Loading...
HomeMy WebLinkAboutMISC LETTERr Architectonic Inc St. Lucie County Building Department Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Ft. Pierce, FL 34982 December 7, 2018 SCANNED BY St. Lucie County RE: Nettle Island Guard House, 9807 South Ocean Drive Fort Pierce, FL To Whom It May Concern: Our office has performed design pressure calculations for the above referenced project and herby certify that the proposed sliding glass door in compliance with the 2017 Florida Building Code, 165 mph wind zone, exposure "C", risk category II. Exposure "C" Multiplier 1.21 Wind Zone 4 31.95 x 1.21= 38.65 WindZoneS 39.4x1.21=47.6 Required Design Pressures: +/-47.6 THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. Product: PGT Industries, SGD 770, NOA# 17-0420.12 Product Pressures: +90.0 & 90.0 ALL MANUFACTURES LABLFS SHOWING U FACTORS AND SHGC COMPLIANCE WITH FBC ENERGY CODE MUST REMAIN ON ALL DOORS AND WINDOWS UNTIL INSPECTIONS ARE APPROVED CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD. 18/z - 02&3 ST. LUCIE COUNTY BUILWNG DIVIS ON REVIEWED FOR COMPL A CE �qy/J REVIEWED BY DATE PLANS AND PERMIT MVIT BE KEPT ON JOB SITE OR NO INSPECTI (S) WILL BE MADE 806 Delaware Avenue Tel: 772 460 7751 www.arc0itedlgr9giSCleom m a ' Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1