HomeMy WebLinkAboutPRODUCT APPROVALFlorida Building Code Online
Page 1 of 2
BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats & Facts I Publications I FBC Staff I BCIS Site Map I Unks I Search I
b
a
�. 01ral Product Approval
1 USER: Public User
Ertrv�azm
Product Approval Menu > Product or Application gooll��}ttlon Search > Application List > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
FL17080-R2
Revision
2017
Approved
L
is
0o
Folding Shutter Corporation ���
7089 Hemstreet Place
West Palm Beach, FL 33413
(561) 683-4811 Ext 7675
edh@foldingshutters.com
Ed Heritage
edh@foldingshutters.com
Ed Heritage
7089 Hemstreet Place
West Palm Beach, FL 33413
(561) 683-4811 Ext 7675
edh@foldingshutters.com
Ed Heritage
7089 Hemstreet Place
West Palm Beach, FL 33413
(561)209-7675
edh@foldingshutters.com
Impact Protective Systems
Operable
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
El Evaluation Report - Hardcopy Received
Walter A. Tillit Jr., P.E.
PE-44167
PFS Corporation
12/31/2018
Troy Bishop, P.E.
EU Validation Checklist - Hardcopy Received
FL17080 R2 COI FOLDING SHUTTER CORP. TITAN II FOLDING
IMPACT PROT.SYSTEM CERTIFICATION OF INDEPENDENCE 17-
0725.0 O.PDF
Referenced Standard and Year (of Standard) Standard
Year
http://www.floridabuilding.orglprlpr_app_dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6r1Z%2ficUcN... 12/13/2017
Florida Building Code Online
TAS 201, 202, 203
1994
Page 2 of
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 08/17/2017
Date Validated 08/18/2017
Date Pending FBC Approval 08/23/2017
Date Approved 10/10/2017
Model, Number, or Name
scrtpbon
17080.1
Titan II Folding Impact Protective
Extruded aluminum blades folded together through knuckles
System/HVHZ & NHVHZ (Drawing
and retained by tracks to provide Hurricane Protection
#17-082)
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
FL17080 R2 II FOLDING SHUTTER CORP. DRWG 17-
082.PDF
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Verified By: Walter A. Tillit Jr., P.E. PE-44167
Design Pressure: +160/-160
Created by Independent Third Party: Yes
Other: Max span is 12'-0" for +46, -46 p.s.f. A.S.D. design
Evaluation Reports
load and 5'-2" for +160, -160 p.s.f. A.S.D. design Ioad.See
FL17080 R2 AE FOLDING SHUTTER CORP. TITAN II
FOLDING PROT SYSTEM Product Evaluation Report 17-
sheet 13 for additional spans and loads.
0725.01 DRWG 17 O.PDF
Created by Independent Third Party: Yes
edk e>ib.
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 85OA87-1824
The State of Florida Is an AA(EEO employer. Coovrlaht 2007-2013 State of Florida.:: Pdvacv Statement :: Accessibillb, Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send
electronic mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if
they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under
Chapter 455, F.S., please click here_.
Product Approval Accepts:
-• rETRI
SCCUI'1 ty
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rl Z%2fIcUcN... 12/13/2017
Florida Building Code Online Page 1 of
. BCIS Home i Log In 1 User Registration I Hot Topics I Submit Surcharge I Stats & Faris
Florida
�q, '�'•, Product Approval
a
4 .y USER: Public User
r,. 1
SYyy'BJ�pli:0
I Protluct Aooroval Menu > Product or Aoolimtlon Search > AoollcaHon List > AoolicaBon Dedii
FL #
FL5790-1112
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived
Cl
Product Manufacturer
American Shutter Systems Association, Inc.
Address/Phone/Email
4268 Westroads Drive
West Palm Beach, FL 33407
(561) 209-8263
bfeeley@easternmetal.com
Authorized Signature Bill Feeley
Irodriguez@easternmetal.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Shutters
Subcategory Roll -up
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Trevor Johnson
the Evaluation Report
Florida License PE-65624
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2018
Validated By John Henry Kampmann Jr.
F/J Validation Checklist - Hardcopy Received
Certificate of Independence FL5790 R12 COI CertificationOfIndeoendenceSS odf
Referenced Standard and Year (of Standard) Standard Year
ASTM E-1886 2002
ASTM E-1886 2005
ASTM E-1996 2005
ASTM E-1996 2002
ASTM E-330 2002
TAS 201 202 203 1994
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtDmAG7pmns8k0719PNvxfDMi2... 1 /2/2018
Florida Building Code Online
Page 2 of
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Method 1 Option D
10/09/2017
10/12/2017
10/17/2017
12/12/2017
pgmffaof;P?otluets'' „,�-.,`, 4"'a-s... a. -G is v: '^'c r£v. .s yt.d sr �q.e s-k':�• ry S'y.: yr `Yi'�i is
escn tton t
5790.1
58mm Bertha End Retention / Non-
Roll Shutter System (includes View Port Option)
Retention Roll Shutter System
(Non-HVHZ)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL5790 R12 II InstallationInstructionsSS.Ddf
Approved for use outside HVHZ: Yes
Verified By: Trevor Johnson, P.E. PE-65624
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: This product shall not be installed within High
FL5790 R12 AE EvaluationReoortSS.Ddf
Velocity Hurricane Zone. For design loads and spans refer to
Created by Independent Third Party: Yes
engineered drawings (Installation instructions).
Contact U= :: J601 BlairStore Road. Tallahassee EL 32399Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Comrioht 2007-2013 State of Florida, :: Prlvacv Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send
electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. "Pursuant to
Section 45S.275(1), Florida Statutes, effective October I, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If
they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public To determine if you are a licensee under
Chapter 455, F.S., please dick here .
Product Approval Accepts:
M9® ® ER
Credit Card
Safe
httD://www.floridabuildinR.ore/Dr/Dr anD dtl.asvx7param=wGEVXOwtDcitDnIAG7nnms8kO719PNvxfDMi2... 1/2/201E