FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: SEDONA DEVELOPMENT Bldg 10
Builder Name:
Street: 3142-3152 MORNING DEW LANE
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number:1807-0810
Owner.
Jurisdiction:
Design Locaflon: FL, Fort Pierce
County: St. Lucie (Florida Climate
Zone 2 )
1. New'cOnstruction or existing New (From Plans)
9. Wall Types(6420.0 sqft.)
Insulation Area
2. Single family or multiple family Multi -family
a. Concrete Block - Int Insul, Exterior
R=4.1 6420.00 ft2
3. Number of units, if multiple family g
b. N/A
R= ft2
4. Number of Bedrooms 12
c. WA
d. N/A
R= ft2
R= ft2
5. Is this a worst case? No
10. Calling Types (4046.0 sgft.)
Insulation Area
6. Condltioned floor area above grade (ft2) 4044
a. Under Attic (Vented)
b. WA
R=30.0 4046.001N
R= ft=
Conditioned floor area below grade (fo 0
c. N/A
R= ft2
7. Windows(390.0 sgft.) Description Area
113 additional duct system(s)
R ft2
6 135
a. U-Factor. Dbl, U=0.65 240.00 fN
b. Sup: Attic, Ret: Attic, AH: UNIT 1
6 135
SHGC: SHGC=0.25
c. Sup: Attic, Ret: Attic, AH: UNIT 1
(see detail
b. U-Factor. Dbl, U=0.60 150.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.25
a. Central Unit
18.8 SEER:16.00
c. U-Factor. N/A ftz
b. Central Unit
18.8 SEERA6.00
SH9C:
3 additional cooling systems
(see details)
d. U-Factor. WA ft2
13. Heating systems
kBtu/hr Efficiency
SHGC:
a. Electric Strip Heat
1T.0 COP:1.00
b. Electric Strip Heat
17.0 COP:1.00
Area Weighted Average Overhang Depth: 1.000 ft.
3 additional heating systems
(see details)
Area Weighted Average SHGC: 0.260
14. Hot water systems
S. Floor Types (4044.0 sgft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab, On -Grade Edge Insulation R=0.0 4044.00 ft2
b. Conservation features
EF: 0.950
b. WA, R= ft2
c. N/A
None
R= ft2
15. Credits
CF, Pstat
Glass/FloorArea: 0.096 Total Proposed Modified Loads: 151.79
PASS
Total Baseline Loads: 157.99
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Review of the plans and
�Q41iB Sr4?6
Code.
specifications covered by this
y p�
calculation Indicates compliance
u
with the Florida Energy Code.
f� nsr;. •• pp f aN
PREPAR D B :
DATE: •
Before construction is completed
this building will be inspected for
t
Id' " A
compliance with Section 553.908
I hereby certify that t s b g, as designed, is in compliance
Florida Statutes.
with the Florida En y C e.WMIS
OWNEW/AGENT
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as
certified factorysealed In accordance with R403.3.2.1.
Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
SCANNED
BY
St. Lucie County
He CmpY
1131201910:36 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPnRT
PROJECT
Tide: SEDONA DEVELOPMENT B
Bedrooms: 12
Address Typo:
Street Address
BuildinglType: User
Conditioned Area: 40"
Lot#
Owner Name:
Total Stories: 1
Block/Subdivision:
# of Units: 6
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
3142-3152 MORNING
Permit Office: ST. LUCIE COUNTY
Crass Ventilation: No
County:
St. Lucie
JurisdiclJon:
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family type: Muid-family
FL,
' Now/Existing: New (From Plans)
Comment
CLIMATE
. /
Design Temp
Int Design Temp Heating Design Daily Temp
V Design Location TMY Site 97.6 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH,JVIUNI 39 90
70
75 299
62
Low
BLOCKS
Number Name Area
Volume
1 Blockl 668
6880
2 Block2 667
6670
3 Blodr3 667
6670
4 Block4 1334 13340
5 Block5 688
6880
SPACES
Number Name Area
Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1 UNIT 1 688
6880 Yes 2
2
1 Yes
Yes
Yes
2 UNIT 2 667
6670 No 2
2
1 Yes
Yes
Yes
3 UNIT 667
6670 No 2
2
1 Yes
Yes
Yes
4 UNIT AND 5 1334
13340 No 2
4
1 Yes
Yes
Yes
5 UNIT 688
6880 No 2
2
1 Yes
Yes
Yes
FLOORS
# Floor Type Spars Perimeter PadmeterR-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
UNIT 1 126 ft 0
688 fN
—
1 0
0
2Slab-On-Grade Edge Insulatio
UNIT2 125 It 0
667 fl
—
0 0
1
3 Slab -On -Grade Edge Insulatio
UNIT 3 125 ft 0
667 ft'
1 0
0
4SIab-On-Grade Edge Insulatio UNIT
4 AND 5 250 ft 0
1334 11
__-
1 0
0
5Slab-On-Grade Edge Insulatio
UNIT 6 125 It 0
688 fN
1 0
0
113/201910:36 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
ROOF
/
Roof
Gable
Roof Solar
SA
Emitt
Emitt
Deck
Pitch
V
#
Type Materials Area
Area
Color Absor. Tested
Tested
Insul.
(deg)
1
Gable or shed Composition shingles 4380 ft2
842112
Ught 0.6
No
0.9
No
0
22.6
ATTIC
/
V
e
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Vented
300
4044 f12
N
N
CEILING
#
Ceiling Type Space
R Value
Ins Type
Area
Framing Frac Truss Type
_
1
Under Attic (Vented) UNIT
30
Blown
688ft2
0.11
Wood
_
2
Under Attic (Vented) UNIT 1
30
Blown
668 ft2
0.11
Wood
_
3
Under Attic (Vented) UNIT 1
30
Blown
668 ft2
0.11
Wood
_
4
Under Attic (Vented) UNIT 1
30
Blown
1334 ft2
0.11
Wood
5
Under Attic (Vented) UNIT 1
30
Blown
688 ft2
0.11
Wood
WALLS
'
Adjacent Spate
Cavity Width
Height
Sheathing Framing
Solar
Below
R-NLRI..e Ft
In Et In
Aran
R.%Lql,-e
Emotion
_ 1
N
Exterior Concrete Block - Int Insul UNIT 1
4.1 16
10
160.0 ft2
0
0
0.5
0
-2
E
Exterior Concrete Block- Int Insul UNIT 1
4.1 45
10
460.0 ft2
0
0
0.5
0
3
S
Exterior Concrete Block - Int Insul UNIT 1
4.1 16
10
160.0 ft2
0
0
0.5
0
-4
W
Exterior Concrete Block - Int Insul UNIT 1
4.1 45
10
450.0 fix
0
0
0.5
0
_ 5
N
Exterior Concrete Block - Int Insul UNIT 2
4.1 16
10
160.0 ill
0
0
0.5
0
6
E
Exterior Concrete Block - Int Insul UNIT 2
4.1 45
10
460.0 ft2
0
0
0.5
0
_7
S
Exterior ConcreteBlock- Intlnsul UNIT
4.1 16
10
160.0 ft2
0
0
0.5
0
_ 8
E
Exterior Concrete Block- Int Insul UNIT 2
4.1 45
10
450.0 ft2
0
0
0.5
0
_ 9
N
Exterior Concrete Block - Int Insul UNIT 3
4.1 16
10
160.0 ft2
0
0
0.5
0
10
E
Exterior 'Concrete Block - Int Insul UNIT 3
4.1 45
10
450.0 ft2
0
0
0.5
0
_ 11
S
Exterior Concrete Block - Int Insul UNIT 3
4.1 16
10
160.0 ft2
0
0
0.5
0
_ 12
W
Exterior Concrete Block - Int Insul UNIT 3
4.1 45
10
450.0 f12
0
0
0.5
0
_ 13
N
Exterior Concrete Block - Int InsWNIT 4 AND
4.1 32
10
320.0 ft2
0
0
0.5
0
_ 14
E
Exterior Concrete Block - Int InsWNIT 4 AND
4.1 45
10
450.0 IF
0
0
0.5
0
_ 15
S
Exterior Concrete Block - Int InsWNIT 4 AND
4A 32
10
320.0 fN
0
0
0.5
0
_16
W
Exterior Concrete Block- Int InsWNIT 4 AND
4.1 45
10
450.0 fP
0
0
0.5
0
17
N
Exterior Concrete Block - Int Insul UNIT 6
4.1 16
10
160.0 ft2
0
0.5
0
_18
' E
Exterior Concrete Block - Int Insul UNIT 6
4.1 45
10
450.0 ft2
0
0.6
0
_ 19
S
Exterior Concrete Block - Int Insul UNIT 6
4.1 16
10
160.0 fP
0
0.5
0
20
W
Exterior Concrete Block - Int Insul UNIT 6
4.1 45
10
450.0 112
0
0.5
0
113/201910:36 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
DOORS
#
Ornt Door Type
Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
_ 1
N Insulated
UNIT 1
None
.37 3
6 8
20 ft2
_ 2
N Insulated
UNIT
None
.37 3
6 8
20 ft2
3
S Insulated
UNIT 3
None
.37 3
6 8
20 ft2
_ 4
W Insulated
UNIT 4 AND
None
.37 3
6 8
20 ft2
_ 5
W Insulated
UNIT 4AND
None
.37 3
6 8
20 ft2
6
S Insulated
UNIT
None
.37 3
6 8
20 IF
WINDOWS
Orientation shown is the entered Proposed orientation.
Wall
Overhang
V .#
Omt ID Frame Panes
NFRC
U-Factor SHGC
Imp
Area Depth
Separation
Int Shade
Screening
1
N 1 Vinyl Low-E Double
Yes
0.65 0.26
N
40.0 ft2 1 ft 0 in
1 ft 41n
Drapes/blinds
None
2
S 3 Vinyl Low-E Double
Yes
0.6 0.25
N
20.0 ft2 1 ft 0 In
1 ft 4 in
Drapeslblinds
None
3
W 4 Vinyl Low-E Double
Yes
0.6 0.25
N
15.0 ft2 1 It 0 in
1 ft 4 in
Drapeslblinds
None
�4
N 5 Vinyl Low-E Double
Yes
0.65 0.25
N
40.0 f11 ft 0 in
1 It 41n
Drapes/blinds
None
z
S 7 Vinyl Low-E Double
Yes
0.6 0.25
N
20.0 112 1 ft 0 in
1 ft 4 In
Drapes/blinds
None
6
N 9 Vinyl Law-E Double
Yes
0.65 0.25
N
40.0 ft2 1 ft 0 in
1 ft 4 in
Drapeslblinds
None
_ 7
S 11 Vinyl Low-E Double
Yes
0.6 0.25
N
20.0 ft2 1 ft 0 in
1 ft 4 in
Drapes/blinds
None
8
N 13 Vinyl Low-E Double
Yes
0.65 0.26
N
80.0 ft2 1 It 0 in
1 ft 4 in
Drapes/blinds
None
.9
S 15 Vinyl Low-E Double
Yes
0.6 0.25
N
40.0 fF 1 ft 0 in
1 ft 4 in
Drapeslblinds
Nona
_ 10
N 17 Vinyl Low-E Double
Yes
0.65 0.25
N
40.0 ft2 1 ft 0 in
1 It 4 in
Drapes/blinds
None
_ 11
E 18 Vinyl Low-E Double
Yes
0.6 0.25
N
16.0 ft2 1 It 0 in
1 It 4 In
Drapeslblinds
None
_ 12
S 19 Vinyl Low-E Double
Yes
0.6 0.25
N
20.0 ft2 1 It 0 In
1 It 4 in
Drapeslblinds
None
INFILTRATION
# Scope
Method
SLA CFM 50 ELA
EgLA ACH
ACH 50
1 Wholehouse ProposedACH(50) .000445
4718 259.01
487.11 .3446
7
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip Neat/
None
COPA
17 kBtu/hr
1
sys#1
2
Electric Strip Heat/
None
COPA
17 kBtulhr
2
sys#2
3
Electric Strip HeaU
None
COP:1
17 kBtu/hr
3
sysW
5
Electric Strip HeaU
None
COPA
17 kStu/hr
5
sys#5
4 A
Electric Strip Heat/
None
COPA
17 kBtu/hr
4
sys#4
4 B
Electric Strip Heat/
None
COP:1
17 kBtulhr
4
sys#4
1/3/2019 10:36 AM EnergyGauge® USA Section R406.4.1 Compliant Software Page 4 of 6
FORM R405-2017 INPI IT RI IMMADV f%MrrVI ICT 000nOT
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity
Air Flow SHR
Block
Ducts
1
Central Unit/
None
SEER: 16 18.8 kBtulhr
564 ofm 0.8
1
sys#1
2
Central Unit/
None
SEER: 16 18.8 kBtulhr
554 cfm 0.8
2
sys#2
3
Central Unit/
None
SEER: 16 18.8 k8tulhr
S64 cfm 0.8
3
sys#3
5
Central Unit/
None
SEER: 16 18.8 kBtulhr
564 oft 0.8
6
sy8#6
4A
Central Unit/
None
SEER: IS 18.8 kBtumr
564 arm 0.8
4
sys#4
48
Central Unit/
None
SEER: 16 18.8 kBtulhr
564 dm 0.8
4
sys#4
HOT WATER SYSTEM
#
System Type
SubType
Location
EF Cap Use
SetPnt Conservation
1
Electric
None
UNIT 1
0.95 40 gal 130 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cart # Company Name
System Model # Collector Model # Area Volume
FEF
None None
IF
DUCTS
Supply --
— Return — Air CFM 25 CFM25
HVAC #
V
#
Location R-Value Area
Location
Area Leakage Type Handler
TOT OUT ON
RLF
Heat Cool
.
1
Attic
6 135 fP
Attic
35 ft' Default Leakage UNIT 1
(Default) (Default)
1 1
2
Attic
6 136 IF
Attic
35 IF Default Leakage UNIT 1
(Default) (Default)
2 2
3
Attic
6 135 f12
Attic
35 IF Default Leakage UNIT 1
(Default) (Default)
3 3
4
Attic
6 260 IF
Attic
65 fi' Default Leakage UNIT 1
(Default) (Default)
4 4
5
Attic
6 135 ft'
Attic
35 ft' Default Leakage UNIT 1
(Defauft) (Default)
5 5
TEMPERATURES
Programabl[eThermostat
[Re'nting
Cralling Fans:
,
p(1
,]Y
Jan Feb
x Mar
(
p' [
D0 [X] [X]
May [ ] Jun [ ] Jul [ ] Aug
[X] [ ]
[ ] Sep L J Oct
Nov
rD0'
Vealing
II II
Jan t I Feb
I l
X Mar
I
f 1 Jun [ ] Jul [ ] Aug
t ] Sep lxJ
f Nov
[ ]Dec
1/3/2019 10:36 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 6
FORM R405-2017
IMP"T SIIIVINIORV [:WPf 1eI ICT oGonoT
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule, ypa
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
PM
66
66
66
66
66
68
68
68
fib
88
68
68
68
68
68
68
68
68
68,
68
6s
as
66
66
Hea0ng(WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
66
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Defauit(8 Ibs/sq.ft.
0 ft'
0 ft
0.3
UNIT 1
Default(8 Ibs/sq.ft.
Oft
0
ft
0.3
UNIT 2
Default(8 Ibs/sq.ft.
0 fta
0 ft
0.3
UNIT 3
Defaalt(s Ibs/sq.ft.
0 ft'
O ft
0.3
UNIT 4 AND 5
Default 8 Iba/s .ft.
0 fta
Oft
0.3
UNIT 6
Name: Test Rater
Rating Compant: Test Rater
Date: LA-rl
I'( ffi J
1/3/201910:38 AM EnergyGeuge® USA Section R405.4.1 Compliant Software Page 6 of 6
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: SEDONA DEVELOPMENT Bldg 10 Builder Name:
Street: 31423152 MORNING DEW LANE Permit Office: ST. LUCIE COUNTY
City; State, zip: FT. PIERCE, FL, Permit Number..1807-0810
Owner. Jurisdiction:
w
X
Design Location: FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be Installed in the building envelope.
Alr-permeable insulation shall
requirements
The exterior thermal envelope contains a contnuous air barrier.
not be used as a sealing material.
Breaks or joints In the air barrier shall be sealed.
Celling(attic
The air barrier in any dropped calling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comer; and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope Insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall Include the air barrier.
Rim joists shall be insulated.
Floor;'
The air barrier shall be Installed at any exposed edge of
Floor framing cavity Insulation shall be Installed to
(Including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be In contact with the top side
floors)
of sheathing, or continuous insulation Installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth In unvented crawl spaces shall be covered with
Where provided Instead of floor insulation, Insulation
a Class I vapor retarder with overlapping Joints taped.
shall be permanently attached to the crawlspace
Shafts] penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Bars in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
Installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures Installed in the building
shall be sealed to the drywall.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt Insulation shell be cut neatly to fit around wiring
and plumbing In exterior walls, or Insulation that on
Installation readily conforms to available space shall
Showeiltub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be Insulated.
Electrlca"'one box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be Installed.
HVAb lregister boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed In a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
„ uoyewm i e, wa wauv anaii ue in 9CAOreanw wan me provisions or rlA3-4uu.
1/3/2019 10:36 AM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: SEDONA DEVELOPMENT Bldg 10 Builder Name:
Street: 3142-3152 MORNING DEW LANE Permit Office: ST. LUCIE COUNTY
City; State, Zip: FT. PIERCE, FL, Permit Number..1807-0810
Cyr
Owner. Jurisdiction:
m
Desjgn Location: FL, Fort Pierce
X
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shell be installed in the building envelope.
Air -permeable Insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks arjoints in the air barrier shall be sealed.
Cetling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation In any dropped ceiling/aoffit
the insulation and any gaps in the air barrier shall be sealed.
shell be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per Inch minimum.
Exterior thermal envelope Insulation for framed
walls shall be Installed In substantial contact and
continuous alignment with the air baffler.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim Joists shall include the air barrier.
Rim joists shall be Insulated.
Floors
The air barrier shall be Installed at any exposed edge of
Floor framing cavity Insulation shall be Installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloar docking, or floor framing cavity Insulation
and cantilevered
shall be permitted to be In contact with the top side
floors)
of sheathing, or continuous insulation Installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided Instead of floor Insulation, Insulation
a Class I vapor retarder with overlapping Joints taped.
shall be permanently attached to the crewlspace
Shafts; penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall he sealed.
'
Batts In narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
Installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
is.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed In the building
•
shall be sealed to the drywall.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt Insulation shall be cut heady to fit around wiring
and plumbing In exterior walls, or insulation that on
Installation readily conforms to available space shall
extend behind piping and wiring,
Exterior walls adjacent to showers and tubs shall
ShoweOub
The air barrier installed at exterior walls adjacent to showers and
on exterior wall
tubs shall separate them from the showers and tubs.
be Insulated.
Electrlcallphone box or
The air baffler shall be Installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be Installed.
WVAC igister boots
14VAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed In a manner that Is recommended by the manufacturer.
'
Caulking or other adhesive sealants shall not be used to fill voids
4"en.gra gn.r.i0k1gir cover plates And Walla or callinon
a. ur aamuun, rnepecuon or rag walls span oe in aceoroance with the provisions of ICC400.
113/201010:38 AM EnergyGouge® USA FBC ath Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 96
The lower the Energy Performance Index, the more efficient the home.
1, New home or, addition 1. New (From Plans) 12. Ducts, location & Insulation level
a) Supply ducts R 6.0
2: Single-family or multiple -family 2. Multi -family b) Return ducts R 6.0
d) AHU location AttidAttic
3. No. of units (if multiple -family) 3. 6
4. Number of bedrooms 4. 12
5: Is this a worst case? (yesino) 5. No
6: Conditioned floor area (sq. ft.) 6. 4044
7: Windows, type and area
a) U-factor.(welghted average) 7a. 0.631
b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250
c) Area 7c. 390.0
8; Skylights
a) U-facton(weighted average) Be. NA
b) Solar Heat Gain Coefficient (SHGC) 8b. NA
9: Floortype, insulation level:
a) Slab -on -grade (R-value)
98. 0.0
b) Wood, raised (R-value)
9b.
c) Concrete, raised (R-value)
9c.
10. Wall type and Insulation:
A. Exterior.
1. Wood frame (Insulation R-value)
10A1.
2. Masonry (Insulation R-value)
10A2. 4.1
B. Adjacent:
1. Wood frame (Insulation R-value)
10B1.
2. Masonry (Insulation R-value)
10132.
19. Ceiling type and insulation level
a) Under attic
11a. 30.0
b) Single assembly
11 b.
c)Knee wallatskylightwalls
110.
d) Radiant barrier installed
11d. Yes
13. Cooling system:
Capacty 112.8
a) Split system
SEER
b) Single package
SEER
c) Ground/water source SEER/COP
d) Room unit/PTAC
EER
e) Other
16.0
14. Heating system: Capacity 102.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
c) Electric resistance COP 1.0
d) Gas furnace, natural gas AFUE
e) Gas furnace, LPG AFUE_
0 Other
15. Water heating system
a) Electric resistance EF 0.95
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF_
0 Heat recovery unit HeatRec%
g) Other
16. HVAC credits claimed (Performance Method)
a) Ceiling fans Yes
b) Cross ventilation No
c) Whole house fan No
d) Multizone cooling credit
e) Multizone heating credit
0 Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) In this home before final inspection. Otherwise, a new EPL
display card will be completed based on Installed codeampliant features.
Builder
Address of New Home:
Date: I I:zq I I
City/FLZip:-FT. PIERCE. FL
1/3/201910:36:45 AM EnergyGauge®USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1