HomeMy WebLinkAboutMISCFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: SEDONA DEVELOPMENT Bldg 9 Builder Name: Street:. 3128-3138 MORNING DEW LANE PenMt Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number..1807-0810 Owner. Design Location: FL, Fort Pierce Jurisdiction: 6 County: St. Lucie (Florida Climate Zone 2 ) 1. New;construction or existing New (From Plans) 9. Wall Types(6420.0 sgft.) Insulation Area 2. Single family or multiple family Multi-famlly a. Concrete Block - Int lnsul, E#erior R=4.1 6420.00 ft2 3. Number of units, if multiple multiple family g N/A R- ft2 4. Number of Bedrooms 12 c. WA d. N/A R= ft2 5. Is this a worst case? N0 10. Calling Types (4046.0 sgfL) R= ft2 Insulation Area I 6. Conditioned floor area above grade (ft2) 4044 a. Under Attic (Vented) b. WA R=30.0 4046.00 ft2 R- ft2 Conditioned floor area below grade (ft2) 0 c. WA R= ft2 Win ows(390.0 sqft.) Description ptien Area 11. Ducts 3 additional duct system(s) R ft27. 6 135 a. WFactor. Dbl, U=0.65 240.00 ft2 b. Sup: Attic, Rat: Attic, AH: UNIT 1 6 135 SHGC: SHGC-0.26 c. Sup: Attic, Rat Attic, AH: UNIT 1 (see detail b. U Factor. Dbl, U=0.60 160.00 fill 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 c. U-Factor. N/A a. Central Unit b. Central Unit 18.8 SEER:16.00 18.8 SEER:16.00 ft2 SHGC: 3 additional cooling systems (see details) d. U,Factor. WA 13. Heating systems kBtu/hr Efficiency f2 SHGC: a. Electric Strip Heat 17.0 COP:1.00 b. Electric Strip Heat 17.0 COPA.00 Area,Weighted Average Overhang Depth: 1.000 ft. 3 additional heating systems (see details) Areal Weighted Average SHGC: 0.250 14. Hot water systems S. Floor Types (4044.0 sgfL) Insulation Area a. Electric Cap: 40 gallons a. Slab-0n-Grade Edge Insulation R-0.0 4044.00 ft2 b. Conservation features EF: 0.950 b. WA' R-ft2 None a WA . R_ ft2 15. Credits CF, Pstat Glass/FloorArea: 0.096 Total Proposed Modified Loads: 148.80 PASS Total Baseline Loads: 157.99 i I hereby certify that the plans and specifications covered by Review of the plans and STq?8 this calculation are in compliance with the Florida Energy specifications covered by this D�TliB pA Code. calculation indicates compliance ue_ p, with the Florida Energy Code. rnrrr,: x. "'°•' r, PREPAR D Y' Before construction is completed , DATE:; this building will be inspected for I,` All, compliance with Section 563.908 * tr I hereby certify that this btdidesIgned,lainoomplianoe, with the Florida Energy Florida Statutes. �CDD 14B t¢�� OWNETAGEN DATE:; BUILDING OFFICIAL: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed In accordance with R403.3.2.1. compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402A.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). BY St. Lucie County 1/3/201910:34 AM EnergyGauge® USA Section R405.4.1 Compliant Software File C®1117� page 1 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: SEDONA DEVELOPMENT B Bunding Type: User Bedrooms: 12 Address Type: Street Address Conditioned Area: 4044 Lot # Owner' Name: Total Stories: 1 Block/Subdivision: # of Units: 6 Worst Case: No PlatBook: BuildaF Name: Rotate Angie: 0 Street: 3128-3138 MORNING Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lurie Jurisdiction: 6 Family Type: Multi Whole House Fan: No City, State, 21p: Fr. PIERCE, -family FL, New/Existng: New (From Plans) Comment: i CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL; Fort Pierce FL bERO—BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Nurritier Name Area Volume I 1 Blockt 668 i 6880 2 Block2 687 6670 3 Block3 667 6670 4 Block4 1334 13340 i 5 Blocks 688 6880 SPACES Number Name Area Volume K@chen Occupants Bedrooms In81ID Finished Cooled Heated 1 UNIT 1 688 6880 Yes 2 2 1 Yes Yes Yes 2 UNIT 2 667 6670 No 2 2 1 Yes Yes Yes 3 UNIT 3 667 6670 No 2 2 1 Yes Yes Yes 4 UNIT 4 AND 5 1334 13340 No 2 4 1 Yes Yes Yes 5 UNIT 688 6880 No 2 2 1 Yes Yes Yes FLOORS ' # FloorType Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet _I 1 Slab -On -Grade Edge Insula8o UNIT 1 125 ft 0 688 ft' _ 1 0 0 _ 2Slab-On-GredeEdge Insulatio UNIT 125 It 0 667fF — 0 0 1 3 Slab -On -Grade Edge Insulatio UNIT 3 125 It 0 667 ft' a_ 1 0 0 4SIab-On-Grade Edge Insulato UNIT 4 AND 5 250 ft 0 1334 ft2 _ 1 0 0 5 Slab -On -Grade Edge Insulatio i UNITS 125 ft 0 688 ft2 — 1 0 0 t/3/20!19 1o:34 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: SEDONA DEVELOPMENT B Bedrooms: 12 Address Type: Street Address Buildipq Type: User Conditioned Area: 4044 Lot # Owner Name: Total Stories: 1 # units: Block/Subdivislon: of 1 Worst Case: No Builde1.r Name: PlatBook: Rotate Angle: 0 Street 31283138 MORNING PermitOffice: ST. LUCIE COUNTY Cross Ventilation: No County: St Lucie Jurisdiction: a Whole House Fan: No Family Type: Multi -family City, State, Zip: Ff. PIERCE, FL, NewlEdsting: New (From Plans) Comment: CLIMATE Design Tamp Int Design Temp Heating Design Dally Temp v Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VER0 BEACHJWUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 688 6880 2 Block2 667 6670 3 Block3 667 6670 4 Block4 1334 13340 5 Blook5 688 6880 SPACES Numtier Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated) 1 UNIT 1 688 6880 Yes 2 2 1 Yes Yes Yes 2 UNIT2 667 6670 No 2 2 1 Yes Yes Yes 3 UNIT 3 667 6670 No 2 2 1 Yes Yes Yes 4 UNIT 4AND 5 1334 13340 No 2 4 1 Yes Yes Yes 5 UNIT 688 6880 No 2 2 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter PedmeterR-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio UNIT 1 125 ft 0 688 ft' 1 0 0 2SIab-On-Grade Edge Insulatio UNIT 2 125 ft 0 667 fN _ 0 0 1 3 Slab -On -Grade Edge Insulatio UNIT 3 125 ft 0 667 ft' _ 1 0 0 4 Slab -On -Grade Edge Insulatio UNIT 4 AND 5 260 It 0 1334 f12 1 0 0 5SIab-On-Grade Edge Insulatio UNITS 125 ft 0 688 ft' _ 1 0 0 1/3/201810:34 AM EnergyGaugeO USA Section R406.4.1 Compliant Software Page 2 of 6 FORM R405-2017 INPUT RI IMMADV C14Mr% I ICT 000noT ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Matedals Area Area Color Absor. Tested Tested Insul. (deg) i 1 Gable or shed Composition shingles 4380IF 842 ft' Light 0.61 No 0.9 No 0 22.6 ATTIC / V # Type Ven0la0on Vent Rego (1 In) Area RBS IRCC 1 Full attic Vented 300 40" ft' N N CEILING # Calling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 UnderAttic (Vented) UNIT 1 30 Blown 688 fE 0.11 Wood 2 Under Attic (Vented) UNIT 1 30 Blown 668 ft' 0.11 Wood 3 Under Attic (Vented) UNIT 1 30 Blown 668 fF 0.11 Wood 4 Under Attic (Vented) UNIT 1 30 Blown 1334 f' 0.11 Wood 5 Under Attie (Vented) UNIT 1 30 Blown 688 fE 0.11 Wood WALLS Adjacent To iAfa11:Pq)n Space Cavily Width Height Sheathing Faming Solar Below 1 N Exterior Concrete Block - Int Insul UNIT 1 - 4.1 16 10 160.0 ft 0 0 0.5 o 0 2 E Exterior Concrete Block - Int Insul UNIT 1 4.1 45 10 460.0 fE 0 0 0.6 0 3 S Exterior Concrete Block - Int Insul UNIT 1 4.1 16 10 160.0 ft' 0 0 0.5 0 -4, W Exterior Concrete Block- Int Insul UNIT 1 4.1 45 10 450.0 IF 0 0 0.6 0 5 I N Exterior Concrete Block - Int Insul UNIT 2 4.1 18 10 160.0 fE 0 0 0.5 0 _6! E Exterior Concrete Block - Int Insul UNIT 2 4.1 45 10 450.0 fE 0 0 0.5 0 7 j S Exterior Concrete Block - Int Insul UNIT 2 4.1 16 10 160.0 fE 0 0 0.6 0 _ 8 E Exterior Concrete Block - Int Insul UNIT 2 4.1 45 10 450.0 fF 0 0 0.5 0 _ 9 N Exterior Concrete Block- Int Insul UNIT 3 4.1 16 10 160.0 ft' 0 0 0.5 0 _1011 E Exterior Concrete Black- Int Insul UNIT 3 4.1 45 10 450.0 f 2 0 0 0.5 0 _11 S Exterior ConcreteBlock- Intlnsul UNIT 4.1 16 10 160.01E 0 0 0.5 0 _12' W Exterior Concrete Block- Int Insul UNIT 3 4.1 45 10 450.0 fF 0 0 0.5 0 _13� N Exterior Concrete Block -Int lnsWNIT4 AND 4.1 32 10 320.0IF 0 0 0.5 0 _14', E Exterior Concrete Block 4.1 45 10 450.0f 2 0 0 0.5 0 151 S Exterior Concrete Block - Int InsWNIT 4 AND 4.1 32 10 320.0 fF 0 0 0.5 0 _16; W Exterior Concrete Block - Int lnsWN1T4 AND 4.1 45 10 450.0fF 0 0 0.5 0 _ 17 ! N Exterior Concrete Block - Int Insul UNIT 6 4.1 16 10 160.0 fF 0 0.5 0 E Exterior ConcreteBlock- Intlnsul UNITS 4.1 45 10 450.01E 0 0.5 0 _19i S Exterior ConcreteBlock- Intlnsul UNIT 4.1 16 10 160.0 IF 0 0.5 0 _201 W Exterior Concrete Block - Int Insul UNIT 6 4.1 45 10 450.0 fE 0 0.5 0 10201910:34 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DOORS # Omt Door Type Space Storms U Value Width Height Area Ft In Ft In 1 N Insulated UNIT 1 None .37 3 6 8 20 fix 2 N Insulated UNIT 2 None .37 3 6 8 20 fl 3 S Insulated UNIT None .37 3 6 8 20 IV -� 4 W Insulated UNIT 4 AND None. .37 3 6 8 20 ft2 5 W Insulated UNIT 4 AND None .37 3 6 a 20 ft2 6 S Insulated UNIT None .37 3 6 8 20 ft2 WINDOWS Orientation shown Is the entered Proposed orientation. Wall Overhang V �# Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 i N 1 Vinyl Low-E Double Yes 0.65 0.25 N 40.0 IV 1 It 0 in 1 It 4 in Drapes/blinds None 2 S 3 Vinyl Low-E Double Yes 0.6 0.25 N 20.0 ft2 1 It 0 In 1 It 4 in Drapes/blinds None 3 W 4 Vinyl Low-E Double Yes 0.6 0.25 N 15.0 ft2 1 It 0 in 1 ft 4 in Drapes/blinds None .4 N 5 Vinyl Low-E Double Yes 0.65 0.26 N 40.0 11:2 1 ft 01n 1 ft 41n Drapes/bllnds None 5 S 7 Vinyl Low-E Double Yes 0.6 0.25 N 20.0 ft2 1 It 0 in 1 ft41n Drapesiblinds None :6 N 9 Vinyl Low-E Double Yes 0.65 0.25 N 40.0 ft2 1 It 0 in 1 It 4 in Drapeslblinds None 7 S 11 Vinyl Low-E Double Yes 0.6 0.25 N 20.0 112 1 ft 0 in 1 ft4 in Drapes/blinds None 8 N 13 Vinyl Low-E Double Yes 0.65 0.25 N 80.0 ft2 1 It 0In 1 ft 4 in Drapes/blinds None 9 S 15 Vinyl Low-E Double Yes 0.6 0.25 N 40.0 ft2 1 ft 0 in 1 ft 4 In Drapea/bllnds None 10 N 17 Vinyl Low-E Double Yes 0.65 0.25 N 40.0 ft2 1 It 0 in 1 ft 4 in Drapestblinds None 41 E 18 Vinyl Low-E Double Yes 0.6 0.25 N 15.0 ft2 1 ft 0 in 1 It 4In Drapes/blinds None 12 S 19 Vinyl Low-E Double Yes 0.6 0.25 N 20.01N 1 ft 0 in 1 it 41n Drapes/blinds None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 WhI'olehouse Proposed ACH(50) .000445 4718 259.01 487.11 .3446 7 i HEATING SYSTEM # System Type SubWa Ef ldency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 17 kBtu/hr 1 sys#1 2 Electric Strip Heat/ None COPA 17 kBtulhr 2 sys#2 3 Electric Strip Heat/ None COPA 17 kBtu/hr 3 sys#3 5 Electric Strip Heat/ None COPA 17 kBtulhr 5 sys#5 4A Electric Strip Heat/ None COPA 17 kBtu/hr 4 sys#4 4 B Electric Strip Heat/ None COPA 17 kBtu/hr 4 sys#4 1/3/201910:34 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2017 INPUT Cl IMIIIIAIRV rtUmmel io-r oeonoT COOLING SYSTEM # System Type Subtype Efficiency Capacity AIr Flow SHR Block Ducts 1 Central Unit/ None SEER: 16 18.8 kBtu/hr 564 cfm 0.8 1 sys#1 _I 2 Central Unit/ None SEER: 16 18.8 kBtu/hr 664 cfm 0.8 2 sys#2 3 Central Unit/ None SEER: 16 18.8 kBtu/hr 564 ofm 0.8 3 sys#3 5 Central Unit/ None SEER: 16 18.8 kBtu/hr 664 ofm 0.8 5 sys#5 _. 4A Central Unit/ None SEER: 16 18.8 kBtufhr 564 dm 0.8 4 sys#4 4 B Central Unit/ None SEER: 16 18.8 kBtuthr 584 afro 0.8 4 sys#4 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation _I 1 Electric None UNIT 1 0.95 40 gal 130 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart# Company Name System Model# Collector Model# Area Volume FEF I None None fF !` DUCTS / V — Supply — — Return — Air CFM 25 OFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 135 ft' Attic 35 fF Default Leakage UNIT 1 (Default) (Default) 1 1 2 Attic 6 135 fN Attic 35 fF Default Leakage UNIT 1 (Default) (Default) 2 2 3 Attic 6 136 ft' Attic 35IF Default Leakage UNIT 1 (Default) (Default) 3 3 4 Attic 6 260 ft' Attic 65 ft' Default Leakage UNIT 1 (Default) (Default) 4 4 6 Attic 6 135 tF Attic 35 ft Default Leakage UNIT 1 (Default) (Default) 5 5 I TEMPERATURES Progremable Thermostat Y Coiling Fans: Cooling Venting Jan Feb Jan Feb [D0� Mar Mar Apr May Jun Jul Aug f[X�t Sep r Oct € May Jun Jul W Oct r00' Nov Nov[l rD0' Dec [X] AAppr Aug [ ] Sep ]( Nov [ ] Dec 1/3/201910:34 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST RFPART Thennostet Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling i(WD) 80 80 78 78 78 PM 78 78 78 78 78 78 78 Cooling (WEH) 78 78 PM 78 78 78 78 78 78 78 78 78 78 Heating,(WD) AM 66 66 66 66 66 68 68 Be 68 68 68 68 PM Be 68 68 68 68 68 Be 68 68 6s 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 Be as 68 Be 68 PM 68 68 68 6s 68 Be 68 68 68 68 66 66 MASS Was Type Area Thickness Furniture Fraction Spars Defeult(8 Ibs/sq.ft. 0 ft' 0 ft 0.3 UNIT 1 Default(8 Ibs/sq.ft. 0 fP Oft 0.3 UNIT 2 6efault(8 Ibs/sq.ft. 0 ft' 0 ft 0.3 UNIT 3 6efault(8 Ibs/sq.ft. Oft 0 It 0.3 UNIT 4 AND 5 Default 8 Ibs/ .ft 0 ftz O ft 0.3 UNIT 6 Name: Test Rater Rating Compant: Test Rater 1/3/2019 10:34 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: SEDONA DEVELOPMENT Bldg 8 Builder Name: Street: 3128-3138 MORNING DEW LANE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number.,1807-0810 Owner. Jurisdiction: 6 Design Location: FL, Fort Pierce = U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceilirxg/attic The air barrier in any dropped calling/soffit shall be aligned with the insulation and any gaps In the air barrier shall be sealed. The insulation in any dropped cailffd Access openings, drop down stairs or knee wall doors to shall be aligned with the air barrier. unconditioned attic spaces shall be sealed. The junction of the foundation and sill plate shall be sealed. walls Cavities within comers and headers of frame walls The junction of the top plate and the top of Wader walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee wails shall be sealed. per Inch minimum. Exterior thermal envelope Insulation for framed walls shall be Installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors I skylights and framing shall be sealed. Rim joists Rim joists shall Include the air barrier. Rim joists shall be insulated. Floor's, The air barrier shall be Installed at any exposed edge of Floor framing cavity Insulation shall be Installed to (including abovkarage Insulation. maintain permanent contact with the underside of end cAdlevered subfloor decking, or floor framing cavity Insulation floors) � shall be permitted to be in contact with the top aide of sheathing, or continuous Insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crewl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided Instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace, Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. i i Hens In narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on Installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac 3s. Recessed lighting Recessed light fixtures installed In the building thermal envelope Recessed light fixtures Installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt Insulation shall be cut neatly to fit around wiring and plumbing In exterior walls, or insulation that on Installation readily conforms to available space shall behind ninIng nnrl Wring Exterior walls adjacent to showers and tubs shall Shower/tub on exterior The air barrier Installed at exterior walls adjacent to showers and wall tubs shall separate them from the showers and tubs. be Insulated. Eleck yphcne box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be Installed. HVACiegister boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed In a manner that Is recommended by tha manufacturer. Caulking or other adhesive sealants shall not be used to fill voids n Ann ,..ova aw..0 r.. �...___..____ #99 .._ "`."___ _. __ --- a. In addkinn_ Innnanr nn I 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 94 The lower the Energy Performance Index, the more efficient the home. ,I New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level 2. Single-family or multiple -family 2. Multi -family a) Supply ducts R b) Return ducts R 6.0 6.0 3; No. of units (if multiple -family) 3. 6 c) AHU location Attic/Attic 4. Number of bedrooms 4. 12 13. Cooling system: Capacity 112.8 a) Split system SEER 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEERICOP 6: Conditioned floor area (sq. ff.) 6. 40" d) Room unit/PTAC EER 7. Windows, type and area e) Other 16.0 a) U-fecton(weighted average) 7a. 0.631 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 14. Heating system: Capacity 102.0 c) Area 7c. 390.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor.(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE 0 Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) ga. 0.0 b) Wood, raised (R-value) gb. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.95 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans Yes a)Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. Yes e) Muifizone heating credit f) Programmable thermostat Yes "Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded"his his home before final inspection. Otherwise, a new EPL display card will be completed bas d o lied compliant features. Builder Signature: Date: I Ig Address of New Home: City/FLZip: FT. PIERCE FL 1/3/20,19 10:34:65 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1