Loading...
HomeMy WebLinkAboutMISC LETTERGary Powell Architecture and planning 16 South River Road Sewalls Point, Florida. 34996 Ph. 772-223-1755 November 19, 2018 FILE CO" To Building & Zoning Department Martin County, Florida Ref. Roof fastening letter for: Palm Property Management,inc. 5750 Orange Ave. Ft. pierm Florida 34997 CONCEALED FAS7ENERS OR A7TACHMENTS ARE THE RESPONSIBILITY OF THE COWRACTOR OR RECORD SO 0% To whom it may concern: Below is the design wind pressures analysis for roof zones 1, 2, & 3 for Metal sales Manufacturing Corp. Fl. 10999.7 R3 Structural roof deck components for the above referenced project. Fasteners: Per mfgr. specs. material span 60" Zone 1 (22 ga.) (Field) -43.0 Product tested -71.0 psf. Ok Zone 2 (22 ga.) (perimeter) -59.9 psf. (Product tested -71.0 psf. Ok Zone 3 (22 ga.) (Comers) -69.0 psf. (product tested) -71.0 psf. ok If there are any further questions please feel free to call my office at 772-223-1755 Thank you: / W Gary Powell Architect reg. # 12125 ST. LUCIE COUI REVIEWED FOR FLANb AND PERMIT MUST BE KEPT pf JOB SITE OR NO INSPECTION(S) WILL EtE MADE THESE PLANS AND ALL PROPOSED WORK ARE SUBJECTTO ANY CORRECTIONS TH� REQUIRED BY FIELD INSPECTORS AT MAY BE NECESSARY IN ORDER TO �?A LY C ' 0 WITH ALL APPLICABL-c cC)DES.