HomeMy WebLinkAboutSET UP-INSTALLATIONI11 MASONITE. FIBERGLASS DOOR UNIT 6'-B" DOUBLE DOOR WITH / WITHOUT SIDELITES ENS+ERRAL N*�S 1. EVALUATED FOR USE IN LOCATIONS ADHERING TO THE FLORIDA BUILDING CODE AND WHERE PRESSURE REQUIREMENTS AS DETERMINED BY ASCE 7, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, DOES NOT EXCEED THE DESIGN PRESSURES LISTED. . 2. WHEN INSTALLED IN THE HIGH VELOCITY HURRICANE ZONE (HVHZ), HURRICANE PROTECTIVE SYSTEM (SHUTTERS) IS REQUIRED. 3. WHEN INSTALLED IN THE WIND—BORNE DEBRIS REGION, EXCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ), HURRICANE PROTECTIVE SYSTEM IS NOT REQUIRED ON OPAQUE PANELS OR PANELS WITH IMPACT GLASS, BUT IS REQUIRED ON PANELS WITH NON —IMPACT GLASS. 4. POLYURETHANE CORE FLAME SPREAD INDEX OF 50 AND SMOKE DEVELOPED INDEX OF 60 PER ASTM E84. 5. PLASTICS TESTING: •rcr n SELF IGNITION TEMP ASTM D1929 752 'F > 650 'f 842 'F > 6S0 'F RATE OF BURNINGI ASTM D635 1 0.56 IN MIN 1 1.28 IN MIN SMOKE DENSITY ASTM D2843 53.4% 70.2% TENSILE 5MENGTHO ASM DOS 32% DIM 1.8% DIFF B. PLASTICS TESTING OF WORLDWIDE COMPOSITE FRAME (WHERE USED): �I ' ■ ,■ ■I � - lil li 14Y MNf. MV L PKAME WIDTH 21" MAX 36.375" MAX. {— D.L.O. —I PANEL WIDTH 37.5" MAX.. !1 W/ASTRAGAL FRAME WIDTH I 1 m m � CS W J LLL-- SCANNED BY St. Lucie County &je i.49 cuLO N.T.S. � nwG er: SW! q1K 9Y: KURT BALTWOR HRAwiHc No. FLORIDA P.E. pLyp_1yA_TypfB: 156533 6HM T w 6'3• SEE DETAIL 3- 1I��1II— 6' 3• G I 3 •� G 3� G I SEE DETAIL .D• I I I I �6 6'� 6• 6'� I I I I - - w a N q — J w L,it 3'6. 3" -� F #8 x 2" #8x2" d 3' 3• 3" 3' 6" SEE DETAIL 3• 6' #8 x •r ALtlBM,emI6J! JJ10 x 5/8" � c #10 x 5/8" #10 x 2-1/2" #10 x 1 #10 x 1" #10 x 5/8" D AI " " ASTRa ,A ATTACH ASTRAGAL RETAINER BOLT STRIKE PLATE TO FRAME AS SHOWN. a f` n� n EE DETAIL M 6' ASTRAGAL RETAINER BOLT HOLE MUST BE DRILLED THROUGH THE THRESHOLD & INTO THE STRUCTURE DEEP ENOUGH Qi FOR A 1.375" THROW DETAIL "F" ASTRAGAL DETAIL "C" m�'• �"' n"°�"°'m o[cmAmc vmrt a,»• Iva siw¢nam o¢m.,,nr o�i DETAIL "D" ocm swv M+,suo,Ap (rom,.9 mvr sole oA" o-,mu6 tevsnuy nm• wn s:ro mom I.mu mv. a,s"• ma sieacnar® ..2C mv. .L 10.962' a 1.375' 1 � 1.437' T T T INSWING THRESHOLD BUMPER O/S THRESHOLD HE—QZS-IH8E5HOLD TYPICAL GLAZING DETAIL Im —T .BRM1 fLNY. M 1f°f4�4p1/aCFA �q RNA GLAZING MA DM1cENTAWI IMPACT RATED GIMPACT RATED 1.462' 175'2�jj1'047- "r 'e mv. 1.4 7 T T T' mif-: Z—SERIES O/S THRESHOLHIGH DAM O/S THRESHOLD 14Q/S THRESHOLD ALTERNATE GLAZINn DETAI NON -IMPACT GLAce NON-IM_.CT QLAS SWS c w a SEE DEU y 'D' SHT. 3' N e HARDWARE SCHEDULE 1. KWIKSET SERIES 400 GRADE 3 CYLINDRICAL LATCH AND SERIES 980 GRADE 1 DEADLOCK HARDWARE TO BE INSTALLED AT 5-1/2" CENTERLINE. 1 2I5' ., • _ E 2. 4" X 4" FULL MORTISE BUTT HINGES. _ 0.25" MAX 1'XI/2' CORRUGATED p10X2" WOOD SCREW LPH SHIM _ 3' FROM EACH END 6" FROM EACH END I 1L1iN 't AND 7' OC AND 12' OC CL —1- .�,., > — RR RyL • S auTEK �— CL — — CCAAfUI ' TYPICAL MASS ONRY „; aLATEX ANCHOR INSTALLATION CAULK CL 2. ANCHORING INTO STEEL STRUCTURE MUST BE SUFFICIENT TO ACHIEVE 3 THREADS MINIMUM BEYOND STEEL INTERIOR SURFACE. 1X BUCK MASONRY COMBINATION WOOD COMBINATION WOOD 1 so' ANCHOR INSTALLATION MULLION (BOXED) MULLION (BOXED) as SEE DETAIL 'C' SFIT. 2 SEE DETAIL — 3. 'E' SHT. 2 lL 3" T, 6' IL 3' 3' SEE DETAIL 'F' SHT. 2 6" ATTACHMENT DETAIL 1. ANCHOR ANALYSIS FOR LOADING CONDITIONS PREPARED, SIGNED AND SEALED BY ROBERTO LOMAS. PE (FLORIDA #62514) WITH THE LOWEST (LEAST) FASTENER RATING FROM THE DIFFERENT FASTENERS BEING CONSIDERED FOR USE. JAMB, HEAD, AND THRESHOLD FASTENERS ANALYZED FOR THIS UNIT INCLUDE #10 WOOD SCREWS, 1/4" TAPCONS. AND #10 TEK SCREWS. A PHYSICAL SHIM MUST BE PLACED IN SHIM SPACE AT EACH ANCHOR LOCATION. TAPCON EDGE DISTANCE MIN 2-1/2". WOOD SCREW EDGE DISTANCE MIN 3/4". TEK SCREW EDGE DISTANCE MIN 1/2'. 0. THE WOOD SCREW SINGLE SHEAR DESIGN VALUES COME FROM MIN — MAX' (3%& SCREWS• ANSI/AF&PA NDA FOR SOUTHERN PINE LUMBER AND ACHEIVEMENT SHIM OF 1-1/2" MINIMUM EMBEDMENT. THE TAPCON MUST ACHIEVE MINIMUM EMBEDMENT OF 1-1/4". 4. WOOD BUCKS BY OTHERS MUST BE ANCHORED PROPERLY TO TRANSFER LOADS TO STRUCTURE. 5. MINIMUM DESIGN VALUE STRENGTH OF ANCHORS 155 LBS. TYPICAL WOOD BUCK ANCHOR INSTALLATION EACH END INTEGRAL WOOD MULLION (CHS) (4�00IOXD SCREWS EACH END 0 INTEGRAL WW MULLION (CHS) er OF L. Roberto Lomas P. E. `- 1432Woodront Rd. Lewisville, NC 27023 Manufacturer. Masonite Report It. 514010A 434-688-0609 Date: 10/10/2017 rllomasnD ldomasoe.com Test Report: N/A Product: Single door 3' x 68" (Wood Frame) scope: This analysis provides calculations, quantities, and spacing requirements for installing product to substrate, and it applies only to the product described herein. These calculations comply with requirements of the Florida Building Code. Anchor capacity in shear condition: Solid members w/ 6 Weer gap: a. With threads present in shear plane Fastener type: 010 wood screw (NDS 2012, NOS 2015. T1112) Nominal diameter: be 0.190 in sop: g: 0.0000 in Root diameter: Or: 0.152 in Moment arm: ODODO in Minimum required penetration: p: 1,140 in Screw bending yield strength: Fp= 80.000 psi Side member: Douglas Fir-Lorch(6=0.50) Main member: Spruce-Pine-Fir(6=0.42) Side member thickness: 1.= 1,000 in Main member thickness: t•= 1.500 in Side member dowel bearing strength: F,.= 4,650 psi Main member dowel bearing strength: F-= 3,350 psi Side member dowel bearing length: I. = 1.000 in Main member dowel bearing length: IT = 1.140 in Mode I. qm= 636.5 lbs/in P= 725.61 lbs Ka = 2.400 4= 302 lbs Mode I. qs= 884 lbs/in P= 884 lbs 4 = 2AOO Z: 368 the Min Design value: Z= 110 lbs Made II Mode III= Mode IR, Mode IV A: 0.00135 g: 0.000 C: -93.6 P= 263 lbs Ke = 2.400 Ka = 2.400 Duration Factor: Co = 1.6 Z= 124 lbs Z= 133 lbs Z. 110 Ills Allowable Design Value (ZQ: Z.= 175 lbs/anchor Fastener type: 1/41TW Topcon Tabulated values N.O.A. 16-1222.06 Substrate: Hollow black Minimum embedment: 1.25 in Actual edge distance: 2.50 in A: 0.0007 8: 1.07 C:-427.674 P = 331 lbs Ko = 2.400 Z. 138 Ibs A: 0.00096 8: 0.57 C -253.623 Ms = 46.8 in-lbs P = 297 lbs Ko= 2.400 A: 0.00107 8: 0.5 C: -267.699 Moo = 46.8 in-lbs P = 319 Ibs edge (lN Actual C To C spacing: 3.00 in Albwablc Design Value: Z"= 135 lbs/anchor (per Interpolation when needed) Fastener type: #10 Tek screw Substrate: 18 6A, Steel Tabulated design value: Z= 1266 lb, Safety factor: Fs= 4 Allowable Design Value (ZFa): Z.= 316 lbs/anchor Minimum cachor capacity: 155 lbs/anchor Note: Anchors with the least capachyls used for calculagons to quaRlyenchors with highereapachp. Anchor calculations, minimum required anchors 36.38 Design pressure: 85.0 psf �f R1A21 79.25 1 of 3 Max. Archer Area Land Ind. Cap. tity Load Zone (ftt) (Ibs) (in) O.C. Result (in) abs) abs) A, 2.3 195 N/A N/A 1 155 2 98 OK At 7.7 656 6.00 18.00 155 5 131 OK N 11�1 11L I%��l�i •��C E N S�:9cP�'r± * •_ • 0 51 *_ _ .� • TAT OF s/ONAl1?G`�\ Luis R. Lomas P.E. FL No.: 62514 10/10/2017 L. Roberto Lomas P.E. 1432 Wcod/ord Rd Manufacturer: Masonite Lemslne. NC 27023 Report* 514010A 434-68&0609 Date: 10/10/2017 rllomas(c Iriomasoe.com Anchor Locations: 6.001YP. 6.00 t 6° MAX O.C. 79.25 i 6.00 2of3 Luis R. Lomas P.E. FL No.: 62514 10/10/2017 L. Roberto Lomas P. E. 1432 W000roWRa. Manufacturer. Masonite LOWSWIIe. No 27023 Report # 514010A 0. 4-68MW9 Date: 10110/2017 r1lomas,51domasoe. corn Installation instructions: 1. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW. 2. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE'USE 1/4" TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 21/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW. 3. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL WITH 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW. 4. ALL FASTENERS TO BE CORROSION RESISTANT. 5. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW. A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI. C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,000PSI MINIMUM. D. METAL STRUCTURE: STEEL 18GA (.046) FY=33KSI/FU=52KSI OR ALUMINUM 6063-T5 FU=30KSI .052" THICK MINIMUM 6. ANCHOR LOCATIONS SHOWN IN THIS DOCUMENT ARE THE MINIMUM REQUIRED FOR THE DESCRIBED PRODUCT EXPOSED AT THE DESIGN PRESSURE INDICATED HEREIN. 7. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 8. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. 9. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-12" UNITS MUST BE ANCHORED THROUGH FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. 10. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. UNITS MAY BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. 11. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 12. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. 3of3 \\\`\S0//' •�.�G'ENSF9s��� *• 0 51 pTATE OF0. 4. �Z�FS,, G�\�. �s/ONA11i?��x Luis R. Lomas P.E. FL No.: 62514 10/10/2017 L. Roberto Lomas P.E. �- 1 of 3 1432 Woodford Rd. Manufacturer: Masonite Lewisyine, NC 27023 Report #: 514014A 434-688-0609 Date: 10/1012017 r0omaseldomasoe.com Test Report. NIA Producf: Single door 3'x6'8" (Composite frame) Scope: This analysis provides calculations, quantities, and spacing requirements for Installing product to substrate, and it applies only to the product described herein. These calculations comply Wth requirements of the\Flodda Building Code. Anchor capacity in shear condition: Sold members w/ d w/art gap: a. With threads present in shear plane Fastener type: #10 wood screw (Nos 2012, NOS 2015. TR12) Nominal diameter: D: 0.190 in Gap: g: 00000 in Root diameter: or: 0.152 In Moment arm: O.D000 in Minimum required penetration: p: 1.140 in Screw bending yield strength: F,wz 60,000 psi Side member: PVC Main member: Spruce-Pine-Fir(Cr0.42) Side member thickness: t,= 1.000 in Main member thickness: too= 1,500 in Side member dowel bearing strength: F„= 10,ODO psi Main member dowel bearing strength: F,a= 3,350 psi Side member dowel bearing length: I, = 1,000 in Main member dowel bearing length: Ina = 1.140 in Made In Mode I, Made II Mode III. Made III, Made IV qm= 636.51bs/in qs= 1900 lbs/in A: 0.0005 A: 0.00066 A: 0.00092 A: 0.00105 P= 725.61 lbs P= 190016s 8: 07 8: 0.57 8: 0.5 8: 0.000 Ka = 2.400 Ka = 2.400 C.-681.799 C:-253.623 C-521.824 C: -93.6 Zoo= 302 lbs Z,= 792 lbs P= 5101be Ms= 46.8 in-lbs MM= 46.8 in-lbs Ka= 2.400 P= 324 lbs P= 529 lbs P= 299 lbs Min. Design value: Z= 125 lbs Z. 212 lbs Ko= 2.400 Ka= 2A00 Ko= 2AOO Duration Factor: Ca 1.6 Z. 135 the Z. 221 His Z= 125 lb. Allowable Design Value (ZCo): Z.. 199 Ibs/archar Fastener type: 1/4 ITW Tapcm Tabulated values N.O.A. 16-1222.06 edge spac' (in) Substrate: Hollow block distarce 2.00 4.00 Minimum embedment: 1.25 in 2.00 130 161 Actual edge distance: 2.50 in 4.00 163 202 Actual C To C spacing: 3.00 in Allowable Design Value: Z..= 155 lbs/anchor (per Interpolation when needed) Fastener type: #10 Self tapping screw (Calculations per 2015 Aluminum Design Manual, section J.5.5) Nominal screw diameter. D: 0.190 in Screw root arm: Ar 0.0151 in' Actual edge distance: de: 1.085 in Screw shear ultimate strength: Fe, 54.0 ksi Per table J3.2 of 2010 Steal Construction Manual 14th Edition Side member material: Vinyl PVC Main member material: 6063-T5 aluminum Thickness: to 1.000 in Thickness: tc 0.052 in Ultimatetmsilestrength: Fnu 14 ksi Ultimate tensile strength: F,.c 22 loci Nominal strength per bearing (side member): Rn=2Dt,F,�, Art- 5320 lbs (Eq J.542) Nominal strength per bearing (main member): Rn=2DtzF,.z Rai! = 435 lbs (Eq J.5-12) Nominal strength per tilting: An= 4.2(te3D)1`oF,.2 Rn= 478 lbs (Eq J.5-13) Nominal screw shear strength; An=A,F„/1,25 An 654 lbs (Eq J.5-14) Safety factor. n= 3 Allowable shear and bearing capacity: Pa 143 Ibs/amhor Fastener type: #10 Self tapping screw (Calculations per AISI-SI00-12, sections A2.3.2 and E4.3.1) Nominal screw diameter: D: 0.190 in Screw shear ultimate strength: Fa 54.0 ksi Screw root arm: Ar 0.0151 inz Per table J3.2 of 2010 Steel Construction Manual lath Edition Side member material: Vinyl PVC Main member material: Metal framing Thickness: t, 1.000 in Thickness: t2 -A. Ultimate tensile strength: F., 14 mi Ultimate tensile strength: F.z Nominal strength per tilting: Rn=4,2(tz°D)OF,a . \\ An = 1001 lbs (Eq E4.3.1-1) \ R. L / O'Q� Nominal strength per bearing (side member): An = 2.7D1,F,,, Ad - 7182 ibs (Eq E4.3.1-2 and -4) \� J\� .• ♦� •\C Nominal strength per bearing (main member} An = 2.7Dt,Fw Rn2 = 1280 lbs (Eq E4.3.1-3 and -5) • ENS � % Nominal screw shear strength:Rn=A,F„,/1.25 • An 6"lbs • 4C �_ Safety factor a= 3 _� *• 0 51 = * S Allowable shear and bearing capacity: P. 218 Ibs/archor 145Ibs/archor Minimum aced `� TATE OF • �� Note: Anchors with N¢ feast <¢pacay Is used for calcu180¢ns ro quality enGhors with for calculations /nlghar capacity. ��O • is�ONAl0\�`` Luis R. Lomas P.E. FL No.: 62514 10/10/2017 L. Roberto Lomas P. E. 1432 Woodford Rd. Manufacturer. Masonite Lewis✓ille, NC 27023 Report # 514014A 434-688-0609 Date: 10/1012017 r1lomas,'30 lomasoe. corn Anchor calculations. minimum reauiredonchom 36.38 Design pressure: 85.0 psf —f � 2 I 79.25 AM I Anchor Locations: 79.25 2of3 Zone Area (ft') Load (Ibs) Ind. (in) �' O.L. (ln) Anchor Result Lap. (Ibs)Qty Load Obs) A. 2.3 1 111 N/A N/A 145 2 98 OK At 7.7 656 6.00 18.00 145 5 131 OK 36.38 8.19 6.00 TYP. 6.00 TYP. 1 6.00 18' MAX O.C. L i 6.00 �\1R I I `v\SLD \ ,?%r, E V0��-�Y �70 ; TAT OF trr� FS :.Z ORIQP G���� Luis R. Lomas P.E. FL No.: 62514 10/10/2017 L. Roberto Lomas P. E. 1432 WoWord Rd. Manufacturer. Masonite Lewisv le, NC 27023 Report #: 514014A 434-688-0609 Date: 10/10/2017 rllpmaSwlrIomaspe. cam Installation Instructions: 1. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 112" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW. 2. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 1/4" TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 112" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW. 3. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL WITH 112" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW, 4. ALL FASTENERS TO BE CORROSION RESISTANT. 5. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2.000 PSI. C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,000PSI MINIMUM. D. METAL STRUCTURE: STEEL 18GA (.048") FY=33KSI/FU=52KSI OR ALUMINUM 6063-T5 FU=30KSI .052" THICK MINIMUM 6. ANCHOR LOCATIONS SHOWN IN THIS DOCUMENT ARE THE MINIMUM REQUIRED FOR THE DESCRIBED PRODUCT EXPOSED AT THE DESIGN PRESSURE INDICATED HEREIN. 7. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 8. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. 9. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-112" UNITS MUST BE ANCHORED THROUGH FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. 10. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. UNITS MAY BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. 11. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 12. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. 3of3 \\`\\\5 1k I IL 0�1////i •��GENSFgcP�y *• 0,t 51 ••*= oTAT E OF �0260• �i,�/ /JONAL1����`� Luis R. Lomas P.E. FL No.: 62514 10/10/2017