Loading...
HomeMy WebLinkAboutDOOR REPLACMENT PLANSt FILE COPY RECEIVED DEC 1=9 2010 Permitting Department sty Wrip County ST. LUCIE CO NTYBUILDING DIVISION REVIEWED FOR COM12tJE I D REVIEWED BY \ l e... PLANS AND SITE OR NO : KEPT ON WILL BE � ALL MANUFACTURES LABLES SHOWING U FACTORS AND SHGC COMPLIANCE WITH FBC ENERGY CODE MUST REMAIN ON ALL DOORS AND WINDOWS ONLY. UNTIL INSPECTONS ARE APPROVED THESE PLANS AND ALL PROPOSED WORD NEW DOOR & SIDELIGHT TO BE IMPACT RESISTANTARE SUBJECT TO ANY CORRECTIONS SHUTTERS NOT REQUIRED. REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES, OPENING PRODUCT DESIGN OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS NO. WDTH. HGT. FTG. ZONE POS. NEG. (N.O.A.#) POS. NEG. 1 1 53 1 29.44 4 36.1 1 -39.3 1 FL22378.5 55.0 1 -55.0 1 FRONT ENTRY - LSMI REPLACE EXISTING DOOR & SIDELIGHT AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOOR & SIDELIGHT. NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS. ALL DOOR & SIDELIGHT FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 1/4" TAPCON SCREWS INTO CONCRETE WITH A MINIMUM 1 1/4" PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS. LESS THAN 30% OF STRUCTURE'S VALUE. NOT A RENOVATED BUILDING.. EXEMPT FROM 2017 ENERGY CONSERVATION CODE. SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES MEAN ROOF HEIGHT = 13 FT 6 IN DICKINSON CONDO UNIT 5833 HONEYBELL COURT FORT PIERCE, FLORIDA DOOR REPLACEMENT PLAN