FL #
FL22363-R3
Application Type
Revision
Code Version
2017
Application Status
Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by
the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Certification Agency
Validated By
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
13
Masonite International
1955 Powis Road
West Chicago, IL 60185
(800)663-3667
sschreiber@masonite.com
Steve Schreiber
sschrelber@masonite.com
SC NN,1 L)
St. Lucie County
Exterior Doors
Swinging Exterior Door Assemblies
Certification Mark or Listing
National Accreditation & Management Institute
National Accreditation & Management Institute
Standard
ASTM E1886
ASTM E1996
ASTM E330
TAS 202
Vear
2005
2009
2002
1994
Product Approval Method '
Method 1 Option A
Date Submitted 07/18/2018
Date Validated 10/03/2018
Date Pending FBC Approval
Date Approved 10/03/2018
Siimma�iv nf`o�nd ale' — ___
FL # -Model, Number or Name Description
22363.1 Fiberglass Side -Hinged Door Unit
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +60/-65
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do exceed the design pressures
listed. 3'-0" x 6'-8" max nominal size. Hurricane protective
system required in HVHZ, but not in the Wind Borne Debris
Region. See DWG-MA-WL0187 for details.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +60/-60
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do exceed the design pressures
listed. 3'-0" x 6'-B" max nominal size. Hurricane protective
system required in HVHZ, but not In the Wind Borne Debris
Region. See DWG-MA-WL0187 for details.
6'-8" Opaque I/S Single Door
Certification Agency Certificate
FL22161 R CAC N1013717 17-R7 odf
Quality Assurance Contract Expiration Date
05/31/2021
Installation Instructions
FL22363 R3 11 FI_ 0187 odf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22363 R3 AE 514010A.odf
FL22363 R9 AF 514014A.ndf
Created by Independent Third Party: Yes
Certification Agency Certificate
FL22363 R3 C CAC NI013717 17-R7 ndf
Quality Assurance Contract Expiration Date
05/31/2021
Installation Instructions
FL22363 R3 11 Fl. 0187 odf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22363 R3 AE 514010A ndf
FL22363 R3 AE 514014A,ndf
Created by Independent Third Party: Yes
22363.3 I Fiberglass Side -Hinged Door Unit 16'-S" Opaque I/S or O/S Single or Double Door w/ or w/o
Limits of Use
Approvedforuse in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +50/-50
Other: Evaluated for use in locations adhering to the Florida
Building Code, Including the High Velocity Hurricane Zone, and
where pressure requirements do exceed the design pressures
listed. 12'-0" x 6'-8" max nominal size. Hurricane protective
system required in HVHZ, but not in the Wind Borne Debris
Region. See DWG-MA-WL0187 for details.
Certification Agency Certificate
FL22363 R3 C CACN1013717,17-R2.ndf
Quality Assurance Contract Expiration Date
05/31/2021
Installation Instructions
FL22363 R3 II FL 0187 ndf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22363 R3 AP 514008A odf
FL22363 R3 AF 514012A.odf
Created by Independent Third Party: Yes
22363.4 I Fiberglass Side -Hinged Door Unit 16'-8" Glazed I/S or O/S Single or Double Door w/ or w/o i
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +40/-40
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do exceed the design pressures
listed. 12'-0" x 6'-8" max nominal size. Hurricane protective
system required in HVHZ and the Wind Borne Debris Region.
See DWG-MA-WL0189 for details.
22363.5 1 Fiberglass Side -Hinged Door Unit
Certification Agency Certificate
FL22363 R3 C CAC NI013717 03-R2 odf
Quality Assurance Contract Expiration Date
05/31/2021
Installation Instructions
FL22363 R II FI 0189,ndf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22363 R3 AE 5t4008A,pdf
FL22363 R3 AF 514012A,odf
Created by Independent Third Party: Yes
6'-8" 3/4-Late Glazed I/S or O/S Single or Double Door w/ or
w/o Sidelites
Limits of Use
Certification Agency Certificate
Approved for use in H!' Yes
Approved for use outs .9,IVHZ: Yes
Impact Resistant: No
Design Pressure: +50/-50
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do exceed the design pressures
listed. 12'-0" x 6'-8" max nominal size. Hurricane protective
system required in HVHZ and the Wind Borne Debris Region.
See DWG-MA-WL0193 for details.
FL22363 R. CAC NI013717.04-R2.1)df
Quality Assurance Contract Expiration Date
05/31/2021
Installation Instructions
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party: Yes
22363.6 Fiberglass Side -Hinged Door Unit 16'-8" Impact Glazed I/S or CIS Single or Double Door w/ or w/o
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +50/-50
Other: Evaluated for use in locations adhering to the Florida
Building Code, excluding the High Velocity Hurricane Zone, and
where pressure requirements do exceed the design pressures
listed. 12'-0" x 6'-8" max nominal size. Hurricane protective
system not required in the Wind Borne Debris Region. See
DWG-MA-WL0195 for details.
Certification Agency Certificate
FL22363 R3 C CAC NI013717.05-R2_ndf
Quality Assurance Contract Expiration Date
05/31/2021
Installation Instructions
FL22363 R3 II FL 0195.odf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22363 R3 AE 514008A.ndf
FL22363 R3 AE 514012A.odf
Created by Independent Third Party: Yes
122363.7 1 Fiberglass Side -Hinged Door Unit 1 8'-0" Opaque I/S Single Door
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +60/-65
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do exceed the design pressures
listed. 3'-0" x 8'-0" max nominal size. Hurricane protective
system required in HVHZ, but not in the Wind Borne Debris
Region. See DWG-MA-WL0188 for details.
Certification Agency Certificate
FL22363 R3 C CAC NI013717.18-Rl.edf
Quality Assurance Contract Expiration Date
05/31/2021
Installation Instructions
FL22363 R3 II FL 0188.Ddf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22363 R3 AE 514009A.odf
FL22363 R3 AE 514013A odf
Created by Independent Third Party: Yes
22363.8 I Fiberglass Side -Hinged Door Unit 1 8'-0" Opaque O/S Single Door
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +60/-60
Other: Evaluated for use in locations adhering to the Florida
Building Code, Including the High Velocity Hurricane Zone, and
where pressure requirements do exceed the design pressures
listed. 3'-0" x 8'-0" max nominal size. Hurricane protective
system required in HVHZ, but not in the Wind Borne Debris
Region. See DWG-MA-WL0188 for details.
Certification Agency Certificate
FL22363 R3 C CAC NI013717.18-RS ndf
Quality Assurance Contract Expiration Date
05/31/2021
Installation Instructions
FL22363 R3 IT FL 0188.odf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22363 R3 AE 514009A.odf
FL22363 R3 AE 514013A.odf
Created by Independent Third Party: Yes
22363.9 I Fiberglass Side -Hinged Door Unit 18'-0" Opaque I/S or O/S Single or Double Door w/ or w/o
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +50/-50
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do exceed the design pressures
listed. 12'-0" x 8'-D" max nominal size. Hurricane protective
system required in HVHZ, but not In the Wind Borne Debris
Region. See DWG-MA-WL0188 for details.
Certification Agency Certificate
FL22363 R3 C CAC NI013717.18-RI.odf
Quality Assurance Contract Expiration Date
05/31/2021
Installation Instructions
FL22363 R3 II FL 0188.odf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22363 R3 AF 514007A.odf
FL22363 R3 AE 514011A.0df
Created by Independent Third Party: Yes
22363.10 Fiberglass Side -Hinged Door Unit 18'-0" Glazed I/S or O/S Single or Double Door w/ or w/o
Limits of Use
Approved for use in HVHZ: Yes
Certification Agency Certificate
FL22363 R3 C CAC NI013717.08-Rl.ndf
Approved for use outs' .IVHZ: Yes
Impact Resistant: No
Design Pressure: +40/-40
Other: Evaluated for use in locations adhering to the Florida
Building Code, Including the High Velocity Hurricane Zone, and
where pressure requirements do exceed the design pressures
listed. 12'-O" x 8'-0" max nominal size. Hurricane protective
system required in HVHZ and the Wind Borne Debris Region.
See DWG-MA-WL0190 for details.
22363.11 1 Fiberglass Side -Hinged Door Unit
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +40/-45
Other: Evaluated for use in locations adhering to the Florida
Building Code, excluding the High Velocity Hurricane Zone, and
where pressure requirements do exceed the design pressures
listed. 12'-0" x 8'-0" max nominal size. Hurricane protective
system not required in the Wind Borne Debris Region, See
DWG-MA-WL0196 for details.
Quality As: .'Ice Contract Expiration Date
OS/31/2021
Installation Instructions
FL22363 R3 It FL 0190.ndf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22363 R3 AE 514007A.odf
FL22363 R3 AE 514011A.odf
Created by Independent Third Party: Yes
8'-0" Impact Glazed I/S Single or Double Door w/ or w/o
Sidelites
Certification Agency Certificate
FL22363 R3 C CAC NI013717.09-RI.ndf
Quality Assurance Contract Expiration Date
05/31/2021
Installation Instructions
FL22363 R3 II FL 0196.odf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22363 R3 AE 514007A.odf
FL22363 R3 AE 514011A.odf
Created by Independent Third Party: Yes
22363.12 I Fiberglass Side -Hinged Door Unit 18'-0" Impact Glazed O/S Single or Double Door w/ or w/o
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +45/-40
Other: Evaluated for use In locations adhering to the Florida
Building Code, excluding the High Velocity Hurricane Zone, and
where pressure requirements do exceed the design pressures
listed. 12'-0" x 8'-0" max nominal size. Hurricane protective
system not required in the Wind Borne Debris Region. See
DWG-MA-WL0196 for details.
Certification Agency Certificate
FL22363 R3 C CAC NI013717 09-R1 odf
Quality Assurance Contract Expiration Date
05/31/2021
Installation Instructions
FL22363 R3 II FL Ol 6.odf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22363 R3 AE 514007A.odf
FL22363 R3 AF 514011A.odf
Created by Independent Third Party: Yes
22363.13 I HPC Fiberglass Side -Hinged Door Unit 18'-0" Glazed I/S or O/S Single or Double Door w/ or w/o
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +47/-47
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do exceed the design pressures
listed. 12'-0" x 8'-0" max nominal size. Hurricane protective
system required in HVHZ and In the Wind Borne Debris Region.
Door top rails stamped "HPC". See DWG-MA-WL0192 for
details.
Certification Agency Certificate
FL22363 R3 C CAC NIO13717.07-Rl.odf
Quality Assurance Contract Expiration Date
05/31/2021
Installation Instructions
FL22363 R3 II FL 0192.odf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22363 R3 AE 514007A.ndf
FL22363 R3 AE 514011A.0df
Created by Independent Third Party: Yes
22363.14 I HPC Fiberglass Side -Hinged Door Unit I W-13" Glazed
zed I/S or O/S Single or Double Door w/ or w/o
tes
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +50/-50
Other: Evaluated for use in locations adhering to the Florida
Building Code, Including the High Velocity Hurricane Zone, and
where pressure requirements do exceed the design pressures
listed. 12'-0" x 6'-8" max nominal size. Hurricane protective
system required in HVHZ and the Wind Borne Debris Region.
Door top rails stamped "HPC". See DWG-MA-WL0191 for
details.
Certification Agency Certificate
FL22363 R3 C CAC NI013717.02-R2.odf
Quality Assurance Contract Expiration Date
05/31/2021
Installation Instructions
FL22363 R3 IT FL 0191.1)df
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22363 R3 AF 514008A.ndf
FL22363 R3 AE 514012A.odf
Created by Independent Third Party: Yes