36' X 80"
REPLACE DOOR IN 1 OPENING ONLY.
NEW DOOR TO BE IMPACT RESISTANT -
HURRICANE SHUTTERS NOT REQUIRED.
gl� -6Is�
ST LUCIE COUNTY
BUILDING DIVISION
REVIEWED
FOR COMPLIAN E
FED BY
MUST BE KEPT ON JOB OR
NO INSPECTION WILL BE MADE
3E PLANS AND ALL PROPOSUD WOCX
SUBJECT TO ANY CORRECTIONS
UIRED BY FIELD INOWPE07ORS -1NAT
BE NECESSARY IN ORDER TO
PLY WITH ALL APPLICABLE CODES.
CONCEALED FASTENERS OR ATTACHMENT;
ARE THE RESPONSIBILITY OF THE
CONTRACTOR OF RECORD
OPENING
PRODUCT
DESIGN
OPENING
SQ.
WIND
PRESSURES
APPROVAL
PRESSURES
I
COMMENTS
NO. WDTH. HGT.
FTG.
ZONE
POS. NEG.
(N.O.A.#)
POS. NEG.
1 1 36 1 80
20.01
4
53.8 1 -57.1
FL22363.1
60.0 1 -65.0
FRONT ENTRY - LSMI
REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS.
NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS.
ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 1/4" TAPCON SCREWS INTO CONCRETE
WITH A MINIMUM 1 1/4" PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS.
LESS THAN 30% OF STRUCTURE'S VALUE. NOT A RENOVATED BUILDING. EXEMPT FROM 2017 ENERGY CONSERVATION CODE.
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES
MEAN ROOF HEIGHT = 87 FT 4 IN
DUTCHER CONDO UNIT
9400 S. OCEAN DRIVE, UNIT 706B
JENSEN BEACH, FLORIDA
DOOR REPLACEMENT PLAN