Loading...
HomeMy WebLinkAboutEVALUATION REPORT0 SCANNED BY St. Lucie County ENGINEER EVALUATE TEST 1I IIATInN RFPOF NEMO I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203)262-9245 CONSULT CERTIFY Versico Roofing Systems Evaluation Report C35230.11.30-R16 P.O. Box 1289 FL14207-1117 Carlisle, PA 17013 Date of Issuance: 11/02/2010 (717) 245-7264 Revision 16: 04/16/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 61h Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: VersiWeld TPO Single Ply Roof Systems LABELING: Labeling shall be in accordance with the requirements of the Accredited. Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO Ietc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOIetc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6, plus a 64-page Appendix. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 iP-:`duo-aataf 'i'• 'a'•'R:--" T�>+ The Facsimile seal appearing was authorized by Robert c.q:e ^+•^E?,q; Nleminen,P.E. on 04/16/2018. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEW ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMOI etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ONEM01eft. ROOFING SYSTEMS EVALUATION: Product Category: Roofing Sub -Category: Single Ply Roof Systems Compliance Statement: VersiWeld TPO Single Ply Roof Systems, as produced by Versico Roofing Systems, have demonstrated compliance with the following sections of the 6" Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind FM 4474 2011 1504.3.1 Wind UL 1897 2012 1504.7 Impact FM 4470 2012 1507.13.2 Physical Properties ASTM D6878 2011 TAS 110 Physical Properties TAS 131 1995 3. REFERENCES: Entity Exam Reference Date Eftfiv Exam Reference Date ACRC(TST4671) Wind 07-051 08/29/2007 FM Apo (TST1867) FM 4474 3017662 06/07/2005 ACRC(TST4671) Wind 07-059 10/15/2007 FM App(TST1867) FM 4474 3023032 07/20/2005 ACRC(TST4671) Wind 10-009 05/19/2010 FM App (TST1867) FM 4474 3018631 11/03/2005 ACRC(TST4671) Wind 10-018 08/25/2010 FM App (TST1867) FM 4474 3023999 11/08/2005 ACRC(TST4671) Wind 10-019 08/25/2010 FM Apo PST1867) FM 4474 3020845 01/25/2006 ACRC(TST4671) Wind 11-034 06/28/2011 FM Apo CM1867) FM 4474 3021941 03/20/2006 ACRC(TST4671) Wind 11-035 06/29/2011 FM App (TST1867) FM 4474 3023340 03/20/2006 ACRC(TST4671) Wind 11-036 06/29/2011 FM App (TST1867) FM 4474 3023458 07/18/2006 ACRC(TST4671) Wind 11-037 06/29/2011 FM Apo (TST1867) FM 4474 3024593 07/27/2006 ACRC(TST4671) Wind 15-002 03/30/2015 FM Apo 0ST1867) FM 4474 3022174 09/25/2006 ACRC(TST4671) Wind 15-008 04/02/2015 FM App (TST1867) FM 4474 3021235 06/01/2007 ACRC(TST4671) Wind 15-009 04/06/2015 FM App (TST1867) FM 4474 3026964 07/25/2007 ACRC(TST4671) Wind 15-011 07/07/2015 FM App M1867) FM 4474 3029438 08/22/2007 ACRC(TST4671) Wind 15-012 07/07/2015 FM Apo (TST1867) FM 4474 3031350 09/27/2007 ACRC(TST4671) Wind 15-015 07/09/2015 FM App(TST3867) FM 4474 3030536 10/09/2007 ACRC(TST4671) Wind 15-016 07/09/2015 FM Apo (TST1867) FM 4474 3028655 11/09/2007 ACRC(TST4671) Wind 15-018 07/10/2015 FM App (TST1867) FM 4474 3026951 01/21/2008 ACRC(TST4671) Wind 15-019 07/14/2015 FM App (TST1867) FM 4474 3031349 OS/13/2008 ACRC(TST4671) Wind 15-020 07/14/2015 FM App (TST1867) FM 4474 3031765 07/21/2008 ACRC(TST4671) Wind 15-021 07/15/2015 FM App (TST1867) FM 4474 3029840 09/08/20D8 ACRC(TSr4671) Wind 15-037 12/28/2015 FM Apo (TST1867) FM 4474 3033217 12/08/2008 ACRC(TST4671) Wind 15-038 12/28/2015 FM App (TST1867) FM 4474 3034985 12/15/2008 ACRC(TST4671) Wind 15-041 12/30/2015 FM App (TST1867) FM 4474 3034066 04/14/2009 ACRC(TST4671) Wind 15-043 01/04/2016 FM App (TST1867) FM 4474 3034776 08/07/2009 ACRC(TST4671) Wind 15-045 01/11/2016 FM Ara(TSr1867) FM 4474 3037400 09/02/2009 ACRC(TST4671) Wind 15-046 01/11/2016 FM App (TST1867) FM 4474 3033356 10/09/2009 ACRC(TST4671) Wind 15-047 01/12/2016 FM App (TST1867) FM 4474 3034297 11/13/2009 AT (TST1588) FM 4470 01-37050.01 03/13/2000 FM App (TST1867) FM 4474 3040639 08/11/2010 An (TST1588) FM 4470 01-39152.01 03/28/2001 FM App (TST1867) FM 4474 3036762 03/08/2011 An(T5T1588) Physicals 01-37490.01 OS/26/2004 FM App(TST3867) FM 4474 3041535 06/08/2011 An (TSr1588) FM 4470 63524.01-111-47 03/1612D06 FM App (TST1867) FM 4474 3039340 06/24/2011 An (TST1588) FM 4470 76506.01-111.47 09/06/2007 FM App (TST1867) FM 4474 3043858 08/25/2011 An (TSr1588) FM 4470 77891.01-111-47 10/26/2007 FM App (TST1867) FM 4474 3041797 10/13/2011 An (TST1588) FM 4474 C1141.01-309-18 09/13/2012 FM App (TST1867) FM 4474 3039073 11/22/2011 An (TST3588) TAS 114 D7772.01-109-18 07/09/2014 FM App 0 ST1867) FM 4470 1%9A4.AM 12/06/2011 AM (TST1588) TAS 114 D7772.02-109-18 07/14/2014 FM App (TST1867) FM 4470 3000919 12/06/2011 An (TST1588) TAS 114 E4981.01-10948 02/26/2015 FM App (TST1867) FM 4470 3041535 12/06/2011 CrL (TST3577) FM 4474 CrLA-10511 10/13/2008 FM App (TST1867) FM 4470 3044748 12/06/2011 CrL (TST1577) FM 4474 CTLA-105R.1 10/13/2008 FM App (TST1867) FM 4474 3040260 02/27/2012 Cn(TST1577) FM 4474 CTLA-305R-2 10/13/2008 FM App(TST1867) FM 4474 3041799 03/29/2012 CTL(TSTI577) FM 4474 ULA-106R 10/16/2008 FM App(TST1867) FM 4474 3043824 04/06/2012 CTL'(TST1577) FM 4474 CTLA-106R-1 10/16/2008 FM App (TST1867) FM 4474 3039762 09/07/2012 CrL(TST1577) FM 4474 CTLA-106R-2 30/16%2008 FM App (TST1867) FM 4474 3047327 09/13/2012 CTL(TST1577) FM 4474 CrLA-106R-3 30/16/2008 FM App (TST1867) FM 4474 3040639 09/18/2012 CrL(TST1577) FM 4474 CTLA-106R-4 10/16/2008 FM App (TST1867) FM 4474 3043858 09/25/2012 NEMO ETC, LLC Evaluation Report C35230.11.10-RS6 certificate ofAWhorizatian#32455 fir" EDITION (2017) FBC NON-HVHZ EVALUATION FL34207-R17 VersiWeld TP051ngle Ply Roof Systems Revision 16: 04/16/2018 Page 2 of S NNEMOjetc. Entity Exam Reference Date Entit Exam Reference Date CrL (TST1577) TAS 117 CTLA 111R 01/13/2009 FM Apo (TSr1867) FM 4474 3042075 10/23/2012 ERD (TST 6049) Physicals U0215.05.06.1 05/30/2006 FM Apo ITST1867) FM 4474 3049189 03/11/2014 ERD (TST 6049) FM 4470 E9490.03.08 03/25/2008 FM App(TST3867) FM 4474 3048753 09/16/2014 ERD (TST 6049) Physicals C32760.01.11 01/19/2011 FM App(T5T3867) FM 4474 3051392(data) 10/15/2014 ERD (TST 6049) Physicals A35880.04.12-111 10/26/2012 FM Apo(TST1857) FM 4474 3054838 02/13/2015 ERD (TST 6049) Physicals C46470.07.14-1A 07/16/2014 FM Apo(TST3867) FM 4474 3OS5462 04/01/2015 ERD (TST 6049) Physicals C46470.07.14-18 07/16/2014 FM App (TST3867) FM 4474 3050229 01/25/2016 ERD (TST 6049) Physicals C46470.07.14-4-R1 07/21/2014 FM App(TST1867) FM 4474 3058125 02/04/2016 ERD (TST 6049) Physicals C4647D.07.14-2A 07/30/2014 FM App (TST3867) FM 4474 3055167 02/10/2016 ERD (TST 6049) Physicals C46470.07.14-2B 07/30/2014 FM App (TST3867) FM 4474 RR206411 09/26/2018 ERD (TST 6049) FM 4474 SCI0010.02.16 02/29/2016 FM Apo(TST3867) FM 4474 3056745 09/28/2016 ERD (TST 11294) FM 4474 13380.01.17 01/27/2017 FM App (TST1857) FM 4474 3058125 12/06/2016 ERD (TST 6049) FM 4474 CRL-SC33450.01.17 01/31/2017 FM App (TST1867) FM 4470 3063373(date) 10/10/2017 ERD (TST 6049) Physicals CRL-SC14240.17 03/21/2017 FM Apo(TST3867) FM 4474 3063373(data) 11/07/2017 ERD (TST 11294) FM 4474 CLT36160.08.17-1 09/28/2017 FM Apo(TST3867) FM 4474 PR449852(data) 03/29/2018 ERD (TST 11294) FM 4474 CLTI6160.08.17-2 08/28/2017 M-D(CER3592) Wind Uplift 12-0216.01 03/08/2012 FM App(TST3867) FM 4470 3Z9A1.AM 10/15/1997 M-D(CER1592) Wind Uplift 13-0617.20 09/05/2013 FM Apo(TST3867) FM 4470 3001580 11/16/1998 M-D(CER1592) Wind Uplift 13-0307.02 09/26/2013 FM Apo(TST1867) FM 4470 3DO1522 03/26/1999 NEMO(TST 6049) FM 4474 2-CRL-18-002 03/14/2018 FM Apo(TST1867) FM 4470 3DO3393 03/30/1999 NEMO(TST 11294) FM 4474 4-CRL-18-003 03/22/2018 FM App(TST3867) FM 4470 3DO3337 06/11/1999 NEMO(TST 6049) Physicals 4-CRL-18-002.04.18.1 04/03/2018 FM Apo(TST3867) FM 4470 3006110 06/13/2001 NEMO(TST 6049) Physicals 4-CRL-18-002.04.18-2 04/03/2018 FM Apo(TST1867) FM 4470 3011329 06/10/2002 NEMO(TST 6049) Physicals 4-CRLA8-002.0418-2A 04/03/2018 FM Apo CM1867) FM 4470 3012879 04/04/2003 NEMO(T5T 6049) FM 4474 2-CRL-18002 04/13/2018 FM App (TST3867) FM 4470 3013584 06/27/2003 Pit I CMT(TST5878) FM 4474 CST.016-02-01 05/04/2011 FM App(TST3867) FM 4470 3014692 08/05/2003 Pit I CMT(TST5878) FM 4474 CST-016.02-01 05/05/2011 FM App(TST3867) FM N170 3016355 09/15/2003 UL, LLC(TST9628) UL1897 08CA15815 10/22/2008 FM App (TST3867) FM 4470 3019890 12/16/2004 UL, U.C. (QUA9625) QC Inspection (MS) 06/01/2017 The following roof covers are mechanically attached or fully adhered to Approved substrates using fasteners, stress plates and adhesives, as outlined in the Limitations / Conditions of Use herein. 4.1 VersiWeld Reinforced TPO Membrane are nominal 45-mil (1.1-mm) or 60-mil (1.5-mm) thick, polyester -scrim reinforced, thermoplastic olefin (TPO) single -ply roof membranes; meets ASTM D6878-11 & TAS 131. 4.2 VersiWeld Plus Reinforced TPO Membrane are nominal 72-mil (1.8-mm) or 80-mil (2.0-mm) thick, polyester -scrim reinforced, thermoplastic olefin (TPO), single -ply roof membranes; meets ASTM D6878-11 & TAS 131. 4.3 VersiWeld HS/ES Reinforced TPO Membrane are nominal 60-mil (1.5-mm) thick, polyester -scrim reinforced, thermoplastic olefin (TPO) single -ply roof membranes; meets TAS 131. 4.4 VersiFleece FIR TPO membrane is a variation of VersiWeld Reinforced TPO Membrane 60-mil (1.5 mm), but with a carbon -fiber fleece on the back side for fire -rating considerations over wood deck; meets ASTM D6878-11 & TAS 131. 4.5 VersiFleece TPO 100, TPO 115 or TPO 135 membranes are nominal 45-mil (1.1-mm), 60-mil (1.5-mm) or 80-mil (2.0- mm) thick, respectively, polyester -scrim reinforced, thermoplastic olefin (TPO) single -ply roof membranes with a polyester fleece backing; meets ASTM D6878-11 & TAS 131. 4.6 VersiFleece AC TPO 120, AC TPO 135 or AC TPO 155 membranes are nominal 45-mil (1.1-mm), 60-mil (1.5-mm) or 80-mil (2.0-mm) thick, respectively, polyester -scrim reinforced, thermoplastic olefin (TPO) single -ply roof membranes with a polyester fleece backing formulated for hot asphalt application; meets ASTM D6878-11 & TAS 131. 4.7 VersiWeld QA TPO membrane is a nominal 60-mil (1.5-mm) thick, polyester -scrim reinforced, thermoplastic olefin (TPO) single -ply roof membrane laminated to an elastomeric pressure -sensitive adhesive; meets TAS 131. NEMO ETC, LLC Evaluation Report C35230.11.10-R16 Certificate ofAulhonzatlon N32455 0 EDITION (2017) FBC NON-HVHZ EVALUATION FL14207-R37 VersiWeld TPO Single Ply Roof Systems Revision 16: 04/16/2019 Page 3 of 5 ONEMOletc. 5.1 This is a building code evaluation. Neither NEM01etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in HVHZ jurisdictions. 5.3 Refer to a current LIL Roofing Materials Directory for fire ratings of this product. 5.4 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply. 5.5 The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5.6 For recover installations, the existing roof shall be examined in accordance with FBC 1511. 5.7 For mechanically attached insulation or membrane or strip -bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD3, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk' carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.8 For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 5.9 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 5.10 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.11 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 5.12 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or Roofing Application Standard RAS 111, except the basic wind speed shall be determined from FBC Figure 1609.3(1), 1609.3(2) or 1609.3(3). 5.13 All products in the roof assembly shall have quality assurance in accordance with FAC Rule 61G20-3. NEMO ETC, LLC Evaluation Report C35230.11.10-R36 Certi(cate of Authorization H32455 61e EDITION 12017) FBC NON-HVHZ EVALUATION FL14207-R17 VersiWeld TPO Single Ply Roof Systems Revision 16: 04/16/2018 Page 4 of 5 r ONEMOletc. 6.1 VersiWeld TPO Single Ply Roof Systems shall be installed in accordance with Versico Roofing Systems published installation instructions, subject to the Limitations / Conditions of Use noted herein. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. 6.2 For mechanically fastened membrane systems (Type D) over profiled steel deck, membrane shall be installed running perpendicular to steel deck flutes. As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. Contact the noted CA agency for information on product locations covered by CIA procedures in accordance with FAC Rule 61G20-3. 9. QUALITY ASSURANCE ENTITY: UL, LLC—QUA9625; (414) 248-6409; karen.buchmann@ul.com -THE 64-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT - NEMO ETC, LLC certificate of Authorization N32455 6- EDITION (2017) FBC NON.HVHZ EVALUATION VersiWeld TPO Single Ply Roof Systems Evaluation Report C35230.11.10-R36 F1.34207-1117 Revision 16:04/16/2019 Page 5 of 5 NNEMOletc. TABLE DECK APPLICATION TYPE DESCRIPTION PAGE 3A Wood New. Reroof Rear-OfFl. Recover C-1 Mechanically Attached Insulation. Bonded Roof Cover 5 iB Wood New, Reroof (Tear -Off), Recover C-2 Mechanically Attached Insulation, Plate -Bonded Roof Cover 6 1C Wood New, Reroof (Tear -Off), Recover D-1 Insulated, Mechanically Attached Roof Cover 7 1D Wood IE Wood New. Reroof (Tear -Off). Recover E-1 Non -Insulated. Mechanically Attached Roof Cover 8 IF Wood New, Reroof (Tear -Off), Recover E-2 Non -Insulated, Mechanically Attached Base Sheet, Bonded Roof Cover 8 SG Wood New, Reroof (Tear -Off), Recover G Optional Insulation, Loose -Laid Roof Cover, Pressure Equalizing Vent 8 2A Steel or Structural Concrete New, Reroof (Tear -Off), Recover B-1 Mach. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 9-12 2B Steel or Structural Concrete New, Reroof (Tear -Off), Recover B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Base Ply, Bonded Roof Cover 13 2C Steel New, Reroof (Tear -Off), Recover B-2 Mech. Attached Thermal Barrier, Bonded Vapor Barrier, Bonded Insulation, Bonded Roof Cover 14-15 2D Steel or Structural Concrete New, Reroof (Tear -Off), Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 16-22 2E Steel or Structural Concrete New, Reroof (Tear -Off), Recover C-1 Mechanically Attached Insulation, Bonded Base Ply, Bonded Roof Cover 23 2F Steel New, Reroof (Tear -Off), Recover C-2 Mechanically Attached Insulation, Plate -Bonded Roof Cover 24-25 2G Steel or Structural Concrete New, Reroof (Tear -Off), Recover D-1 Insulated, Mechanically Attached Roof Cover (Stress Plates) 26-31 2H Steel or Structural Concrete New, Reroof (Tear -Off), Recover D-2 Insulated, Mechanically Attached Roof Cover (RUSS Strips) 32 3A Structural Concrete New, Reroof (Tear -Off) A -IA Bonded Insulation, Bonded Roof Cover 33-41 3B Structural Concrete New, Reroof (Tear -Off) A -IA Bonded Insulation, Bonded Base Ply, Bonded Roof Cover 42 3C Structural Concrete New, Reroof (Tear -Off), Recover C-2 Mechanically Attached Insulation, Plate -Bonded Roof Cover 43-44 3D Structural Concrete New, Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 45 3E Structural Concrete New, Reroof (Tear -Off), Recover G Optional Insulation, Loose -Laid Roof Cover, Pressure Equalizing Vent 45 4A LWIC New, Reroof (Tear -Off) A-1A Bonded Insulation, Bonded Roof Cover 46 4B LWIC New, Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 46 4C LWIC over Steel New, Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 47-49 4D LWC over Structural Concrete New, Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 5011 5A CWF New, Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 52 6A Gypsum Reroof(Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 53-54 68 Gypsum Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 54 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 55-57 7B Various Recover A-1 Bonded Insulation, Bonded Base Ply, Bonded Roof Cover 58 7C Steel Recover C-2 Mechanically Attached Insulation, Plate -Bonded Roof Cover 59 7D Steel Recover D-1 Insulated, Mechanically Attached Roof Cover 60 7E Steel Recover D-2 Insulated, Mechanically Attached Roof Cover(RUSS Strips) 61 7F Various Recover E-1 Non -Insulated, Mechanically Attached Roof Cover 62 7G Various Recover F-1 Non -Insulated, Bonded Roof Cover 63 7H Various Recover F-2 New LWC over Existine Roof, Bonded Roof Cover 64 NEMO ETC, LLC Evaluation Report C35230.11.10-R16 for FL34207-R17 Certificate of Authorization #32455 6- EDITION (2017).FBC NON-HVHZ EVALUATION Revision 16: 04/16/2018 Prepared by: Robert Nieminen, PE-59166 VersiWeld TPO Single Ply Roof Systems; (717) 245.7264 Appendix 1, Page 1 of 64 NNEMOjetc. The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Unless otherwise noted, fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements: D Wood Deck: HPV Fastenerwith HPV Insulation Fastening Plate (aka, Versico's Insulation Fastening Plate). Minimum 1-inch wood penetration. D Steel Deck: HPV Fastenerwith HPV Insulation Fastening Plate (aka, Versico's Insulation Fastening Plate). Minimum %-inch steel penetration, engage the top flute of the steel deck. D Concrete Deck: MP 14-10 Concrete Fastener, CD-10 Concrete Fastener or MP Concrete Spike with HPV Insulation Fastening Plate (aka, Versico's Insulation Fastening Plate). Minimum 1-inch embedment. - Fasteners installed with a pilot hole in accordance with the fastener manufacturer's published installation instructions. 3. Unless otherwise noted, insulation may be any one layer or combination of polyisoc/anurate, polystyrene, fiberboard, perlite and/or gypsum -based insulation board that meets the OA requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. 4. Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type C-2 (plate bonded roof cover) or Type D (mechanically attached membrane), whereby the membrane fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater type, thickness and strength to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5. Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016) using fasteners & plates from Note 2. Vemico Insultite Fastener may be used in place of HPV Fastener for preliminary attachment purposes over wood and steel deck. 6. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published instructions D Hot asphalt: FULL -coverage at 25 lbs/square. ➢ FAST 100, DASH 100-LV (FULL): FULL -coverage at 1 gal./square. D FAST 100, DASH 100-LV (RIBBON): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. D DASH 5-Gallon Jug Adhesive (DASH 5-GJA): Continuous 0.75 to 1-inch wide ribbons,12-inch o.c. D DASH Dual Cartridge (DASH DC): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. D DASH Dual Tank (DASH DT)(FULL): Continuous 0.5-Inch wide, wet -beads, 4-inch o.c. D DASH Dual Tank (DASH DT) (RIBBON): Continuous 0.5-inch wide, wet -beads, 12-inch o.c. Note: When installing multiple layers of insulation, DASH Dual Tank beads shall be placed perpendicular to those placed for attachment of the previous layer. D Flexible DASH (FULL): FULL -coverage at 1 gal./square. D Flexible DASH (RIBBON): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. • ➢ Flexible DASH Dual -Tank (Flexible DASH DT) (RIBBON): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. ➢ OlyBond S00 BA (OB500): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. using PaceCart or SpotShot. Note: OlyBond 500 Green may be used where OlyBond 500 is referenced. ➢ Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon -applied adhesive, boards shall be staggered from layer -to -layer. ➢ Note: The maximum edge distancefrom the adhesive ribbon to the edge of the insulation boardshall be not less than one-half the specified ribbons spacing. 7. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations maybe substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to 'Increase the MDP listings in the tables; rather if MOP listing below meets or exceeds that listed fora particular system in the tables, then the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table: D FAST 100, DASH 100-LV or Flexible DASH: MDP -157.5 psf (Min. 0.5-inch thick) D OlyBond 500 BA (OB500): - MDP -187.5 psf (Min. 0.5-inch thick) 8. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. 9. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD3, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk' carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. NEMO ETC, LLC Evaluation Report C35230.11.1D-R16 for FL14207-R17 Certificate of Authorization #32455 61e EDITION (2017) FBC NON-HVHZ EVALUATION Revision 16: 04/16/2018 Prepared by: Robert Nieminen, PE-59166 VersiWeld TPO Single Ply Roof Systems; (717) 245-7264 Appendix 1, Page 2 of 64 ONEMOletc. 10. For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted. 11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TA5 105. 12. For existing substrates in a bonded recover or re -roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TA5 124. 13. For System Type D, steel deck applications, the roof membrane shall be run with its length perpendicular to the steel deck flutes. 14. For Structural Concrete Deck or Recover Applications using System Type C-2 (Plate Bonded Roof Cover) or Type D (Mechanically Attached Roof Cover), the insulation is optional. Alternatively, min. 0.5-inch Versico _ Recovery Board, SecurShield HD or H-Shield HD or min. 0.25-inch to 0.625-inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum -Fiber Roof Board or SECUROCK Glass -Mat Roof Board or min. 3/8-Inch Insulfoam R- Tech EPS or Fan -Fold may be used as a separator board, preliminarily attached prior to roof cover installation. The separator component shall be documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover in Recover applications. 15. Lightweight Insulating Concrete (LWC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced, refer to current LWC Product Approval for specific deck construction and limitations. For systems where specific LWC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat thickness is 2-inches. For LWC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. 16. For adhered membrane systems, side laps shall be minimum 2-inch wide sealed with min. 1.5-inch heat weld. Unless otherwise noted, membrane adhesive application rates are as follows: MEMBRANE ADHESIVE ETHOD RATE VersiWeld or VersiWeld HS/ES Reinforced TPO Membrane VersiWeld Bonding Adhesive (both sides) 60 ft2/gal VersiWeld or VersiWeld HS/ES Reinforced TPO Membrane Aqua Base 120 Bonding Adhesive (both sides) 120 ft2/gal VersiWeld or VersiWeld HS/ES Reinforced TPO Membrane Low VOC Bonding Adhesive (both sides) 60 ft2/gal VersiWeld or VersiWeld HS/ES Reinforced TPO Membrane Sure -Seal 90-8-30A Bonding Adhesive (both sides) 60 ft2/gal VersiWeld Reinforced TPO Membrane CAV-GRIP 3V Low-VOCAdhesive/Primer (both sides) P 110 ft2/gal VersiFleece TPO Aqua Base 120 Bonding Adhesive (substrate) 120 ft2/gal VersiFleece TPO HydroBond Water -Based Adhesive (substrate) 100 to 133 ft2/gal VersiFleece TPO FAST 100, DASH 300-LV, DASH DC, DASH DT, Flexible DASH or Flexible DASH DT (substrate) RIBBON spaced as noted herein or FULL Coverage =1 gal/square or continuous ribbons, maximum 4-inch o.c. VersiFleeceACTPO Versico Cold Applied Adhesive (V-CAA) (substrate) 1.5 gal/square VersiFleece ACTPO Hot asphalt I Wet lay (substrate) 25 lbs/square 17. For membrane systems attached using TPO 10-inch Pressure -Sensitive RUSS, the underside of the membrane which comes in contact with the tape shall be primed with TPO Primer. The membrane shall be secured by placing the primed portion onto the tape portion of the VersiWeld TPO 10-inch Pressure -Sensitive RUSS and roll with a steel hand roller to ensure contact. 18. For adhered membrane systems, unless otherwise noted: ➢ Reference to "VersiWeld" (VersiWeld Reinforced TPO Membrane) below also includes VersiWeld Plus Reinforced TPO Membrane or VersiWeld HS/E5 Reinforced TPO Membrane.; ➢ Reference to "VersiFleece" (VersiFleece TPO) includes TPO 100, TPO 115 and TPO 135; ➢ Reference to "VersiFleece AC" (VersiFleece AC TPO) Includes AC TPO 120, AC TPO 135 and AC TPO 155. NEMO ETC, LLC Evaluation Report C35230.11.10-1116 for FL14207-R17 Certificate of Authorization #32455 6" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 16: 04/16/2018 Prepared by: Robert Nieminen, PE-59165 VersiWeld TPO Single Ply Roof Systems; (717) 245.7264 Appendix 1, Page 3 of 64 is 19. Vapor barrier options for use over structural concrete deck followed by adhesive -applied Insulation carry the following Maximum Design Pressure (MDP) limitations. Table 3A or 3B applies. fONEMojetc. The lesser of the MDP listings below vs. those in VAPOR BARRIER O. DECK; FOLLOWED Option# Primer - Vapor Barrier Insulation Adhesive MOP(psf) Type Application VB-1. 702 Primer Versico 725TR Self -adhering DASH 100-LV, FULL -coverage at 1 gal/square. -67.5 VS-2. 702 Primer Versico 725TR Self -adhering 'DASH 300-LV, DASH 5-Gallon Jug Adhesive (DASH 5-GJA) or DASH DC (RIBBON, 12-inch D.C.) -67.5 VB-3. 702 LV Primer Versico 725TR Self -adhering DASH 100-LV, FULL -coverage at 1 gal/square. -97.5 VB-4. 702 LV Primer Versico 725TR Self -adhering DASH 100-LV, DASH 5-Gallon Jug Adhesive (DASHS-GJA) or DASH DC (RIBBON, 12-inch D.C.) -97.5 VB-S. CAV-GRIP Primer Versico 725TR Self -adhering DASH 100-LV, FULL -coverage at 1 gal/square. -127.5 VB-6. CAV-GRIP Primer Versico 725TR Self -adhering DASH 100-LV, DASH 5-Gallon Jug Adhesive (DASH 5-GJA) or DASH DC (RIBBON,12-inch D.C.) -127.5 VB-7. ASTM D41 SureMB 90TG Base Torch -applied DASH 100-LV or DASH DC (RIBBON, 12-inch D.C.) -165.0 VB-B. ASTM D41 SureM690.Base Hot -asphalt Hot asphalt at 251bs/square -172.5 VB-9. ASTM D41 SureMB 90TG Base Tarch-applied Hot asphalt at 25 Ibs/square -180.0 20. "MDP" = Maximum Design Pressure Is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. • NEMD ETC, LLC Evaluation Report C35230.11.10-R16 for F1.14207-1117 Certificate of Authorization #32455 6- EDITION (2017) FBC NON-HVHZ EVALUATION Revision 16: 04/16/2018 Prepared by: Robert Nieminen, PE-59166 VersiWeld TPO Single Ply Roof Systems; (717) 245-7264 Appendix 1, Page 4 of 64 C NNEMOjetc. TABLE IE: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPE E-1: r MECHANICALLY ATTACHEDRO Thermal Barrier Roof Cover SMDP ystem em Type Attach Membrane Fasteners Fastener Lap Width Lap Spacing Seam Weld Deck (Note 1) Po) Spacing (Optional) Any VersiWeld, min. 60- Min. inch COX or Loose- 114.5-inch W 19 approved mil or VersiFleece HPV-X Fasteners and HPV-X Plates 12-inch o.c. 5.5-inch 22 5 wood plank plank laid O.C.ut ut outside side thermal barrier FR TPO (Optional) Any VersiWeld, min. 60- Min. 19/32-inch COX plywood or Loose- 114.5-inch 1.5-inch W20 approved mil or VersiFleece HPV-X Fasteners and HPV-X Plates 6-inch o.c. 5.5-inch -45.0 wood plank thermal barrier laid FR TPO O.C. outside Min. 19/32-inch COX plywood or (Optional)Any Loose- VersiWeld, min. 60- 1.5-inch W-21 wood plank at max. 24-inch spans; approved laid mil HPV-XL Fasteners and HPV-XL Plates 12-inch o.c. 5.5-inch 90.5-inch o.c. outside -45.0 Ed ring shank nails, 6-inch o.c. thermal barrier HPV-X Fasteners and HPV-x Plates Min. 19/32-inch plywood at max. (Optional) Any or #15 Roofgrip with 2-3/8" Eyehook 48-inch o.c. Loose- 1.5-inch W-22 24-inch spans; 8d ring shank nails, approved VersiWeld Seam Plates (AccuSeam) installed 6-inch o.c. 5.5-inch (overstrucural -75.0 6-inch o.c. thermal barrier laid through wood sheathing to engage members) outside structural members TABLE 1F: WOOD DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPE E-2: NON -INSULATED, MECHANICALLY ATTACHED BASE SH EET, BONDED ROOF COVER System Thermal Barrier Base Sheet Roof Cover No. Deck (Note 1) Type Attach Base Sheet Fasteners Attach Membrane Adhesive MOP (psf) Min. 19/32-inch plywood at (Optional) Any Atlas Summit Versico Insultite 12-inch o.c. at the 4-Inch laps W-23 max. 24-inch spans; #10 x 2- approved Loose -laid Synthetic and Versico Seam and 12-inch o.c. at three, VersiWeld OA TPO Self -adhered -120.0 inch wood screws, 6-inch o.c. thermal barrier Underlayment Fastening Plates equally spaced rows in the center of the sheet. NEMO ETC, LLC Evaluation Report C35230.11.10-R16 for FL14207-R17 Certificate of Authorization #32455 6- EDITION (2017) FBC NON-HVHZ EVALUATION Revision 16; 04/16/2018 Prepared by: Robert Nieminen, PE-59166 VersiWeld TPO Single Ply Roof Systems; (717) 245-7264 Appendix 1, Page 8 of 64