Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEPlanning & Development Services Department RECEIVED Building & Code Regulations Division DEC tl �AtA 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-15 3 5T, Weie county, WRl)00 Certification for Design Load Compliance Permit#: Occupancy Type: —N/A—Construction Type: N/!Ll INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) SCANNED o Residential Addition BY ,,a� Any accessory structure requiring a building permit St• Lucie Count o Any non-residential structure. y • Note: Farm not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code.Fft Edition with 20 17 Supplements using ASCE 7-10 2. Structure Designed as (check one): _Enclosed _Partially Enclosed Open 3. Risk Category: xx 1 _II _III _ IV Exposure Category: B xx C _D 4. Design Wind Velocity 170 mph _ASD xx LRFD End Zone Width: 3 ft S. Mean Roof Height NIA ft Roof Pitch: N/A :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on losgft @ 15'MRH, clearly label on all plan openings): Zone 1: N/A Zone 2: N/A Zone 3: N/A Zone 4: +/-47.7 Zone 5: +/-47.7 Garage: N/A 7. Design Loads: Floor: WA PSF Roof/Dead: N/A PSF Roof/Live: NrA Balcony: wA PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF 8. Were Shear Walls Considered For Structure? xx Yes _Not Applicable Explain Why Not: f 9. Is A Continuous Load Path Provided? Xx Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? _Yes I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: Slgnature,:Date, and Seal Allen Wieder Print Name Wieder Engineering, Inc FL PE 43444 Cert # & Co. Cert Auth. 11718 SE Federal Hwy #373, Hobe Sound, FL 33455 Company Name & Address Revised 07/25/2014