NOTICE OF ACCEPTANCE (NOA) wew.miamidade.eov/economy
TAMKO Building Products, Inc.
220 West 411 Street
Joplin, MO 64801
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this
product or material tested for quality assurance purposes. if this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: TAMKO Roof Shingles
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. if any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No.15-0709.19 and consists of pages I through 6.
The submitted documentation was reviewed by Gaspar J Rodriguez.
4) -A-
NOA No.: 15-1215.10
Expiration Date: 12/01/20
Approval Date: 05/26/16
Page 1 of 6
� l �
ROOFING ASSEMBLY APPROVAL
Cateeorr
Sub-Cateeorv•
Materials:
Deck Type:
SCOPE
Roofing
Asphalt Shingles
Laminate
Wood
This approves TAMKO's Heritage, Heritage Woodgate and Heritage Premium asphalt shingles, manufactured by
TAMKO Building Products, Inc., as described in this Notice of Acceptance and designed to comply with the Florida
Building Code High Velocity Hurricane Zones.
PRODUCT DESCRIPTION
Product
Dimensions Test
Product Description
Specifications
Heritage
13 %" x 39 ;/s" TAS 110
Dimensional asphalt shingle.
Manufacturing Location # 1, 2, 3
Heritage Woodgate
13 %d' x 39 3/81, TAS 110
Dimensional asphalt shingle.
Manufacturing Location # 1,3
Heritage Premium
13 '/4" x 39 3/8,, TAS 110
Dimensional asphalt shingle.
Manufacturing Location # 1, 2, 3
MANUFACTURING LOCATIONS
1. Dallas, TX
2. Tuscaloosa, AL
3. Frederick, MD
EVIDENCE SUBMITTED
Test Aeency
Test Identifier
Test Name/Reyort
Date
Underwriters Laboratories, Inc.
TAS 107 & UL 790
04CA44252
02/25/05
ASTM D3462
02NK33813
09/23/02
ASTM D 3462 & TAS 107
R2919 Letter
03/10/11
ASTMD3462
4789110543
08/26/14
TAS 107
02/19/15
ASTM E 108
08/26/14
ASTM D3161, Class F
4787043752
10/20/15
PRI Asphalt Technologies, Inc.
TAS 100
TAP-129-02-01
05/26/05
TAS 100
TAP-130-02-01
05/26/05
TAS 100
TAP-131-02-01
05/26/05
PRI Construction Materials Technologies LLC TAS 100
TAP-303-02-01
12/12/14
TAS 100
TAP-307-02-01
02/10/15
TAS 100
TAP-317-02-01
09/02/15
NOA No.: 15-1215.10
Expiration Date: 12/01/20
Approval Date: 05/26/16
Page 2 of 6
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shingles shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61 G20-3 of the Florida Administrative Code.
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115.
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail `A', attached.
5. Nailing shall be in compliance with Details'B', attached.
LABELING
Shingles shall be permanently labeled with the manufacturer's name and/or logo, city and state of
manufacturing facility, and the following statement: "Miami -Dade County Product Control Approved" or with
the Miami -Dade County Product Control Seal as seen below:
BUILDING PERMIT REQUIREMENTS
As required by the Building Official or the applicable Building Code in order to properly evaluate the
installation of this system. This Notice of Acceptance on its own cannot be used to obtain a building permit.
NOA No.: 15-1215.10
Expiration Date: 12/01/20
Approval Date: 05/26/16
Page 3 of 6
19
DETAIL A
HERITAGE, HERITAGE WOODGATE, AND HERITAGE PREMIUM
All dimensions are in inches.
5TH COURSE
4TH COURSE
103.
3RD COURSE
trrs
2ND COURSE
23
1ST COURSE
29
Full
DETAIL B
HERITAGE SHINGLE
FIG. 1 FASTENING PATTERN
All dimensions are in inches
1" 7'/" 7'W 7 3/a" 71/s" 7'/:" 1"
el�l� �I =11 11,IH
13
------------------ ------------- ........ - -------------- ------------
__________________________ --__-_-__--_------____-_--_-_-f--_-_-________R____
F11
E
1/4"
-50
xpoSUre
NOA No.: 15-1215.10
Expiration Date: 12/01/20
Approval Date: 05/26/16
Page 4 of 6
DETAIL B (CONTINUED)
HERITAGE SHINGLE
FIG 2 ALTERNATE FASTENING PATTERN
Gt%�tmanBORd'
HERITAGE SHINGLE
(TUSCALOOSA, AL)
F1G. 3 ALTERNATE FASTENING PATTERN
HORIZONTAL NAIL SPACING IN ACCORDANCE WITH FIG. 1 OR FIG. 2.
VERTICAL NAIL SPACING ALLOWED ANYWHERE WITHIN NAIL ZONE.
< <
LINE_
too
NOA No.: 15-1215.10
Expiration Date: 12/01/20
Approval Date: 05/26/16
Page 5 of 6
A
R1
HERITAGE WOODGATE & HERITAGE PREMIUM SHINGLES
FIG. 4 FASTENING PATTERN
All dimensions are in inches
v' 7� it 6<�
'---------------------"--.._...._
• •
39-3/8"
9 3/8' I 6'h" 7X2" 1 i 13 1/4"
) <->
------------------------ --------------- -----
------------------------`--------------
5-5/8" "ExposI
END OF THIS ACCEPTANCE
NOA No.: 15-1215.10
Expiration Date: 12/01/20
Approval Date: 05/26/16
Page 6 of 6
SCANNED
BY
' M11AWnDADESt. Lucie County
M 11AM �QADE MIAMI-DADE COUNTY
® . PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOb'tIC RESOURCES (RER) 11805 SW 26 Skeet, Room 208
BOARD AND CODE ADMINISTRATION DIVISION T(786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.wv/economy
CGI Windows and Doors, Inc.
10100 NW 25e' Street
Miami, FL 33172
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER-
Product Control Section to be used in Miami Dade -County and other areas where allowed by the Authority
Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right
to have this product or material tested for quahty assurance purposes. If this product or material fails to
perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may
immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER
reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control
Section that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code, including the High Velocity Hurricane Zone.
DESCRIPTION: Series "Sentinel 110" Aluminum Single Hung Window— S.M.I.
APPROVAL DOCUMENT: Drawing No. W14-21, titled "Series Sentinel 110 AIuminum S.H. ti,Tdw.
(S.M.I.)", sheets 1 through 9 of 9, dated 02/02/10, with revision C dated 12/20/17, prepared by AI-Farooq
Corporation, signed and sealed by Javad Ahmad, P.E., bearing the Miami -Dade County Product Control
Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County
Product Control Section.
MISSILE IMPACT RATING: Small Missile impact Resistant.
LABELING: Each unit shall bear a permanent label with the manufacturer''s name or logo, city, state,
model/series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise
noted herein.
RENEWAL of this NOA shall be considered after a renewal app&cation has been filed and there has been
no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change
in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement
of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure
to comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No. 15-0512.09 and consists of this page 1 and evidence pages E-1, E-2 and E-3, as
well as approval document mentioned above.
The submitted documentation was reviewed by Manuel Perez, P.E.
NOA No. 17-1011.15
MIAMI-DADE COUNTY Wlll,,4�1
Expiration Date: November 13, 2019
Approval Date: January 11, 2018
If 1,6 Page 1
CGI Windows and Doors. Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMTTED
1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's
A. DRAWINGS
1. Manufacturers die drawings and sections.
(Submitted under NOEL No. 14-0522.04)
2. Drawing No. W14-21, titled "Series Sentinel 110 Aluminum S.H. Wdw. (S.M.I.)",
sheets 1 through 9 of 9, dated 02/02/10, with revision A dated 04/10/15, prepared by
Al-Farooq Corporation, signed and sealed by Javad Abroad, P.E.
B. TESTS
1. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
2) Large Missile Impact Test per FBC; TAS 201-94
3) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked -up drawings and installation diagram of a series 7500 PVC fixed
window, to qualify DuPont "Butacite" PVB interlayer, Duraseal(b and Super Spacer(O
insulating glass spacer, prepared by Certified Test Laboratories, Test Report No.
CTLA-3056 WA, dated 03/03/l5, signed and sealed by Ramesh C. Patel, P.E.
2. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
2) Large Missile Impact Test per FBC, TAS 201-94
3) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked -up drawings and installation diagram of a series 7400 PVC project
out window, to qualify DuPont "Butacite" PVB interlayer, Duraseal® and Super
Spacer® insulating glass spacer, prepared by Certified Test Laboraturies, Test Report
No. CTLA-3056 WB, dated 03/03/15, signed and sealed by Ramesh C. Patel, P.E.
3. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
2) Large Missile Impact Test per FBC, TAS 201-94
3) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked -up drawings and installation diagram of a series 238 aluminum
fixed window, to qualify DuPont "Butacite" PVB interlayer, DurasealO and Super
Spacer® insulating glass spacer, prepared by Certified Test Laboratories, Test Report
No. CTLA-3056 WC, dated 04/16/15, signed and sealed by Ramesh C. Patel, P.E.
4. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4) Small Missile Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC, TAS 203-94
6) Forced Entry Test, per FBC 2411.3.2.1. and TAS 202-94
- along with marked -up drawings and installation diagram of series "Sentinel 110"
aluminum single hung windows, prepared by Certified Testing Laboratories, Inc., Test
Report No. CTLA-3009-WD, dated 04/25/14, si ed and sealed by Ramesh C. Patel,
P.E. (Submitted under -1VOANo. 14-0522.04) l
Man50=1011.15
, P.E.
ProductC tminer
NO k
Expiration Date: November 13, 2019
Approval Date: January 11, 2018
E-1
CGI Windows and Doors. Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBNHTTED
C. CALCULATIONS
1. Anchor verification calculations and structural analysis, complying with FBC 5'
Edition (2014), dated 10/20/14, prepared by Al-Farooq Corporation, signed and
sealed by Javad Ahmad, P.E.
(Submitted under NOA No. 14-0522.04)
2. Glazing complies with ASTM E1300-09.
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER)
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 14-0916.10 issued to Kuraray America, Inc. for their
"Butacite® PVB Glass Interlayer" dated 04/25/15, expiring on 12/11/16.
2. Notice of Acceptance No. 14-0423.17 issued to Eastman Chemical Company (NIA)
for their "Saflex Clear and Color Glass Interlayers" dated 06.119/14, expiring on
05/21/16.
F. STATEMENTS
1. Statement letter of conformance, complying with FBC 5th Edition (2014), and of no
fmancial interest, dated May 15, 2014, issued by Al-Farooq Corporation, signed and
sealed by Javad Ahmad, P.E.
(Submitted under NOA No. 14-052E_04)
2. Laboratory compliance letter for Test Report No. CTLA-3009-WD, issued by
Certified Testing Laboratories, Inc., dated 04/25114, signed and sealed by Ramesh C.
Patel, P.E.
(Submitted under NOA No. 14-052E_ 04)
3. Test Proposal for the qualification of Butacite® PVB glass interlayer by DuPont as
well as Duraseat® and Super Spacer& Standard warm -edge flexible insulating glass
spacers, dated December 16, 2014, issued by RER, Product Control Section, signed by
Jaime Gascon, Supervisor-
G. OTHERS
1. Notice of Acceptance No. 14-0522.04, issued to CGI Windows & Doors for their
Series "110 Sentinel" Aluminum Single Hung Window — S.M.I., approved on
11/13/14 and expiring on 11/13/19.
LJ
Manuel r P.E.
Product Contr Ex finer
NOA No. 17-1011.15
Expiration Date: November 13, 2019
Approval Date: January 11,2018
E-2
CGI Windows and Doors, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
2. NEW EVIDENCE SUBMITTED
A. DRAWINGS
1. Drawing No. W14-21, titled "Series Sentinel 110 Aluminum S.H. Wdw. (S.M.I.)",
sheets 1 through 9 of 9, dated 02/02/10, with revision C dated 12/20/17, prepared by
Al-Farooq Corporation,, signed and sealed by Javad Abroad, P.E.
B. TESTS
1. None.
C. CALCULATIONS
1. Anchor verification calculations and structural analysis, complying with FBC 6th
Edition (2017) dated 09/28/17, revised on 12/27/17, prepared by Al-Farooq
Corporation, signed and sealed by Javad Ahmad, P.E.
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER)
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 16-1117.01 issued to Kuraray America, Inc. for their
"Trosifol® Ultraclear, Clear and Color PVB Interlayers" dated 01/19/17, expiring
on 07/08/19.
2. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company (NIA)
for their "Saflex Clear and Color Glass Interlayers" dated 09/07/17, expiring on
05/21/21.
F. STATEMENTS
1. Statement letter of conformance, of complying with FBC 51 Edition (2014), with
FBC 61 Edition (2017) and of no financial interest, dated September 14, 2017, issued
by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. .
G. OTHERS
1. Notice of Acceptance No. 15-0512.09, issued to CGI Windows and Doors, Inc. for
their Series "Sentinel 110" Aluminum Single Hung Window — S.M.I., approved on
09/03/15 and expiring on 11/13/19.
Manuel er z, P.E.
Product Contr I aminer
NOA No. 17-1011.15
Expiration Date: November 13, 2019
Approval Date: January 11, 2018
E-3
5s 1/a"
FLANGE WIDTH
47 7/16'
D.L.O. (FIX. LITE)
20 9/16" **
MAX.
II II
II II
II , II I
II II �
n
MUNTINS
ICE APPLIED)
47 7/16" I Imz \
111 z
D.L.O_ (VENT) p
U
50 1 /4"
VENT WIDTH
FLANGE k FLANGE ADAPTOR FRAME
SERIES SENTINEL 110 ALUMINUM SINGLE HUNG WINDOW
DESIGN LOAD RATINGS FOR THESE WINDOWS TO BE AS PER
CHARTS SHOWN ON SHEET 2.
APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIDE COMBINATIONS
OF S.H./S.H. OR SINGLE HUNG WDW. WITH OTHER MIAMI-DADE COUNTY
APPROVED WINDOWS USING MIAMI-DADE COUNTY APPROVED MULLIONS
IN BETWEEN.
LOWER DESIGN PRESSURE FROM WINDOWS OR MULLION APPROVAL
WILL APPLY TO ENTIRE SYSTEM.
REQUIREMENTS OF THE12014 (5TH EDMON)/2017 (6TH EDITION) FLORIDA
BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ).
1BY OR 26Y WOOD BUCKS & BUCK FASTENERS BY OTHERS, MUST BE
ncarurn ANn INdAI I Fn An Pn1IATFI Y Tn TRANCFFR APPI IFn PRnnl ICT I nAnS
5 1/2" MAX.
52 1/8"
UCK WIDTI
47 7/16"
D.L.O. (FIX. LITE)
20 9/16" **
MAX.
A� HEAD SILL
,I I.
II II
II II
II II
II,11
II -i R
11 11
B I( II
II II
�
it II
I; ,, 11
II / II
II II
II 11
II II I
II C1 11
n p
I
47 7/16"
D.L.O. (VENT)
50 1/4"
VENT WIDTH
EQUAL LEG FRAME
CENTER ANCHOR REQUIRED WHEN
SPACING EXCEEDS 20 9/16"
FALSE MU
15LIRFACE
OPTIONAL
a
FAIL,
EQUAL LITES 1PINDOITS
DESIGN LOAD CAPACITY - PSF
FIANCE DWB.
DUCK DIMS.
GLASS TYPES V&'Cl'
WIDTH
HEIGHT
wiDTH
HEIGHT
EXL(+)
TNT-(-)
19-1/8"
26-1/2'
37'
49"
53-1/8"
26"
la-1/8'
25-1/2"
36"
48"
52-1/8'
25'
B0.0
134.0
50.0
134.0
80.0
134.0
00.0
134.0
80.0
134.0
19-1/e"
26-1/2'
37"
49"
53-1/8"
38-3/8"
18-1/8'
25-1/2"
36'
48"
52-1/8"
37-3/8'
80.0
134.0
00.0
134.0
80.0
134.0
80.0
134.0
80.0
134.0
19-1/5"
26-1/2"
37'
49"
53-1/8"
50-5/8"
18-1/0"
25-1/2"
36"
48'
52-1/8"
49-5/8"
80.0
134.0
80.0
134.0
80.0
134.0
80.0
124.3
80.0
110.4
19-1/8'
26-1/2'
37"
49"
53-1/8"
63"
18-1/8"
25-1/2"
36"
48"
52-1/8"
62"
80.0
134.0
8D.0
134.0
80.0
134.0
80.0
109.9
80.0
95.5
19-1/8"
26-1/2"
37"
49"
53-1/8'
76'
18-1/8'
25-1/2"
36"
48"
52-1/8'
75"
60.0
105.0
80.0
105.0
80.0
105.0
80.0
102.1
80.0
58.3
19-1/8"
26-1/2'
37'
46-1/2'
B5"
18-1/8"
25-1/2"
36"
45-1/2"
90.0
105.0
60.0
105.0
80.0
105.0
EQUAL LITES
T1'P. . . BUCK DIMS . . $" T"P•
FLANGE FRAME
BUCK DIMS
a EQUAL LEG FRAME
BUCK DIMS _I
II
UN
/8- HEAT STREN'D GLASS
.090' Interlayer
Saflex Clear And Color Glass
By 'Eastman Chemical Co.'
.090" Interlayer
Tresifol PVB
By 'Kuraray America, Inc.'
TEMP. GLASS
a
� m SILICONE
GE 1200
N DOW CORNING 899
DOW CORNING 995
a /
0 /
k 1
N GLA@S TXPR `C'
5/18" OVERALL LAM. GLASS
1/8' HEAT STREN'D GLASS
.060 Interlayer (For Loads Upto 105 Psf)
.090 Interlayer (For Loads Above 105 Psf)
Saflex Clear And Color Glass
1 /4" AIR SPACE R By 'Eastman Chemical Co.'
P. GLASSI Trosifol PVB
1/8" TEM
By `Kuraray Americo, Inc.'
1/8" TMP. GLASS
al
F IC SILICONE
m GE 1200
N DOW CORNING 899
rl IA �DOW CORNING 995
:•� it ii �� XL EDGE SPACER
3T. STEEL BY 'CARDINAL'
OR
o DURASEAL BY 'QUANEX'
OR
W E9 SUPFR SPACER BY 'OIIANEX'
TYPICAL ANCHORS
SEE ELEV.
1 BY I FOR SPACING
WOOD BUCK
d° •i de: a. 'i jy 'EDG DIST.
4 tl d d a d
a a d e
O I
I �l it
M2
I� I
S5
I!I.
I I
mg
J
C
II II
ljl
II
SWEEP LOCK
OPTIONAL TO
EGRESS LOCK
AT SILL
OF--ln E8
� e4
Fi
! jl jl
ip
i
a I i 11 G
TYPICAL ANCHORS
FLANGE.
o I DIST. a. �
2 3/8- MIN.
N �
WHEN USED THE MIN. WOOD BUCK
DEPTH SHALL BE 2%". THE USE OF
DEEPER OR BEVELED WOODBUCKS IS
PERMITTED.
mi
& MULLION ANCHORS
SEE SEPARATE NOA
BUCK WIDTH BUCK WIDTH
i II
FT,ANGE.
S/2 TYP. O
3S
iORS
1BY
WOOD 6UCK
'� d i• a Q a' a � �•d n a s •v
a.'
TYPICAL ANCHORS
SEE EL.EV.
FOR SPACING
'EDGE- .DIST.• xQ
a d_
TYPICAL ANCHORS
SEE ELEV.
FOR SPACING
In
GMETAL
DIST. _ %STRUCTURE o
EDGE
/ 3
TYPICAL ANCI
SEE ELEV.
FOR SPACING
t3L
SWEEP LOCK
OPTIONAL TO
EGRESS LOCK
AT SILL
--F _ —
EQUAL LEG FRAME CAN BE INSTALLED DIRECTLY
o i INTO WOOD, CONCRETE OR METAL STRUCTURES
a I WITHOUT THE NEED OF A WOOD BUCK.
z
2 3/8" MIN.
Aa
E6
1
9 ;/a" MIN
ILLUSTRATIVE DTLS. ONLY
EXT. OR INT. FINISHES
NOT BY CGI . _
HOUSE WRAP
NOT BY 001
I
R
O
22
z
0
k-
0
m
w
w
U
to
TYPICAL ANCHORS
SEE ELEV,
FOR SPACING
SWEEP LOCK
OPTIONAL TO
EGRESS LOCK
AT SILL
z
5
-11
WOOD STRUO
NOT BY CGI
TYPICAL ANCHORS: SEE ELEV. FOR SPACING
A SMS (Fu=74 KSI, Fy=57 KSI)
INTO 2BY WOOD BUCKS OR WOOD STRUCTURES
1-1/4" MIN. PENETRATION INTO WOOD
ITEM
PART #
QUANTITY
DESCRIPTION
E1
CGI-100
1
FRAME HEAD
E2
CGI-101
1
FRAME SILL
E3
CGI-102
2
FRAME JAMB
E4
CGI-103
1
MEETING RAIL
E5
CGI-104
1
LOCK RAIL
E6
CGI-105
1
HANDLE RAIL
E7
CGI-106
2
SASH RAIL
ES
CGI-107
AS REQD.
5/16" GLAZING BEAD
E9
CGI-108
AS REQD.
0.700" GLAZING BEAD
E10
CGI-109
AS REQD.
FRONT FLANGE ADAPTOR
El
CGI-110
AS REQD.
NAIL FIN ADAPTOR
E12
CGI-135
1
FLANGE FRAME HEAD
E13
CGI-136
2
FLANGE FRAME JAMB
E14
CGI-137
1
FLANGE FRAME SILL
E17
CGI-605
OPTIONAL
SCREEN FRAME
M1
CGI-362V
AS REQD.
GLAZING BULB VINYL (OUROMETER
M2
CGI-1II
OPTIONAL
SCREW COVER
M3�
CGI-112
AS REQD.
EQUAL LEG COVER/SHIM, 3" LONC
M9
SUPER BOOST
2/ WDW.
SPIRAL BALANCE
M10
-
2/ WDW.
SLOCK/TACKLE BALANCE
M11
W23201NG
AS READ.
PILE VWTH CENTER FIN
M12
CGI-129
1/ WDW.
EGRESS LOCK
M13
2/ WDW.
HANDLE RAIL END CAP
M1_4
_CGI-131
U6018WN
-
D BULB-T SLOT
M15
CGI-133
4/ WDW.
SASH GUIDE(SPIRAL BALANCE)
MIS
COI-130
2/ WDW.
SASH TOP GUIDE(SPIRAL BALANCE;
M17
A30730401-32
1/ WDW.
CAM LOCK
1,118
CM- 132
2/ WON'.
SASH STOP, 2" LONG
M19
-
2/ LITE
SETTING BLOCK
M20
CGI-125
2/ WDW.
SASH CAM (B/T BALANCE)
M21
-
2/ WDW.
B/T Bk ANCE TAKE OUT CLIP
M22
146-6
2/ WDW.
WEEP COVER
M23
CGI-134
-
SILL SPACER
S2
-
2 OR 3/CORNER
# 10 X 1 1/4" I.G. PHL. PH. SM
S4 _
-
4/ WDW.
# 8 X 1/2" PH. SMS. ST/ST B4L
S5
-
2/ WDW.
# 8 X 1" LG. FH.. SMS. ST/ST.
S6
-
2/ LOCK
# 6 X 1/2'. LG. PH. SMS. 0 CC
T-I
tit I
911
745
O65 1
ttP.
--q 1.015 f-
E72 FLANGE FRAME HEAD f E7 FLUSH FRAME HEAD
3.
FLANGE FRAME SILL
2.
�s
1
0
t:s FLUSH FRAME SILL
Et' FLANGE FRAME JAMB
E3 FLUSH FRAME JAMB
.490
Ti
.1201 r
.70� �50 TYP.
.70r•-,050 7YP.
11 1
NAIL FIN ADAPTER
- 4 1.007 F-
/5 1.365 15 2.t113
CEO MEETING RAIL
1.2201
1.043
L R}LJ S.
065
TYP.
1.015 Fo-
O LOCK RAIL
5
FRAME TOP CORNER
' I
FRAME BOTTOM CORNER j
I