HomeMy WebLinkAboutDESIGN CALCULATIONSEasy GENERAL NOTES: :..oeats easyseals.com DESIGN CALCULATIONS FOR GRAND ARCADE WALL -MOUNTED SIGNS 6653 LIS-1 — Port St Lucie 1. Design is in accordance with the Florida Building Code 6th Edition (2017) for use within and outside the High Velocity Hurricane Zone (HVHZ). 2. Wind loads have been calculated per the requirements of ASCE 7-10 as shown herein. 3. These engineering calculations pertain only to the structural integrity of those systems, components, and/or other construction explicitly specified herein and/or in accompanying engineering drawings. The existing host structure (if any) is assumed to be in good condition, capable of supporting the loaded system, subject to building department approval. No warranty, either expressed or implied, is contained herein. 4. System components shall be as noted herein. All references to named components and installation shall conform to manufacturer's or industry specifications as summarized herein. 5. Where site conditions deviate from those noted herein, revisions maybe required or a separate site -specific engineering evaluation performed. 6. Aluminum components in contact with steel or embedded in concrete shall be protected as prescribed in the 2015 Aluminum Design Manual, Part 1. Steel components in contact with, but not encased in, concrete shall be coated, painted, or otherwise protected against corrosion. 7. Engineer sea[ affixed hereto validates structural design as shown only. Use of this specification by contractor, et. Al, indemnifies and saves harmless this engineer for all costs & damages including legal fees & apellate fees resulting from deviation from this design. SCANNED BY St. Lucie County Index: Pg 1 Cover Pg 2 Wind Loads Pg 3 Anchor Design 1200 N Federal Hwy� #200 Boca Raton, FL 33432 Easy Seals.com Page 1 I I CALCULATIONS, RWALL-MOUNTED SIGNS EasySeals eav�m ASCE 7-10 Design Wind Loads WALL -MOUNTED SIGNS Building Specs V=: 160mph :Baskwindspeed ExposureL Calculations a= 9.5 3-sec gust speed power low exponent Z� = 900' Nominal ht of atmos. boundary layer Gcpi = 0 Internal pressure coeff ASD Load Combo Coeff*.' 0.6 Kd 0.85 Directionalityfactor Kzt 1. 0 'Topographicfactor A io.�R-ft Tributary area 160 mph - Exp "C" WALL -MOUNTED SIGNS ASD WIND PRESSURES SIGN CENTER CORNER EIGHT (Zone 4) Zone 5) % U U 15 ft 31.2 psf 39.7 psf 0.85 47.3 -1.10 -1.40 20ft 33.2 psf 42.2 psf 0.90 50.2 -1.10 -1.40 25 ft 34.8 psf 44.2 psf 0.95 52.7 -1.10 -1.40 30ft 36.1 psf 46.0 psf 0.98 54.7 -1.10 -1.40 35ft 37.3 psf 47.5 psf 1.01 56.5 -1.10 -1.40 40 ft 38.4 psf 48.8 psf 1.04 58.1 -1.10 -1.40 45 ft 39.3 psf 50.1 Psf 1.07 59.6 -1.10 -1.40 50ft 40.2 psf 51.2 psf 1.09 60.9 -1.10 -1.40 55 ft 41.0 psf 52.2 psf 1.12 62.2 -1.10 -1.40 60 ft 41.8 psf 53.2 psf 1.14 63.3 -1.10 -1.40 70ft 35.3 psf 70.6 psf 1.17 65.4 -0.90 -1.80 soft 36.3 psf 72.6 psf 1.21 67.3 -0.90 -1.80 90 ft 37.2 psf 74.5 psf 1.24 69.0 -0.90 -1.80 100 ft 38.1 psf 76.1 psf 1.27 70.5 -0.90 -1.80 110 ft 38.8 psf 77.7 psf 1.29 71.9 -0.90 -1.80 120 ft 39.6 psf 79.1 psf 1.32 73.3 -0.90 -1.80 130 ft 40.2 psf 80.5 psf 1.34 74.5 -0.90 -1.80 140 ft 40.9 psf 81.7 psf 1.36 75.7 -0.90 -1.80 150 ft 41.5 psf 82.9 psf 1.38 76.8 -0.90 -1.80 175 ft 42.9 psf 85.7 psf 1.42 79.3 -0.90 -1.80 200 ft 44.1 psf 88.1 Psf 1.46 81.6 -0.90 -1.80 250 ft 46.2 vsf 92.3 Psf 1.53 85.5 -0.90 -1.80 Page 2 0,EasySeals Wall Sign Anchor Design Structure Dimensions & Loading Design wind pressure: Sign type: Sign size: CALCULATIONS" ,411WALL-MOUNTED SIGNS P - --,Psf Raceway h=� 24.0 �inches (height) Wall material: Wood �CDX or equiv, thickness to match Min Embed Anchor type/size: Ref: Powers Strap -Toggle, catalog Min Embedment: 0.5" Min edge dist: 2" Anchor tensile capacity: Tcap 169.4 lb (per anchor) Check Anchors for Pullout Total Reaction: Rt = 92 lb/ft ... = P*h (along raceway) Anchor spacing req'd S = 44.2 in D.C. ... = (2*cap)/Rt Pairs of anchors at 44 inches on center (max) 3.7 feet on center OK, typical anchor option shown. Ref anchor schedule for other anchor options. Page 3