Loading...
HomeMy WebLinkAboutFLORIDA ENERGY EFFIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: SEDONA DEVELOPMENT Bldg 10 Builder Name: Street: 3142-3152 MORNING DEW LANE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number:1807-0810 Owner. Jurisdiction: Design Locaflon: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New'cOnstruction or existing New (From Plans) 9. Wall Types(6420.0 sqft.) Insulation Area 2. Single family or multiple family Multi -family a. Concrete Block - Int Insul, Exterior R=4.1 6420.00 ft2 3. Number of units, if multiple family g b. N/A R= ft2 4. Number of Bedrooms 12 c. WA d. N/A R= ft2 R= ft2 5. Is this a worst case? No 10. Calling Types (4046.0 sgft.) Insulation Area 6. Condltioned floor area above grade (ft2) 4044 a. Under Attic (Vented) b. WA R=30.0 4046.001N R= ft= Conditioned floor area below grade (fo 0 c. N/A R= ft2 7. Windows(390.0 sgft.) Description Area 113 additional duct system(s) R ft2 6 135 a. U-Factor. Dbl, U=0.65 240.00 fN b. Sup: Attic, Ret: Attic, AH: UNIT 1 6 135 SHGC: SHGC=0.25 c. Sup: Attic, Ret: Attic, AH: UNIT 1 (see detail b. U-Factor. Dbl, U=0.60 150.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 18.8 SEER:16.00 c. U-Factor. N/A ftz b. Central Unit 18.8 SEERA6.00 SH9C: 3 additional cooling systems (see details) d. U-Factor. WA ft2 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Strip Heat 1T.0 COP:1.00 b. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 1.000 ft. 3 additional heating systems (see details) Area Weighted Average SHGC: 0.260 14. Hot water systems S. Floor Types (4044.0 sgft.) Insulation Area a. Electric Cap: 40 gallons a. Slab, On -Grade Edge Insulation R=0.0 4044.00 ft2 b. Conservation features EF: 0.950 b. WA, R= ft2 c. N/A None R= ft2 15. Credits CF, Pstat Glass/FloorArea: 0.096 Total Proposed Modified Loads: 151.79 PASS Total Baseline Loads: 157.99 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Review of the plans and �Q41iB Sr4?6 Code. specifications covered by this y p� calculation Indicates compliance u with the Florida Energy Code. f� nsr;. •• pp f aN PREPAR D B : DATE: • Before construction is completed this building will be inspected for t Id' " A compliance with Section 553.908 I hereby certify that t s b g, as designed, is in compliance Florida Statutes. with the Florida En y C e.WMIS OWNEW/AGENT BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factorysealed In accordance with R403.3.2.1. Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). SCANNED BY St. Lucie County He CmpY 1131201910:36 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPnRT PROJECT Tide: SEDONA DEVELOPMENT B Bedrooms: 12 Address Typo: Street Address BuildinglType: User Conditioned Area: 40" Lot# Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 6 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 3142-3152 MORNING Permit Office: ST. LUCIE COUNTY Crass Ventilation: No County: St. Lucie JurisdiclJon: Whole House Fan: No City, State, Zip: FT. PIERCE, Family type: Muid-family FL, ' Now/Existing: New (From Plans) Comment CLIMATE . / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.6 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH,JVIUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 668 6880 2 Block2 667 6670 3 Blodr3 667 6670 4 Block4 1334 13340 5 Block5 688 6880 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 UNIT 1 688 6880 Yes 2 2 1 Yes Yes Yes 2 UNIT 2 667 6670 No 2 2 1 Yes Yes Yes 3 UNIT 667 6670 No 2 2 1 Yes Yes Yes 4 UNIT AND 5 1334 13340 No 2 4 1 Yes Yes Yes 5 UNIT 688 6880 No 2 2 1 Yes Yes Yes FLOORS # Floor Type Spars Perimeter PadmeterR-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio UNIT 1 126 ft 0 688 fN — 1 0 0 2Slab-On-Grade Edge Insulatio UNIT2 125 It 0 667 fl — 0 0 1 3 Slab -On -Grade Edge Insulatio UNIT 3 125 ft 0 667 ft' 1 0 0 4SIab-On-Grade Edge Insulatio UNIT 4 AND 5 250 ft 0 1334 11 __- 1 0 0 5Slab-On-Grade Edge Insulatio UNIT 6 125 It 0 688 fN 1 0 0 113/201910:36 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed Composition shingles 4380 ft2 842112 Ught 0.6 No 0.9 No 0 22.6 ATTIC / V e # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 4044 f12 N N CEILING # Ceiling Type Space R Value Ins Type Area Framing Frac Truss Type _ 1 Under Attic (Vented) UNIT 30 Blown 688ft2 0.11 Wood _ 2 Under Attic (Vented) UNIT 1 30 Blown 668 ft2 0.11 Wood _ 3 Under Attic (Vented) UNIT 1 30 Blown 668 ft2 0.11 Wood _ 4 Under Attic (Vented) UNIT 1 30 Blown 1334 ft2 0.11 Wood 5 Under Attic (Vented) UNIT 1 30 Blown 688 ft2 0.11 Wood WALLS ' Adjacent Spate Cavity Width Height Sheathing Framing Solar Below R-NLRI..e Ft In Et In Aran R.%Lql,-e Emotion _ 1 N Exterior Concrete Block - Int Insul UNIT 1 4.1 16 10 160.0 ft2 0 0 0.5 0 -2 E Exterior Concrete Block- Int Insul UNIT 1 4.1 45 10 460.0 ft2 0 0 0.5 0 3 S Exterior Concrete Block - Int Insul UNIT 1 4.1 16 10 160.0 ft2 0 0 0.5 0 -4 W Exterior Concrete Block - Int Insul UNIT 1 4.1 45 10 450.0 fix 0 0 0.5 0 _ 5 N Exterior Concrete Block - Int Insul UNIT 2 4.1 16 10 160.0 ill 0 0 0.5 0 6 E Exterior Concrete Block - Int Insul UNIT 2 4.1 45 10 460.0 ft2 0 0 0.5 0 _7 S Exterior ConcreteBlock- Intlnsul UNIT 4.1 16 10 160.0 ft2 0 0 0.5 0 _ 8 E Exterior Concrete Block- Int Insul UNIT 2 4.1 45 10 450.0 ft2 0 0 0.5 0 _ 9 N Exterior Concrete Block - Int Insul UNIT 3 4.1 16 10 160.0 ft2 0 0 0.5 0 10 E Exterior 'Concrete Block - Int Insul UNIT 3 4.1 45 10 450.0 ft2 0 0 0.5 0 _ 11 S Exterior Concrete Block - Int Insul UNIT 3 4.1 16 10 160.0 ft2 0 0 0.5 0 _ 12 W Exterior Concrete Block - Int Insul UNIT 3 4.1 45 10 450.0 f12 0 0 0.5 0 _ 13 N Exterior Concrete Block - Int InsWNIT 4 AND 4.1 32 10 320.0 ft2 0 0 0.5 0 _ 14 E Exterior Concrete Block - Int InsWNIT 4 AND 4.1 45 10 450.0 IF 0 0 0.5 0 _ 15 S Exterior Concrete Block - Int InsWNIT 4 AND 4A 32 10 320.0 fN 0 0 0.5 0 _16 W Exterior Concrete Block- Int InsWNIT 4 AND 4.1 45 10 450.0 fP 0 0 0.5 0 17 N Exterior Concrete Block - Int Insul UNIT 6 4.1 16 10 160.0 ft2 0 0.5 0 _18 ' E Exterior Concrete Block - Int Insul UNIT 6 4.1 45 10 450.0 ft2 0 0.6 0 _ 19 S Exterior Concrete Block - Int Insul UNIT 6 4.1 16 10 160.0 fP 0 0.5 0 20 W Exterior Concrete Block - Int Insul UNIT 6 4.1 45 10 450.0 112 0 0.5 0 113/201910:36 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In _ 1 N Insulated UNIT 1 None .37 3 6 8 20 ft2 _ 2 N Insulated UNIT None .37 3 6 8 20 ft2 3 S Insulated UNIT 3 None .37 3 6 8 20 ft2 _ 4 W Insulated UNIT 4 AND None .37 3 6 8 20 ft2 _ 5 W Insulated UNIT 4AND None .37 3 6 8 20 ft2 6 S Insulated UNIT None .37 3 6 8 20 IF WINDOWS Orientation shown is the entered Proposed orientation. Wall Overhang V .# Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Double Yes 0.65 0.26 N 40.0 ft2 1 ft 0 in 1 ft 41n Drapes/blinds None 2 S 3 Vinyl Low-E Double Yes 0.6 0.25 N 20.0 ft2 1 ft 0 In 1 ft 4 in Drapeslblinds None 3 W 4 Vinyl Low-E Double Yes 0.6 0.25 N 15.0 ft2 1 It 0 in 1 ft 4 in Drapeslblinds None �4 N 5 Vinyl Low-E Double Yes 0.65 0.25 N 40.0 f11 ft 0 in 1 It 41n Drapes/blinds None z S 7 Vinyl Low-E Double Yes 0.6 0.25 N 20.0 112 1 ft 0 in 1 ft 4 In Drapes/blinds None 6 N 9 Vinyl Law-E Double Yes 0.65 0.25 N 40.0 ft2 1 ft 0 in 1 ft 4 in Drapeslblinds None _ 7 S 11 Vinyl Low-E Double Yes 0.6 0.25 N 20.0 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds None 8 N 13 Vinyl Low-E Double Yes 0.65 0.26 N 80.0 ft2 1 It 0 in 1 ft 4 in Drapes/blinds None .9 S 15 Vinyl Low-E Double Yes 0.6 0.25 N 40.0 fF 1 ft 0 in 1 ft 4 in Drapeslblinds Nona _ 10 N 17 Vinyl Low-E Double Yes 0.65 0.25 N 40.0 ft2 1 ft 0 in 1 It 4 in Drapes/blinds None _ 11 E 18 Vinyl Low-E Double Yes 0.6 0.25 N 16.0 ft2 1 It 0 in 1 It 4 In Drapeslblinds None _ 12 S 19 Vinyl Low-E Double Yes 0.6 0.25 N 20.0 ft2 1 It 0 In 1 It 4 in Drapeslblinds None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000445 4718 259.01 487.11 .3446 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Neat/ None COPA 17 kBtu/hr 1 sys#1 2 Electric Strip Heat/ None COPA 17 kBtulhr 2 sys#2 3 Electric Strip HeaU None COP:1 17 kBtu/hr 3 sysW 5 Electric Strip HeaU None COPA 17 kStu/hr 5 sys#5 4 A Electric Strip Heat/ None COPA 17 kBtu/hr 4 sys#4 4 B Electric Strip Heat/ None COP:1 17 kBtulhr 4 sys#4 1/3/2019 10:36 AM EnergyGauge® USA Section R406.4.1 Compliant Software Page 4 of 6 FORM R405-2017 INPI IT RI IMMADV f%MrrVI ICT 000nOT COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ None SEER: 16 18.8 kBtulhr 564 ofm 0.8 1 sys#1 2 Central Unit/ None SEER: 16 18.8 kBtulhr 554 cfm 0.8 2 sys#2 3 Central Unit/ None SEER: 16 18.8 k8tulhr S64 cfm 0.8 3 sys#3 5 Central Unit/ None SEER: 16 18.8 kBtulhr 564 oft 0.8 6 sy8#6 4A Central Unit/ None SEER: IS 18.8 kBtumr 564 arm 0.8 4 sys#4 48 Central Unit/ None SEER: 16 18.8 kBtulhr 564 dm 0.8 4 sys#4 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None UNIT 1 0.95 40 gal 130 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None IF DUCTS Supply -- — Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool . 1 Attic 6 135 fP Attic 35 ft' Default Leakage UNIT 1 (Default) (Default) 1 1 2 Attic 6 136 IF Attic 35 IF Default Leakage UNIT 1 (Default) (Default) 2 2 3 Attic 6 135 f12 Attic 35 IF Default Leakage UNIT 1 (Default) (Default) 3 3 4 Attic 6 260 IF Attic 65 fi' Default Leakage UNIT 1 (Default) (Default) 4 4 5 Attic 6 135 ft' Attic 35 ft' Default Leakage UNIT 1 (Defauft) (Default) 5 5 TEMPERATURES Programabl[eThermostat [Re'nting Cralling Fans: , p(1 ,]Y Jan Feb x Mar ( p' [ D0 [X] [X] May [ ] Jun [ ] Jul [ ] Aug [X] [ ] [ ] Sep L J Oct Nov rD0' Vealing II II Jan t I Feb I l X Mar I f 1 Jun [ ] Jul [ ] Aug t ] Sep lxJ f Nov [ ]Dec 1/3/2019 10:36 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 6 FORM R405-2017 IMP"T SIIIVINIORV [:WPf 1eI ICT oGonoT Thermostat Schedule: HERS 2006 Reference Hours Schedule, ypa 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM PM 66 66 66 66 66 68 68 68 fib 88 68 68 68 68 68 68 68 68 68, 68 6s as 66 66 Hea0ng(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 66 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Defauit(8 Ibs/sq.ft. 0 ft' 0 ft 0.3 UNIT 1 Default(8 Ibs/sq.ft. Oft 0 ft 0.3 UNIT 2 Default(8 Ibs/sq.ft. 0 fta 0 ft 0.3 UNIT 3 Defaalt(s Ibs/sq.ft. 0 ft' O ft 0.3 UNIT 4 AND 5 Default 8 Iba/s .ft. 0 fta Oft 0.3 UNIT 6 Name: Test Rater Rating Compant: Test Rater Date: LA-rl I'( ffi J 1/3/201910:38 AM EnergyGeuge® USA Section R405.4.1 Compliant Software Page 6 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: SEDONA DEVELOPMENT Bldg 10 Builder Name: Street: 31423152 MORNING DEW LANE Permit Office: ST. LUCIE COUNTY City; State, zip: FT. PIERCE, FL, Permit Number..1807-0810 Owner. Jurisdiction: w X Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be Installed in the building envelope. Alr-permeable insulation shall requirements The exterior thermal envelope contains a contnuous air barrier. not be used as a sealing material. Breaks or joints In the air barrier shall be sealed. Celling(attic The air barrier in any dropped calling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comer; and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope Insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall Include the air barrier. Rim joists shall be insulated. Floor;' The air barrier shall be Installed at any exposed edge of Floor framing cavity Insulation shall be Installed to (Including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be In contact with the top side floors) of sheathing, or continuous insulation Installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth In unvented crawl spaces shall be covered with Where provided Instead of floor insulation, Insulation a Class I vapor retarder with overlapping Joints taped. shall be permanently attached to the crawlspace Shafts] penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Bars in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on Installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures Installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt Insulation shell be cut neatly to fit around wiring and plumbing In exterior walls, or Insulation that on Installation readily conforms to available space shall Showeiltub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be Insulated. Electrlca"'one box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be Installed. HVAb lregister boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed In a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids „ uoyewm i e, wa wauv anaii ue in 9CAOreanw wan me provisions or rlA3-4uu. 1/3/2019 10:36 AM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: SEDONA DEVELOPMENT Bldg 10 Builder Name: Street: 3142-3152 MORNING DEW LANE Permit Office: ST. LUCIE COUNTY City; State, Zip: FT. PIERCE, FL, Permit Number..1807-0810 Cyr Owner. Jurisdiction: m Desjgn Location: FL, Fort Pierce X COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shell be installed in the building envelope. Air -permeable Insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks arjoints in the air barrier shall be sealed. Cetling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation In any dropped ceiling/aoffit the insulation and any gaps in the air barrier shall be sealed. shell be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per Inch minimum. Exterior thermal envelope Insulation for framed walls shall be Installed In substantial contact and continuous alignment with the air baffler. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim Joists shall include the air barrier. Rim joists shall be Insulated. Floors The air barrier shall be Installed at any exposed edge of Floor framing cavity Insulation shall be Installed to (including insulation. maintain permanent contact with the underside of above -garage subfloar docking, or floor framing cavity Insulation and cantilevered shall be permitted to be In contact with the top side floors) of sheathing, or continuous insulation Installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided Instead of floor Insulation, Insulation a Class I vapor retarder with overlapping Joints taped. shall be permanently attached to the crewlspace Shafts; penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall he sealed. ' Batts In narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on Installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac is. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed In the building • shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt Insulation shall be cut heady to fit around wiring and plumbing In exterior walls, or insulation that on Installation readily conforms to available space shall extend behind piping and wiring, Exterior walls adjacent to showers and tubs shall ShoweOub The air barrier installed at exterior walls adjacent to showers and on exterior wall tubs shall separate them from the showers and tubs. be Insulated. Electrlcallphone box or The air baffler shall be Installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be Installed. WVAC igister boots 14VAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed In a manner that Is recommended by the manufacturer. ' Caulking or other adhesive sealants shall not be used to fill voids 4"en.gra gn.r.i0k1gir cover plates And Walla or callinon a. ur aamuun, rnepecuon or rag walls span oe in aceoroance with the provisions of ICC400. 113/201010:38 AM EnergyGouge® USA FBC ath Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the Energy Performance Index, the more efficient the home. 1, New home or, addition 1. New (From Plans) 12. Ducts, location & Insulation level a) Supply ducts R 6.0 2: Single-family or multiple -family 2. Multi -family b) Return ducts R 6.0 d) AHU location AttidAttic 3. No. of units (if multiple -family) 3. 6 4. Number of bedrooms 4. 12 5: Is this a worst case? (yesino) 5. No 6: Conditioned floor area (sq. ft.) 6. 4044 7: Windows, type and area a) U-factor.(welghted average) 7a. 0.631 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 c) Area 7c. 390.0 8; Skylights a) U-facton(weighted average) Be. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9: Floortype, insulation level: a) Slab -on -grade (R-value) 98. 0.0 b) Wood, raised (R-value) 9b. c) Concrete, raised (R-value) 9c. 10. Wall type and Insulation: A. Exterior. 1. Wood frame (Insulation R-value) 10A1. 2. Masonry (Insulation R-value) 10A2. 4.1 B. Adjacent: 1. Wood frame (Insulation R-value) 10B1. 2. Masonry (Insulation R-value) 10132. 19. Ceiling type and insulation level a) Under attic 11a. 30.0 b) Single assembly 11 b. c)Knee wallatskylightwalls 110. d) Radiant barrier installed 11d. Yes 13. Cooling system: Capacty 112.8 a) Split system SEER b) Single package SEER c) Ground/water source SEER/COP d) Room unit/PTAC EER e) Other 16.0 14. Heating system: Capacity 102.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE_ 0 Other 15. Water heating system a) Electric resistance EF 0.95 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ 0 Heat recovery unit HeatRec% g) Other 16. HVAC credits claimed (Performance Method) a) Ceiling fans Yes b) Cross ventilation No c) Whole house fan No d) Multizone cooling credit e) Multizone heating credit 0 Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) In this home before final inspection. Otherwise, a new EPL display card will be completed based on Installed codeampliant features. Builder Address of New Home: Date: I I:zq I I City/FLZip:-FT. PIERCE. FL 1/3/201910:36:45 AM EnergyGauge®USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1