Loading...
HomeMy WebLinkAboutMISC LETTERArchitectonic Inc St. Lucie County Planning & Development Services FILE COPY, Building & Code Regulation Division 2300 Virginia Ave. STENERs OR ATTACHMENTS RECEIVED Fort Pierce, FIL 34982 CONCEALED FA ARETHE RESPONSIBIL11TY OF T14E CONTRACTOR OR RECORD NOV 15 2018 November 14,2018 ST. Lucie County, Permitting RE: 3406 Dale Place, SLC SCANNED BY St. Lucie County To Whom It May Concern: Our office has performed design pressure calculations for the above referenced project and herby certify that the proposed garage doors are in compliance with the 2017 Florida Building Code, 160 mph wind zone, exposure "B", risk category 11. From Table 1609.3.1: Vult= 160mph V,,d= 124mph From TableI609.7(1): (1)9'-B"'xlO',160mph=+21.5/-24.2 (1) 8'x 8, 160 mph=+22.3/-25.2 From Table1609.7(2): 20' mean roof height, exposure B=1.0 Required Design Pressures: -25.2 Product: Overhead Door Corporation, 790 Series Rolling Sheet Door, FL# 12111.2 Product Pressures: +31.0 & -31.0 1-8 ST. LUCIE COUNTY S—L REVIEWED FOR COMP (—, z-ct PLANS'ANO PERMIT MUST BE KEPTM JOB SITE OR NO INSPECTION(S) WILLA MADE 806 Delaware Avenue Tel: 7724607751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 7724604244 FL Reg #AA26003348 1 of I