HomeMy WebLinkAboutMISC LETTERArchitectonic Inc
St. Lucie County
Planning & Development Services FILE COPY,
Building & Code Regulation Division
2300 Virginia Ave. STENERs OR ATTACHMENTS RECEIVED
Fort Pierce, FIL 34982 CONCEALED FA
ARETHE RESPONSIBIL11TY OF T14E
CONTRACTOR OR RECORD NOV 15 2018
November 14,2018 ST. Lucie County, Permitting
RE: 3406 Dale Place, SLC SCANNED
BY
St. Lucie County
To Whom It May Concern:
Our office has performed design pressure calculations for the above referenced project and herby certify
that the proposed garage doors are in compliance with the 2017 Florida Building Code, 160 mph wind
zone, exposure "B", risk category 11.
From Table 1609.3.1: Vult= 160mph
V,,d= 124mph
From TableI609.7(1): (1)9'-B"'xlO',160mph=+21.5/-24.2
(1) 8'x 8, 160 mph=+22.3/-25.2
From Table1609.7(2): 20' mean roof height, exposure B=1.0
Required Design Pressures: -25.2
Product: Overhead Door Corporation, 790 Series Rolling Sheet Door, FL# 12111.2
Product Pressures: +31.0 & -31.0
1-8
ST. LUCIE COUNTY S—L
REVIEWED FOR COMP
(—, z-ct
PLANS'ANO PERMIT MUST BE KEPTM JOB
SITE OR NO INSPECTION(S) WILLA MADE
806 Delaware Avenue Tel: 7724607751 www.architectonicinc.com
Fort Pierce, Florida 34950 Fax: 7724604244 FL Reg #AA26003348 1 of I