfiJurlsdiction. Base Sheet Elastobase Dr Mule-Hice Nall Base (poly -film top surface) Fasteners: 11 Be. x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: G-Inch oc. at the 3-Inch wide side laps and 6-Inch o.c. at two (2) equally spaced staggered center raw& Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyffm SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and M ule-Hide SA-APP Cap Sheet (Flij, self-achered. #9 Maximum Design Pressure= -37.5 psf* Deck: Min. 19/32-lnch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One (1) ortwo (2) layers ASTM D226, Type 11 felt Fasteners: 11 ga. x 1.25-inch long x 1-Inch head diameter round metal cap nails Spacing: 6-inch ox. at the 3-inch wide side laps and 22-Inch. o.Q at two (2) equally spaced staggered center romis. Underlayment: Elastaflex 6 TU or Elastollex S6 6, applied In full mapping of hot asphalt #10 Maximum Design Pressure = -45 psf* Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Hwing J urisclIction. Base Sheet: One (1) layer ASTM D226, Type 11 felt Fasteners: 11 Be. x 3.254nch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/9-Inch diameter tin caps Spacing: 4Anch o.c. at the 24nch wide side laps and 44nch c.c. at two (2) equally spaced staggered center ram. Base Ply: (Optional; for use with self -ad hering underlayment only) Polystick MTS or Polystick MTS PLUS, seIII-adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Maut, Polyflex SAP, Polyfim SAP FR, Mul"Ide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), saff-adhered or Elastoflex G TU, applied In full mopping of hot asp halt #11 Maximum Design Pressure = -4S PSP Deck: Min. 19/32-Inch plywood to meet project requirements to satisfaction of Authority HavIng.luriscilt-tion. Base Sheet: Two (2) layers ASTM D226, Type I I felt Fasteners: 11 ga. x 1.25-Inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-Inch diameter tin caps Spacing: 9-inch c.c. at the 2-Inch wide side laps and 94nch c.c. at two (2) equally spaced staggered center ram. Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS or Polystick MTS PLUS, selfadhered. Underlaymerrh Polystick TU P, Polystid: TU Plus, Polystick TU May, Polyllm SAP, Polyll" SAP FR, Mule-HIde SAAPP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self-adfiered or Elastoflu 6 TU or Elastolleii: S6 G, applied In full mapping of hat asphalt. #12 Mindmurn Design Pressure= -45 Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Havingiurisdiction. Base Sheet: Elastabase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface fo r torch -applied cap) Fasteners: Sunpleii MAXX Cap Fasteners Spacing,. 94nch o.c. at the 2-inch wide side laps and 18-Inch ci.� attwo (2) equally spaced staggered center rows. Underlayment Elastaflex G TU or ElaStoflex S6 G, applied in full mopping of hot asphalt or Polyfi� G, torch-applIed. #13 Maximum Design Pressure = -S2.5 Ps Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority HaVing Jurisdiction. Base Sheet: Elastobase (sanded top surface for hat�asphalt or torch -applied cap or polVAInn surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch D.C. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally Spaced staggered center ram. Underlayment: Elastallex G TU or ElastcAl" S6 G, applied In fu 11 mopping afhat asphalt or POlyflaX G, torch-applled. #14 Maximum Design Pressure = -52.S P Deck: Min. 25/32-inch plywood to meet project requIrementsto satisfaction of Authority Havingludsdiction. BaseSheet: Elastoba� " Mule -Hide Nall Base (pol"Im top surface) Fasteners: Simplex Original Cap Nails Spacing: 6-Inch mc. at the 3-inch wide side laps and liminch D.C. at four (4) equally spaced staggered center rows. Base Ply., (Optional) Potystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, PoWck'(U Max, Polyflex SAP, PoWex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule-Hicle SA-APP Cap Sheet (FR), self -adhered. NEMO ETCv LLC. Ewluatlon Report P12060.02.09-1124 Urt*M CfAUthadnitbn 032455 EDIMON (20171 FBC NON-MVHZ EVALUATION FL5299-R28 Polyglass Roof Underlayments; (9S4) ZMAMO Revision 24: 01/2412018 Page 8 of 14 ONEMOletc. #15 Maximum Design Pressure= -52.5 p Deck: Min. 15/324nch plywood to met project requirementsto satisfaction of Authority HavingJurisdiction. Sam Sheet., Efastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface fortorch-applied cap) Fasteners: Simpilm Original Cap Nails Spacing: 6-Inch o.c. at the 3-Incti wide side laps and Vnch cic. at four (4) equally spaced staggered center rows. Underlaymenn Elastoflex G TU or Elestaftex S6 G, applied in full mopping of hot asphalt or POW" 6, torch-appued. #16 Maximum Design Pressure = .60 Deck: Min. 29/32-Inch plywood to meet project req uIrements to milsfactlon of Authority Having Jurisdiction. Base Sheet; Elastobase (sanded top surface for hat -asphalt or torich-applied cap or poly -film surface for torchapplied cap) Fasteners: 11 Be. x 1.25-Inch long x 3/8-Inch head dianneter annular ring shank roofing nalls at I-S/8-Inch diameter tin caps SpadW. 8-Inch o.c. at the 4-inch wide side laps and B-Tnch ci.c. at three (3) equally spaced staggered center rows. Undarlayment: Elastofiex G TU or Elastaflex 56 G, applied In full mopping of hat asphalt or Polyflex G, torch -applied. #27 Maximum Design Pressure = -60 p Deck. Min. 19/32-inch plywood to meet project requirementsto satisfaction of Authority Having Jurisdiction. Base Sheet: Elambase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: OMG #12 Standard Rocifidip with OMG Flat Bottom Metal Plates Spacing: 22-Inch oc. at the 4-Inch wide side laps and 12-Inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex 6 TU or Elastaflex 56 6, applied In full moppil ng of hot asphalt or Polyflex Gtorch-appiled. #28 Maximum Design Pressure = -67.5 Decla Min. 15/32-inch plywood to meet project req uIrements to satisfaction of Authority Having J urlsdiction. Base Sheet: Polyglass G2 Base or Polyglass APP Base (requim me of torcli-qpplied undadayment) Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: B-Inch oc. at the 4�lrich wl de side laps and 84nch or- at four (4) equally spaced staggered center rows. Underlayment: Elastoflex IS TU or Elastafflex S6 G, applied in full mapping of hat asphalt or torch -applied or Polyflex 6, torch - applied. #19 Maximum Design Pressure = -75 P Deda Min. 25/32-Inch plywood to meet project requirements to satisfaction of Authority Having.lurlsdiction. Base Sheet: Polyglass G2 Base or Polyglass APP Sue frequires use of tonch-applied undedsYment) Fasteners: Delifast #14 with Delclast Hex Plates, OMG #14 HD with DIVIG r Galvalume Steel Plates, OMG Rociftrip #14 with OIVIG Flat Bottom Plates (AccuTmc), Trufast HD with Trufast 3-Inch Insulation Plates or Simplex MA)O( Cap Fasteners Spacing: 204nch a.c. at the 44nch wide side laps and 104nch o.c. atthree (3) equally spaced staggered cerder raw& Underlayment: Elastaflex G TO or Elastofim S6 G, applied in full mopping of hat asphalt or torch -applied or Polyflex G, torch - applied. #20 Maximum Design Pressure = -90 0 Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastabase (sanded top surface for hat -asphalt or torch-appiled cap or poly -film surface for tDrch-upplied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-Inch a.c. at the 2-Inch wide side laps and GaInch o.c. at two (2) equally spaced staggered center rows. Underlaymem: Elastciflex G TU or Elastaflex S6 G, applied In fu 11 mopping of hat asphalt or Polyflex G, torch -applied. #21 Maximum Design Pressure = -90 Deck: Min. IS/BZ-Inch plywood.to meet pirciJeCtreqUirennentSt011athifaction of Authority Hwingiurisdiction. Base Sheet: Elastabase (sanded top surface for hot -asphalt or torch -applied cap or polohn surface for torch -applied cap) Fasteners: DMG #12 Standard Roofilrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: &inch a.c. atthe 4-Inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Unclerlayment:- Elastoffax G TU or Elastaflex S6 G, applied In full mapping of hat asphalt or Polyflex G, torch -applied. #22 Maximum Design Pressure = -90 P Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sancledtop surface) Fasteners: Trufast #12 DP orTrubst#14 HD with Trufast 3' Metal InsuMan Plates Spacing: 6-Inch a.c. at the 44nch Vida side laps and 6-lnch o.c. at three (3) equally spaced staggered center rOw& Underlayment: Elastoflex IS TU or Elastoflex S6 G, applied In full mopping of hat asphalt NEMOEMLLC. Evaluation Report P12060.02.09-1124 Certftte qfAudwrWilan #3240 e EDIMON PU7) FBC NGN4KVMZ EVALUATION FL=59-HZB Polygbss Rod Underlayinents, 1954) 233-IM Revision 24-.02124/2019 Page9ofldl ONEMOJetc� #23 Maximum Design Pressure= -90 Deck: Min. 25/32-Inch plywood to meet project requirements to 5atisfactl6n of Authority Having Jurisdiction. Base Sheet Polyglass G2 Base or Polyglass APP Base (requires use of torch-iippiled undedayment) Fasteners. Deldast #14 with Dekfast Hex plates, OMG #14 HD with OMG 30 Galvalume Steel Plates, OMG RociliBrip #14 with OMG Flat Bottom Plates (Accurrac), Trufast HD with Trufast 3-Inch Insulation Plates or Simplex MA)(X Cap Fasteners Spacing; 9-Inch mc. at the 4-Inch wide side laps and 9-Inch o.c. at four (4) equally spaced staggered center rows. underlayment: Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hat asphalt or ttirch-applied or Polyflex G, torch - applied. #24 Maximum Design Pressu re = -97.5 v Deck: Min. 29/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet; Elastobase or Mule�Hlde Nail Base (poly -film top surface) Fasteners: 11 go. x =54nch x 3/8-Inch head diameter annular ring shank roofing nails at 1-5/8-Inch diameter tin caps Spacing: 44nch o.c. at the 4-Inch wide side laps and 4-Inch o.c. at four (4) equally spaced staggered center rows. Base Ply: (Optional) Polysdck MTS or Polystick MTS PWS, self -adhered. Underlayment: PoWck TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule-HWe SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. #25 Maxiimu in Design Pressure = -105 p Deck: Min. 15/32-Inch plywood to meet project requireme nts to satisfaction of Authority Having Jurisdiction. Base Sheet: Ele3tobase (sanded top so rface for hotasphalt or torch -applied cap or poly -film surface for torch -a pplied cap) Fasteners: Simplex IMAXX Ca p Fasteners Spacing: i5-Inch o.c. at the 2-Inch wide side laps and Vinch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastollex 6 TU or Elastoflex 56 G, applied in full mopping of hat asphalt or Polyflex G, torch-appiled. #26 Maximum Design Pressure = -112.5 p Deck: Min. 19/82-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule-HIde Nail Base (poly -film top surface) Fasteners: 11 Ca. x 1.25-inch x 3/8-Inch head diameter annular ring shank roafing nails at I-5/8-Inch diametertincaps Spacing: 6-Inch oc at the 4-Inch wide side laps and 6-Inch oc. at four (4) equally spaced staggered center mws� Primer. PG100 or ASTM D41 primer at all tin -caps Base Ply: Polystick MYS or PolystIck MTS PWS, self -adhered Underlayment: Polystick TU P, PolystickrU Plus, Polystick TU May, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self�dhered. #27 Maximum Design Presisure = -120 Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot-asphaft or torch -applied cap or pGly-film surface fortorch-applied cap) Fasteners: OMG #12 Standard RcofgrIp or OMG #14 Heavy Duty with OMG 30 Round Metal Plates or OMS Flat Bottom Metal plates Spacing* 64nch o.c. at the 4-Inch wide side laps and 6-Inch o.c. at five (S) equally spaced staggered center rows. Underlayment: Elastaflex G TU or Elastollex SS G, applied In full mopping of hat asphalt or Polyflex G, torcWpplled. #28 Maximum Design Pressure = -120 PsE Deck: Min. 25/32-inch plywood to meet project requirementsto satisfaction of Authority HavingJurisdiction. BaseSheet; Elestobase (sanded top surface) Fasteners: Trufast #12 DP or Truiast#14 HD with Trufast 3' Metal [mutation Plates Spacing. 6-Inch o.c. at thet-inch wide side laps and G-Inch o.c. at five (5) equally spaced staggered center rows. Underlayment: Elastoflex 6 TU or Elastoflex S6 G, applied in full mopping of hat asphalt 5.6.4.1 All other dlrect-cleck� adhered Polyglass underlayment systems beneath foam -on tIle systems carry a Maximum Design Pressure of -45 jisf. NEMOEMLLC- Ewluation Report P12060.02.09-R24 Q,UftCM OfA uftd=VM 0M EDMON (2027) FOC WON-HVHZEVAWATION R525"28 po[V&ss Roof Underfaipments, (954) 233-2230 Revision 24-.01/24/201B Page 10 of 14 ONEMOjetc. 5.6.4.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRl April 2022 (04-12), Appendix A, Table IA. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure date rmined In accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment densitty designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDI, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 3.17. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.7 Exposure Limitations: Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30-days after installation. PoWick IR-Xe or Polystick MU-X shall not be left exposed for longer than 90-days after Installation. Polystlick MTS, MTS PLUS, TIJ P. TU Plus, TU Max, Dual Pro, Tile Pro or Elastaflex: G TU shall not he left exposed for longerthan 180-days after Installation. Polyflex SAP or SAP FR, or Mule-Hlde SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure limitation, unless the prepared roof covering Is to be adhesive -set tile, In which case the maximum exposure Is 30 days. Elastoflex S6 G or Elastoflex S6 G FR or Polyflex G or Polyflex G FR does not have an exposure limitation, unless the prepared roof covering Is to be adhesive -set tile (Elastoflex S6 G or Polyflex G only), In which case the mindmum exposure is 180 days. 5.8 Polystildc MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226 roofing felt In a cry condition, tested at standard laboratory conditions. Agreement between purchaser and seller, as set forth In Section 4.3, Note 1 of ASTM D3.970-2$, should be established as to slip resistance. 5.9 Tile Sllppaae Limitations (FRSA/TRI April 2012 (04-121): When loading roof tiles on the iinderlayment In direct -deck fife assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. *WPAISA Underfainnent 'rile Profile Staging Method Maximum Slope EIastoflexGTU Flat 2"lle stack 7:12 Lugged &-tile stack IS over 2) 6:12 Elasioflex� G or SG 6 Fit Flat or Lugged &tile stack (4 over 2) 4:12 Powck MTS or MTS PLUS Flat &tHe stack (4 over 2) 5:12 Lugged 6-tile stack (4over 2) 4:12 PolystickTile Pro Flat or Lugged 6-tile stack (4 over 2) 7:12 PolystickTU Max Flat 6-tile suck (4 over 2) or 3Z-tile stack 7:12 Lugged 6-tile suck (4over2) 7:22 Lugged 10-tile stack 6:12 PalystickTU P Flat 6-tile stack (4 over 2) 6;22 Lugged 6-dle stack (4 over 2) 4:12 PolystickTU Plus flat or Lugged Ftfle stack (4 over 2) 7:12 Flat or Lugged 10-tile stack 6:22 !j1,,V,1MGOr 2 1 Flat or Lugged 6-tile stack (4 over 2) 4:12 Po exi P YSA P FR Flat or Lugged I &tile stack (41 over 2) 1 4:12 1 NEMO M LLC- e%mluatlon Repartft=60.02.09-R24 EDITION (2017) FOC NONMVHZ EVALUAMON FLSM-R28 PoVgI= Roaf Undmlaymentr (954) 233-U30 ReAsIon 24:01124/2018 Page 22 of 14 ONEMOjeft. 6. INSIALLAnow 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published Installation requirements subjecittothe Limitations setforth in Section 5 herein and the specifies noted below. 6.2 Re -fasten any loose decking panels, and checkfor protruding nail heads. Sweep the substrate thoroughlyto remove any dust and debris prior to application, and prime the substrate (If applicable). Shall be Installed in compliance with the codified requirements for ASTM D226, Type 11 underlayment hi FBC Table 1507.1.1 for the type of prepared roof covering to be installed. Elastabase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Pailystick, Polyflex: SAP, Polyflex SA P FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FIR), selfadhered, Elastollex G TU, Mastoflex S6 G, or Elastoflex S6 6 FR in hot asphalt or Polyflex: 6 or Polyflex 6 FR, torch applied. Roof cover limitations are those are those associated with the top -layer underlayment as set forth in Table 1, 6.3.2 Tile Applications: Elastobase, Elastobase P or Mule-Hlde Nail Base are limited to use as a mechanically attached base sheet in theTwo Ply System" from FRSA/TRI April 2012 (04-12). Reference Is made to Table I and Section SAA herein, coupled with FRS" April 2012 (04-1Z) Installation Manual. &4 DW 0 AV or: pcil� 'A ekS'AP 1W SAP Fit TU TV M*. To ""W �'fJA 440SA-APPOpr5be� z t' -:77 ku" ule z,, .' ., 6.4.1 Shall be Installed In compliance with the codified requirements for ASTIVI D1970 (except Polystick TU P) underlayment 6.4.2 In FBC Table 1507.1.1 for the type of prepared roof covering to be installed. Direct -to -Deck with Mechanically Fastened Roof Covers: All self -adhering materials, with the exception of Polvstick TLI Plus, Polyflex SAP or SAP FIR and MuIL-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) should be badc-nalled in selvage edge seam In accordance with Polyglass / Mule - Hide back nailing guidelines. Nails shall be corrosion resistant, 22 gauge ring -shank type with a minimum 2-Inch diameter metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TLI Plus should be back - ,nailed using the above noted fasteners and spacing, In area marked "nail area, area Para clavar" on the face of membrane. The head lap membrane Is to cover the area being back -nailed. All sea[4ap seams (selvage lops) must be firmly railed with a minimum 28 lb. hand roller to ensure full contact and adhesion. For Dual Pro and Tile Pro, align the edge of the top sheet to the end of the glue pattern (the sheet will overlap the fabric). LM View at Ovelap Seam of awl Pro and 7118 Im All over -fabric and over -granule end -laps shall have a 64nch wide, uniform layer of Palyplus SO Premium Modified Wet/Dry Cement or Polyglass P6500 Modified Cement applied In between the application of the lap. Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details NEMOETr,LLr, Ewluation Repon P12060.02.09-1124 EDITION (=7) FSC NON4MHZ EVALUATION FLS239-R28 Polinglass Roof Underlaymentse (51S41233-V30 ReV4*laft 24:01/2412018 Page 12 of 14 ONEMOletc. Repair of Pollystick membranes is to be accomplished by applying Polyplus SO Premium Modified Wet/Dry Cement or Polyglass P6500 Modified Cement to the area In need of repair, followed by a minimum 6 x 6 inch patch of the Polystick material of like kind, set and hand rolled In place over the repair area. Patch laps, If needed, sheff be Installed In a water shedding manner. All Polystick membranes shall be Installed to ensure full contact with approved substrates. Polyglass requires a minimum of 404b weighted -roller or, on steep slopes, use of it stiff broom with approximately.40-lbs of load applied for the field membrane. Hand rcille� are acceptable for rolling of patches, laps (min. 28 lb roller) or small areas of the roof that are not accessible to a large roller or broom. 6.4.3 Tile Applications (not allowed for Pblystick Dual Pro, IR-Xe or Pahartick W"): Reference Is made to FRSA/TRi April Z012 (04-12) Installation Manual and Table I herein, using the Instructions noted above as a guideline. For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base Sheet fastening shall be not less than FRSA/TRl April 2012 (04-12), Table L Far adh esive-set tile applications, refer to Section 3.6.4 herein. 6.4A Two (2) Ply Underlayment Systems: Polystick MYS or MTS PLUS followed by PoWck MTS, M73 PLILIS, TU P, TU Plus, TU Max, Tile Pro, MLI-X or Polyflex .SAP Is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the top -layer material. This Is not a requirement but is allowable if a 2-ply underlayment system is desired. Palystick MTS or MTS PLUS followed by Polystick TU P, TU Plus, TU Max, Tile Pro or Polyflex SAP Is allowable for use under foam -on tile systems. Limits of use are those associated with the top -layer material. This is not a requirement, but Is allowable If a 2-ply underlaVment system is desired. 6.5.1 Elastuflex 6 TU, Elastaflex SS G or Elastuflex S6 6 FR shall be installed In compliance with current PolUlass published Installation requirements. For,use In tile applications: • Elastoflex 6 TU is for use as an alternate to "Mineral Surface Roll Roofing' (ASTM D6380, Class M) In the 'Single Ply System" from FRSAITRI April 2012 (04-12) beneath mechanically fastened tile roof systems orthe Hot Asphalt applied "Cap Sheer in the 'rwo Ply Systerrr from FRSA/TRl April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. • Mastuflex: S5 6 is for use as an alternate to 'Mineral Surface Roll Roofine(ASTM D6380, Class M) In the �Slngle Ply System" from FRWTRl April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied ftCap Sheer In the �Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. • Eastoillex S6 G FR Is for use as an alternate to "Mineral Surface Roll Roofing' (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheer in the 'rwo Ply System' from FRSA/TFU April 2012 (04-22) beneath mechanically fastened tile roof systems. 6.5.2 For hot -asphalt -applications, Elastaflex G TU, Elastoflex SIS 6 or Elastaflex SS G FR shall be fully asphalt -applied to the substrates noted In Section 5.6. Side laps shall be minimum 3-Inch and end4aps minimum 6-Inch wide, aff-set minimum 3 feet from course to course. Side and end laps shall be fully adhered In a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. Polyflex G or Palyflex G FR shall be Installed In compliance with current Polyglass published Installation requirements. For use In Via applications: v� Polyflex G Is for use as an alternate to the, Heat Applied 'Cap Sheer In the "Two Ply System" from FRSA/TRI April 2032 (04-12) beneath mechanically fastened or adhered tile roof systems (Base Sheet limited per 5.6-3). 0' Polyflex G FR Is for use as an alternate to the Heat Applied "Cap Sheet' In the 'Two Ply System' from FRSA/TRI April 2012 (04-3.2) beneath mechanically fastened tile roof systems (Base Sheet Limited per 5.6.3). NEW M LLC. Ewluation Report P12060.02A39-R24 ceptlikoft CfAUWo*abnA32455 IEDMON CM27) FBC NON-KVKZ EVALUAMON FLS25!6R28 PoVsiaw R90 Underlaymenb; (954) 233-1230 Reyislan 24:01/24/2018 Page 23 of 14 ONEMOjetc. 6.6.2 Polyflex 6 or Polyfilex 6 FR shall he fully torch -applied to the substrates noted In Section 5.6. Side laps shall be minimum 34nch and end -laps minimum 6-Inch wide, off -set minimum 3 feet from course to course. Side and end laps shall be fully heat -welded and inspected to ensure minimum 3/8-Inch flow of modified compound beyond the lap edge. 6.7 Tile Stagink, 6.7.1 Tile shall be loaded and staged Ina manner that prevents tile slippage and/or damage to the underiayment Referto Table 2 herein, and Polyglass published requirements for tile staging. 6.7.2 Battens and/or Counter�battens, as required by the tile manufacturer and FRSA/TRJ April 2012 (04-12) must be used on all roof slopes greater then 7:12. Precautions should be taken as needed, such as the use of battens or nall- boards, to prevent tile sliding and/or damage to the underlayment during the loading process. 6.7.3 Polyglass specifies the minimum cure time after Installation of self -adhering membranes and before loading of rotifing tiles Is forty-eight (48) hours. 7. BUILDING PERMIT REQUIREMENTS! As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. 61620-3 GA requirements. The following plants have qualified products under their respective physical properties specifications. 77777777 _i�rnley, NV, Hazleton, PA & Writer Haven, FL ASTM D1970 Palystick MU-X Hazleton, PA M-D 13-0004 Elastoilex G TU Hazleton, PA & Winter Haven, FL ASTM D1970 Polvstick IR-)(e ASTM D2970 & FRSAtrRI April 2032 Po[Vst1ckTU Plus ASTM D1970 & FRWMI April 2022 PoilystIck TU Max Tuscaloosa, AL ASTM D4601, Type 11 Polyglass G2 Base Yfinter Haven, FL ASTM D226 (physicals) Elastobase, Elastobase P ASTM D6509 Polynla� APP Bai;e FRSA/Ml April 2012 Polystck MTS, Polvsfl k MTS PLUS FRSA/TR1 April 2012 PolystckTU P FRSAITRI April 2012 Polyfleoc SAP, PoWex SAP Fit ASTM D1970 Polystick Dual Pro ASTM D1970 & FRSA)TRI April 2012 PoIvsUck.Tle Pro ASTM D6164 Elastoftex SIS, Elastofiex S6 G Fit ASTM D6222 PoWex G, Poilyflex G FR 9. QUALITY ASSURANCE ENTiTY: LIL, LLC — QUA9625; (314) 578-3406, k.chancellor@us.ul.com - END OF EVALUATION REPORT - NEMormi.i.c. Evaluation Report P12060M.09-1124 CertaZore qfAuthwAQ Mon 93240 EDMON (ZM7) F11C NON-KVHZ EvALuAn0N FL52594211 Polygm Roof UnderlaVaients; (954) 233-WO RevWon 24:01/241268 Page 14 of 14