Loading...
HomeMy WebLinkAboutENGINEERINGForensic Agineering Consulbnts, Inc. MEMBRANE ATTACHMENT CALCULATIONS Project Name Liberty Scrap Facility Report No.: ATRT-MB-18.109 Project Address 417 Angle Road Fort Pierce, FL Deck Wood Mean Roof Height 16.0 Feet Configuration rte ow Slope t5coy d Roof Area (Approx.) 5675 Sq.Ft. Category II 8 G0 01 Roof Width 75.5 Feet Exposure Condition C St �UCt6 Perimeter Width 6.0 Feet Building Type Enclosed Parapet Height 1.0 Feet Base Wind Speed 170 mph Corner Zones 6' x 6' Each Slope V 0.0 Slope H 12.0 Slope Angle° 0.00 Uplift Pressures qz = 0.00256 K� Kr Kd V2 P = % (GCP - GCP;) qz K. Kai Kd V GCP GCPi 53.721 0.850 1.005 0.85 170 -1.00 0.18 Field -1.80 0.18 Perimeter -2.80 0.18 Corner Field P1 aii, -63.39 psf P1 asd -38.03 psf Perimeter P2ait.-106.37 psf P2asd -63.82 psf Corner P3an.-160.09 psf P3asd -96.05 psf Proposed System VersiWeld TPO Single Ply Roof Systems Product Approval No. FL14207-R17 (Page 8 of 64) System No. W-20 System Design Pressure -45 psf Membrane Full Width 120 inches Side Lap 5.5 inches Net Width 114.5 inches Membrane Red. Width 63 inches Side Lap 5.5 inches Net Width 57.5 inches Membrane Red. Width 60 inches Side Lap 5.5 inches Net Width 54.5 inches Fasteners Carlisle HP-X Fasteners and Piranha Plates Fastener Spacing in Lap of Membrane 6 inches # Rows 1 Min. Characteristic Resistance Force-214.69 Ibf Fastener Spacing {(MCRF/Pi) x 1441/Row Spacing Membrane Full Width Reduced Width Addl. Reduced Width Field Fastener Spacing 7.10 14.14 14.91 Perimeter Fastener Spacing 4.23 8.42 8.89 Corner Fastener Spacing 2.81 5.60 5.91 RECOMMENDED MEMBRANE FASTENING PATTERN Field Rows (Laps) @ 114.5" o.c. Full Width Membrane 6 inches on center along laps Perimeter Rows (Laps) @ 57.5" o.c. Reduced Width Membrane 6 inches on center along laps Corner Rows (Laps) @ 57.5" o.c. Reduced Width Membrane 5 inches on center along laps These calculations have been done in accordance with ASCE 7-10, based on the information provided by the contractor. The roof system,must be installed in accordance with the FBC & manufacturer's recommendations. Ensure that roof, system meet all life and fire safety requirements of the Florida Building Code, before installation. Sincerely,: -,.. For�ic Engineerigg,Co6s6bnts,, Inc... A>. C R. N. Sailappari;.P.�, (�, •�OI-. Principal Engineer,., Florida Registration No.*46696 , Forensic Engineering Consultants, Inc. (CA # 8265), P.O. Box 970034, Boca Raton, FL - 33497 Ph (561) 901 8490 Fax (561) 218 3830