BUILDING SCHEMATIC
L3/ADING'S PEAK ROOF MONT vs DESIGN WIND PRESSURE FOR COMPONENTS CL4DD/NG (P S F.) FOR ASCE 7-10 - PEAK ROOF HEIGHT LESS THAN OR E/ AL TO 60 FEET a BASIC WIND SPEED = 170 mph RISK CATEGORY 1/ BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, WHOLESALE) PEAK ROOF L" LESS THAN 7'-9' I' GREATER OR EQUAL THAN 7'-9' AND LESS THAN 12'-3' I- GREATER OR EQUAL THAN 12'-3' HEIGHT POSITIVE NEGATIVE POSITIVE NEGATIVE POSITIVE NEGATNE (h) ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. 76.4 45 jj 102.4 4gLli,4 73.0 43.8 95.5 573 68.5 41.1 86.4 51.8 > 5 =30 80.4 48.2 107.6 64.6 76.8 46.1 100.4 60.2 72.0 43.2 90.8 54.5 > 20'-25' 83.6 50.2 111.9 67.1 79.8 47.9 104.4 62.6 74.8 44.9 94.4 56.6 > Z5-ju I 86.2 51.7 115.5 69.3 82.4 49.4 107.7 64.6 773 46.4. 974 58.4 > 30-40' 90.7 54.4 121.4 72.8 86.6 52.0 113.3 68.0 81.2 48.7 102.4 > aD'-50' 94.3 56.6 126.2 75.7 90.0 54.0 117.7 70.6 84.4 50.6 106.5 L65. > 50'-so' 973 58.4 130.3 78.2 92.9 55.7 121.5 72.9 87.2 52.3 109.9 INDICATED DESIGN WIND PRESSURES CORRESPOND TO THE MAXIMUM END ZONE AND INTERIOR ZONE CONDITIONS AND FOR ALL ROOF SLOPES. Or* L = STORM PANSY LENGTH ACCORDION SHUTTER BLADE LENGTH OR BAHAMA SHUTTER HEIGHT. PRODUCTS WHICH BEAR A MLAMI-DARE COUNTY OR A STATE OF FLORIDA APPROVAL BUILDING'S PEAK ROOF HEIGHT vs DESIGN WIND PRESSURE FOR COMPONENTS & CLADDING (P.S.F.) FOR ASCE 7-10 - PEAK ROOF HEIGHT GREATER THAN 60 FEETati BASIC WIND SPEED = 170 mph RISK CATEGORY II BUILDINGS FILECQI� RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, WHOLESALE) V� SCANNED BY St. Lucie County PEAK ROOF I- LESS THAN 12-3' 1- GREATER OR EQUAL THAN 12'-3' HEIGHT POSITIVE NEGATIVE POSITIVE NEGATIVE (h) ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. > 60' - 70' 91.5 54.9 16Z7 100.6 84.3 50.6 148.4 89.0 > 70' - 80' 93.6 56.2 171.6 103.0 86.2 51.7 151.9 91.1 > 80' - 90' 95.6 5Z4 175.2 105.1 88.0 52.8 155.0 93.0 > 90' - 100' 973 58.4 178.4 IOTA 89.7 53.8 15Z9 94.7 > 100' - 120' 100.5 60.3 184.2 110.5 92.5 55.5 163.0 978 > 120' - 140' 103.2 61.9 1 189.2 1135 95.1 571 1674 100.4 > 140' - 160' 105.6 63.4 193.6 116.2 973 58.4 171.3 102.8 > 160' - 180' )078 64.7 197.6 118.6 99.3 59.6 174.9 104.9 > 180' - 200' 109.8 65.9 201.3 120.8 101.1 60.7 178.1 105.9 > 200' - 250' 114.1 68.5 209.2 125.5 105.2 63.1 185.1 111.1 > 250' - 300' 1 178 70.1 216.0 129.6 108.5 65.1 191.1 114.7 > 300' - 35a' 121.0 72.6 221.9 133.1 111.5 66.9 196.3 11ZEI > 350' - 400' 1239 74.3 227.1 136.3 114.1 68.5 200.9 120.5 > 400' - 450' 126.4 75.B 231.8 139.1 116.5 69.9 205.1 123.1 > 450' - 500' 128.8 7 .3 236.1 141.7 1 118.E 1 71.2 208.9 125.3 NOTES: 1.) THIS CER77RED SIGNED AND SEALED WIND LOAD CHART, PREPARED BY THIS ENGINEER, BASED ON ASCE 7-10, FOR A BASIC WIND SPEED OF 170 MPH, AND APPLICABLE RISK CATEGORY BUILDING & EXPOSURES, IS COMPLETELY GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SIM SP£CIRC PROJECT. 2.) THIS WIND LOAD CHART MUST BE SIGNED, SEALED AND DATED BY THIS ENGINEER IF USED 70 OBTAIN A ONE TIME BUILDING PERMIT. S) CONTRACTOR OR PERMIT HOLDER TO BE RESPONSIBLE FOR THE SELECTION OF DESIGN WIND PRESSURE WED ON THIS GENERIC WIND LOAD CHART. WIND PRESSURES ARE ULTIMATE AND ASO. PRESSURES. 4.) THIS WIND LOAD CHART SHALL BE CONSIDERED INVALID IF ALTERED BY ANY MEANS. 5.) DESIGN WIND LOAD SELECTED BY THE CONTRACTOR OR PERMIT HOLDER FROM THIS WIND LOAD CHART SHALL BE MD/CATED ON A SEPARATE DOCUMENT PREPARED BY THE CONTRACTOR OR PERMIT HOLDER (e.g., SPREADSHEET, OPENING SCHEDULE/TAKE OFF SHEET. ETC.). FILE CQPY Y ° P!o•JA967 QRopoG�t lFt 1E� 2017 (6th ED/IION) FLORIDA BUILDING CODE - BROWARD, PALM BEACH, MARTIN, Si. LUCI£ & IND14N RIVER COUNTIES ASCE 7-10 / WIND PRESSURE CHART L.C. STORM PANELS, ACCORDION & BAHAMA SHURERS '"*'" DRAWN BY RISK C T.. 11 BLDGS 08/09/17 WIND PRESSURE CHART DATE IT TESTING & ENGINEERING COMPANY BASIC WIND SPEED = 770 mph 17_ 194 N.W. Jbfh SY. 5'f•. MIL VIAGIM GWDTNS A Jl166 EXPOSURE D, Kd = 0.65 PA•n° : (Jp8)87 flW .Pox : (Jp5f971-i6J1 DRAWING N. EB-0006719 mm WALTER A DLL T Jr.P.E. : aD iJ-1ee /1 a FLORIDA Dc. If 44167 : °� < SHEET i OF i ff