Certification for Design Load Compliance
Project Name: MIS,-uQNh Y VLeirCS — GI.OP4 -hibUSE 1,p,y
Project Address: 41atMMnN 13 kDAD # CT1-1-�1 . 131_V M - �. VLEKL.�, FL_ 34' / T6
Permit #: 1'8 /Z 0 40"Z Occupancy Type: ,e-2 it- (r R 1Lonstruction Type: V B
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition SCANNED
o Any accessory structure requiring a building permit BY
.��Any non-residential structure. St. LUCID' Count
�
• Note: Form not required for interior renovations provided that no exterior structural elements ar affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida Building Code Mfth-Edition with 20 17 Supplements using ASCE 7-10
2. Structure Designed as (check one): XX Enclosed _Partially Enclosed _Open
3. Risk Category: _I XX II _III _ IV Exposure Category: _B _C XX D
4. Design Wind Velocity 170 mph _ASD xx LRFD End Zone Width: 3 ft
S. Mean Roof Height 15 ft Roof Pitch: 6 :12 Parapet: N/A ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings)
Zone 1:+26.4/42.0 Zone 2:
+26.41-73.1 Zone 3: +26.4/-196.1
Zone4:+45.91-19.8 Zone 5:+45.91a1.4 Garage: N/A
7. Design Loads: Floor: NIA
PSF Roof/Dead: 35
PSF Roof/Live:
20_ Balcony: N/A PSF
Dock: N/A PSF Deck:
N/A PSF Stairs: N/A
PSF Fence: NIA
PSF Railings: N/A PSF
B. Were Shear Walls Considered For Structure? xx Yes
_Not Applicable
Explain Why Not:
9. Is A Continuous Load Path Provided? XX Yes _Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? _Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
Allen Wieder FL PE 43444
Signature, Date, and Seal
Revised 07/25/2014
Print Name
Wieder Engineering, Inc
Cert # & Co. Cart Auth.
11718 SE Federal Hwy #373, Hobe Sound, FL 33455
Company Name & Address
La
F
L�&]� ��i
4,
Planning & Development Services Department RECEIVED
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 - (772) 462-15 DEC 0 4 2018
Certification for Design Load Compliance ST. Lucie County, Permitting
Project Name: /7715Sfa n1
Project Address: #1 N '71vJ 00*u 4, C'tm- $wer rT-- / 16- 5-tO7 alp
Permit q:
Type: U Construction Type: V V
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessary structure requiring a building permit
�— Any non-residential structure.
' Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the q above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
04i
1. DESIGN CODE: Florida Building CodeFifth Edition with 20 17 Supplements using ASCE 7-10
2. Structure Designed as (check one): XX Enclosed _Partially Enclosed _Open
3. Risk Category: _I XX II _III IV Exposure Category: _B _C XX D
4. Design Wind Velocity 170 mph _ASD xx LRFD End Zone Width: 3 ft
5. Mean Roof Height 15 ft Roof Pitch: 6 :12 Parapet: N/A ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1:.26.4i42.0 Zone 2: *26.41-73.1 Zone 3: '26'4/-108'1 Zone 4:+45.91-19.a Zone 5:'45.9i-61.4 Garage: N/A
7. Design Loads: Floor: NSA PSF Roof/Dead: 35 PSF Roof/Live: 20 Balcony: WA PSF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A P5F
R. Were Shear Walls Considered For Structure? Xx Yes _Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? XX Yes _Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? _Yes
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
Allen Wieder FL PE 43444
Signature, Date, anii Seal
Print Name
Wieder Engineering, Inc
Cert N & Co. Cert Auth.
11718 SE Federal Hwy #373, Hobe Sound, FL 33455
Company Name & Address
Revised 07/25/2014
()IwTeam
3601-A Crossroads Parkway
Fort Pierce, FL 34945
405423505,405423535
Gale Insulation
BUILDER: Richard K Davis Construction SUBDIVISION:
JOB ADDRESS:3163 Hammond Rd CITY: Fort Pierce
PERMIT#: LOT/BLOCK:
INSULATION INSTALLATION CERTIFICATE
The undersigned hereby certifies that insulation has been installed in the above property as follows:
1. Exterior CBS walls have been insulated with to thickness of inches, which
according to will yield an "R" value of
2. Exterior frame wall has been insulated with to a thickness of inches, which
according to will yield an "R" value of
3. Ceiling Area (flat) has been insulated with Spray Foam to a thickness of 5•5" inches, which
according to BASF will yield an "R" value of 20
4. Ceiling Area (vaulted) has been insulated with to a thickness of inches, which
according to will yield an "R" value of
5. Interior knee walls have been insulated with Spray Foam to a thickness of5.5" inches, which
according to BASF will yield an "R" value of 20
6. Garage common walls adjacent to conditioned living space have been insulated with
to a thickness of inches, which according to will yield an "R" value of
General Contractor/Builder
Signature
Insulation Contractors Signature
License # CGC1512179
THE AFFIANT, Jeremy Theisen IS PERSONALLY KNOWN TO ME. Sworn to and subscribed before me this 29
day of October 20+9
Notary Public, State of Florida a�d2`
:c-SL;ru(nc�idat�n
A.G,S:'UIIxpires
=Iq
Ja:: i3.1p"tl
ny
It}�dR FRrdutdt>,bips_Pd5Ria9z1' N00UPeOs,
GALE INSULATION
Richard K Davis Construction
405423505,405423535
CERTIFICATE OF NO -BURN PLUS XD -INSTALLATION
JOB ADDRESS: 3163 Hammond Rd, Fort Pierce, FL
BUILDING PERMIT#
This letter is to certify that Gale Insulation has installed approximately 9,580 square feet of No -
Burn Plus XD in accordance with the No -Burn Plus XD Manufacturer's Specification. (Roof Area)
INSULATION CC# CGC1512179
GALE INSULATION
CERTIFICATE DATE: 10/29/19
THE AFFIANT, JEREMY T SEN, IS PERSONALLY KNOWN TO ME
Sworn to and subscribed before s �e t is 29 day of October , 2019.
Notary public, State of Florid/a"�'`n -e'l
'•./—°j8*,
il'NWf[i254'IFE7
L
''`€!n29
3601-A CROSSROADS PARICIVAY . FT. PIERCE, FL 34945
FT. PIERCE (772) 465-9191 RIVIERA BEACH (561) 842-1893 MIAMI (305) 625-8397
TOLL FREE (866) 619-8456 a FAX (772) 489-6758
P.fA9 �Fo
Planning & Development Services pen,; 061pp0
Building & Code Regulation Division sE 4!ce�e a
• 2300 Virginia Ave - k e t
• Fort Pierce, FL 34982
772-462-2172 Fax 772-462-6443
CERTIFICATE OF TERMITE TREATMENT
ll�j2-t�c�l2.
CONSTRICTION SAIL TREATMENT
PERMIT #: i� f 2-c�-zi Z 4 JOB ADDRESS: S 16S boo tctloxd QP EEPe.,,,e 3`Ft YC
BUILDER/CONTRACTOR: 4 K �Gk.✓rS
PEST CONTROL CONTRACTOR: EVICT -A -BUG TERMITE & PEST CONTROL INC.
PEST CONTROL LICENSE #: JB175775
We, the undersigned, hereby certify that we have pretreated the above described construction for
subterranean termites in accordance with the standards of the National Pest Control Association.
Square feet if area treated: 145;0 L r
Percentage of solution:.05%
Date of Treatment: d
Footing
1't Treatment
Re -Treat
Driveway
1'` Treatment
Re -Treat
Other
1't Treatment
Re -Treat
Chemicals used: DOMINION 2L
Total gallons used: 179
Time of Treatment: 10 , fly
Slab
1't Treatment
Re -Treat
Pools
1't Treatment
Re -Treat
for Final Inspection
of Exterminator Date
Note. There must be a completed form for eaCA requir€d treatment or re -treatment and this form must be on the job
site to be picked up by the inspector at time of each inspection or the scheduled inspection will fail and a re -inspection
fee charged.
FBC104.2.6 Certificate of Protective Treatment for prevention of termites A weather resistantjobsite posting board
shall be provided to receive duplicate Treatment Certificates as each required protective treatment is completed,
providing a copy for the person the permit is issued to and another copy for the building permit files. The Treatment
Certificate shall provide the product used, identity of the applicator, time and date of the treatment, site location, area
treated, chemical used, percent concentration and number of gallons used, to establish a verifiable record of
protective treatment. If the soil chemical barrier method for termite prevention is used, final exterior treatment shall
be completed prior to final building approval.
St Lucie County requires for the final inspection for CO, a Permanent Sticker to be placed on
the electrical panel box cover, listing all the treatments and dates of applications.
Revised 7/24/2014
- Termite Inspection
Christ is
_ •I
1 72-323-7921
• Termite Pretreatment
Toll free: 1-811-385-9998
• Pest Control
• Rodent Service
9771P
AM 772-349-5889
• Fire Ant Lawn Service
Email: Evictabug@gmail.com
• Whitefly Treatment
4293 SW High Meadows Ave.
• Licensed & Insured
Lic. J617
Palm City, FL 34990
Notice of Preventative Treatment for Termites
(as required by Florida Building
Code (FBC) 104.2.6, 105.10 & R318.1 and Broward County Chapter FBC 105.2.2)
PEST PREVENTION I FIRE ANT SERVICE I TERMITE SERVICE I RODENT EXCLUSION & REMOVAL I WHITEFLY TREATMENT
DATE OFSERVICE Z
TIME 16 ' C
DEVE//L�1O__P�MENT NAME (PROJECT) CONTjditCTOC�S NAME, � r CONTTAACT PERSON
1.V7. ie: KK ��<C/ 4411��))�`--((..li�� Il✓✓CCl/
STRUCTURE ADDRESS (LOTIBLOCK) CITY, STATE C LINTY
>lcu t C�cA D �T t,� � _ r �.c -Q
NOTES ZIP CO%
❑ FLOATING
❑ MONOLITHIC
❑ PATIO
❑ GARAGE ❑ DRIVEWAY ❑ STEM WALUFOOTERS ❑ ADDITION
❑ CUTOUTS
❑ FOOTER
❑FRONT ENTRY
❑ RETREAT ❑ BORA CARE TREATMENT CIPLUMBING CUTOUTS ElSIDEWALKS
❑ TAMP & TREAT
TREAT ONLY
Jp1FINAL
U
❑ POOL DECK ❑ OTHER
PRODUCTS
tt �/
❑ BASELINE
❑ DOMINION 2LACTIVE
INGREDIENT
❑ TERMIDOR SC ❑ BORACARE ❑ PREMISE ❑ TALSTAR
❑-0THER
IJ
ACTIVE INGREDIENT
0IMIDACLAPRID O BIFENTHRIN ❑ DISODIUM OCTABORATE TETRAHYDRATE
CONCENTRATION
i
12
❑ .06% ❑ .1%
❑ .12% ❑ .25%
�1.05% ❑ 23%
❑ 9% ❑ OTHER GAALLLONSAPPLIED
SQUARE FOOTAGE
LINEAR FOOTAGE 7 <;7(,3�
YES ❑ NO --MEASURED OR VERIFIED PER PLANS
T_�—
YES ❑ NO DETAILS
"Certificate of Compliance"
As per 104.2.6,105.10 & R318.1 FBC - If soil chemical barrier method for termite prevention is used.
Final exterior treatment shall be completed prior to final building approval.
Certificate of Compliance: The building has received a complete treatment for the prevention of subterranean termites. Treatment is in accordance with rules
and laws established by the Florida Department of Agriculture and Consumer Servic s. (Per the Florida Building Code.)
If this notice is for the final exterior treatment, initial and date this line z
JIB. 'S'rli�
FINAL STICKER
❑ ELECTRICAL PANEL ❑ WATER HEATER ❑ OTHER 1A1 if Y�
Payment Terms: Payment due at time of service. A
S 7.0
Date r Applicator. E mlA Bug Termite and Pest Control, Inc.)
Date Customer (Property Owner or Agent)
www.evictabugpestcontrol.com
L15 Christ Is
' ®5 fu1Ct-A-BUg hn r--?
Termite & Lic. JB175775
Pest
Control,
Inc.
Pest Prevention Termite Protection
THIS NOTICE POSTED PURSUANT TO SECTION 104.2.7, FLORIDA
BUILDING CODE AND CHAPTER 482. 6, FLORIDA STATUTES
Date of WDO Inspection (If Made) ❑Evidence ❑Activity ❑No Activity
Date of I ifial T atmant Materials Used
Date of Final Ex nor Treatment Materials Used
Wood Destroying Organism Treated For
This property has been treated and placed under a retreatmenUrepair contract for subterranean
Iemiites. This contract is renewable by payment on annual fee. The owner is hereby advised to
have this Property inspected annually by Evict -A. Bug Termite & Pest Control, Inc
Evict -A- Bug Termite & Pest Control, Inc. provided the termite protection
onthisproperty. CALLUS regarding our Pest Prevention, Fire Ant Lawn
Servim and Rodent Service. / •
772-323-7921 0 1-877-365-9990[&
www.evictabugpestcbntrol.com - evictabug@gmail.com
4293 SW High Meadows Ave. • Palm City, FL 34990
Ca//fa alivaleYourfern/le Guarantee
Planning & Development Services
suliding & Code Regulation Division
2300 Virginia Ave
Fort Plerce, FL 34982
772-462-2172 Fax 772-462-6443
CERT2KCATE OF TERMITE TREATMENT
CONSTRUC7ZON SOIL TREATMENT
PERMIT #: 1811-a'2612 JOB ADDRESS: �2� /d�w,/.av107 QI! ffPiercE 23 5 Y�
BUILDER/CONTRACTOR K 1-JaVrS
PEST CONTROL CONTRACTOR: EVICT•A-BUG TERMITE& PEST CONTROL INC.
PEST CONTROL LICENSE #: JB175775
We, the undersigned, hereby certify that we have pretreated the above described construction for
subterranean termites in accordance with the standards of the National Pest Control Association.
Square feet if area treated: 60?— Chemicals used: DOMINION 22L
Percentage of solution: .05% Total gallons used: k��D
—Date-of Treatment:- O 1 9 _ Time of Treatment:
Footing
Y' 1st Treatment
Re -Treat
Driveway
1st Treatment
Re -Treat
Other
1st Treatment
Re -Treat
l Slab
5c 1st Treatment
Re -Treat
Pools
1st Treatment
Re -Treat
Perimeter for Final Inspection
of Exterminator
Note.' There must be a completed form for each requIrb Treatment or re -treatment and this form must be on the job
site to be picked up by the Inspector at time ofeach Inspection or the scheduled lnspectlon will fall and a re -inspection
fee charged.
F6c104.2.6 Certlflcate ofProtective TYeatmentforpreventlon oftermites. A weatherresislantjobslte posting board
shall be provided to receive duplicate Treatment Certificates as each required protective treatment is completed,
providing a copy for the person the permitis Issued to and another copyfor the bullding permit flies The Treatment
Cerdflcate shall provide the product used, identity of the appllcato , time and date of the treatment, site location, area
treated, chemical used, percent concentratlon and number of gallons used, to establish a verifiable record of
protective treatment. If the soil chemical barrier method for termite prevention Is used, final exterior treatment shall
be completed pNor to final building approval.
St Lucie County requires for the final inspection for CO, a Permanent Sticker to be placed on
the electrical panel bolt cover, listing all the treatments and dates of applications.
R.YJa.d 7/24/2014