HomeMy WebLinkAboutNOTICE OF PRODUCT CERTIFICATIONNOTICE OF PRODUCT CERTIFICATION
Company: Masonite International Corporation SCANNED Certification No.:
1955 Powis Road Certification Date:
West Chicago, IL 60185 BY Expiration Date:
St. Lucie County Revision Date:
NI013717.17-R1
05/12/2017
05/31 /2021
11/20/2017
t� •' 'tr : "•� Product: Fiberglass Opaque Inswing or Outswing Door w/ and w/o Non -Impact Rated Sidelites
` (w/Wood Frame or Worldwide Composite Frame° unless noted)
Specification: TAS 202-94/ASTM E330-02/ASTM E1886-05/ASTM E1996-09
Impact: Wind Zone 4-Missile Level D Non -Impact Glazing: Insulating Glass (Tempered)
The "Notice of Product Certification" is only valid if the NAMI Certification Label has been applied to the product as described within this document. The certification label represents
product conformity to the applicable specification and that all certification criteria has been satisfied. This product has been approved for listing within NAMI's Certified Product Listing
at www Non.:...fi P•�.•N..e e..... NAnrp� .. _ ... .. _..__.
...................... .....................
•.rim•
a •.c• uucmrm• a • V
• alai •, al,ciedilud by
l he American Narlumal
Standards rn$rttme
A1N51).
Inswing
Glazed
Structural
Water
Missile
Test Report Number
Configuration
or
or
Maximum
Design
Test
Impact
Drawing Number &
X
I/S
Opaque
3'0" x 6'8"
+60/-65
0.0 psf
Yes
NCTL-210-3835-IAV-1812
Single
Maximum Panel Size: 3'0" x 6'8"
Anchor Details -DWG-MA-FL0187-17
Single
6.0 psf'
Maximum Panel Size: 3'0" x 6'8"
8.25 psf'
Anchor Details-MA-1`1.0187-17
9.0 psfs
XX
I/S
Opaque
6'0" x 6'8"
+50/-50
0 psf
Yes
ATLNC 0831.01-16/ATLNC 0901.02-16
Double
Maximum Panel Size: 3'0" x 6'8"
Anchor Details-DWG-MA-FL0187-17
XX
O/S
Opaque
6'0" x 6'8"
+501-50
3.75 psf
Yes
ATLNC 0831.01-16/ATLNC 0901.02-I6AV-1813/W-1843
Double
6.0 psf'
Maximum Panel Size: 3'0" x 6'8"
8.25 psf'
Anchor Dcrails-DWG-MA-FL0187-17
8.25 sf s
XO/OX
VS
Opaque Door
6'0" x 6'8"
+501-50
0 psf
Door -Yes
ATLNC 0831.01-16/ATLNC 0901.02-16
Single w/Sidelite
Glazed Sidelite
Sidelite-No
Maximum Panel Size: 3'0" x 6'8'7Sidelite: 3'0" x 6'8"
Anchor Details-DWG-MA-FL0187-17
XO/OX
O/S
Opaque Door
6'0"x 6'8"
+501-50
3.75 psf
Door -Yes
ATLNC 0831.01-16/ATLNC 0901.02-I61W-1813AV7843
Single iv/Sidelite
Glazed Sidelite
6.0 psf'
Sidelite-No
Maximum Panel Size: 3'0" x 6'8"/Sidelite: 3'0" x 6'8"
8.25 psf
Anchor Details-DWG-MA-FL0187-17
9.0 psfs
OXO
I/S
Opaque Door
9'0" x 6'8"
+501-50
0 psf
Door -Yes
ATLNC 0831.01-16/ATLNC 0901.02-16
Single w/Sidelites
Glazed Sidelite
Sidelites-No
Maximum Panel Size: 3'0" x 6'8"/Sidelite: 3'0" x 6'8"
Anchor Details-DWG-MA-FL0187-17
OXO
O/S
Opaque Door
9'0"x 6'8"
+501-50
3.75 psf
Door -Yes
ATLNC 0831.01-16/ATLNC 0901.02-16/W-18tNW-1843
Single w/Sidelites
Glazed Sidelite
6.0 psf'
Sidelites-No
Maximum Panel Size: 3'0" x 6'8"/Sidelite: 3'0" x 6'8"
8.25 psf
Anchor Details-DWG-MA-171-0187-17
9.0psf'
OXXO
I/S
Opaque Door
12'4" x 6'8"
+501-50
0 psf
Door -Yes
ATLNC 0831.01-16/ATLNC 0901.02-16
Double w/Sidelites
Glazed Sidelite
Sidelites-No
Maximum Panel Size: 3'0" x 6'8"/Sidelite: 3'0" x 6'8"
Anchor Derails-DWG-MA-FL0187-17
OXXO
O/S
Opaque Door
12'4" x 6'8"
+501-50
3.75 psf
Door -Yes
ATLNC 0831.01-16/ATLNC 0901.02-I6M'-1813/W-1843
Double w/Sidelites
Glazed Sidelite
6.0 psf'
Sidelites-No
Maximum Panel Size: 3'0" x 6'8"/Sidelite: 3'0" x 6'8"
3.25 psf
Anchor Details-DWG"MA-FL0187-17
8.25 psfs
• - ....P......,..s • „•u ,. .,c„a dig l nresvma u-nl-uam wr5lymg • nMSM10 4-n-15J5 o-wortdxtde Pro "IA Threshold
National Accreditation & Management Institute, Inc./4794 George Washington Memorial Highway/Hayes, VA 23072
Tel: (804) 684-5124/Fax: (804) 684-5122