Loading...
HomeMy WebLinkAboutNOTICE OF PRODUCT CERTIFICATIONNOTICE OF PRODUCT CERTIFICATION Company: Masonite International Corporation SCANNED Certification No.: 1955 Powis Road Certification Date: West Chicago, IL 60185 BY Expiration Date: St. Lucie County Revision Date: NI013717.17-R1 05/12/2017 05/31 /2021 11/20/2017 t� •' 'tr : "•� Product: Fiberglass Opaque Inswing or Outswing Door w/ and w/o Non -Impact Rated Sidelites ` (w/Wood Frame or Worldwide Composite Frame° unless noted) Specification: TAS 202-94/ASTM E330-02/ASTM E1886-05/ASTM E1996-09 Impact: Wind Zone 4-Missile Level D Non -Impact Glazing: Insulating Glass (Tempered) The "Notice of Product Certification" is only valid if the NAMI Certification Label has been applied to the product as described within this document. The certification label represents product conformity to the applicable specification and that all certification criteria has been satisfied. This product has been approved for listing within NAMI's Certified Product Listing at www Non.:...fi P•�.•N..e e..... NAnrp� .. _ ... .. _..__. ...................... ..................... •.rim• a •.c• uucmrm• a • V • alai •, al,ciedilud by l he American Narlumal Standards rn$rttme A1N51). Inswing Glazed Structural Water Missile Test Report Number Configuration or or Maximum Design Test Impact Drawing Number & X I/S Opaque 3'0" x 6'8" +60/-65 0.0 psf Yes NCTL-210-3835-IAV-1812 Single Maximum Panel Size: 3'0" x 6'8" Anchor Details -DWG-MA-FL0187-17 Single 6.0 psf' Maximum Panel Size: 3'0" x 6'8" 8.25 psf' Anchor Details-MA-1`1.0187-17 9.0 psfs XX I/S Opaque 6'0" x 6'8" +50/-50 0 psf Yes ATLNC 0831.01-16/ATLNC 0901.02-16 Double Maximum Panel Size: 3'0" x 6'8" Anchor Details-DWG-MA-FL0187-17 XX O/S Opaque 6'0" x 6'8" +501-50 3.75 psf Yes ATLNC 0831.01-16/ATLNC 0901.02-I6AV-1813/W-1843 Double 6.0 psf' Maximum Panel Size: 3'0" x 6'8" 8.25 psf' Anchor Dcrails-DWG-MA-FL0187-17 8.25 sf s XO/OX VS Opaque Door 6'0" x 6'8" +501-50 0 psf Door -Yes ATLNC 0831.01-16/ATLNC 0901.02-16 Single w/Sidelite Glazed Sidelite Sidelite-No Maximum Panel Size: 3'0" x 6'8'7Sidelite: 3'0" x 6'8" Anchor Details-DWG-MA-FL0187-17 XO/OX O/S Opaque Door 6'0"x 6'8" +501-50 3.75 psf Door -Yes ATLNC 0831.01-16/ATLNC 0901.02-I61W-1813AV7843 Single iv/Sidelite Glazed Sidelite 6.0 psf' Sidelite-No Maximum Panel Size: 3'0" x 6'8"/Sidelite: 3'0" x 6'8" 8.25 psf Anchor Details-DWG-MA-FL0187-17 9.0 psfs OXO I/S Opaque Door 9'0" x 6'8" +501-50 0 psf Door -Yes ATLNC 0831.01-16/ATLNC 0901.02-16 Single w/Sidelites Glazed Sidelite Sidelites-No Maximum Panel Size: 3'0" x 6'8"/Sidelite: 3'0" x 6'8" Anchor Details-DWG-MA-FL0187-17 OXO O/S Opaque Door 9'0"x 6'8" +501-50 3.75 psf Door -Yes ATLNC 0831.01-16/ATLNC 0901.02-16/W-18tNW-1843 Single w/Sidelites Glazed Sidelite 6.0 psf' Sidelites-No Maximum Panel Size: 3'0" x 6'8"/Sidelite: 3'0" x 6'8" 8.25 psf Anchor Details-DWG-MA-171-0187-17 9.0psf' OXXO I/S Opaque Door 12'4" x 6'8" +501-50 0 psf Door -Yes ATLNC 0831.01-16/ATLNC 0901.02-16 Double w/Sidelites Glazed Sidelite Sidelites-No Maximum Panel Size: 3'0" x 6'8"/Sidelite: 3'0" x 6'8" Anchor Derails-DWG-MA-FL0187-17 OXXO O/S Opaque Door 12'4" x 6'8" +501-50 3.75 psf Door -Yes ATLNC 0831.01-16/ATLNC 0901.02-I6M'-1813/W-1843 Double w/Sidelites Glazed Sidelite 6.0 psf' Sidelites-No Maximum Panel Size: 3'0" x 6'8"/Sidelite: 3'0" x 6'8" 3.25 psf Anchor Details-DWG"MA-FL0187-17 8.25 psfs • - ....P......,..s • „•u ,. .,c„a dig l nresvma u-nl-uam wr5lymg • nMSM10 4-n-15J5 o-wortdxtde Pro "IA Threshold National Accreditation & Management Institute, Inc./4794 George Washington Memorial Highway/Hayes, VA 23072 Tel: (804) 684-5124/Fax: (804) 684-5122 NAMI AUTHORIZED SIGNATURE: