Loading...
HomeMy WebLinkAboutEVALUATION REPORTm EVALUATION REPORT OF METAL SALES MANUFACTURING CORPORATION '26 GA. PBR-PANEL' FLORIDA BUILDING CODE 6TH EDITION (2017) FLORIDA PRODUCT APPROVAL FL 10999.7-R3 STRUCTURAL COMPONENTS ROOFDECK SCANNED BY St. Lucie County Prepared For: Metal Sales Manufacturing Corporation 545 South 3rd Street, Suite 200 Louisville, KY 40202 Telephone: (502) 8554300 Fax: (502) 855-4200 Prepared By: Bala Sockalingam, PhJ), P.E. Florida Professional Engineer #62240 1216 N Lansing Ave., Suite C Tulsa, OK 74106 Telephone: (918) 492-5992 FAX: (866) 366-1543 This report consists of Evaluation Report (3 Pages including cover) Installation Details (1 Page) OCKALI %% Load Span Table (1 Pa % ge) % 62240 cc OF Z Report No. C2180-7 Date: 8.25.2017 IONP, 1% Fl, 10999.7-R3 C2180-7 8.25.2017 Page 2 of 3 Manufacturer: Metal Sales Manufacturing Corporation Product Name: Panel Description: 36" wide coverage with (4) 1-1/4" high ribs Materials: Min. 26 ga., 80 ksi steel or min. 24 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Support Description: Min. 16 ga., 50 ksi steel section. (Must be designed by others) Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2. Requires applied lap sealant for roof slopes less than 3:12. Design Uplift Pressure: 41.9 psf @ fastener spacing of 60 o.c. (3 or more spans) (Factor of Safety = 2) 154.4 psf @ fastener spacing of 24 o.c. (3 or more spans) 'Panel Attachment: At panel ends #12-14 x 1-1/4" long SDS with washer @ 7%5%7" o.c. across panel width At intermediate #12-14 x 1-1/4" long SDS with washer @ 12" o.c. across panel width Sidelap Attachment: 1/4"-14 x 7/8" long SDS with washer @ 12" o.c. Test Standards: Roof assembly tested in accordance with ASTM E1592-01 'Test Method for Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference' and FM 4470 Section 5.5 'Resistance to Foot Traffic'. Test Equivalency: The test procedure in ASTM E1592-01 comply with test procedure prescribed in ASTM E1592-05(2012). The test procedure in FM 4470 (1992) comply with test procedure prescribed in FM 4470 (2012). Code Compliance: The product described herein has demonstrated compliance with FBC 2017 Section 1507.4. Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum support spacing listed herein shall not be exceeded. The design pressure for reduced clip spacing may be computed using rational analysis prepared by a Florida Professional Engineer or based on Metal Sales load span table. This evaluation report is not applicable in ffigh Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to Fl, 10999.7-R3 C2180-7 8.25.2017 Page 3 of 3 FBC 2017 Section 1505 and current approved roofing materials directory or ASTM E1081UL790 report from an accredited laboratory for fire ratings of this product. Supporting Documents: ASTM E1592 Test Reports Farabaugh Engineering and Testing Inc. Project No. TI 54-06, Reporting Date 5/15/06 FM 4470 Test Report ENCON Technology Inc. C1587-1, Reporting Date 5/17/08 Ricky Cochran, Apostolopolous & Paulick Construcbon MIN 16 (DBIM SEE DErAJL 1 PANEL. F�ENDR PER � � T� SFACED = 12' O.C. XROSS IRIBS IN Ml[) AND TNO F� AT � M AT PANS- ENUS (7--5�-7- I/e-14 X '7,f.SUS INITH INASHER SP� ff C. TYPICAL PANEL INSTALLAMON X-SECTIQ � wa.o 0 Sc! -2 9 912-14 X 1 1/4' KK CORROSX)N TED F� Ilml GENEIRAL P0� WASHM SEE ESSURE TASUE FOR L STRUMRX ROOF P� � BEEN DE&ICHED IN ACCO�E WM ME FLORIDA BLIMING CODE (FBC)- 0. Z PANO-S � BE MIRC 26 G& (I - 0.017'). EFREC� �NG WDM OF P� - W. MIN 26 Gk PMEL 3. ME ROOF P� SH� ME INST� O� STRUMIZE � SPECHEO ON NESE �NIIhlcs. 4. FEQUI� DESIGN VRND LOMIS Sl� BE DEHER%IiNED M E� �CT. MIS PANEL � MY NOT BE ll�� WEN ME GREAIFER! MAN ME �� WND L� �IMED ON MIS D�WNG. 5. F� MUW BE IN ACCORUANCE iNITH MIS D�WIG & ME FSIRIDA Gk. SO I:Sl S7100 =114G CODE. IF A DIFFERENCE OCCURS B� ME MINIMUM ff OWENS) EQUZ� OF MIS D�G & ME WDL ME CODE S� �01_ 6, MUST BE DESIGMEM TO INIMSTW WND LOADS AS MMIZED FG!3 � �WN MID � ME � OF OMEN& DETAIL 1 METAL SALES MANUFACTURING CORPORATION PBR-Panel Uplfft Loads Win 26 ga.) Description Fastener Spacing along panel length (in) Allowable Uplift Load (psf) Coverage width: 36" Panel Fasteners #12-14 x 125" long hex head screws with sealed washer Panel fasteners spaced at 12" o.c. across panel width Sidelap fasteners spaced at 12" o.c. 24 154A 27 137.2 30 123.5 33 112.3 36 102.9 39 95.0 42 85.5 45 74.5 48 65.5 51 58.0 54 51.7 57 46.4 60 41.9 Notes: 1. The bold numbers indicate design loads calculated from test data with safety factor of 2. 2. Panels must be installed as per Evaluation Report FL 10999.7 and Metal Sales current installation procedure. 3. Three or more spans condition. 1216 N Lansing Ave., Suite C Tulsa, Ok 74106 9184925992 OCKALltV*"*. %% S ........ %%%% F-Ns"- No 62240 LU S -rpJE Or- Z X� 0 Fk N -2�. ?-o I Bala Sockalingam, Ph.D., P.E. FL 62240