HomeMy WebLinkAboutMISC LETTERM.A. CORSON & ASSOCIATES. Inc. ARCHITECTURE * STRUCTURAL DESIGN 1121 S.E. Ocean Blvd., Stuart, Fl. 34996 (772) 223-8227 * Lic. #AR91665 Date: November 28, 2018 FILE C PY fc IQ fi�l 12—Dd31 To: St. Lucie County - Building & Code Regulation Division SCA VNE1) 8 Re: 9940 S. Ocean obert rDrive Unit 901 St ��Cie COunty Jensen Beach, Fl. , 34957 It is acceptable to replace existing sliding glass door, single hung, & double hung window openings for the address listed above with PGT Systems units as follows: 1) S.G.D-"5570/2770 " impact/ vinyl sliding glass door has a Florida number NOA- #17-0420.06. It has a+80 / -80 design pressure and has a large missile "D" approval and HVHZ. 2) D.H. - The "DH 5560" pvc double hung window has a Florida number NOA-#17- 0630.10. The nominal wind speed is 132 mph and the ultimate wind speed is 170 mph. It has a +80 /-80 design pressure and has a large missile "D" approval and HVHZ . 3) S.H. -The "SH 5500" pvc single hung window has a Florida number NOA-#17- 0630.05. The nominal wind speed is 132 mph and the ultimate wind speed is 170 mph. It has a +65 /-70 design pressure and has a large missile "D" approval and HVHZ . The actual building design pressures of address listed above in Zone 4 is +57.3 / -62.3 The building has a type 11 classification and exposure category "D" for the 6th Edition of the FBC (2017). Worst case scenario has been calculated . Thank you for your time and consideration. If you have any questions please call. Respectfully, Mark A. Corson A.I.A., NCARB President