HomeMy WebLinkAboutTOPOGRAPHIC SURVEYSURVEYOR'S GENERAL NOTES AND REPORT:
1. UNLESS IT SEARS THE SIGNATURE AND THE ORIGINAL
RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND
MAPPER, THIS DRAWING, SKETCH, PLAT OR MAP IS FOR
INFORMATIONAL PURPOSES ONLY AND IS NOT VALID.
i
EXISTING 4' k.
2. THE LAST DAY OF FIELD WORK PERFORMED FOR THE
CONCRETE 11.4
INITIAL SURVEY EFFORT WAS OCTOBER 19, 2018.
SIDEWALK
SUBSEQUENT ADDITIONS, DELETIONS AND/OR UPDATES, IF
ANY, ARE REFLECTED IN THE DRAWING REVISIONS.
3. THIS SURVEY HAS BEEN PREPARED FOR THE EXCLUSIVE
EXISTING
5' X 9'
BENEFIT AND USE OF THE PERSONS ANDTOR ENTITIES
WOOD STAIRS
NAMED HERON FOR THE PURPOSES IDENTIFIED HEREON
(17) 10-0'''\\\
ONLY. UNLESS OTHERWISE STATED, CERTIFICATION OF
PIUNGS \
THIS SURVEY MAP APPLIES ONLY TO THE STANDARDS OF
WOOD RAIL
PRACTICE SET FORTH BY THE FLORIDA BOARD OF
PROFESSIONAL SURVEYORS AND MAPPERS IN CHAPTER
5J17 FLORIDA ADMINISTRATIVE CODE, PURSUANT TO
52 V; 70.7
SECTION 472.027, FLORIDA STATUTES. THE CERTIFICATION
15,8
IN NO WAY CONSTITUTES NEITHER GUARANTY NOR
E
DECK
WARRANTY TO ANY OTHER INFORMATION NOT SHOWN
WAD
HEREON. ADDITIONS, DELETIONS OR REVISIONS TO THIS
fipECK
DRAWING BY OTHERS ARE NOT PERMITTED AND THIS
WOpp DE
SURVEY MAY NOT BE TRANSFERRED WITHOUT THE
EXPRESSED WRITTEN PERMISSION OF THE SIGNING
EXISTINGSURVEYOR.
THIS SURVEY IS NOT VALID FOR ANY OTHER
EXISTING 4.6' X 6'
PURPOSE OTHER THAN INTENDED BY THE SIGNING
5' X 5' WOOD RAMP
SURVEYOR.
CONCRETE
4. WITH EXCEPTION TO WHAT HAS BEEN FIELD LOCATED AND
LANDING CLUB HOUSE
SHOWN ON THIS SURVEY, THE SURVEYOR MAKES NO
AND
GUARANTEES THAT THE UNDERGROUND UTILITIES SHOWN
RECREATION HALL
HEREON COMPRISE ALL SUCH UTILITIES IN THE AREA,
EITHER IN SERVICE OR ABANDONED. SUBSURFACE AND/OR
AERIAL ENCROACHMENTS, IF ANY, WERE NOT LOCATED
AND/OR DEPICTED ON THIS SURVEY UNLESS NOTED OR
0.20' WI
IDENTIFIED.
WOOD RETAINI
5. THE HEREON DESCRIBED PROPERTY APPEARS TO LIE
WITHIN FLOOD ZONE "X" (OUTSIDE 0.2% CHANCE), AS SHOWN ON FLOOD INSURANCE RATE MAP (FIRM) NUMBER
12111CO089J, COMMUNITY NUMBER 120285, PANEL 0089, /
SUFFIX J. MAP REVISED DATE FEBRUARY 16, 2012. MAP
INDEX DATE FEBRUARY 16, 2012.
PVC GATE WITH
6. THIS IS A TOPOGRAPHIC SURVEY SHOWING THE EXISTING HANDICAP LIFT
0.20 FEET WIDE WOOD RETAINING WALL AND ADJACENT
IMPROVEMENTS ONLY.
DOUBLOON LANE
BENCHMARK No. 12
"PK"/TAB NO IDENTIFICATION
ELEVATION 6.89 FEET NAVD 1988
WER ON
POST
0
4' PVC
FENCE
CONCRETE
POOL DECK
+I4.60
A +14.55
+ 14.56 \
SHOWER ON
PVC POST
+14.50
SET TEMPORARY
BENCHMARK No. 3
"PK" NAIL
NO IDENTIFICATION
'59 ELEVATION 14.49 FEET
Ik NAVD 1988
14.65
o -
2
+14.50 m
0
0
6 +14.50
S
F
+ 14.51
/-PVC GATE
+14.50
14.79
f4.66
0 10 20
SCALE.• (1 Inch a 20 Feat)
1z
PVC POST
f2.
j
.01
2
12.07
PVC GATE
14.67
ISTETE 426
+14.48
.64
STEPS 1208
+14.57
4' PVC
+14.62
FENCE
14.25
f
_ 14.47
SET TEMPORY BENCHMARK No. 2
"PK" NAIL NO IDENTIFICATION14 ss
ELEVATION 14.44 FEET NAVD 1988 36 `4 PVC
FENCE
VERTICAL DATUM AND CONTROL NOTES:
THE ELEVATIONS SHOWN HEREON ARE REFERENCED TO THE NORTH AMERICAN VERTICAL DATUM OF 1988
(NAVD 1988) AND ARE DISPLAYED IN U.S. SURVEY FEET AND DECIMAL PARTS THEREOF.
ORIGINATING BENCH MARK(S) = TOP OF POURED IN PLACE CONCRETE MONUMENT STAMPED'DEP 9477 A35"
ELEVATION 3.61 FEET NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 1988).
BENCHMARK NO. 12: TOP OF "PK" NAIL/TAB NO IDENTIFICATION ELEVATION 6.89 FEET NORTH AMERICAN
VERTICAL DATUM OF 1988 (NAVD 1988). SEE SKETCH FOR LOCATION.
OCEAN RESORTS CO-OP, INC.
5101 NORTH HIGHWAYAIA
FT. PIERCE, FLORIDA 34949-8203
r
03 3.75'
0 1�
G
t�
7J 4.00'
�m IL-
1
4.
U mU
G
d
SET TEMPORARY BENCHMARK- TRAV. PT # 2: TOP OF "PW NAIL NO IDENTIFICATION ELEVATION 14.44 FEET
NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 1988). SEE SKETCH FOR LOCATION.
SET TEMPORARY BENCHMARK- TRAV. PT. # 3: TOP OF "PK" NAIL NO IDENTIFICATION ELEVATION 14.49 FEET
NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 1988). SEE SKETCH FOR LOGATION.`�"'
LEGEND '\��•.�\.!IU,;•j',� ^^'
k208 EXISTING VERTICAL ELEVATION
,� u dVAII�- CARTER ASSOCIATES, INC
CONSULTING ENGINEERS AND LAND SURVEYORS is "�1
1708 21st STREET, VERO BEACH, FL 32960 oa oo^:' �I�c::PG '
TEL:(772) 562-4191 FAX: (772)582-7180
1.93' CONC.
TAINING WALL
C408'
t4.24
3
t
1G
11'•
14.59
/0.20' WIDE
WOOD
RETAINING
WALL
14ss
+14.50
2
O
0O
14.74
m
+14.50
q
O
r
90'
O
+14.50
3.95'
3.25'
+14.51
3.96, 4.20'
1
+14.50
12.4
14.M 4.80'
12.J 4.11' CONC.
RETAINING WALL
..07
Of
0.75'
12.07
CONCRETES `O
STEPS 12.08 +'4.46
PILING DETAIL
SCALE 1" =10'
O 03W10, 2010
Imes TOPOGRAPHIC SURVEY
SG
smucvear PILING AND RETAINING WALL LOCATION
tA[LBBdn OCEAN RESORTS CO-OP, INC., ST.LUCIE COUNTY, FLORIDA
11
1 OF 1