HomeMy WebLinkAboutREVIEW COMMENTSPlanning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982
Phone:(7721462-2172 Fax:(772)462-6443
PROPERTY INFORMATION
Address:
4500 W Midway Road - Bid 8
City I State I Zip:
Fort Pierce. FI 34981
Parcel #:
3406-501-0014-500/9
Zoning:
I
APPLICATION INFORMATION
Permit Number:
1812-0362
PermItType:
BUILDING COMMERCIAL
Contractor Name:
Michael E Jacquin
Business Name:
Paul Jacquin & Sons Inc
Business Addr:
P 0 Box 4343
City I State / Zip:
Ft Pierce, FI 34948
REVIEW COMMENTS
d
Owner(s):
New Horizons Of The Treasure Coast
Jurisdiction: SAINT LUCIE COUNTY
Lot#: 9 Block:
Stories: Automatic Sprinkler System? No
SCANNSID Fax Number: 772-466-2806
S Y
St. LLIC.
re cOunty Email: Mchael.Jacquin@Pjs].Com
RevlewTvPe
Status Reviewed By
Data Started Date Completed Date Released
DOCUMENTS MISSING
PENDING Lashahna Ingram
1
RECEIVED
12/1a12018 Comment:
NEEDS ELECTRICAL SUB
1211MO18 Comment
NEEDS PLUMBING SUB
JAN 2 4 2019
1211812018 Comment:
NEEDS MECHIHVAC SUB
ST. Lude count,
1211812018 Comment:
NEEDS ROOFING SUB
11412019 ------ KqKLEAsr: PROVIDE AN
FRONT COUNTER REVIEW
COMPLETE Lashahnaingrarn
1211812018 12M812018 1211812018
Comment:
PLANS EXAMINER ELECTRIC
PENDING Walter Pride
Comment:
PLANS EXAMINER MECHANICAL
COMPLETE Carl Peterson
111412019 1114/2019 111412019
Comment:
PLANS EXAMINER PLUMBING
COMPLETE Andy Wentz
111112019 111112019 1111/2019
Comment:
PLANS EXAMINER REVIEW
INCOMPLETE JpI, Inc
11912019
Comment:
1) PLEASE PROVIDE FLAME SPREAD INDEX AND SMOKE -DEVELOPED INDEX REQUIREMENTS FOR
119/2019
INSULATION. (720.1)
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982
Phone:(7721462-2172 Fox:(772)462-6443
REVIEW COMMENTS
Comment:
2) CORRIDORS SHALL BE FIRE -RESISTANCE RATED IN ACCORDANCE WITH [ABLE11IZU.I. 11-ItUUKKIIJUK
1/912019
WALLS REQUIRED TO BE FIRE -RESISTANCE RATED SHALL COMPLY WITH SECTION 708 FOR FIRE
PARTITIONS. (1020.1)
Comment:
3)THE EXIT ACCESS SHALL BE ARRANGED SUCH THAT THERE ARE NO DEAD ENDS IN CORRIDORS MORE
1/9/2019
THAN 20 FEET IN LENGTH. (1020.4)
Comment
4) PLEASE INCLUDE IN THE PRODUCT REVIEW AFFIDAVIT- LAP SIDING, ROOF COVERING. INCLUDE
11912019
ATTACHMENT METHOD OF SIDING TO MASONRYWALL. ([Al 107.2.1)
119/2019 Comment:
5) PROVIDE SPECIFICATIONS FOR SITE PREPARATION AND FILL FOR FOUNDATION PER (1803.5.8)
1/912019 Comment:
6) PROVIDE SPECIFICATIONS FOR THE CONCRE�E & REINFORCING PER 1901.5)
11912019 Comment:
7) CONTROL AND CONTRACTION JOINTS SHALL BE DESIGNED BYAN ARCHITECT OR ENGINEER. (1907.2)
1/1012019 Comment:
8) PLEASE PROVIDE SOFFIT DETAIL FOR FRAMED PORCHES. (1609.1)
1/1012019 Comment:
9) PLEASE PROVIDE FLASHING DETAILS FOR ROOF TO WALL CONNECTIONS. GAI 107.2.4)
Comment
10) PLEASE PROVIDE WINDOW, SWING DOOR AND OVERHEAD DOOR ATTACHMENT TO METAL BUILDING.
1/1012019
([A] 107.2.1)
1/1012019 Comment:
11) PLEASE PROVIDE DETAILS FOR THE FOR THE ADA PARKING SPACE AND SIGN. (502.1)
ZONING REVIEW INCOMPLETE Lydia Galbraith 11312019
1/4r2019 Comment: IS DEMOLITION PERMIT # 1812-0363 FOR THE EXISTING 3,395 SF PRE-FAB BUILDING AT LOCATION OF THE
PROPOSED BUILDING? A SEPARATE DEMO PERMIT FOR BUILDING D IS REQUIRED AS WELL
114/2019 Comment: PLEASE PROVIDE THE COST OF CONSTRUCTION.
comment: ILLEASE�PR(SiEFE�A -,'Ektl�A-�8ET..-Cr,.8VIL-DRAWINr '6)®R'�ERNGdi-tiE'E--R"I-N'Gt�i� ENAOR
1/412019 _;,,s F,
NSTRUCD
�0111A IW*E
Comment:4.",�FLEASE,P,,j,OV1DE S-SIGNED j_,D SEALED BOUNDARY SURVEYS INDICTING THE ELEVATION OF CENTER
'ISHED FLOOR ELEVATION IS 18- ABOVE CROWN OF ADJACENT ROAD. SITE
ou� 114t2019 -A( 0 ,M .1
, btURVEYIN SITE PLAN FILE ARE MISSING THIS INFORMATION.
1/4120ig Comment: PLEASE BE AWARE THAT ABOVE COMMENTS ONLY REFLECTS THE ZONING REVIEW. THE PLANS
EXAMINER MIGHT HAVE ADDITIONAL COMMENTS.
1/812019 Comment: STORM WATER PERMIT OR UPDATE OF STORM WATER PERMIT IS REQUIRED. PLEASE CONTACT BABY
THOTTAKARA AT 772-462-2097 TO SUBMIT APPLICATION AND TO ANSWER QUESTIONS.