HomeMy WebLinkAboutFIELD WITHDRAWAL RESISTANCE TEST RESULTS REPORTMj-daaq TESTING APPLICATION STANDARD (TAS) 105 APPENDIX A FLORIDA BUILDING CODE FIELD WITHDRAWAL RESISTANCE TEST RESULTS REPORT Test Date: December 2"d. 2018 F I L E COPY File #: 1923-18 GENERAL INFORMATION Job Name: Libertv ScraD Facilitv — Area A. B and C. Job Address: 417 Angle Road. SCANNED BY Fort Pierce, Florida St. LUC e County Job Contact: -Tim Sutton — The Roof Authority TESTING AGENCY AND EQUIPMENT INFORMATION Note: The Undersigned representative agrees that all testing has been conducted and results have been reported in compliance with Florida Building Code TAS 105 or TAS 105 A. Testing Agency Name: Address: Telephone: Fax: Lab Contact: Report Review: Title: A. Tomassi Roof Testing, Inc. 5451 NW 240' Street. Suite # 3 Margate, Florida 33063 (954) 979 - 1180 (954) 979 - 1182 Anthony Tomassi it C•���i ��.. �' o .. .- Signature: s.r. Test Apparatus: DMD PFT — 2000A " - > '" a• ' s� .... ,. Dade County Certified Testing Agency # 17-0719.01 Revises # 03-0317.03` " Dominick Scarfo Architect, AR0010248 Page — 1 Building and Roof System Information Area = A Height =12' ft Ht. approx. Length = 63' approx. Second largest dimension = 49' approx. Total roof area = 2,000 square feet approx. Perimeter Area = 865 square feet approx. ►YMM.1 Height =16' ft Ht. approx. Length = 49' approx. Second largest dimension = 40' approx. Total roof area =1,960 square feet approx. Perimeter Area = 712 square feet approx. Area = C Height =14' ft Ht. approx. Length = 49' approx. Second largest dimension = 35' approx. Total roof area =1,715 square feet approx. Perimeter Area = 588 square feet approx. Page 2 FASTENER INSTALLATION INFORMATION: Is the fastener a self — driller ? Yes If `yes' list the type of tool used for installation: Craftsman Speed of Tool 0 —2,000 RPMs TEST INFORMATION: Number of Tests Conducted: n = 24 • See Section 7 of Dade County PA 105 or PA 105A • Note the locations of all tests on `Building Information' Detail # 2 Attached Page 3 FIELD WITHDRAWAL RESISTANCE TEST RECORDING SHEET Area = A Component to be secured: Insulation Existing Roof Membrane Anchor or Base Sheet Wood Blocking Metal Profiles Fastener Type: HPX Fasteners MFGR. Verisco Deck Type: Wood Pre —Drilled No Drill Bit Size N/A Hole Depth N/A Sample No. Plan Identifier Initial Failure Load 16 Field Test Area Perimeter Test Area Corner Test Area #1 same 674 X #2 538 X #3 562 X #4 165 X #5 658 X #6 549 X #7 665 X #8 1139 X Page 4 STATISTICAL ANALYSIS Mean Failure Load: Sample Standard Deviation: Minimum Characteristic Resistance Force: Area = A F = 618.75 lbf Sf = 249.47 lbf F'= 410.18 lbf Notes: 1. Use the results herein to determine the required number of fasteners for insulation attachment or an acceptable anchor or base sheet fastener spacing, as outlined on FLORIDA BUILDING CODE TAS —117, Shall utilize the minimum characteristic force (F'), determined in compliance with section 8 of TAS 105. No margin of safety shall be applied to field withdrawal resistance test results determined in compliance with TAS 105 or TAS 195(A) 2. A safety factor of 2 to 1 shall be applied to laboratory testing. 3. The following pages shall be completed for each roof area and included with all Field Withdrawal Resistance Test Recording Sheets. Notes: ROOF AREA = A Insert Building and Parapet Heights. Paz` &on If no Parapet exists, insert ("N/A") GROUND LEVEL Building Information — Detail # 1 Page 5 Note: All Dimensions are Approximate —Drawing NTS ,ATRT Title A. Tomassi Roof Testing, Inc. 5451 NW 24TR Street, Suite # 3 Margate, Florida 33063 Project: Project No. 1923-18 SCANNED BY St. Lucie County Fastener Withdrawal Test Area A Liberty Scrap Facility 417 Angle Road Fort Pierce, Florida Drawn Sheet No. D.G.Z 1 of 3 TAS.105 - Test locations T = Tested Locations FIELD WITHDRAWAL RESISTANCE TEST RECORDING SHEET Area = B Component to be secured: Insulation Existing Roof Membrane Anchor or Base Sheet Wood Blocking Metal Profiles Fastener Type: HPX Fasteners MFGR. Verisco Deck Type: Wood Pre — Drilled No Drill Bit Size N/A Hole Depth N/A Sample No. Plan Identifier Initial Failure Load lb Field Test Area Perimeter Test Area Corner Test Area #1 same 446 X #2 542 X #3 459 X #4 500 X #5 543 X #6 954 X #7 429 X #8 724 X Page 4A STATISTICAL ANALYSIS Mean Failure Load: Sample Standard Deviation: Minimum Characteristic Resistance Force: Area = B F = 574.63 lbf Sf= 167.70 lbf F'= 434.42 lbf Notes: 4. Use the results herein to determine the required number of fasteners for insulation attachment or an acceptable anchor or base sheet fastener spacing, as outlined on FLORIDA BUILDING CODE TAS —117, Shall utilize the minimum characteristic force (F'), determined in compliance with section 8 of TAS 105. No margin of safety shall be applied to field withdrawal resistance test results determined in compliance with TAS 105 or TAS 195(A) 5. A safety factor of 2 to 1 shall be applied to laboratory testing, 6. The following pages shall be completed for each roof area and included with all Field Withdrawal Resistance Test Recording Sheets. Notes: FITSTOWTITEW Insert Building and Parapet Heights. If no Parapet exists, insert ("N/A") GROUND LEVEL Information — Detail # 1 Page 5A Note: All Dimensions are Approximate —Drawing NTS 49' ATRT I Title Fastener Withdrawal Test Project: A. Tomassi Roof Testing, Inc. 5451 NW 20n Street, Suite # 3 Margate, Florida 33063 Project No. 1923-18 Area B Liberty Scrap Facility 417 Angle Road Fort Pierce, Florida Drawn Sheet No. D.G.Z 2 of 3 TAS 105 - Test locations T = Tested Locations FIELD WITHDRAWAL RESISTANCE TEST RECORDING SHEET Area = C Component to be secured: Insulation Existing Roof Membrane Anchor or Base Sheet Wood Blocking Metal Profiles Fastener Type: HPX Fasteners MFGR. Verisco Deck Type: Wood Pre —Drilled No Drill Bit Size N/A Hole Depth N/A Sample No. Plan Identifier Initial Failure Load lb Field Test Area Perimeter Test Area Corner Test Area #1 same 719 X #2 484 X #3 720 X #4 587 X #5 712 X #6 566 X #7 773 X #8 613 X Page 413 Mean Failure Load: F = 646.75 lbf Sample Standard Deviation: Sf = 92.53 lbf Minimum Characteristic Resistance Force: F'= 569.39 lbf Notes: 7. Use the results herein to determine the required number of fasteners for insulation attachment or an acceptable anchor or base sheet fastener spacing, as outlined on FLORIDA BUILDING CODE TAS —117, Shall utilize the minimum characteristic force (F'), determined in compliance with section 8 of TAS 105. No margin of safety shall be applied to field withdrawal resistance test results determined in compliance with TAS 105 or TAS 195(A) 8. A safety factor of 2 to 1 shall be applied to laboratory testing` 9. The following pages shall be completed for each roof area and included with all Field Withdrawal Resistance Test Recording Sheets. Notes: ROOF AREA = A Insert Building and Parapet Heights. Para fron If no Parapet exists, insert ("N/A") GROUND LEVEL Building Information — Detail # 1 Page 5B Note: All Dimensions are Approximate — Drawing NTS ATRT Title Project: A. Tomassi Roof Testing, Inc. 5451 NW 24Tu Street, Suite # 3 Margate, Florida 33063 Project No. 1923-18 49' Fastener Withdrawal Test Area C Liberty Scrap Facility 417 Angle Road Fort Pierce, Florida Drawn Sheet No. D.G.Z 3 of3 TAS 105 - Test locations T = Tested Locations