Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCERECEIVED e Planning & Development Services Department • guilding & Code Regulations Division DEC 0 4 20% 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462- 5S3 ST. Lucie County, Permitting Certification for Design Load Compliance Project Name: MIS,-uQNh Y VLeirCS — GI.OP4 -hibUSE 1,p,y Project Address: 41atMMnN 13 kDAD # CT1-1-�1 . 131_V M - �. VLEKL.�, FL_ 34' / T6 Permit #: 1'8 /Z 0 40"Z Occupancy Type: ,e-2 it- (r R 1Lonstruction Type: V B INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition SCANNED o Any accessory structure requiring a building permit BY .��Any non-residential structure. St. LUCID' Count � • Note: Form not required for interior renovations provided that no exterior structural elements ar affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code Mfth-Edition with 20 17 Supplements using ASCE 7-10 2. Structure Designed as (check one): XX Enclosed _Partially Enclosed _Open 3. Risk Category: _I XX II _III _ IV Exposure Category: _B _C XX D 4. Design Wind Velocity 170 mph _ASD xx LRFD End Zone Width: 3 ft S. Mean Roof Height 15 ft Roof Pitch: 6 :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings) Zone 1:+26.4/42.0 Zone 2: +26.41-73.1 Zone 3: +26.4/-196.1 Zone4:+45.91-19.8 Zone 5:+45.91a1.4 Garage: N/A 7. Design Loads: Floor: NIA PSF Roof/Dead: 35 PSF Roof/Live: 20_ Balcony: N/A PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: NIA PSF Railings: N/A PSF B. Were Shear Walls Considered For Structure? xx Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? XX Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? _Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: Allen Wieder FL PE 43444 Signature, Date, and Seal Revised 07/25/2014 Print Name Wieder Engineering, Inc Cert # & Co. Cart Auth. 11718 SE Federal Hwy #373, Hobe Sound, FL 33455 Company Name & Address La F L�&]� ��i 4, Planning & Development Services Department RECEIVED Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 - (772) 462-15 DEC 0 4 2018 Certification for Design Load Compliance ST. Lucie County, Permitting Project Name: /7715Sfa n1 Project Address: #1 N '71vJ 00*u 4, C'tm- $wer rT-- / 16- 5-tO7 alp Permit q: Type: U Construction Type: V V INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessary structure requiring a building permit �— Any non-residential structure. ' Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the q above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 04i 1. DESIGN CODE: Florida Building CodeFifth Edition with 20 17 Supplements using ASCE 7-10 2. Structure Designed as (check one): XX Enclosed _Partially Enclosed _Open 3. Risk Category: _I XX II _III IV Exposure Category: _B _C XX D 4. Design Wind Velocity 170 mph _ASD xx LRFD End Zone Width: 3 ft 5. Mean Roof Height 15 ft Roof Pitch: 6 :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1:.26.4i42.0 Zone 2: *26.41-73.1 Zone 3: '26'4/-108'1 Zone 4:+45.91-19.a Zone 5:'45.9i-61.4 Garage: N/A 7. Design Loads: Floor: NSA PSF Roof/Dead: 35 PSF Roof/Live: 20 Balcony: WA PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A P5F R. Were Shear Walls Considered For Structure? Xx Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? XX Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? _Yes I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: Allen Wieder FL PE 43444 Signature, Date, anii Seal Print Name Wieder Engineering, Inc Cert N & Co. Cert Auth. 11718 SE Federal Hwy #373, Hobe Sound, FL 33455 Company Name & Address Revised 07/25/2014 ()IwTeam 3601-A Crossroads Parkway Fort Pierce, FL 34945 405423505,405423535 Gale Insulation BUILDER: Richard K Davis Construction SUBDIVISION: JOB ADDRESS:3163 Hammond Rd CITY: Fort Pierce PERMIT#: LOT/BLOCK: INSULATION INSTALLATION CERTIFICATE The undersigned hereby certifies that insulation has been installed in the above property as follows: 1. Exterior CBS walls have been insulated with to thickness of inches, which according to will yield an "R" value of 2. Exterior frame wall has been insulated with to a thickness of inches, which according to will yield an "R" value of 3. Ceiling Area (flat) has been insulated with Spray Foam to a thickness of 5•5" inches, which according to BASF will yield an "R" value of 20 4. Ceiling Area (vaulted) has been insulated with to a thickness of inches, which according to will yield an "R" value of 5. Interior knee walls have been insulated with Spray Foam to a thickness of5.5" inches, which according to BASF will yield an "R" value of 20 6. Garage common walls adjacent to conditioned living space have been insulated with to a thickness of inches, which according to will yield an "R" value of General Contractor/Builder Signature Insulation Contractors Signature License # CGC1512179 THE AFFIANT, Jeremy Theisen IS PERSONALLY KNOWN TO ME. Sworn to and subscribed before me this 29 day of October 20+9 Notary Public, State of Florida a�d2` :c-SL;ru(nc�idat�n A.G,S:'UIIxpires =Iq Ja:: i3.1p"tl ny It}�dR FRrdutdt>,bips_Pd5Ria9z1' N00UPeOs, GALE INSULATION Richard K Davis Construction 405423505,405423535 CERTIFICATE OF NO -BURN PLUS XD -INSTALLATION JOB ADDRESS: 3163 Hammond Rd, Fort Pierce, FL BUILDING PERMIT# This letter is to certify that Gale Insulation has installed approximately 9,580 square feet of No - Burn Plus XD in accordance with the No -Burn Plus XD Manufacturer's Specification. (Roof Area) INSULATION CC# CGC1512179 GALE INSULATION CERTIFICATE DATE: 10/29/19 THE AFFIANT, JEREMY T SEN, IS PERSONALLY KNOWN TO ME Sworn to and subscribed before s �e t is 29 day of October , 2019. Notary public, State of Florid/a"�'`n -e'l '•./—°j8*, il'NWf[i254'IFE7 L ''`€!n29 3601-A CROSSROADS PARICIVAY . FT. PIERCE, FL 34945 FT. PIERCE (772) 465-9191 RIVIERA BEACH (561) 842-1893 MIAMI (305) 625-8397 TOLL FREE (866) 619-8456 a FAX (772) 489-6758 P.fA9 �Fo Planning & Development Services pen,; 061pp0 Building & Code Regulation Division sE 4!ce�e a • 2300 Virginia Ave - k e t • Fort Pierce, FL 34982 772-462-2172 Fax 772-462-6443 CERTIFICATE OF TERMITE TREATMENT ll�j2-t�c�l2. CONSTRICTION SAIL TREATMENT PERMIT #: i� f 2-c�-zi Z 4 JOB ADDRESS: S 16S boo tctloxd QP EEPe.,,,e 3`Ft YC BUILDER/CONTRACTOR: 4 K �Gk.✓rS PEST CONTROL CONTRACTOR: EVICT -A -BUG TERMITE & PEST CONTROL INC. PEST CONTROL LICENSE #: JB175775 We, the undersigned, hereby certify that we have pretreated the above described construction for subterranean termites in accordance with the standards of the National Pest Control Association. Square feet if area treated: 145;0 L r Percentage of solution:.05% Date of Treatment: d Footing 1't Treatment Re -Treat Driveway 1'` Treatment Re -Treat Other 1't Treatment Re -Treat Chemicals used: DOMINION 2L Total gallons used: 179 Time of Treatment: 10 , fly Slab 1't Treatment Re -Treat Pools 1't Treatment Re -Treat for Final Inspection of Exterminator Date Note. There must be a completed form for eaCA requir€d treatment or re -treatment and this form must be on the job site to be picked up by the inspector at time of each inspection or the scheduled inspection will fail and a re -inspection fee charged. FBC104.2.6 Certificate of Protective Treatment for prevention of termites A weather resistantjobsite posting board shall be provided to receive duplicate Treatment Certificates as each required protective treatment is completed, providing a copy for the person the permit is issued to and another copy for the building permit files. The Treatment Certificate shall provide the product used, identity of the applicator, time and date of the treatment, site location, area treated, chemical used, percent concentration and number of gallons used, to establish a verifiable record of protective treatment. If the soil chemical barrier method for termite prevention is used, final exterior treatment shall be completed prior to final building approval. St Lucie County requires for the final inspection for CO, a Permanent Sticker to be placed on the electrical panel box cover, listing all the treatments and dates of applications. Revised 7/24/2014 - Termite Inspection Christ is _ •I 1 72-323-7921 • Termite Pretreatment Toll free: 1-811-385-9998 • Pest Control • Rodent Service 9771P AM 772-349-5889 • Fire Ant Lawn Service Email: Evictabug@gmail.com • Whitefly Treatment 4293 SW High Meadows Ave. • Licensed & Insured Lic. J617 Palm City, FL 34990 Notice of Preventative Treatment for Termites (as required by Florida Building Code (FBC) 104.2.6, 105.10 & R318.1 and Broward County Chapter FBC 105.2.2) PEST PREVENTION I FIRE ANT SERVICE I TERMITE SERVICE I RODENT EXCLUSION & REMOVAL I WHITEFLY TREATMENT DATE OFSERVICE Z TIME 16 ' C DEVE//L�1O__P�MENT NAME (PROJECT) CONTjditCTOC�S NAME, � r CONTTAACT PERSON 1.V7. ie: KK ��<C/ 4411��))�`--((..li�� Il✓✓CCl/ STRUCTURE ADDRESS (LOTIBLOCK) CITY, STATE C LINTY >lcu t C�cA D �T t,� � _ r �.c -Q NOTES ZIP CO% ❑ FLOATING ❑ MONOLITHIC ❑ PATIO ❑ GARAGE ❑ DRIVEWAY ❑ STEM WALUFOOTERS ❑ ADDITION ❑ CUTOUTS ❑ FOOTER ❑FRONT ENTRY ❑ RETREAT ❑ BORA CARE TREATMENT CIPLUMBING CUTOUTS ElSIDEWALKS ❑ TAMP & TREAT TREAT ONLY Jp1FINAL U ❑ POOL DECK ❑ OTHER PRODUCTS tt �/ ❑ BASELINE ❑ DOMINION 2LACTIVE INGREDIENT ❑ TERMIDOR SC ❑ BORACARE ❑ PREMISE ❑ TALSTAR ❑-0THER IJ ACTIVE INGREDIENT 0IMIDACLAPRID O BIFENTHRIN ❑ DISODIUM OCTABORATE TETRAHYDRATE CONCENTRATION i 12 ❑ .06% ❑ .1% ❑ .12% ❑ .25% �1.05% ❑ 23% ❑ 9% ❑ OTHER GAALLLONSAPPLIED SQUARE FOOTAGE LINEAR FOOTAGE 7 <;7(,3� YES ❑ NO --MEASURED OR VERIFIED PER PLANS T_�— YES ❑ NO DETAILS "Certificate of Compliance" As per 104.2.6,105.10 & R318.1 FBC - If soil chemical barrier method for termite prevention is used. Final exterior treatment shall be completed prior to final building approval. Certificate of Compliance: The building has received a complete treatment for the prevention of subterranean termites. Treatment is in accordance with rules and laws established by the Florida Department of Agriculture and Consumer Servic s. (Per the Florida Building Code.) If this notice is for the final exterior treatment, initial and date this line z JIB. 'S'rli� FINAL STICKER ❑ ELECTRICAL PANEL ❑ WATER HEATER ❑ OTHER 1A1 if Y� Payment Terms: Payment due at time of service. A S 7.0 Date r Applicator. E mlA Bug Termite and Pest Control, Inc.) Date Customer (Property Owner or Agent) www.evictabugpestcontrol.com L15 Christ Is ' ®5 fu1Ct-A-BUg hn r--? Termite & Lic. JB175775 Pest Control, Inc. Pest Prevention Termite Protection THIS NOTICE POSTED PURSUANT TO SECTION 104.2.7, FLORIDA BUILDING CODE AND CHAPTER 482. 6, FLORIDA STATUTES Date of WDO Inspection (If Made) ❑Evidence ❑Activity ❑No Activity Date of I ifial T atmant Materials Used Date of Final Ex nor Treatment Materials Used Wood Destroying Organism Treated For This property has been treated and placed under a retreatmenUrepair contract for subterranean Iemiites. This contract is renewable by payment on annual fee. The owner is hereby advised to have this Property inspected annually by Evict -A. Bug Termite & Pest Control, Inc Evict -A- Bug Termite & Pest Control, Inc. provided the termite protection onthisproperty. CALLUS regarding our Pest Prevention, Fire Ant Lawn Servim and Rodent Service. / • 772-323-7921 0 1-877-365-9990[& www.evictabugpestcbntrol.com - evictabug@gmail.com 4293 SW High Meadows Ave. • Palm City, FL 34990 Ca//fa alivaleYourfern/le Guarantee Planning & Development Services suliding & Code Regulation Division 2300 Virginia Ave Fort Plerce, FL 34982 772-462-2172 Fax 772-462-6443 CERT2KCATE OF TERMITE TREATMENT CONSTRUC7ZON SOIL TREATMENT PERMIT #: 1811-a'2612 JOB ADDRESS: �2� /d�w,/.av107 QI! ffPiercE 23 5 Y� BUILDER/CONTRACTOR K 1-JaVrS PEST CONTROL CONTRACTOR: EVICT•A-BUG TERMITE& PEST CONTROL INC. PEST CONTROL LICENSE #: JB175775 We, the undersigned, hereby certify that we have pretreated the above described construction for subterranean termites in accordance with the standards of the National Pest Control Association. Square feet if area treated: 60?— Chemicals used: DOMINION 22L Percentage of solution: .05% Total gallons used: k��D —Date-of Treatment:- O 1 9 _ Time of Treatment: Footing Y' 1st Treatment Re -Treat Driveway 1st Treatment Re -Treat Other 1st Treatment Re -Treat l Slab 5c 1st Treatment Re -Treat Pools 1st Treatment Re -Treat Perimeter for Final Inspection of Exterminator Note.' There must be a completed form for each requIrb Treatment or re -treatment and this form must be on the job site to be picked up by the Inspector at time ofeach Inspection or the scheduled lnspectlon will fall and a re -inspection fee charged. F6c104.2.6 Certlflcate ofProtective TYeatmentforpreventlon oftermites. A weatherresislantjobslte posting board shall be provided to receive duplicate Treatment Certificates as each required protective treatment is completed, providing a copy for the person the permitis Issued to and another copyfor the bullding permit flies The Treatment Cerdflcate shall provide the product used, identity of the appllcato , time and date of the treatment, site location, area treated, chemical used, percent concentratlon and number of gallons used, to establish a verifiable record of protective treatment. If the soil chemical barrier method for termite prevention Is used, final exterior treatment shall be completed pNor to final building approval. St Lucie County requires for the final inspection for CO, a Permanent Sticker to be placed on the electrical panel bolt cover, listing all the treatments and dates of applications. R.YJa.d 7/24/2014