Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEPlanning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 46 Certification for Design Load Compliance Project Name: SOUTHERN OAKS ESTATE POA PED. BRIDGE Project Address: 2308 GRAND OAK AVE Permit#:1812-0058 Occupancy Type: Construction Type: DEC 17 2018 Lucie County, PermItting INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition SCANNED o Any accessory structure requiring a building permit BY o Any non-residential structure. 1c3t. Lucie County * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida BUILDING Code Fifth Edition with 20 17 Supplements using ASCE 7-10 2. Structure Designed as (check one): _Enclosed _Partially Enclosed X Open 3. Risk Category: _I X II _III IV Exposure Category: _B _C X D 4. Design Wind Velocity 165 mph _ASD X LRFD End Zone Width: 1 ft S. Mean Roof Height 5'+/-DECK HEIGHT ft Roof Pitch: :12 Parapet: ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: Zone 2: Zone 3: Zone 4: +60.6/-64.1 Zone 5:+70.1/-74.5 Garage: 7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Live: Balcony: PSF Dock: 40 PSF Deck: ' PSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? _Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specaf\ iejIIIII///, DANIEL PAUL RETHERFORD 72451 �1gJ� ®� -------..00 Print Name Cert # & Co. Cert Auth. ic_Ie it 4i g; Date an S�a) ; 1402 HARTMAN ROAD, FT PIERCE, FL 34947 e ', �9 f ^C!` Company Name & Address a�.. 1