HomeMy WebLinkAboutBUILDING SCHEMATICBUlMM'S PEAK ROOF HEIGHT to DESIGN WIND PRESSURE FOR COMPONENTS 6t CLADDING (P S F,) FOR ASCE 7 10 PEAK ROOF HEIGHT LS5 THAN OR EDUAL TO 60 FEET BASIC WIND SPEED = 170 mph RISK CATEGORY ll BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, WHOLESALE) PEAK ROOF L" LESS THAN 7'-9' I' GREATER OR EQUAL THAN 7'-9' AND LESS THAN 12'-3" C" GREATER OR EQUAL THAN 11'-3" HEIGHT POSITIVE NEGATIVE POSITIVE NEGATIVE POSITIVE NEGATIVE (h) ULTIMATE A.S.D. ULTIMATE A.S.D. ULT/MATE ASD. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. 0' - 15, 76.4 45.8 102.4 61.4 73.0 43.8 95.5 57.3 68.5 41.1 86.4 51.8 > 15'-20' 80.4 48.2 f076 64.6 76.8 46.1 100.4 60.2 72.0 43.2 90.8 54.5 > 20'-25' 83.6 50.2 111.9 67.1 79.8 479 104.4 62.6 74.8 44.9 94.4 56.6 > 25'-30' 86.2 51.7 115.5 69.3 82.4 49.4 107.7 64.6 773 46.4. 97.4 58.4 > 30'-40' 90.7 54.4 121.4 72.8 86.6 52.0 113.3 68.0 81.2 48.7 102.4 61.4 > 40'-50' 94.3 56.6 126.2 75.7 90.0 54.0 117.7 70.6 84.4 50.6 f06.5 63.9 > 50'-60' 973 58.4 130.3 78.2 92.9 55.7 121.5 72.9 87.2 52.3 109.9 65.9 BUILDING'S PEAK ROOF HEIGHT vs DESIGN WIND PRESSURE FOR COMPONENTS & CLADDING (P.S F) FOR ASCE 7-10 - PEAK ROOF HEIGHT GREATER THAN 60 FEET ar BASIC WIND SPEED = 170 mph RISK CATEGORY I/ BUILDINGS FILERESIDENTIAL, APARTMENT BUILDINGS &COMMERCIAL BUILDINGS (RETAIL, WHOLESALE) �®PY FILE COPY .(zr��� IBIZ-aD-5 RECEIVED DEC 0 4 701E Pe 5 ' Luce COuy�en[ m PEAK ROOF L" LESS THAN 12-3' L" GREATER OR EQUAL THAN 12'-3' HEIGHT POSITIVE NEG47IVE POSITIVE NEGATIVE (h) ULTIMATE A.S.D. ULTIMATE A.SD. ULTIMATE A.S.D. ULTIM47£ A.SD. > 60' - 70' 91.5 54.9 1677 100.E 84.3 50.6 148.4 89.0 > 70' - 80' 93.6 56.2 171.6 103.0 86.2 51.7 151.9 91.1 > 80' - 90' 95.6 57.4 175.2 105.1 88.0 52.8 155.0 93.0 > 90' - 100' 973 58.4 178.4 1074 1 89.7 53.8 157.9 94.7 > 100' - 120' 100.5 60.3 184.2 110.5 92.5 55.5 163.0 978 > 120' - 140' 103.2 61.9 1 189.2 113.5 95.1 1 57. 1 167.4 100.4 > 140' - 160' 105.6 63.4 & 193.6 116.2 _ 973 58.4 171.3 102.8 - 80` 107.8 64Y7 197.6 ZIILB!6A 99.3 59.6 174.9 104.9 * 1 Z---2oo' 109.8 65.9 2U1.3 120.8 101.1 60.7 178.1 106.9 * 200' - 250' 114.1 68.5 209.2 125.5 105.2 63.1 185.1 111.1 > 250' - 300' 117.8 70.1 216.0 129.6 108.5 65.1 191.1 114.7 > 300- .3!10-1 121.0 72.6 221.9 133.1 111.5 66.9 196.3 117.8 > 350' - 400'1 123.9 74.3 227.1 136.3 114.1 68.5 200.9 120.5 > 400' - 450'1 126.4 75.8 231.8 139.1 116.5 69.9 205.1 123.1 > 450' - 500' 128.8 77.3 236.1 141.7 118.6 71.2 208.9 125.3 NOTES: I.) THIS CEROFIED SIGNED AND SEALED WIND LOAD CHART, PREPARED BY THIS ENGINEER, BASED ON ASCE 7-10, FOR A BASIC WIND SPEED OF 170 MPH, AND APPLICABLE RISK CATEGORY BUILDING & EXPOSURES, 15 COMPLETELY GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SHE SPECIFIC PROJECT. 2.) THIS WIND LOAD CHART MUST BE SIGNED, SEALED AND DATED BY THIS ENGINEER IF USED TO OBTAIN A ONE 77ME BUILDING PERMIT. 3) CONTRACTOR OR PERM? HOLDER TO BE RESPONSIBLE FOR THE SELECTION OF DESIGN WIND PRESSURE B45ED ON THIS GENERIC WIND LOAD CHART. WIND PRESSURES ARE ULTIMATE AND ASO. PRESSURES. 4.) THIS WIND LOAD CHART SHALL BE CONSIDERED INVALID IF ALTERED BY ANY MEANS. 5.) DESIGN WIND LOAD SELECTED BY THE CONTRACTOR OR PERMIT HOLDER FROM THIS WIND LOAD CHART SHALL BE INDICATED ON A SEPARATE DOCUMENT PREPARED BY THE CONTRACTOR OR PERMIT HOLDER (e.g., SPREADSHEET, OPENING SCHEDULE/TAKE OFF SHEET, ETC.). OQ'.- Ti of ?yam ,-q,$EN8j %%0% c u° 17®.4416I e E STATE ®� s s '%&` a10�i1®�:� ee 0 * INDICATED DESIGN WIND PRESSURES CORRESPOND TO THE MAXIMUM END ZONE AND INTERIOR ZONE CONDI7IONS AND FOR ALL ROOF SLOPES. * L = STORM PANEL LENGTH, ACCORDION SHUTTER BLADE LENGTH OR BAHAMA SHUTTER HEIGHT. PRODUCTS WHICH BEAR A M/AMI-DARE COUNTY OR A STATE OF FLORIDA APPROVAL FIlwall 1� gt-_-ql =2=�Mftl PE p4iko(� Y�EoGO 2017 (6th EDITION) FLORIDA BUILDING CODE - BROWARD, PALM BEACH, MARTIN, ST. LUCIE & INDIAN RIVER COUN77ES ASCE 7-10 / WIND PRESSURE CHART L.C. STORM PANEL$ ACCORDION & B4H4MA SHUTIERS "" DRAWN BY RISK 04T. 11 SLOGS 08109117 8 L E C ®o ae c. WIND PRESSURE CHART DATE T TESTING R ENGINEERING COMPAftlY BASIC WIND SPEED = 170 mph W. Jafh 57e. Jos. vnNlNu 615G0/S a W166 EXPOSURE D, Kd = 0.85 % 7- 194 1.n. (JOJ871-ISJo . F.r : (JGa)a71-IJJ1 DRAWING No EB-0006719 1¢ L t ✓ �' an .[v. x, elJmmnar .,rz WALTER A TILUT Jr. P.E. 1 wo Is-ree /i r FLORIDA Uc. i 44167 . 1 11 SHEET i OF I