EVALUATION REPORT
NEMO I etc.
Certylcate afAuthorlmaon 02455
353 Christian Street, Unit #13
Oxford, CT 06478
(203)262-9245
CONSULT CERTIFY
Polyglass USA, Inc. Evaluation Report P12060.02.09-R24
1111 West Newport Center Drive FL5259-R28
Deerfield Beach, FL 33442 Date of Issuance:02124/2009
(954)233-1230 Revision 24:01/24/2018
SCOPE:
This Evaluation Report is issued under Rule 61620-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E.
for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the a Edition (2017) Florida Building Code sections noted
herein.
DESCRIPTION: Polygiass Roof Underlayments
LABEuNG: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPDANCE: This Evaluation Report is valid until such time as the named products) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nleminen, P.E. of any changes to the
products), the Quality Assurance or the production facility laeation(s). NEMOIetc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOJeta Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. '
INSPEcnow Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for Inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 14.
Prepared by:°eta
fi'e"w
e �=?
Robert J.M. Nleminen, P.E.^'-
No. 5916 Florida DCA ANF1983
Or The fadmHeseal appea ngwasauthorbetl by RobertNlemnen
this does notserve as an electronically
1!: P.E.ed
Florida Registration
9 �
Q'..::n�� •
Deem nt.'
signed documene
CERDFICAMON OF INDEPENDENCE:
1. NEMOIetc. does not have, nor does it intend to acquire or will it acquire, a financial interest In any company manufacturing or
distributing products It evaluates.
2. NEW (etc. Is not owned, operated or controlled by any company manufacturing or distributing products It evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial Interest in any company manufacturing or distributing products for
. which the evaluation reports are being Issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financialInterest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither NEW Ietc. nor Robert Nieminen, P.E. are, in anyway, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
RODHNGCOMPONENTEVAWAriom
1. SCOPE:
Product Category: Roofing
Sub -Category: Undedayment
Compliance Statement.• Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the
fallowing sections of the a Edition (2017) Florida Building Code through testing in accordance with the following Standards.
Compliance Is subject to the installation Requirements and Limitations / Conditions of Use set forth herein.
2. SrANDARDS:
Section
Property
Standard
Year
1504.3.1
Wind Uplift
FM 4474
2011
SSM3.1
Wind Uplift
UL 1897
2012
1507.2.3/1507.Li
Physical Properties
ASTM D226
2009
1507.2.4 / 1507.1.L 1507.2.9.2
Physical Properties
ASTM D1970
2015
1507.3.3
Physical Properdes
FRSA/TRI April 2022
2012
1507.11.2
Physical Properties
ASTM D6164
2011
1507AL2
Physical Properties
ASTM D6222
2011
TAS 110
Accelerated Weathering
ASTM D4798
2011
3. REFERENCES:
Ent
Examination
Reference
Date
FM Approvals MT 1867)
Wind Uplift
30=91
01/12/2000
PRI (TST5878)
Physical Properties
PR101111
04/08/2002
PRI(TST5878)
Physical Properties
PUSA-005-02-01
01/31/2002
Pill (TST 5878)
Physical Properties
PUSA-013-02-01
22/23/2002
PRI 05T 5878)
Physical Properties
PUSA-01302-02
12/23/2002
'PRI (TST 5878)
Physical Properties
PUSA-013-02-03
12/23/2002
PRI tM75878)
Physical Properties
PUSA-018-02-01
07/14/2003
PRI WS87S) -
Physical Properties
PUSA-028-02-01
07/13/2005
PRI DST 5878)
Physical Properties
PUSA-033-02-01
01/12/2005
PRI (TST 5878)
Physical Properties
PUSA-035-02-01
09/29/2006
PRI (TST 5878)
Physical Properties
PUSA-055-02-02
12/10/2007
PRI (TST 5878)
Physical Properties
PUSA-061-02-02
01/28/2008
PRI (TST 5878)
Physical Properties
PUSA-076.02-01
02/22/2008
PRI (TST 5878)
Physical Properties
PUSA-083-02-01
04/14/1008
PRI M5878)
. Physical Properties
PUSH-088-02-01
07/29/2009
MTI (TST2508)
Physical Properties
Nf2OH7A
D4/01/2008
MTI (TST 2508)
Physical Properties
IMAM
O3/29/2009
ERD (TST 6049)
Physlwl Properties
11752.09.99-1
02/08/2000
ERD CM 6049)
Wind Uplift
11757.08.01.1
0113/2001
ERD (TST 6049),
Wind Uplift
11776.05.02
01/16/2003
ERD (TST 60491
Physical Properties
02200.07.03
07/14/2003
ERD M7 SO49)
Wind Uplift
P1740.OL07
.01/04/2007
ERD M6049)
Physical Properties
1,5110.04.07-1
04/11/2007
ERD CM 6049)
Wind Uplift
P9260.03.08
03/22/2008
ERD(TST6049)
Physical Properties
.P13450.08.09
08/13/2009
ERD tW60491
Wind Upltft
P30540.11.09-R1
12/30/2009
ERD(TST 6049)
Physical Properties
P11030.11.09.1
31/30/2009
ERD (MT 6049)
Wind Uplift
P11030.11.09.2
11/30/2009
ERD (TST 6049)
Physical Properties
P31030.11..09.3
11/30/200.9
ERD M6049)
Physical Properties
P33360.06.10
06/25/2020
ERD(TSr6049)
Physical, Properties
P33370:03.11
03/02/2031
ERD(TST 6049)
Physical Properties
P33370.04.11
04/26/2011
ERD (TST 6049)
Physical Properties
P37300.10.11
10/19/2011
NEMO E7Cq LLC. Evaluation Report P12060.0109•R24
@rSyiLpMef/lad"G flan Csa4SS. 6's EDItiDN(2017) F8C NON.NVH2 EVALUATON F1' 8
Palyglass Roof Underlaymenrr, (954) 233.1230 Rewslon 24: 01/24/2038
Page 2 of 14
Entity
ERD (TST 5049)
ERD (TST 6049)
ERD MT 6049)
ERD (TST 6049)
ERD M76049)
ERD (TST 6049)
ERD 07 6049)
ERD,(TST 5049)
ERD (TS(' 6049)
ERD CM 6D49)
ERD (f5T 6049)
ERD (TST 600)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (i5T 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (15T 6049)
ERD (TST 6049)
ERD CYST 6049)
ERD (1ST 6049)
ERD CYST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 600)
.ERD (1ST 6049)
]CC -ES (EVL 2396)
Miaml-Dade (CER 1592)
Polyglass USA
Polyglass USA
Polyglass USA
UL, U.C. (QUA9625)
4. PRODUCT DESCRIPTION:
Examination
Physical Properties
Physical Properties
Physical Properties
Wind Uplift
Physical Properties
Wind Uplift
Wind Uplift
Wind Uplift
Wind Uplift
Wind Uplift
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Wind Uplift
Physical Properties
Wind Uplift
Physical Properties
Physical Properties
Physical Properties
IBC Compliance
HVHZ Compliance
Manufacturing Affidavit
P/L Affidavit
Materials Affidavit
Quality Control
Reference
P4090.08.32-1
P40390.08.32-2
C414ZO.09.12-3
P396SM03.13
P45370.04.13
P173&02.07-R2
31757.04.01-1-R1
P41630.08.13
P1175LO5.03-RI
P3178L31.03-R1
P45270.05.14
6020.07.14-1
6020.09.24-2
6020.09.14-3
6020.09.24-4
6020.09.14-5
6020.09.14.E
P46520.10.14
P43290.10.14
PLYG-SC7550.03.15
P40390.04AS
P44350.10.14-R1
PLYG-SCSD60.05.15-1
PLYG-SC8905.05.16-1
PLYG-SCSOS0.07.36
PLYG-SC12025.10.16
PLYG-SC33040.12.16
PLYG-SC31900.03.17
PLNG SC12115.08.17
ESR-1637
NOA 14-0717.08
Products Current
Mule -Hide Cross I%
Palysdck SA Compound
Service Confirmation
4.2.2 Elastobase Is a fiberglass reinforced, SBS modified bitumen base sheet.
4.12 Elastobase P is a polyester -reinforced, SSS modified bitumen base sheet.
4.2.3 Polyglass 62 Base Is fiberglass -reinforced, asphaltic base sheet.
4.1.4 Polyglass APP Base is a fiberglass -reinforced, APP modified bitumen base sheet.
ONEMOjetc.
Date
O8/06/2012
D6/U7/ZD12
09/11/2012
03/04/2013
04/26/2013
04/29/2013
04/30/2013
O8/0612033
12/26/2013
11/26/203.3
05/12/203.4
09/08/2014
09/08/2014
09/08/203.4
09/O8/2034
09/08/2024
09/08/2014
10/03/2014
10/17/2014
03/24/2025
04/03/2015
05/18/2015
05/20/2025
05/27/2026
07/16/2016
10/12/2016
22/27/2026
03/10/2017
09/09/2017
11/01/2024
01/2Z/2015
02/13/2009
03/02/2008
08/28/2011
Exp.10/05/2018
42.1 Polystick MIS or PolysdCk.MM PWS Is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass
fiberreinforced, surfaced with polyolefinic film surface; meets.FRSA/TRI April 2012.
4.2.2 Polystick IR-Xe,is a nominal 60-m11 thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an
aggregate surface, meets ASTM D1970.
4.2.3 Polo. Ick TU Plus is a nominal 80-mll thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a
polyester fabric surface; meets ASTM D1970 and FRSA/TRI April2012.
MEMO Or, LLG Evaluadori Report P12060.02D9-W
Maul nk efAuftrtuabn032455 a EDmON (2017) F13C NON-HVHZ EVALUATION FLSM-R28
Polyglass Roof underlayments: (es4) 233-1230 Revision 24:01/24/2018
Page 3 of 24
ONEMOJetc.
4.2A Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane; glass-fiber/polyester
reinforced, with a granular surface; meets FRSA/TRI .April 2012.
UZ Polystick TU Max Is a nominal 60-mll thick rubberized asphalt waterproofing membrane with a 190 g/m2 polyester
fabric surface; meets ASTM D1970 and FRSA/TRI April 2012.
4,2.6 Polyflex: SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) are polyester.
reinforced, APP modified bitumencapsheets; meet FRSA/TRI April 2012.
4.2.7 PoWcc Dual Prom Is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyesterfabric surface; meets ASTM D1970.
4.2.8 Polystick Tde ProTM is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2012.
4.29 Polystick MU-X is a nominal 54-mil thick, dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polypropylene film surface; meets ACIM and physical requirements of ASTM D1970 (See Section
5,8).
4.3.1 Elastaflex G TU is a polyester reinforced, modified bitumen tile underlayment composed of a sand -surfaced SBS
modified bitumen back -side and granule -surfaced APP modified bitumen top -side. Elastoflex G TU is for use as an
alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the 'Single Ply System" from FRSA/TRI April
2012 (04-12) beneath mechanically fastened file roof systems or Hot Asphalt applied "Cap Sheet" in the "Two Ply
System" from FRSA/TRI April 2012 (D4-12) beneath mechanically fastened or adhered tile roof systems.
4.3.2 Elastoffex S6 6 and Elastoflex S6 G FR are polyester reinforced, SBS modified bitumen cep sheets; meet ASTM D6164.
Elastoflex S6 Gand Elestoflex S6 G FR are for use as an alternate to "Mineral Surface Roil Roofing" (ASTM D6380,
ClassM) In the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened file roof systems.
Elastoflex S6 G Is for use as an alternate to Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI
April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Elastaflex S6 G FR Is for use as an
alternate to Hot Asphalt applied "Cap Sheet" in the 'Two Ply System" from FRSA/TRI April2D32 (04-12).beneath
mechanically fastened tile roof systems.
4.3.3 Polyflex 6 and Polyflex 6 FR are polyester minforced, APP modified bitumen cap sheets, meet ASTM D6222.
Polyflex G Is for use as an alternate to Heat Applied "Cap Sheet' in the'Two Ply System" from FRSA/TRI April 2012
(04.12) beneath mechanically fastened or adhered tile roof systems. Polyflex G FR is for use asan alternate to Heat
Applied "Cap Sheet" in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened the
roof systems.
S. LIWAT1ONS:
5.2 This is a building code evaluation. Neither NEMOI etc nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, Is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report Is not for use in the HVHZ
5.3 Fire Classification Is not part of this Evaluation Report refer to current Approved Roofing Materials Directory for fire
ratings of this produce ,
5.4 Polyglass Roof Underiayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. if not listed, a request may be made to. the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering..
MUD E7tq ILC. Evaluation Report P12060.02A9-R24
Maputo efA.VWnZff=OA7455 ar" EDmON(2017) Fae NON-RVNz eVAWATION Revision 24:01/7A/2016
Polyg�Roef Undeilaymems;(954) 233-12R0 i
Page 4 of 14
ONEMOjetc.
5.5 Allowable Roof Covers:
„,'FA.BCEl RooF''CovER OPTIONS. >>. .�
Underlaymem
AsphaRShingles
Na"nTile
Foam-on]tle
Metal
WoodShakes
&ShinR1es
Slam
Elasmhase
Yes
Yes
(Base Shen inzpl sMeml
Yes
(aasesbeetn22-dYsystem)
Yes
Yes
Yes
ElasmbaseP
Yes
yes
asasesheetln2-plvpvsmml
Yes
la.msheam 2yiYms+s)
Yes
Yes
Yes
Polygiaw G2 Base
No
Imseshea nYes
PNsvmeml
(eamsheetnes dv sysmm)
No
No
No
Polyglass APP Base
No
Yes
(aamsheetln2•vk'v/+tam)
Yes
(eem SheRln2-ph/sysrem)
No
No
No
Polystick MTS or MTS PLUS
Yes
Yes
No
Yes
Yes
yes
Po[WUck lR-Xe
Yes
No.
No
No
Yes
Yes
PolockTU P
No
Yes
Yes (See5.5.1)
No
No
No
PolysdckTU Plus
Yes
Yes
Yes (See5.5.3)
Yes
Yes
Yes
PolysockTU Max
No
Yes'
Yes (See55.1)
Yes
No
No
PolysackEwlPm
Yes
No
No
Yes
yes
I Yes
PolystickTilelim
Yes
Yes
Yes (See 5.5.1)
Yes
Yes
Yes
Pohadck MU-X
Yes
No
No
Yes
Yes
Yes
E18stoflaxS6G
Yes
Yes
Yes (See5.5.1)
No
Yes
Yes
Elastofl"SSG FR
Yes
Yes
No
No
Yes
Yes
Elastoflex GTU
Yes
Yes
Yes (See 55-11
No
Yes
Yes
PowlexG
Yes
Yes
Yes (See 55.1)
No
Yes
Yes
PolyflexG FR
Yes
Yes
No
No
Yes
Yes
PalyflexSAP or SAP FR
Yes
Yes
Yes (See 55.1)
No
Yes
Yes
Mul&Hlde SA-APP Cap Sheet
or SA-APP Cap Sheet (FR)
Yes
Yes
Yes (See 55.1)
No
Yes
Yes
5.5.1 "Foam -On Tile' is limited to use of the following Approved the adhesives / underlayment combinations.
. ,,:•: :.... TapIE3A: At1Q1N%�qf{:'PIuiAAQ;;1�?ryEIUd141ER}AYaIIENx'�Ni�iPlA716}151:..•� •.'
Adhesive .
Florida Product
Underlayments
Approval
DAP Foam Touch'n Seal Stormilond Roof
FL14506
Polystick TU Plus, Polystick TU Max
Tile Adhesive
DowTileBond"'
FL22525
PolystickTU P, PolWick TU Plus, Palyflex SAP or Tile Pro
Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro,
ICP Adhesives Polyset" AH-160
FL6332
Elastaflex G TU, Elastoflex 56 G, Polyflex G, Polyflex SAP, Palyflex SA Cap FR,
Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR)
Polystiek TU P, Polystick TU Plus, Polystick TU Max, Polysdck Tile Pro,
ICP Adhesives Polyseta RThl
FL6276
Elastoflex G TU, Elestoflex 56 G, Polyflex G, PGlyflex SAP, Polyflex SA Cap FR,
Mule-Hlde SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FRI
x Referto Tile Manufacturer's or Adhesive Manufacturers Florida ProductApprovol for Overtuming MomentResismnm Perfamsance
NEMO ETC, LLC. Ewluadon Report P12060.07 09-R24
[ertylmrcsyAYrhvraatlana3245S firs EDITION (2a17) FBC NON-HVH2 EVALUATION RBNslan 24: 0U4� 2g
l20
Polyglass Roof Undedaymelds; (954) 733-1230
Pages idle
NNEMOJetc.
5.6 Allowable Substrates;
5.6.1 Direct -Bond to Deck:
Polystick (all variations), Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet
.(FR) self -adhered to:
D New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing
plywood; New or existing, unprimed OSB, ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed
Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods 'ZIP System" Panels
(designed and installed to meet wind loads for project).
Note: Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or
OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes.
Elastoflex G TU; Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
D ASTM D41 primed structural concrete.
Polyflex G or Polyflex G FR torch -applied to:
D ASTM D41 primed structural concrete.
5.6.2 Band -to -Insulation:
Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered
to:
D ASTM C1289, Type 11, Class 1 polyisocyanurate or Type V polyisocyanurate-composite Insulation; Dens Deck
DuraGuard; Dens Deck Prime, or SECUROCK Gypsum -Fiber Roof Board.
Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
D Dens Deck Prime orSECUROCK Gypsum -Fiber Roof Board.
Polyflex G or Polyflex G FIR torch -applied to:
D ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, Insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile
systems, Insulation attachment shall be designed,by a qualified design professional and installed based on testing of
the insulation/underlayment system in accordance with FBC Section 1504.3.1.
5.63 Bond to Mechanimily Attached Base Laver:
Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or
Tile Pro self -adhered to:
D ASTM D226, Type I or 11 felt; Elastobase; Elastobase P or Mule -Hide Nall Base.
Elastoflex G TU, Elastoflex 56 G or Elastoflex S6 G FR In hot asphalt to:
D ASTM D226, Type I or 11 felt; Elastobase; Elastobase P, Mule -Hide Nall Base or Polyglass G2 Base.
PolyOex G or Polyflex G FR torch -applied to:
D Elastobase; Elastobase P, Mule -Hide Nall Base, Polyglass G2 Base or Polyglass APP Base.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam -on tile systems, base layer shall be attached per minimum
requirements of FRSA(TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested In
accordance with FBC Section 15043.1.
NEMO ETC, U.C. Ewluadon Report P32060.02A9-1174
eer =i afA"MakmbnCa741S eEDITION 12017) FBCNON-HVHZ EVALUATION FL5S99*ZB
PDiyglaw Roof Underlaymards; (9541233-2230 Revision 24.01/24/2018
Page 6 of 14
ONEIVIOletc.
5.6.4 Wind Resistance for U n den ent Systems In Foam -On The Applications: FRSAJTRI April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment
forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not
addressed In FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the
result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure
divided by 2 (the 2 to 1 margin of safety per FBC 15042 has already been applied). Refer to FRSA/TRI April 2012,(04-
12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads.
#1 Maximum Design Pressure =-90osf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer. None
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, selfadhered.
Underlaymekd: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), selfadhered.
#2 Maximum Design Pressure =-97.5 ttsf,
Deck: MIn.15/32-inch plywood to meet project requirements to satisfaction of Authority HavingJurisdiction.
Primer: PG300 or ASTM D41
Base Ply: (Optional) Polystick MTS or Polystick Mrs PLUS, self -adhered.
Undedayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflax SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x
IN" ring shank nails through 32 ga., 1-5/8' diameter tin caps spaced 12-inch o.c.
#3 Maximum Design Pressure=-105 osF.
Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: WB-3000
Base Ply: (Optional) Polystick MTS or PolVsdck MTS PLUS, self -adhered.
Underayment Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x
23r ring shank nails through 32 ga., 1-5/8' diametertin caps spaced12-Inch o.c.
#4 Maximum Design Pressure =-135 osf:
Deck: Min. 15/32-Inch plywood to meet projectrequirementstosatlsfaction of Authority Havinglurisdiction.
Pdmer. (Optional) PG300 orASfM D41
Base Ply: (Optional) Polystick Mrs or Polystiek MTS PLUS, self -adhered.
Johns: - Min. 4-Inch wide strips of Elastoflex SA-V over all plywood joints.
Underayment Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FRI, self -adhered.
#5 Maximum Design Pressure =-315 osf.
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply. (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlaymerm Polystick TU P, Polystick TU Plus, Polystick TU Max, Tile Pro, PolyRax SAP. Polyflex SAP FR, Mule -Hide SA-APP Cap
Sheet and Mule -Hide SA-APP Cap Sheet (FR), selfadhered.
#6 Maximum Design Pressure=-622.5 osf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Havinglurisdiction.
Primer: P5100 orASTM D41
Undedayment Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hbt asphalt or Polyflex G, torch -applied.
#7 Maximum Design Pressure=-30.0 Osfr:
Deck: Min, 15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 0-5-Inch long x 1-inch head diameter round metal cap nails
Spacing: 54nch mc. at the 3-inch wide side laps and.64nch o.c at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
NEMO ETC, LLC, evaluation Report P12000.02A9-RZ4
ClItYkax qrauthareoVmASZ435 6T" EDmON MU71 FBC NON-HVHZ EVALUATION FL5259-RIG
Peiygiass Roof Undedayments: (954) Z33-1230 Revldon 24: 01/24/2018
Page 7 of 14
ONEMOJetc.
418 Maximum Desien Pressure =-37.5 psf*
Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.254nch long x ].-Inch head diameter round metal cap nails
Spacing: 6-inchor at the 3-Inch wide side laps and 6-Inch mc. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS or Polystick WITS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TV Max, Polyffm SAP, Polyflex SAP Fit, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), selfadhered.
#9 Max(mumDesienPressure =-37.5psF*
Deck: Min.19/324nch plywood to meet project requirements to satisfaction of Authority HavingJurisdiction.
Base Sheet: One (1) ortwo (2) layers ASTM D226, Type II felt
Fasteners: 11 ga. x 1.25-Inrh long x i-Inch head diameter round metal cap nails
Spacing: 6-Inch o.c at the 3-Inch wide side laps and 12-Inch o.a. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt
#10 Maximum Design Pressure=-45 PA*
Deck: Min.19/32dnch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (1) layer ASTM D226, Type 11 felt
Fasteners: 11 Be. x1.254nchx3/9-inch head diameter annular ring shank roofing nails at 2-5/84nch diameter tin caps
Spacing: 4-Inch mm at the 24nch wide side laps and 4-inch o.c at two 12) equally spaced staggered center rows.
Base Ply: (Optional; for use with self -adhering underlaymem only) Polysdck MTS or Polystick MTS PLUS, seHadhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyllex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered or Elastoflex G TU, applied in full mopping of hot asphalt
#11 Maximum Design Pressure=-45 psf
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority HaWrig.lurisdiction,.
Base Sheet: Two (2) layers ASTM D226, Type II felt
Fasteners: 11 ga. x1.25-Inch long 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 9-inch o.c at the 2-Inch wide side laps and 9-Inch me. at two (2) equally spaced staggered center rows.
Base Ply: (Optional; for use with self -adhering undedayment only) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment Polystick TU P, Polystick TU Plus,Polystick TU Max, Payflex SAP, Polyflex SAP Fit, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered or Elasto8ex G TU or Elastoflex S6 G, applied in full mapping of hot
asphalt
#22 Maximum Design Pressure =-45
Deck: Min.15/324nch plywood to meet project requirements to satisfaction of Authority Having.lurisdlction.
Base Sheet: -Elastobase(sanded top surface for hotasphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-Inch mt at the 2-inch wide side laps and 18-Inch o.e. attwo (2) equally spaced staggered center rows.
Underlayment ElastaRex G TU or Elastoflex S6 G, applied In fullmapping of hot asphalt or Polyflex G, torch -applied.
#13 Maximum Desien Pressure =-52.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority HavingJurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cep or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXXCap Fasteners
Spacing: B-inch mc. at the 2-Inch wide side laps and 22-Inch me. at two (2) equally spaced staggered center rows.
Underiaymerd: Mastafleii G TU or Elastoflex S6 G, applied In full mopping of hot asphalt or Polyflex G, torchapplled.
#24 Maximum Design Pressure =-525
Dees: Min.15/32-Inch plywood to meet project requirementstosatisfaction of Authority HaAnglurisdictlon.
Basesheet: Elastobase or Mule-HldeNall Base(poly-film top surface)
Fasteners: Simplex Original Cap Nails
Spacing: S-Inch o.c at the 34nch wide side laps and &mch me. at four (4) equally spaced staggered center rows
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, selfadhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
NEMO ET , LLC. Ewluatlon Report P12060.02A9-1124
Cerajimte kVAUdiodntio 02455 eEOITIOPI(P017)FBC NON-HVH2EVAWATION FLS259-R28
Polygtass Roof Undedayments; (954) 233-MO Revision 24: 01/24/2013
Page 8 of 14
NNEMOJetc.
#15 Maximum Desien Pressure=-52.5 psf:
Deck: Min.15/324nch plywood to meet project requirements to satisfaction of Authority Havinglurlsdiction.
Base Sheet Elastobase(sanded top surface for hat -asphalt or torch -applied cap or poly -film surfacefortordtapplied rap)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.a at the 3-Inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torchappill
#16 Maximum Design Pressure=-60 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdlction.
Base Sheet: Elastobase(sanded top surface for hart -asphalt or torch -applied cap or poly -film surface fortorchapplied cap)
Fasteners: 11 ga. x 125-Inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-Inch diametertin caps
Spacing: 8-Inch o.a at the 4-Inch wide side laps and B-Inch o.e at three (3) equally spaced staggered center rows.
Undedayment: Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hat asphalt or Polyflex G, torch -applied.
#17 Maximum Design Pressure =-60 ps(:
Deck Min.19/32-inch plywood to meet project requirements to satisfaction of Authority HavinfiJurisdlction.
Base Sheet Elastobase(sandedtop surface for hot -asphalt or torch -applied rap or poly -film surface for torchappliedcap)
Fasteners: OMG#12 Standard Roofgrip with OMG Flat Bottom Metal Plates
Spacing: 12-Inch o.c. at the 4-Inch wide side laps and 12-inch o c, at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyfiex G, torch -applied.
#18 Maximum Design Pressure=-67.5 psi:
Deck Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlaymeMj
Fasteners: 12 ga. x 125-Inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin ceps
Spacing: 8-Inch ax at the 4-Inch wide side laps and.B-Inch o.c at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elasto0ex S6.6, applied In full mopping of hot asphalt or torch -applied or Polyflex G, torch -
applied.
#19 Maximum Design Pressure =-75 a
Deck Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underloymentj
Fasteners: Dekfast #24 with Dekfast Hex plates, OMG #14 HD with OMG r Galvalume Steel Plates, OMG Roofgrip #14 with
OMG Flat Bottom Plates (AccuTrac), Tmfast HD with Trubst 3-Inch Insulation Plates or Simplex MA%X Cap
Fasteners
Spacing: 10-Inch o.c. atthe 4-inch wide side laps and 104nch mc. atthree (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt or torch -applied or Polyflex G, torch -
applied.
#20 Maximum Design Pressure=-90 osf:
Deck. Mtn. 15/32-inch plywood to meet project requirements to satisfaction of Authority. Having Jurisdiction.
Base Sheet Elastobase(sanded top surface for hot -asphalt or torch.applied cep or poly -film surface fortorchapplied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch c.c. atthe 2-Inch wide side laps and &•inch ac. at two (2) equally spaced staggered center rows.
Underlayment Elastoflex G TU or Elastaflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#21 Maximum Design Pressure =-90 asf:
Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hotasphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: CMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3' Round Metal Plates or OMG flat Bottom Metal
Plates
Spacing: Finch o.a at the 4-inch wide side laps and 6-Inch o.e at three (3) equally spaced staggered center rows.
Underlayment Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied..
#22 Maximum Design Pressure=-90 psf.
Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast#12 DP or Trufast#24 HD with Trufast 3' Metal Insulation Plates
Spacing: 64nch o.c at the 44nch wide side laps and 6-Inch o.e at three (3) equally spaced staggered center rows.
Underlaymmt Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt.
NEW ETc. LLG Evaluation Report P12060.0209-R74
artifiram gFAUffWkW9n#32455 eEDITION (2017) FBC NON-MZEVAWATION pM59-RZ8
PNyglass Roof undedayna nts; (9541233-tt90 Revision 24: 01/24/201B
Page 9 of 14
ONEMoletc.
#23 Maximum Design Pressure =-90 osi:
Deck: Min. 25/32-Inch plywood to meet project requiremems to satisfaction ofAuthorlty Havinglurisdicbon.
Base Sheet: Polygiaw GZ Base or Polyglass APP Base (requires use of torch -applied undedayment)
Fasteners: Deklest #14 with Dekfast Hex plates, OMG #14 HD with OMG r Galvalume Steel Plates, DMG Roofgrip #14 with
OMG Flat Bottom Plates (AeeuTrac), Trufast HD with Trufast 34nch Insulation Plates or Slmplex MAXX Cap
Fasteners
Spacing: 9-Inch mc. at the 4-inch wide side laps and 9-Inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastofiex S6 G, applied In full mopping of hot asphalt or tomhapplied or Polyflex G, torch -
applied.
#24 Maximum Design Pressu re = -97.5 Is
Deck: Min.29/32-Inch plywood to meet project requirements to satisfaction of Authority HOVIngJurisdiRlon.
Base Sheet: Elastabase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.254nch x 3/8-Inch head diameter annular ring shank roofing nails at 1-5/8-Inch diameter tin caps
Spacing: 44nch o.a at the 4-Inch wide side laps and 4-inch c.c. at four (4) equally spaced staggeredcenter rows.
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, PolystickTU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#25 Maximum Design Pressure =-105 Dsf:
Deck: MIn.15/32-Inch plywood to meet project requirements to satisfaction of Authority HavingJurisdiction.
Base Sheet: Elastobase(sanded top surface for hot -asphalt or torch -applied cap or polyfilm surface for torch -applied rap).
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-Inch o.o at the 2-Inch wide side laps and 6-Inch o.c. at three (3) equally spaced staggered center rows.
Undedayment Elastoll G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, tomhapplied.
#26 Maximum Design Pressure = -112.5 osF.
Deck: MIn.19/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elostobase or Mule -Hide Nail Base (poly film top surface)
Fasteners: 11 go. x1.25-inch x3)8-inch head diameter annular sing shank roofing nails at 1-5/8-Inch diameter tin caps
Spacing: 6-Inch o.r at the flinch wide side laps and 6-inch o.c. atfour (4) equally spaced staggered center rows.
Primer: PG1OO orASfM D41 primerat all tin -caps
Base Ply: Polystick MTS or Polystick MTSPLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), selfadhered.
#27 Maximum Design Pressure=-120osf:
Deck: Min. 15/32-Inch plywood to meet project requirementsto satisfaction of Authority Havinglurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied rap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgdp or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing. 64nch o.a at the 4-Inch wide side laps and 6-inch o.c. atfive(5) equally spaced staggered center rows.
Underlayment: ElastoOex G TU or Elasta0ex SG G, applied in full mopping of hot asphalt or Palyflex G, torch -applied.
#28 Maximum Design Pressure=-120 osf:
Deck Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface)
Fasteners: Trufast#12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates
Spacing. &Inch o.c. at the 44neh wide side laps and 6-Inch o.e at five (5) equally spaced staggered center rows.
Underlayment. Elastoflex G TU or Elastofiex S6 G, applied In full mopping of hot asphalt.
5.6.4.1 All other direct -deck, adhered Polyglass underlayment systems beneath foam -on the systems carry a Maximum
Design Pressure of-45 psf.
NEMO EM LLC. Evaluation Report P12060.02A9-R24
07WAMWCfAuN lionlon#3ZM 6'v EDITION(2017) FBC NON4HVHZEVALtIATION F15259-62a
Polyglaw Roof Undesiayments, (954) 233.2230 Revision 24: M/24/2018
Page 10 of 14
I
ONEMoletc.
5.6.4.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed
that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design
pressure determined In accordance with FBC 1609. in this case, Zones 2 and 3 shall employ an attachment density
designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are
ANSI/SPRI WD3, FM Lass Prevention Data Sheet 1-29 and Roofing Application Standard RAS117. Assemblies marked
with an asterisk` carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January
2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30-days
after installation.
Polystick IR-Xe or Polystick MU-X shall not be left exposed for longer than 90-days after Installation.
Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Dual Pro, Tile Pro or Elastoflex G TU shall not be left exposed for
longerthan 180-days after installation.
Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does. not have an exposure
limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure is 30
days.
Elastoflex S5 G or Elastoflex 56 G FR or Polyflex G or Polyflex G FR does not have an exposure limitation, unless the
prepared roof covering is to be adhesive -set file (Elastoflex S6 G or Polyflex G only), in which case the maximum
exposure Is 180 days.
5.8 Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226
roofing felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller, as
set forth in Section 4.3, Note 1 of ASTM D1970-15, should be established as to slip resistance.
5.9 Tile Silobage Limitations (FRSA/TRI April 2012104-1211i
When loading roof tiles on the underlayment In direct -deck the assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
. ... ..•.. `.iABA�it:-Td{E.SLiPRA1'G,E;iIMITA`fIGNSFGgR30(ft�k'
i�'4.,1_iF...P.rl:`IIb`�ISI .,I�TION,S... ; •:r "'�:::
Undedayment
Tile Profile
Staging Method
Maximum Slope
Elastaflex G TU
Flat
10-tile stack
7:12
lugged
8dlle stack (6 over 2)
6:12.
Elastaflex%6 or S6 G FR
Flat or Lugged
&tile stack (4 over 2)
4:12
Polystick MTS or MTS PLUS
Flat
&tile stack (4 over 2)
5:12
Lugged
6-tile stack (4 aver 2)
4:22
PolystickTlle Pro
Flat or Lugged
&tllestack(4over2)
7:12
PoWck TU Max
Flat
6-tfle stack (4 over 2) or 20-tile stack
7:12
Lugged
6-tile stack (4 over 2)
7:12-
Lugged
- 10•tile stack
6:12
PolystickTU P
Flat
&tile stack (4 over 2)
6:12
Luged
6-tile stack (4 over 2)
4-12
PolysdckTU Plus
Flat or Lugged
&tile stack (4 over 2)
712
Flat or Lugged
10-tile stack
6:12
POlyflexG orG FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polyflex SA P or SA P FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
NEMO ETC, LLC. Evaluadon Report P12060.02.09-1124
amrmke oJaumwumnn o224S5 aEDITION(2a17)F9CNON4IVHZEVALUATION FL6269-R211
Polyglass Roof Underlaymentr (964) 233-12R0 RVASbn 24: OV2412018
Page 21 of 14
ONEMO I etc.
6. INSTALLATION:
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements
subjectto the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application, and prime the substrate (if applicable).
..
6.3 Elastpbase;Elastdba5e:?gciNple-Nide'NaifHasec .., .. •. .. ., ,...w-,;,,,.;•,, ;;-.:, . .
6.3.1 Non -Tile Applications:
Shall be installed in compliance with the codified requirements for ASTM D226, Type ii undeHayment in FBC Table
1507.L1 for the type of prepared roof covering to be installed.
Elastobase; Elastobase P or Mule -Hide Nail Base may covered with a layer of.Polystick, Polyflex SAP, Polyflex SA
P FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered, Elastoflex G TU, Masroflex S6 6 or
Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR, torch applied. Roof cover limitations are those are
those associated with the top -layer underlayment, as set forth in Table 1,
6.3.2 Tile Applications:
Elastobase, Elastobase P or Mule -Hide Nail Base'are limited to. use as a mechanically attachedbase sheet in the "Two
Ply System"'from FRSA/TRI April 2022 (04-12). Reference is made to Table 1 and Section S.6.4 herein, coupled with
FRSA/TRIApril 2012 (04-12) Installation Manual.
,6.4: Polystjt,,k:,IyFSS!PU9,S.s:7(r.'7fe,TU..Pi fPiF15r'1't(Mdl4Dyd��ftfT%.l!Idlair';INU�Z(:pe:Po(yfiek•SAh::P4Cy(IeiGSkR':
. MulHide�'A.A.aR'Cap'S'hteFtDr,`1V141e-Ailde;SA1PPpSh'eei(t,')tj3:`:'
6.4.1 Shall be Installed In compliance with the codified requirements for ASTM D1970 (except Polystick7U P) undedayment
6.4.2
In FBC Table 1507.L3 for the type of prepared roof covering to be installed.
Direct -to -Deck with Mechanically Fastened Roof Covers:
All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA-APP
Cap Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage edge seam In accordance with Polyglass / Mule -
Hide back nailing guidelines. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 24nch
diameter metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.e. Polystick TU Plus should be back -
nailed using the above noted fasteners and spacing, in area marked "nail area, area pars clever" on the face of
membrane. The head lap membrane is to cover the area being back -nailed.
All seal -lap seams (selvage laps) must be
firmly rolled with a minimum 28 lb. hand
roller to ensure full contact and adhesion.
For Dual Pro and Tile Pro, align the edge of
the top sheet to the end of the glue pattern
(the sheet will overlap the fabric). LAW
View of OvelaP Seam of peal Pro and the Pm
All over -fabric and over -granule end -laps shall have a &Inch wide, uniform layer of PDlyplus So Premium Modred
Wet/Dry Cement or Polyglass PGSOO Modified Cement applied In between the application of the lap.
PolystickTU:Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys,
or exposed roof to wall details
NEMO ETC, LM Evaluation Report P12060.02.09•R24
@rpf5aw afAummtmdan d3240 ew EDITION (2037) FBC NCWHVHZ EVALUATION FLU99-RZB
Pol2glas4 Roof underlayments; (934) 233-2230 Revision 24:02/20018
Page 12 of 14
ONEMOjetc.
Repair of Polystick membranes Is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or
Polyglass PG500 Modified Cement to the area in need of repair, followed bya minimum 6 x 6 inch patch of the
Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, If needed, shall be
Installed In a water shedding manner.
Al PoWick membranes shall be Installed to ensure full contact with approved substrates. Polyglass requires a
minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff broom with approximately40-lbs of load applied
for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min. 28111 roller) or small areas of the
roof that are not accessible to a large roller or broom.
6.4.3 Tile Applications (nut allowed forP6]wtkk Dual Pro. IRXe or Polvsrick M&A
Reference Is made to FRSA%TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions
noted above as a guideline.
For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base
Sheet fastening shall be not less than FRSA/TRI April 2012 (04-12),Table L
For adhesive -set tile applications, refer to Section SAA herein.
6.4,4 Two (21 Ply Underlavment Systems:
Polystick MTS or MTS PLUS followed by Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Tile Pro, MU-X or Polyflex
SAP Is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with
the top4ayer material. This Is not a requirement, but is allowable if a 2-ply underlayment system is desired.
Polystfck MTS or MTS PLUS followed by PoWck TU P, TU Plus, TU Max, Tile Pro or Polyflex SAP is allowable for use
under foam -on the systems Umlts of use are those associated with the top -layer material. This Is not a requirement,
but is allowable if a 2-Div underiavmerlt system Is desired.
6.5.1 Elastaflex 6 TU, Elastoflex S6 G or Ehastoflex S6 G FR shall be installed in compliance with current Polyglass published
Installation requirements. For use In tile applications:
✓ Elastaflex G TU is for use as an alternate to "Mineral Surface Roil Roofing" (ASTM D6380, Class M) in the "Single
Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheer in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex S6 G is for use as an alternate to "Mineral Surface Roll Roofing" [ASTM D6380, Gass M) in the "Single Ply
System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened the roof systems or the Hot Asphalt
applied "Cap Sheet' in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or
adhered tie roof systems.
✓ Elastaflex S6 6 FR is for use as an alternate to "Mineral Surface Rail Roofing" (ASTM D6380, Class M) in the "Single
Ply System" from FRS'A/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile
roof systems.
6.5.2 For hot -asphalt -applications, Elastaflex G TU, Elastaflex SS 6 or Elastaflex S6 G FR shall be fUlly 2Sphalt-applied to the
substrates noted in Section 5.6. Side laps shall be minimum 3-Inch and end -laps minimum 64nch wide„ off -set
minimum 3 feet from course to course. Side and end laps shall be fully adhered In a complete mopping of hot asphalt
with asphalt extending approximately 3/94nch beyond the lap edge.
6.6.2 Polydex G or Polyflex G FR shall be Installed in compliance with current Polyglass published Installation requirements.
For use in tile applications:
✓ Polyflex G is for use as an alternate to the Heat Applied "Cap Sheet" In the "Two Ply System" from FRSA/TRI April
2022 (04-12) beneath mechanically fastened or adhered tile roof systems (Base Sheet Limited per 5.6.3).
✓ Polyflex G FR is for useas an alternate to the Heat Applied "Cap Sheet" In the 'Two Ply System" from FRSA/TRI
April 2022 (04-22) beneath mechanically fastened the roof systems (Base Sheet Limited per 5.6.3).
NEMO ETC, LLC. Evaluation Report P320a0MM-R24
Q:dUmf04(AOM0rMbn432M EDITION(2017) FBC NON44VN2 EVALUATION FILMS.=
Polyglaa roof Underiaymmds; 19SQ 233-3T3o Revision 24:01/2412018
Page 13 of 14
i
ONEMO[etc.
6.6.2 Polyflex 6 or Polyflex 6 FR shall be fully torch -applied to the substrates noted in Section 5.6. Side laps shall be
minimum 34nch and end -laps minimum 6-Inch wide, off -set minimum 3 feet from course to course. Side and end
laps shall be fully heat -welded and inspected to ensure minimum 3/8-Inch flow of modified compound beyond the lap
edge.
6_7 TileStaeinw,
6.7.1 Tile shall be loaded and staged Ina manner that prevents tile slippage and/or damage to the underlayment. Refer to
Table 2 herein, and Polyglass published requirements for tile staging.
6.7.2 Battens and/or Counter -battens, as required by the the manufacturer and FRSA/1RI April 2012 (04-12) must be used
on all roof.slopes greater then 7:12. Precautions should be taken as needed, such as the use of battens or nail -
boards, to prevent the sliding end/or damage to the underlayment during the loading process.
6.7.3 Poigiass specifies the minimum are time after Installation of self -adhering membranes and ,before loading of
roofing tiles Is forty-eight (48) hours.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Offldal or Authority Having Jurisdiction in orderto properly evaluate the installation of this product.
8. MANUFALTURING PLANTS:
Contact the noted CIA agency for information on product locations covered for FA.C. 616ZG-3 QA requirements. The following
plants have qualified products under their respective physical properties specifications.
WaM>..' .'• .:., [ , . ; :'••-.:;:.., • r..
S ec'ifieatrorrta.....�:`:� .., , G, :.'
rd d s'
Fernley, NV, Hazleton, PA & Winter Haven FL
ASTM D1970
Polystick MU-X
Hazleton, PA
M-D 13.0DD4
Elastoflex G TU
Hazleton, PA & Winter Haven, FL
ASTM D1970
Polystick IR-Xe
ASTM D1970 & FRSA/TRI April 2012
Poly4ckTU Plus
ASTM D1970 & FRSA/rRl April 2012
PolystickTU Max
Tuscaloosa, AL
ASTM D4601, Type II
Polvalass G2 Base
winter Hawn, FL
ASTM D226 (physicals)
Elastobase, Elastobase P
ASTM 05509 -
Polvelass APP Base
FRSA/TRI April 2012
Polystick MTS, Polystick MTS PLUS
FRSA/rRIA d12012
Pol sbckTUP
- FRSAJTRI A r112012
Polyflex SAP, Pa ex SAP FR
ASTM 01970
Polystick Dual Pro
ASTM D2970 & FRSA/rRl April 2012
Polvsdck'nle Pro
ASTM OM64
Elastofex 56, Elastoflex S6 G FR
ASTM D6222.
Polyflex G Polyflex G FR
9. Quarry ASSURANCE ENTITY:
UL, LLC—QUA9625; (314) 578-3406, kchancellor@us.ul.com
- END ,OF EVALUATION REPORT -