Loading...
HomeMy WebLinkAboutREVIEW COMMENTSPlanning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(7721462-2172 Fax:(772)462-6443 PROPERTY INFORMATION Address: 4500 W Midway Road - Bid 8 City I State I Zip: Fort Pierce. FI 34981 Parcel #: 3406-501-0014-500/9 Zoning: I APPLICATION INFORMATION Permit Number: 1812-0362 PermItType: BUILDING COMMERCIAL Contractor Name: Michael E Jacquin Business Name: Paul Jacquin & Sons Inc Business Addr: P 0 Box 4343 City I State / Zip: Ft Pierce, FI 34948 REVIEW COMMENTS d Owner(s): New Horizons Of The Treasure Coast Jurisdiction: SAINT LUCIE COUNTY Lot#: 9 Block: Stories: Automatic Sprinkler System? No SCANNSID Fax Number: 772-466-2806 S Y St. LLIC. re cOunty Email: Mchael.Jacquin@Pjs].Com RevlewTvPe Status Reviewed By Data Started Date Completed Date Released DOCUMENTS MISSING PENDING Lashahna Ingram 1 RECEIVED 12/1a12018 Comment: NEEDS ELECTRICAL SUB 1211MO18 Comment NEEDS PLUMBING SUB JAN 2 4 2019 1211812018 Comment: NEEDS MECHIHVAC SUB ST. Lude count, 1211812018 Comment: NEEDS ROOFING SUB 11412019 ------ KqKLEAsr: PROVIDE AN FRONT COUNTER REVIEW COMPLETE Lashahnaingrarn 1211812018 12M812018 1211812018 Comment: PLANS EXAMINER ELECTRIC PENDING Walter Pride Comment: PLANS EXAMINER MECHANICAL COMPLETE Carl Peterson 111412019 1114/2019 111412019 Comment: PLANS EXAMINER PLUMBING COMPLETE Andy Wentz 111112019 111112019 1111/2019 Comment: PLANS EXAMINER REVIEW INCOMPLETE JpI, Inc 11912019 Comment: 1) PLEASE PROVIDE FLAME SPREAD INDEX AND SMOKE -DEVELOPED INDEX REQUIREMENTS FOR 119/2019 INSULATION. (720.1) Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(7721462-2172 Fox:(772)462-6443 REVIEW COMMENTS Comment: 2) CORRIDORS SHALL BE FIRE -RESISTANCE RATED IN ACCORDANCE WITH [ABLE11IZU.I. 11-ItUUKKIIJUK 1/912019 WALLS REQUIRED TO BE FIRE -RESISTANCE RATED SHALL COMPLY WITH SECTION 708 FOR FIRE PARTITIONS. (1020.1) Comment: 3)THE EXIT ACCESS SHALL BE ARRANGED SUCH THAT THERE ARE NO DEAD ENDS IN CORRIDORS MORE 1/9/2019 THAN 20 FEET IN LENGTH. (1020.4) Comment 4) PLEASE INCLUDE IN THE PRODUCT REVIEW AFFIDAVIT- LAP SIDING, ROOF COVERING. INCLUDE 11912019 ATTACHMENT METHOD OF SIDING TO MASONRYWALL. ([Al 107.2.1) 119/2019 Comment: 5) PROVIDE SPECIFICATIONS FOR SITE PREPARATION AND FILL FOR FOUNDATION PER (1803.5.8) 1/912019 Comment: 6) PROVIDE SPECIFICATIONS FOR THE CONCRE�E & REINFORCING PER 1901.5) 11912019 Comment: 7) CONTROL AND CONTRACTION JOINTS SHALL BE DESIGNED BYAN ARCHITECT OR ENGINEER. (1907.2) 1/1012019 Comment: 8) PLEASE PROVIDE SOFFIT DETAIL FOR FRAMED PORCHES. (1609.1) 1/1012019 Comment: 9) PLEASE PROVIDE FLASHING DETAILS FOR ROOF TO WALL CONNECTIONS. GAI 107.2.4) Comment 10) PLEASE PROVIDE WINDOW, SWING DOOR AND OVERHEAD DOOR ATTACHMENT TO METAL BUILDING. 1/1012019 ([A] 107.2.1) 1/1012019 Comment: 11) PLEASE PROVIDE DETAILS FOR THE FOR THE ADA PARKING SPACE AND SIGN. (502.1) ZONING REVIEW INCOMPLETE Lydia Galbraith 11312019 1/4r2019 Comment: IS DEMOLITION PERMIT # 1812-0363 FOR THE EXISTING 3,395 SF PRE-FAB BUILDING AT LOCATION OF THE PROPOSED BUILDING? A SEPARATE DEMO PERMIT FOR BUILDING D IS REQUIRED AS WELL 114/2019 Comment: PLEASE PROVIDE THE COST OF CONSTRUCTION. comment: ILLEASE�PR(SiEFE�A -,'Ektl�A-�8ET..-Cr,.8VIL-DRAWINr '6)®R'�ERNGdi-tiE'E--R"I-N'Gt�i� ENAOR 1/412019 _;,,s F, NSTRUCD �0111A IW*E Comment:4.",�FLEASE,P,,j,OV1DE S-SIGNED j_,D SEALED BOUNDARY SURVEYS INDICTING THE ELEVATION OF CENTER 'ISHED FLOOR ELEVATION IS 18- ABOVE CROWN OF ADJACENT ROAD. SITE ou� 114t2019 -A( 0 ,M .1 , btURVEYIN SITE PLAN FILE ARE MISSING THIS INFORMATION. 1/4120ig Comment: PLEASE BE AWARE THAT ABOVE COMMENTS ONLY REFLECTS THE ZONING REVIEW. THE PLANS EXAMINER MIGHT HAVE ADDITIONAL COMMENTS. 1/812019 Comment: STORM WATER PERMIT OR UPDATE OF STORM WATER PERMIT IS REQUIRED. PLEASE CONTACT BABY THOTTAKARA AT 772-462-2097 TO SUBMIT APPLICATION AND TO ANSWER QUESTIONS.